sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Pyle, M.

Normalized to: Pyle, M.

36 article(s) in total. 626 co-authors, from 1 to 30 common article(s). Median position in authors list is 60,5.

[1]  oai:arXiv.org:2005.14067  [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration; Amaral, D. W.; Aralis, T.; Aramaki, T.; Arnquist, I. J.; Azadbakht, E.; Banik, S.; Barker, D.; Bathurst, C.; Bauer, D. A.; Bezerra, L. V. S.; Bhattacharyya, R.; Binder, T.; Bowles, M. A.; Brink, P. L.; Bunker, R.; Cabrera, B.; Calkins, R.; Cameron, R. A.; Cartaro, C.; Cerdeño, D. G.; Chang, Y. -Y.; Chen, R.; Chott, N.; Cooley, J.; Coombes, H.; Corbett, J.; Cushman, P.; De Brienne, F.; di Vacri, M. L.; Diamond, M. D.; Fascione, E.; Figueroa-Feliciano, E.; Fink, C. W.; Fouts, K.; Fritts, M.; Gerbier, G.; Germond, R.; Ghaith, M.; Golwala, S. R.; Harris, H. R.; Herbert, N.; Hines, B. A.; Hollister, M. I.; Hong, Z.; Hoppe, E. W.; Hsu, L.; Huber, M. E.; Iyer, V.; Jardin, D.; Jastram, A.; Kelsey, M. H.; Kubik, A.; Kurinsky, N. A.; Lawrence, R. E.; Li, A.; Loer, B.; Asamar, E. Lopez; Lukens, P.; MacDonell, D.; MacFarlane, D. B.; Mahapatra, R.; Mandic, V.; Mast, N.; Mayer, A. J.; Michaud, É. M.; Michielin, E.; Mirabolfathi, N.; Mohanty, B.; Mendoza, J. D. Morales; Nagorny, S.; Nelson, J.; Neog, H.; Novati, V.; Orrell, J. L.; Oser, S. M.; Page, W. A.; Pakarha, P.; Partridge, R.; Podviianiuk, R.; Ponce, F.; Poudel, S.; Pyle, M.; Rau, W.; Reid, E.; Ren, R.; Reynolds, T.; Roberts, A.; Robinson, A. E.; Rogers, H. E.; Saab, T.; Sadoulet, B.; Sander, J.; Sattari, A.; Schnee, R. W.; Scorza, S.; Serfass, B.; Sincavage, D. J.; Stanford, C.; Stein, M.; Street, J.; Toback, D.; Underwood, R.; Verma, S.; Villano, A. N.; von Krosigk, B.; Watkins, S. L.; Wills, L.; Wilson, J. S.; Wilson, M. J.; Winchell, J.; Wright, D. H.; Yellin, S.; Young, B. A.; Yu, T. C.; Zhang, E.; Zhang, H. G.; Zhao, X.; Zheng, L.
Comments: 5 pages + title and references, 3 figures and 1 table
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]  oai:arXiv.org:1806.07043  [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Comments: 14 pages, 10 figures, 5 tables. v5 contains the extended data release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]  oai:arXiv.org:1804.10697  [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Comments: 6 pages + title and references, 6 figures, includes erratum submitted to PRL and data release
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
[4]  oai:arXiv.org:1808.09098  [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Comments:
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
[5]  oai:arXiv.org:1805.09942  [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Agnese, Robert; Aralis, Taylor; Aramaki, Tsuguo; Arnquist, Isaac; Azadbakht, Elham; Baker, William; Banik, Samir; Barker, D'Ann; Bauer, Dan; Binder, Thomas; Bowles, Michael; Brink, Paul; Bunker, Ray; Cabrera, Blas; Calkins, Robert; Cartaro, Concetta; Cerdeno, David; Chang, Yen-Yung; Cooley, Jodi; Cornell, Brett; Cushman, Priscilla; Di Stefano, Philippe; Doughty, Todd; Fascione, Eleanor; Figueroa, Tali; Fink, Caleb; Fritts, Matt; Gerbier, Gilles; Germond, Richard; Ghaith, Muad; Golwala, Sunil; Harris, Rusty; Hong, Ziqing; Hoppe, Eric; Hsu, Lauren; Huber, Martin; Iyer, Vijay; Jardin, Dan; Jena, Chitrasen; Kelsey, Michael; Kennedy, Allison; Kubik, Andrew; Kurinsky, Noah; Lawrence, Richard; Loer, Ben; Lopez-Asamar, Elias; Lukens, Pat; MacDonell, Danika; Mahapatra, Rupak; Mandic, Vuk; Mast, Nicholas; Miller, Eric; Mirabolfathi, Nader; Mohanty, Bedangadas; Morales, Jorge; Nelson, Jack; Orrell, John; Oser, Scott; Page, William; Partridge, Richard; Pepin, Mark; Ponce, Francisco; Poudel, Sudip; Pyle, Matt; Qiu, Hang; Rau, Wolfgang; Reisetter, Angela; Ren, Tom; Reynolds, Tyler; Roberts, Amy; Robinson, Alan; Rogers, Hannah; Saab, Tarek; Sadoulet, Bernard; Sander, Joel; Scarff, Andrew; Schnee, Richard; Scorza, Silvia; Senapati, Kartik; Serfass, Bruno; Speller, Danielle; Stein, Matthew; Street, Joseph; Tanaka, Hirohisa; Toback, David; Underwood, Ryan; Villano, Anthony; von Krosigk, Belina; Watkins, Samuel; Wilson, Jon; Wilson, Matthew; Winchell, Joshua; Wright, Dennis; Yellin, Steve; Young, Betty; Zhang, Xiaohe; Zhao, Xuji
Comments: 4 Figures, Two data files, One data release description file
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
[6]  oai:arXiv.org:1712.06598  [pdf] - 1777361
Detection of Light Dark Matter With Optical Phonons in Polar Materials
Comments: 5 pages, 4 figures. Matches journal version
Submitted: 2017-12-18, last modified: 2018-10-31
We show that polar materials are excellent targets for direct detection of sub-GeV dark matter due to the presence of gapped optical phonons as well as acoustic phonons with high sound speed. We take the example of Gallium Arsenide (GaAs), which has the properties needed for experimental realization, and where many results can be estimated analytically. We find GaAs has excellent reach to dark photon absorption, can completely cover the freeze-in benchmark for scattering via an ultralight dark photon, and is competitive with other proposals to detect sub-MeV dark matter scattering off nuclei.
[7]  oai:arXiv.org:1803.02903  [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Comments: 22 pages, 17 figures, 1 table, 1 appendix
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
[8]  oai:arXiv.org:1707.01632  [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
Comments: 30 Pages, 33 Figures v3 to match published version in PRD. v2 contains public release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
[9]  oai:arXiv.org:1707.04591  [pdf] - 1585955
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Battaglieri, Marco; Belloni, Alberto; Chou, Aaron; Cushman, Priscilla; Echenard, Bertrand; Essig, Rouven; Estrada, Juan; Feng, Jonathan L.; Flaugher, Brenna; Fox, Patrick J.; Graham, Peter; Hall, Carter; Harnik, Roni; Hewett, JoAnne; Incandela, Joseph; Izaguirre, Eder; McKinsey, Daniel; Pyle, Matthew; Roe, Natalie; Rybka, Gray; Sikivie, Pierre; Tait, Tim M. P.; Toro, Natalia; Van De Water, Richard; Weiner, Neal; Zurek, Kathryn; Adelberger, Eric; Afanasev, Andrei; Alexander, Derbin; Alexander, James; Antochi, Vasile Cristian; Asner, David Mark; Baer, Howard; Banerjee, Dipanwita; Baracchini, Elisabetta; Barbeau, Phillip; Barrow, Joshua; Bastidon, Noemie; Battat, James; Benson, Stephen; Berlin, Asher; Bird, Mark; Blinov, Nikita; Boddy, Kimberly K.; Bondi, Mariangela; Bonivento, Walter M.; Boulay, Mark; Boyce, James; Brodeur, Maxime; Broussard, Leah; Budnik, Ranny; Bunting, Philip; Caffee, Marc; Caiazza, Sabato Stefano; Campbell, Sheldon; Cao, Tongtong; Carosi, Gianpaolo; Carpinelli, Massimo; Cavoto, Gianluca; Celentano, Andrea; Chang, Jae Hyeok; Chattopadhyay, Swapan; Chavarria, Alvaro; Chen, Chien-Yi; Clark, Kenneth; Clarke, John; Colegrove, Owen; Coleman, Jonathon; Cooke, David; Cooper, Robert; Crisler, Michael; Crivelli, Paolo; D'Eramo, Francesco; D'Urso, Domenico; Dahl, Eric; Dawson, William; De Napoli, Marzio; De Vita, Raffaella; DeNiverville, Patrick; Derenzo, Stephen; Di Crescenzo, Antonia; Di Marco, Emanuele; Dienes, Keith R.; Diwan, Milind; Dongwi, Dongwi Handiipondola; Drlica-Wagner, Alex; Ellis, Sebastian; Ezeribe, Anthony Chigbo; Farrar, Glennys; Ferrer, Francesc; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fiorillo, Giuliana; Fornal, Bartosz; Freyberger, Arne; Frugiuele, Claudia; Galbiati, Cristian; Galon, Iftah; Gardner, Susan; Geraci, Andrew; Gerbier, Gilles; Graham, Mathew; Gschwendtner, Edda; Hearty, Christopher; Heise, Jaret; Henning, Reyco; Hill, Richard J.; Hitlin, David; Hochberg, Yonit; Hogan, Jason; Holtrop, Maurik; Hong, Ziqing; Hossbach, Todd; Humensky, T. B.; Ilten, Philip; Irwin, Kent; Jaros, John; Johnson, Robert; Jones, Matthew; Kahn, Yonatan; Kalantarians, Narbe; Kaplinghat, Manoj; Khatiwada, Rakshya; Knapen, Simon; Kohl, Michael; Kouvaris, Chris; Kozaczuk, Jonathan; Krnjaic, Gordan; Kubarovsky, Valery; Kuflik, Eric; Kusenko, Alexander; Lang, Rafael; Leach, Kyle; Lin, Tongyan; Lisanti, Mariangela; Liu, Jing; Liu, Kun; Liu, Ming; Loomba, Dinesh; Lykken, Joseph; Mack, Katherine; Mans, Jeremiah; Maris, Humphrey; Markiewicz, Thomas; Marsicano, Luca; Martoff, C. J.; Mazzitelli, Giovanni; McCabe, Christopher; McDermott, Samuel D.; McDonald, Art; McKinnon, Bryan; Mei, Dongming; Melia, Tom; Miller, Gerald A.; Miuchi, Kentaro; Nazeer, Sahara Mohammed Prem; Moreno, Omar; Morozov, Vasiliy; Mouton, Frederic; Mueller, Holger; Murphy, Alexander; Neilson, Russell; Nelson, Tim; Neu, Christopher; Nosochkov, Yuri; O'Hare, Ciaran; Oblath, Noah; Orrell, John; Ouellet, Jonathan; Pastore, Saori; Paul, Sebouh; Perelstein, Maxim; Peter, Annika; Phan, Nguyen; Phinney, Nan; Pivovaroff, Michael; Pocar, Andrea; Pospelov, Maxim; Pradler, Josef; Privitera, Paolo; Profumo, Stefano; Raggi, Mauro; Rajendran, Surjeet; Randazzo, Nunzio; Raubenheimer, Tor; Regenfus, Christian; Renshaw, Andrew; Ritz, Adam; Rizzo, Thomas; Rosenberg, Leslie; Rubbia, Andre; Rybolt, Ben; Saab, Tarek; Safdi, Benjamin R.; Santopinto, Elena; Scarff, Andrew; Schneider, Michael; Schuster, Philip; Seidel, George; Sekiya, Hiroyuki; Seong, Ilsoo; Simi, Gabriele; Sipala, Valeria; Slatyer, Tracy; Slone, Oren; Smith, Peter F; Smolinsky, Jordan; Snowden-Ifft, Daniel; Solt, Matthew; Sonnenschein, Andrew; Sorensen, Peter; Spooner, Neil; Srivastava, Brijesh; Stancu, Ion; Strigari, Louis; Strube, Jan; Sushkov, Alexander O.; Szydagis, Matthew; Tanedo, Philip; Tanner, David; Tayloe, Rex; Terrano, William; Thaler, Jesse; Thomas, Brooks; Thorpe, Brianna; Thorpe, Thomas; Tiffenberg, Javier; Tran, Nhan; Trovato, Marco; Tully, Christopher; Tyson, Tony; Vachaspati, Tanmay; Vahsen, Sven; van Bibber, Karl; Vandenbroucke, Justin; Villano, Anthony; Volansky, Tomer; Wang, Guojian; Ward, Thomas; Wester, William; Whitbeck, Andrew; Williams, David A.; Wing, Matthew; Winslow, Lindley; Wojtsekhowski, Bogdan; Yu, Hai-Bo; Yu, Shin-Shan; Yu, Tien-Tien; Zhang, Xilin; Zhao, Yue; Zhong, Yi-Ming
Comments: 102 pages + references
Submitted: 2017-07-14
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
[10]  oai:arXiv.org:1611.04083  [pdf] - 1513810
SuperCDMS SNOLAB Low-Mass Detectors: Ultra-Sensitive Phonon Calorimeters for a Sub-GeV Dark Matter Search
Comments: 4 Pages, 3 figures, proceedings of the 38th International Conference on High Energy Physics (ICHEP), Chicago, IL, USA
Submitted: 2016-11-12
We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering events in high-purity Ge and Si crystals. In this paper we discuss some of the studies and technological improvements which have allowed us to design such a sensitive detector, including advances in phonon sensor design and detector simulation. With this design we expect to achieve better than 10 eV (5 eV) phonon energy resolution in our Ge (Si) detectors, and recoil energy resolution below 1eV by exploiting Luke-Neganov phonon generation of charges accelerated in high fields.
[11]  oai:arXiv.org:1610.00006  [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Comments: SuperCDMS SNOLAB Projected sensitivity reach
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
[12]  oai:arXiv.org:1608.08632  [pdf] - 1472452
Dark Sectors 2016 Workshop: Community Report
Alexander, Jim; Battaglieri, Marco; Echenard, Bertrand; Essig, Rouven; Graham, Matthew; Izaguirre, Eder; Jaros, John; Krnjaic, Gordan; Mardon, Jeremy; Morrissey, David; Nelson, Tim; Perelstein, Maxim; Pyle, Matt; Ritz, Adam; Schuster, Philip; Shuve, Brian; Toro, Natalia; Van De Water, Richard G; Akerib, Daniel; An, Haipeng; Aniol, Konrad; Arnquist, Isaac J.; Asner, David M.; Back, Henning O.; Baker, Keith; Baltzell, Nathan; Banerjee, Dipanwita; Batell, Brian; Bauer, Daniel; Beacham, James; Benesch, Jay; Bjorken, James; Blinov, Nikita; Boehm, Celine; Bondí, Mariangela; Bonivento, Walter; Bossi, Fabio; Brodsky, Stanley J.; Budnik, Ran; Bueltmann, Stephen; Bukhari, Masroor H.; Bunker, Raymond; Carpinelli, Massimo; Cartaro, Concetta; Cassel, David; Cavoto, Gianluca; Celentano, Andrea; Chaterjee, Animesh; Chaudhuri, Saptarshi; Chiodini, Gabriele; Cho, Hsiao-Mei Sherry; Church, Eric D.; Cooke, D. A.; Cooley, Jodi; Cooper, Robert; Corliss, Ross; Crivelli, Paolo; Curciarello, Francesca; D'Angelo, Annalisa; Davoudiasl, Hooman; De Napoli, Marzio; De Vita, Raffaella; Denig, Achim; deNiverville, Patrick; Deshpande, Abhay; Dharmapalan, Ranjan; Dobrescu, Bogdan; Donskov, Sergey; Dupre, Raphael; Estrada, Juan; Fegan, Stuart; Ferber, Torben; Field, Clive; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fornal, Bartosz; Freyberger, Arne; Friedland, Alexander; Galon, Iftach; Gardner, Susan; Girod, Francois-Xavier; Gninenko, Sergei; Golutvin, Andrey; Gori, Stefania; Grab, Christoph; Graziani, Enrico; Griffioen, Keith; Haas, Andrew; Harigaya, Keisuke; Hearty, Christopher; Hertel, Scott; Hewett, JoAnne; Hime, Andrew; Hitlin, David; Hochberg, Yonit; Holt, Roy J.; Holtrop, Maurik; Hoppe, Eric W.; Hossbach, Todd W.; Hsu, Lauren; Ilten, Phil; Incandela, Joe; Inguglia, Gianluca; Irwin, Kent; Jaegle, Igal; Johnson, Robert P.; Kahn, Yonatan; Kalicy, Grzegorz; Kang, Zhong-Bo; Khachatryan, Vardan; Kozhuharov, Venelin; Krasnikov, N. V.; Kubarovsky, Valery; Kuflik, Eric; Kurinsky, Noah; Laha, Ranjan; Lanfranchi, Gaia; Li, Dale; Lin, Tongyan; Lisanti, Mariangela; Liu, Kun; Liu, Ming; Loer, Ben; Loomba, Dinesh; Lyubovitskij, Valery E.; Manalaysay, Aaron; Mandaglio, Giuseppe; Mans, Jeremiah; Marciano, W. J.; Markiewicz, Thomas; Marsicano, Luca; Maruyama, Takashi; Matveev, Victor A.; McKeen, David; McKinnon, Bryan; McKinsey, Dan; Merkel, Harald; Mock, Jeremy; Monzani, Maria Elena; Moreno, Omar; Nantais, Corina; Paul, Sebouh; Peskin, Michael; Poliakov, Vladimir; Polosa, Antonio D; Pospelov, Maxim; Rachek, Igor; Radics, Balint; Raggi, Mauro; Randazzo, Nunzio; Ratcliff, Blair; Rizzo, Alessandro; Rizzo, Thomas; Robinson, Alan; Rubbia, Andre; Rubin, David; Rueter, Dylan; Saab, Tarek; Santopinto, Elena; Schnee, Richard; Shelton, Jessie; Simi, Gabriele; Simonyan, Ani; Sipala, Valeria; Slone, Oren; Smith, Elton; Snowden-Ifft, Daniel; Solt, Matthew; Sorensen, Peter; Soreq, Yotam; Spagnolo, Stefania; Spencer, James; Stepanyan, Stepan; Strube, Jan; Sullivan, Michael; Tadepalli, Arun S.; Tait, Tim; Taiuti, Mauro; Tanedo, Philip; Tayloe, Rex; Thaler, Jesse; Tran, Nhan V.; Tulin, Sean; Tully, Christopher G.; Uemura, Sho; Ungaro, Maurizio; Valente, Paolo; Vance, Holly; Vavra, Jerry; Volansky, Tomer; von Krosigk, Belina; Whitbeck, Andrew; Williams, Mike; Wittich, Peter; Wojtsekhowski, Bogdan; Xue, Wei; Yoon, Jong Min; Yu, Hai-Bo; Yu, Jaehoon; Yu, Tien-Tien; Zhang, Yue; Zhao, Yue; Zhong, Yiming; Zurek, Kathryn
Comments: 66 pages, 15 figures, 3 tables. Workshop website and agenda: http://www-conf.slac.stanford.edu/darksectors2016/ https://indico.cern.ch/event/507783/ Editors: J. Alexander, M. Battaglieri, B. Echenard, R. Essig, M. Graham, E. Izaguirre, J. Jaros, G. Krnjaic, J. Mardon, D. Morrissey, T. Nelson, M. Perelstein, M. Pyle, A. Ritz, P. Schuster, B. Shuve, N. Toro, R. Van De Water
Submitted: 2016-08-30
This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years.
[13]  oai:arXiv.org:1503.03379  [pdf] - 1458536
Dark matter effective field theory scattering in direct detection experiments
Comments: Newest version includes erratum
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.
[14]  oai:arXiv.org:1509.02448  [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
Comments: 6 pages, 4 figures. v2 Matches the accepted version in PRL
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[15]  oai:arXiv.org:1504.05871  [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Comments: 25 pages, 15 figures, slightly updated organization and text consistent with PRD referee process, Fig. 14 updated
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there were zero candidate events above a deposited energy of 10 keV and 6 events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and $1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$ WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[16]  oai:arXiv.org:1503.01200  [pdf] - 951863
Optimized Designs for Very Low Temperature Massive Calorimeters
Comments: 16 pages, 12 figures
Submitted: 2015-03-03, last modified: 2015-03-12
The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study of several calorimetric detectors suggests that a mismatch between the sensor and signal bandwidths is the primary reason for suppressed sensitivity. With this understanding, we propose a detector design in which a thin-film Au pad is directly deposited onto a massive absorber that is then thermally linked to a separately fabricated TES chip via an Au wirebond, providing large electron-phonon coupling (i.e. high signal bandwidth), ease of fabrication, and cosmogenic background suppression. Interestingly, this design strategy is fully compatible with the use of hygroscopic crystals (NaI) as absorbers. An 80-mm diameter Si light detector based upon these design principles, with potential use in both dark matter and neutrinoless double beta decay, has an estimated baseline energy resolution of 0.35 eV, 20$\times$ better than currently achievable. A 1.75 kg ZnMoO$_{4}$ large-mass calorimeter would have a 3.5 eV baseline resolution, 1000$\times$ better than currently achieved with NTDs with an estimated position dependence $\frac{\Delta E}{E}$ of 6$\times$10$^{-4}$. Such minimal position dependence is made possible by forcing the sensor bandwidth to be much smaller than the signal bandwidth. Further, intrinsic event timing resolution is estimated to be $\sim$170 $\mu$s for 3 MeV recoils in the phonon detector, satisfying the event-rate requirements of large $Q_{\beta \beta}$ next-generation neutrinoless double beta decay experiments. Quiescent bias power for both of these designs is found to be significantly larger than parasitic power loads achieved in the SPICA/SAFARI infrared bolometers.
[17]  oai:arXiv.org:1409.3270  [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Comments: 5 pages, 6 figures, submitted to PRL
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
[18]  oai:arXiv.org:1410.1003  [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Comments: 12 pages, 12 figures, submitted to PRD
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
[19]  oai:arXiv.org:1402.7137  [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Comments: 6 pages, 4 figures; figure 1 updated, submitted to Phys. Rev. Lett
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
[20]  oai:arXiv.org:1309.3259  [pdf] - 779590
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Comments: 7 pages, 4 figures
Submitted: 2013-09-12, last modified: 2013-12-20
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
[21]  oai:arXiv.org:1304.4279  [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Comments: 5 pages, 4 figures, as accepted by PRL
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[22]  oai:arXiv.org:1305.2405  [pdf] - 1530127
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Comments: 5 pages, 4 figures, submitted to journal
Submitted: 2013-05-10, last modified: 2013-10-04
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
[23]  oai:arXiv.org:1304.3706  [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
Comments: 5 pages, 4 figures; updated to match published version
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10 GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.
[24]  oai:arXiv.org:1203.1309  [pdf] - 564223
Search for annual modulation in low-energy CDMS-II data
Comments: 5 pages, plus 8 pages supplementary materials
Submitted: 2012-03-06, last modified: 2012-09-18
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactions consistent with nuclear recoils, and constrain the magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9 keVnr energy range at the 99% confidence level. These results disfavor an explanation for the reported modulation in the 1.2-3.2 keVee energy range in CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs at >98% confidence. For events consistent with electron recoils, no significant modulation is observed for either single- or multiple-detector interactions in the 3.0-7.4 keVee range.
[25]  oai:arXiv.org:1201.3685  [pdf] - 1093064
Low-Mass WIMP Sensitivity and Statistical Discrimination of Electron and Nuclear Recoils by Varying Luke-Neganov Phonon Gain in Semiconductor Detectors
Comments: 6 pages, 5 figures To be published in Journal of Low Temperature Physics
Submitted: 2012-01-17
Amplifying the phonon signal in a semiconductor dark matter detector can be accomplished by operating at high voltage bias and converting the electrostatic potential energy into Luke-Neganov phonons. This amplification method has been validated at up to |E|=40V/cm without producing leakage in CDMSII Ge detectors, allowing sensitivity to a benchmark WIMP with mass = 8GeV and cross section 1.8e-42cm^2 assuming flat electronic recoil backgrounds near threshold. Furthermore, for the first time we show that differences in Luke-Neganov gain for nuclear and electronic recoils can be used to discriminate statistically between low-energy background and a hypothetical WIMP signal by operating at two distinct voltage biases. Specifically, 99% of events have p-value<1e-8 for a simulated 20kg-day experiment with a benchmark WIMP signal with mass =8GeV and cross section =3.3e-41cm^2.
[26]  oai:arXiv.org:1109.3620  [pdf] - 967055
Modeling phase-separated transition-edge sensors in SuperCDMS detectors
Comments: 13 pages, 10 figures, submitted to Nuclear Instruments and Methods in Physics Research Section A
Submitted: 2011-09-16, last modified: 2011-09-23
The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters to data, which reproduces superconducting-to-normal phase separation within a TES. This tuning provides insight into the behavior of the TESs, allows us to study the phase-separation length to optimize our detector design, and is integrated into a more complete simulation of the phonon and charge physics of SuperCDMS detectors.
[27]  oai:arXiv.org:1109.4343  [pdf] - 1934627
Phonon Pulse Shape Discrimination in SuperCDMS Soudan
Comments: Low Temperature Detector 14 conference proceedings, to be published in a special issue of the Journal of Low Temperature Physics
Submitted: 2011-09-20
SuperCDMS is the next phase of the Cryogenic Dark Matter Search experiment, which measures both phonon and charge signals generated by particle recoils within a germanium target mass. Charge signals are employed both in the definition of a fiducial volume and in the rejection of electron recoil background events. Alternatively, phonons generated by the charge carriers can also be used for the same two goals. This paper describes preliminary efforts to observe and quantify these contributions to the phonon signal and then use them to reject background events. A simple analysis using only one pulse shape parameter shows bulk electron recoil vs. bulk nuclear recoil discrimination to the level of 1:10^3 (limited by the statistics of the data), with little degradation in discrimination ability down to at least 7 keV recoil energy. Such phonon-only discrimination can provide a useful cross-check to the standard discrimination methods, and it also points towards the potential of a device optimized for a phonon-only measurement.
[28]  oai:arXiv.org:1109.1198  [pdf] - 1083866
Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with low Transition-Edge-Sensor Transition Temperature
Comments:
Submitted: 2011-09-06
We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels. The phonon energy is then parsed into TES based phonon readout channels and input into a TES simulator.
[29]  oai:arXiv.org:1109.1327  [pdf] - 1937687
Simulations of Noise in Phase-Separated Transition-Edge Sensors for SuperCDMS
Comments: Low Temperature Detector 14 conference proceedings to be published in the Journal of Low Temperature Physics, 6 pages, 4 figures
Submitted: 2011-09-06
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations are valuable for optimizing the critical temperature and TES length of future SuperCDMS detectors.
[30]  oai:arXiv.org:1109.0551  [pdf] - 1934625
Validation of Phonon Physics in the CDMS Detector Monte Carlo
Comments: 6 Pages, 5 Figures, Proceedings of Low Temperature Detectors 14 Conference
Submitted: 2011-09-02
The SuperCDMS collaboration is a dark matter search effort aimed at detecting the scattering of WIMP dark matter from nuclei in cryogenic germanium targets. The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at achieving a deeper understanding of the performance of the SuperCDMS detectors and aiding the dark matter search analysis. We present results from validation of the phonon physics described in the CDMS-DMC and outline work towards utilizing it in future WIMP search analyses.
[31]  oai:arXiv.org:1108.6244  [pdf] - 1934623
Time Evolution of Electric Fields in CDMS Detectors
Comments: Low Temperature Detectors 14 conference proceeding to be published in the Journal of Low Temperature Physics
Submitted: 2011-08-31
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter x 1" thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors, the later providing a $\sim$1 V cm$^{-1}$ electric field in the detector bulk. Cumulative radiation exposure which creates $\sim 200\times 10^6$ electron-hole pairs is sufficient to produce a comparable reverse field in the detector thereby degrading the ionization channel performance. To study this, the existing CDMS detector Monte Carlo has been modified to allow for an event by event evolution of the bulk electric field, in three spatial dimensions. Our most resent results and interpretation are discussed.
[32]  oai:arXiv.org:1105.3377  [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS; Collaborations, EDELWEISS; :; Ahmed, Z.; Akerib, D. S.; Armengaud, E.; Arrenberg, S.; Augier, C.; Bailey, C. N.; Balakishiyeva, D.; Baudis, L.; Bauer, D. A.; Benoît, A.; Bergé, L.; Blümer, J.; Brink, P. L.; Broniatowski, A.; Bruch, T.; Brudanin, V.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Censier, B.; Chapellier, M.; Chardin, G.; Charlieux, F.; Cooley, J.; Coulter, P.; Cox, G. A.; Cushman, P.; Daal, M.; Defay, X.; De Jesus, M.; DeJongh, F.; Di Stefano, P. C. F.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.; Dragowsky, M. R.; Eitel, K.; Fallows, S.; Figueroa-Feliciano, E.; Filippini, J.; Filosofov, D.; Fourches, N.; Fox, J.; Fritts, M.; Gascon, J.; Gerbier, G.; Gironnet, J.; Golwala, S. R.; Gros, M.; Hall, J.; Hennings-Yeomans, R.; Henry, S.; Hertel, S. A.; Hervé, S.; Holmgren, D.; Hsu, L.; Huber, M. E.; Juillard, A.; Kamaev, O.; Kiveni, M.; Kluck, H.; Kos, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Leman, S. W.; Liu, S.; Loaiza, P.; Mahapatra, R.; Mandic, V.; Marnieros, S.; Martinez, C.; McCarthy, K. A.; Mirabolfathi, N.; Moore, D.; Nadeau, P.; Navick, X-F.; Nelson, H.; Nones, C.; Ogburn, R. W.; Olivieri, E.; Pari, P.; Pattavina, L.; Paul, B.; Phipps, A.; Pyle, M.; Qiu, X.; Rau, W.; Reisetter, A.; Ricci, Y.; Robinson, M.; Rozov, S.; Saab, T.; Sadoulet, B.; Sander, J.; Sanglard, V.; Schmidt, B.; Schnee, R. W.; Scorza, S.; Seitz, D. N.; Semikh, S.; Serfass, B.; Sundqvist, K. M.; Tarka, M.; Torrento-Coello, A. S.; Vagneron, L.; Verdier, M. -A.; Walker, R. J.; Wikus, P.; Yakushev, E.; Yellin, S.; Yoo, J.; Young, B. A.; Zhang, J.
Comments: Events, efficiencies, and main limit are available in text format (see README.txt)
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
[33]  oai:arXiv.org:1012.5078  [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
Comments: 10 pages, 10 figures, minor changes to match published version, conclusion unchanged
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.
[34]  oai:arXiv.org:1011.2482  [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
Comments: 9 pages, 8 figures. Supplemental material included as ancillary files. v3) Added appendix with additional details regarding energy scale and backgrounds
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.
[35]  oai:arXiv.org:1004.1233  [pdf] - 144976
Oblique propagation of electrons in crystals of germanium and silicon at sub-Kelvin temperature in low electric fields
Comments: 3 pages, 3 figures, submitted for publication
Submitted: 2010-04-07
We show that oblique propagation of electrons in crystals of Ge and Si, where the electron velocity does not follow the electric field even on average, can be explained using standard anisotropic theory for indirect gap semiconductors. These effects are pronounced at temperatures below ~1K and for electric fields below ~5V/cm because inter-valley transitions are energetically suppressed forcing electrons to remain in the same band valley throughout their motion and the valleys to separate in position space. To model, we start with an isotropic approximation which incorporates the average properties of the crystals with one phonon mode, and include the ellipsoidal electron valleys by transforming into a momentum space where constant energy surfaces are spheres. We include comparisons of simulated versus measured drift velocities for holes and electrons, and explain the large discrepancy between electrons and holes for shared events in adjacent electrodes.
[36]  oai:arXiv.org:0907.1438  [pdf] - 142195
Analysis of the low-energy electron-recoil spectrum of the CDMS experiment
Comments: 4 pages, 3 figures
Submitted: 2009-07-09
We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2 - 8.5 keV. We find no significant excess in the counting rate above background, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z^2 scaling. With this assumption the observed rate in DAMA differs from the upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of ~2 less than observed by DAMA, constraining some possible interpretations of this modulation.