Normalized to: Quan, Y.
[1]
oai:arXiv.org:1712.01932 [pdf] - 1799803
Backgrounds and pulse shape discrimination in the ArDM liquid argon TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
Di Luise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Nguyen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2017-12-02
The ArDM experiment completed a single-phase commissioning run in 2015 with
an active liquid argon target of nearly one tonne in mass. The analysis of the
data and comparison to simulations allowed for a test of the crucial detector
properties and confirmed the low background performance of the setup. The
statistical rejection power for electron recoil events using the pulse shape
discrimination method was estimated using data from a Cf-252 neutron
calibration source. Electron and nuclear recoil band profiles were found to be
well described by Gaussian distributions. Employing such a model we derive
values for the electron recoil statistical rejection power of more than 10$^8$
in the tonne-scale liquid argon target for events with more than 50 detected
photons at a 50% acceptance for nuclear recoils. The Rn-222 emanation rate of
the ArDM cryostat at room temperature was found to be 65.6$\pm$0.4 $\mu$Hz/l,
and the Ar-39 specific activity from the employed atmospheric argon to be
0.95$\pm$0.05 Bq/kg. The cosmic muon flux at the Canfranc underground site was
determined to be between 2 and 3.5$\times 10^{-3}m^{2}s^{-1}$ . These results
pave the way for the next physics run of ArDM in the double-phase operational
mode.
[2]
oai:arXiv.org:1612.06375 [pdf] - 1551971
The ArDM Liquid Argon Time Projection Chamber at the Canfranc
Underground Laboratory: a ton-scale detector for Dark Matter Searches
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-12-19
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time
projection chamber (TPC) sensitive to nuclear recoils resulting from scattering
of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets.
With an active target of 850 kg, ArDM represents an important milestone in the
quest for Dark Matter with LAr. We present the experimental apparatus currently
installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain.
We show first data recorded during a single-phase commissioning run in 2015
(ArDM Run I), which overall confirm the good and stable performance of the
ton-scale LAr detector.
[3]
oai:arXiv.org:1611.02481 [pdf] - 1510448
Measurement of the attenuation length of argon scintillation light in
the ArDM LAr TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-11-08
We report on a measurement of the attenuation length for the scintillation
light in the tonne size liquid argon target of the ArDM dark matter experiment.
The data was recorded in the first underground operation of the experiment in
single-phase operational mode. The results were achieved by comparing the light
yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a
model of full light ray tracing. A relatively low value close to 0.5 m was
found for the attenuation length of the liquid argon bulk to its own
scintillation light. We interpret this result as a presence of optically active
impurities in the liquid argon which are not filtered by the installed
purification systems. We also present analyses of the argon gas employed for
the filling and discuss cross sections in the vacuum ultraviolet of various
molecules in respect to purity requirements in the context of large liquid
argon installations.