Normalized to: Puimedon, J.
[1]
oai:arXiv.org:1812.01377 [pdf] - 1890304
Analysis of backgrounds for the ANAIS-112 dark matter experiment
Amare, J.;
Cebrian, S.;
Coarasa, I.;
Cuesta, C.;
Garcia, E.;
Martinez, M.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Salinas, A.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2018-12-04, last modified: 2019-05-28
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at
the confirmation or refutation of theDAMA/LIBRA positive annual modulation
signal in the low energy detection rate, using the same target and technique,
at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS-112, consisting of
nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. in a 3x3matrix
configuration, is taking data smoothly in "dark matter search" mode since
August, 2017, after a commissioning phase and operation of the first detectors
during the last years in various setups. A large effort has been carried out
withinANAIS to characterize the background of sodium iodide detectors, before
unblinding the data and performing the first annual modulation analysis. Here,
the background models developed for all the nine ANAIS-112 detectors are
presented. Measured spectra from threshold to high energy in different
conditions are well described by the models based on quantified activities
independently estimated following several approaches. In the region from 1 to 6
keVee the measured, efficiency corrected background level is 3.58+-0.02 keV-1
kg-1 day-1; NaI crystal bulk contamination is the dominant background source
being 210Pb, 40K, 22Na and 3H contributions the most relevant ones. This
background level, added to the achieved 1 keVee analysis threshold (thanks to
the outstanding light collection and robust filtering procedures developed),
allow ANAIS-112 to be sensitive to the modulation amplitude measured by
DAMA/LIBRA, and able to explore at three sigma level in 5 years the WIMP
parameter region singled out by this experiment.
[2]
oai:arXiv.org:1706.05818 [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Amare, J.;
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Cuesta, C.;
Dafni, T.;
Galan, J.;
Garcia, E.;
Garza, J. G.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Martinez, M.;
Mirallas, H.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Ruiz-Choliz, E.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background
conditions at energies below a few tens of keV. Radioactive isotopes are
produced via cosmogenic activation in detectors and other materials and those
isotopes constitute a background source which has to be under control. In
particular, tritium is specially relevant due to its decay properties (very low
endpoint energy and long half-life) when induced in the detector medium, and
because it can be generated in any material as a spallation product.
Quantification of cosmogenic production of tritium is not straightforward,
neither experimentally nor by calculations. In this work, a method for the
calculation of production rates at sea level has been developed and applied to
some of the materials typically used as targets in dark matter detectors
(germanium, sodium iodide, argon and neon); it is based on a selected
description of tritium production cross sections over the entire energy range
of cosmic nucleons. Results have been compared to available data in the
literature, either based on other calculations or from measurements. The
obtained tritium production rates, ranging from a few tens to a few hundreds of
nuclei per kg and per day at sea level, point to a significant contribution to
the background in dark matter experiments, requiring the application of
specific protocols for target material purification, material storing
underground and limiting the time the detector is on surface during the
building process in order to minimize the exposure to the most dangerous cosmic
ray components.
[3]
oai:arXiv.org:1710.03837 [pdf] - 1589559
The ANAIS-112 experiment at the Canfranc Underground Laboratory
Amare, J;
Cebrian, S;
Coarasa, I;
Cuesta, C;
Garcia, E;
Martinez, M;
Olivan, M A;
Ortigoza, Y;
de Solorzano, A Ortiz;
Puimedon, J;
Salinas, A;
Sarsa, M L;
Villar, P;
Villar, J A
Submitted: 2017-10-10
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal at the
Canfranc Underground Laboratory (LSC). Several 12.5 kg NaI(Tl) modules produced
by Alpha Spectra Inc. have been operated there during the last years in various
set-ups; an outstanding light collection at the level of 15 photoelectrons per
keV, which allows triggering at 1 keV of visible energy, has been measured for
all of them and a complete characterization of their background has been
achieved. In the first months of 2017, the full ANAIS-112 set-up consisting of
nine Alpha Spectra detectors with a total mass of 112.5 kg was commissioned at
LSC and the first dark matter run started in August, 2017. Here, the latest
results on the detectors performance and measured background from the
commissioning run will be presented and the sensitivity prospects of the
ANAIS-112 experiment will be discussed.
[4]
oai:arXiv.org:1604.05587 [pdf] - 1460860
Assessment of backgrounds of the ANAIS experiment for dark matter direct
detection
Amare, J.;
Cebrian, S.;
Cuesta, C.;
Garcia, E.;
Martinez, M.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2016-04-19, last modified: 2016-07-22
A large effort has been carried out to characterize the background of sodium
iodide crystals within the ANAIS (Annual modulation with NaI Scintillators)
project. In this paper, the background models developed for three 12.5-kg
NaI(Tl) scintillators produced by Alpha Spectra Inc. and operated at the
Canfranc Underground Laboratory are presented together with an evaluation of
the background prospects for the full experiment. Measured spectra from
threshold to high energy in different conditions are well described by the
models based on quantified activities. At the region of interest, crystal bulk
contamination is the dominant background source. Contributions from 210Pb, 40K,
22Na and 3H are the most relevant. Those from 40K and 22Na could be efficiently
suppressed thanks to anticoincidence operation in a crystals matrix or inside a
Liquid Scintillator Veto (LSV), while that from 210Pb has been reduced by
improving crystal production methods and 3H production could be reduced by
shielding against cosmic rays during production. Assuming the activities of the
last characterized detector, for nine crystals with a total mass of 112.5 kg
the expected background rate is 2.5 counts/(keV kg d) in the region from 1 to 4
keV, which could be reduced at 1.4 counts/(keV kg d) by using a LSV.
[5]
oai:arXiv.org:1508.07213 [pdf] - 1268010
Status of the ANAIS Dark Matter Project at the Canfranc Underground
Laboratory
Amare, J.;
Cebrian, S.;
Cuesta, C.;
Garcia, E.;
Martinez, M.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Pobes, C.;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2015-08-28
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal. A
detailed analysis of two NaI(Tl) crystals of 12.5 kg each grown by Alpha
Spectra will be shown: effective threshold at 1 keVee is at reach thanks to
outstanding light collection and robust PMT noise filtering protocols and the
measured background is well understood down to 3 keVee, having quantified K, U
and Th content and cosmogenic activation in the crystals. A new detector was
installed in Canfranc in March 2015 together with the two previous modules and
preliminary characterization results will be presented. Finally, the status and
expected sensitivity of the full experiment with 112 kg will be reviewed.
[6]
oai:arXiv.org:1410.5949 [pdf] - 886494
ANAIS: Status and prospects
Amare, J.;
Cebrian, S.;
Cuesta, C.;
Garcia, E.;
Ginestra, C.;
Martinez, M.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Pobes, C.;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2014-10-22
ANAIS (Annual modulation with NAI Scintillators) experiment aims to look for
dark matter annual modulation with 250 kg of ultrapure NaI(Tl) scintillators at
the Canfranc Underground Laboratory (LSC), in order to confirm the DAMA/LIBRA
positive signal in a model-independent way. The detector will consist in an
array of close-packed single modules, each of them coupled to two high
efficiency Hamamatsu photomultipliers. Two 12.5 kg each NaI(Tl) crystals
provided by Alpha Spectra are currently taking data at the LSC. These modules
have shown an outstanding light collection efficiency (12-16 phe/keV), about
the double of that from DAMA/LIBRA phase 1 detectors, which could enable
reducing the energy threshold down to 1 keVee. ANAIS crystal radiopurity goals
are fulfilled for 232Th and 238U chains, assuming equilibrium, and in the case
of 40K, present crystals activity (although not at the required 20 ppb level)
could be acceptable. However, a 210Pb contamination out-of-equilibrium has been
identified and its origin traced back, so we expect it will be avoided in next
prototypes. Finally, current status and prospects of the experiment considering
several exposure and background scenarios are presented.
[7]
oai:arXiv.org:1403.5114 [pdf] - 1175712
Radiopurity of CaWO$_4$ Crystals for Direct Dark Matter Search with
CRESST and EURECA
Münster, A.;
Sivers, M. v.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Laubenstein, M.;
Loebell, J.;
Ortigoza, Y.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puimedon, J.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-03-20, last modified: 2014-05-07
The direct dark matter search experiment CRESST uses scintillating CaWO$_4$
single crystals as targets for possible WIMP scatterings. An intrinsic
radioactive contamination of the crystals as low as possible is crucial for the
sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST
were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$
crystals have also been grown at the crystal laboratory of the Technische
Universit\"at M\"unchen (TUM) to better meet the requirements of CRESST and of
the future tonne-scale multi-material experiment EURECA. The radiopurity of the
raw materials and of first TUM-grown crystals was measured by ultra-low
background $\gamma$-spectrometry. Two TUM-grown crystals were also operated as
low-temperature detectors at a test setup in the Gran Sasso underground
laboratory. These measurements were used to determine the crystals' intrinsic
$\alpha$-activities which were compared to those of crystals produced at other
institutes. The total $\alpha$-activities of TUM-grown crystals as low as 1.23
$\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of
crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35
mBq/kg.
[8]
oai:arXiv.org:1403.3539 [pdf] - 1208389
Scintillating bolometers: a key for determining WIMP parameters
Cerdeno, D. G.;
Cuesta, C.;
Fornasa, M.;
Garcia, E.;
Ginestra, C.;
Marcos, C.;
Martinez, M.;
Ortigoza, Y.;
Peiro, M.;
Puimedon, J.;
Sarsa, M. L.
Submitted: 2014-03-14, last modified: 2014-03-21
In the last decade direct detection Dark Matter (DM) experiments have
increased enormously their sensitivity and ton-scale setups have been proposed,
especially using germanium and xenon targets with double readout and background
discrimination capabilities. In light of this situation, we study the prospects
for determining the parameters of Weakly Interacting Massive Particle (WIMP) DM
(mass, spin-dependent (SD) and spin-independent (SI) cross section off
nucleons) by combining the results of such experiments in the case of a
hypothetical detection. In general, the degeneracy between the SD and SI
components of the scattering cross section can only be removed using targets
with different sensitivities to these components. Scintillating bolometers,
with particle discrimination capability, very good energy resolution and
threshold and a wide choice of target materials, are an excellent tool for a
multitarget complementary DM search. We investigate how the simultaneous use of
scintillating targets with different SD-SI sensitivities and/or light isotopes
(as the case of CaF2 and NaI) significantly improves the determination of the
WIMP parameters. In order to make the analysis more realistic we include the
effect of uncertainties in the halo model and in the spin-dependent nuclear
structure functions, as well as the effect of a thermal quenching different
from 1.
[9]
oai:arXiv.org:1304.1758 [pdf] - 1165774
Complementarity of dark matter direct detection: the role of bolometric
targets
Cerdeno, D. G.;
Cuesta, C.;
Fornasa, M.;
Garcia, E.;
Ginestra, C.;
Huh, Ji-Haeng;
Martinez, M.;
Ortigoza, Y.;
Peiro, M.;
Puimedon, J.;
Robledo, L.;
Sarsa, M. L.
Submitted: 2013-04-05
We study how the combined observation of dark matter in various direct
detection experiments can be used to determine the phenomenological properties
of WIMP dark matter: mass, spin-dependent (SD) and spin-independent (SI)
scattering cross section off nucleons. A convenient choice of target materials,
including nuclei that couple to dark matter particles through a significantly
different ratio of SD vs SI interactions, could break the degeneracies in the
determination of those parameters that a single experiment cannot discriminate.
In this work we investigate different targets that can be used as scintillating
bolometers and could provide complementary information to germanium and xenon
detectors. We observe that Al2O3 and LiF bolometers could allow a good
reconstruction of the DM properties over regions of the parameter space with a
SD scattering cross section as small as 10^(-5) pb and a SI cross section as
small as 5x10^(-10) pb for a 50 GeV WIMP. In the case of a CaWO4 bolometer the
area in which full complementarity is obtained is smaller but we show that it
can be used to determine the WIMP mass and its SI cross section. For each
target we study the required exposure and background.
[10]
oai:arXiv.org:astro-ph/0211535 [pdf] - 1591945
Status of IGEX dark matter search at Canfranc Underground Laboratory
Irastorza, I. G.;
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Carmona, J. M.;
Cebrian, S.;
Garcia, E.;
Kirpichnikov, I. V.;
Klimenko, A. A.;
Luzon, G.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Osetrov, S. B.;
Pogosov, V. S.;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Smolnikov, A. A.;
Tamanyan, A. G.;
Vasenko, A. A.;
Vasiliev, S. I.;
Villar, J. A.
Submitted: 2002-11-25
One IGEX 76Ge double-beta decay detector is currently operating in the
Canfranc Underground Laboratory in a search for dark matter WIMPs, through the
Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we
report on the on-going efforts to understand and eventually reject the
background at low energy. These efforts have led to the improvement of the
neutron shielding and to partial reduction of the background, but still the
remaining events are not totally identified. A tritium contamination or
muon-induced neutrons are considered as possible sources, simulations and
experimental test being still under progress. According to the success of this
study we comment the prospects of the experiment as well as those of its future
extension, the GEDEON dark matter experiment.
[11]
oai:arXiv.org:astro-ph/0112272 [pdf] - 1232796
The ROSEBUD experiment at Canfranc: 2001 report
Cebrian, S.;
Coron, N.;
Dambier, G.;
Garcia, E.;
Irastorza, I. G.;
Leblanc, J.;
de Marcillac, P.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 2001-12-12, last modified: 2002-01-03
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in
the Canfranc Underground Laboratory. The first phase of the experiment was
dedicated to the understanding and reduction of the radioactive background
following successive removals of the radioimpure materials. Sapphire (25g, 50g)
and germanium (67g) absorbers were used. Thresholds respectively lower than
1keV and 450 eV were achieved on these detectors. The second phase of the
experiment plans to use scintillating bolometers to discriminate between
recoiling nuclei and electrons. Prototypes using commercial CaWO4 (54g) and BGO
(46g) were designed for this purpose. While internal contamination was found
and identified in both targets, neutron calibrations revealed their high
discrimination power. A 6 keV threshold on the heat channel of the BGO
bolometer points out the interest of such a novel material, for Dark Matter
research on neutralinos having spin-dependent or spin-independent interactions.
[12]
oai:arXiv.org:hep-ex/0101037 [pdf] - 113338
Particle Dark Matter and Solar Axion Searches with a small germanium
detector at the Canfranc Underground Laboratory
Morales, A.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2001-01-22
A small, natural abundance, germanium detector (COSME) has been operating
recently at the Canfranc Underground Laboratory (Spanish Pyrenees) in improved
conditions of shielding and overburden with respect to a previous operation of
the same detector. An exposure of 72.7 kg day in these conditions has at
present a background improvement of about one order of magnitude compared to
the former operation of the detector. These new data have been applied to a
direct search for WIMPs and solar axions. New WIMP exclusion plots improving
the current bounds for low masses are reported. The paper also presents a limit
on the axion-photon coupling obtained from the analysis of the data looking for
a Primakoff axion-to-photon conversion and Bragg scattering inside the crystal.
[13]
oai:arXiv.org:hep-ph/0011318 [pdf] - 1507915
Recent results from the canfranc dark matter search with germanium
detectors
Irastorza, I. G.;
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Hensley, W. K.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2000-11-27
Two germanium detectors are currently operating in the Canfranc Underground
Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX
detector (RG-2) which has an energy threshold of 4 keV and a low-energy
background rate of about 0.3 c/keV/kg/day. The other is a small (234 g) natural
abundance Ge detector (COSME), of low energy threshold (2.5 keV) and an energy
resolution of 0.4 keV at 10 keV which is looking for WIMPs and for solar
axions. The analysis of 73 kg-days of data taken by COSME in a search for solar
axions via their photon Primakoff conversion and Bragg scattering in the Ge
crystal yields a 95% C.L. limit for the axion-photon coupling g < 2.8 10^-9
GeV^-1. These data, analyzed for WIMP searches provide an exclusion plot for
WIMP-nucleon spin-independent interaction which improves previous plots in the
low mass region. On the other hand, the exclusion plot derived from the 60
kg-days of data from the RG-2 IGEX detector improves the exclusion limits
derived from other ionization (non thermal) germanium detector experiments in
the region of WIMP masses from 30 to 100 GeV recently singled out by the
reported DAMA annual modulation effect.
[14]
oai:arXiv.org:astro-ph/0004292 [pdf] - 362880
First results of the ROSEBUD Dark Matter experiment
Cebrian, S.;
Coron, N.;
Dambier, G.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Leblanc, J.;
de Marcillac, P.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2000-04-20
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which
attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through
their elastic scattering off Al and O nuclei. It consists of three small
sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a
dilution refrigerator operating at 20 mK in the Canfranc Underground
Laboratory. We report in this paper the results of several runs (of about 10
days each) with successively improved energy thresholds, and the progressive
background reduction obtained by improvement of the radiopurity of the
components and subsequent modifications in the experimental assembly, including
the addition of old lead shields. Mid-term plans and perspectives of the
experiment are also presented.
[15]
oai:arXiv.org:hep-ex/0002053 [pdf] - 113328
New constraints on WIMPs from the Canfranc IGEX dark matter search
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Hensley, W. K.;
Irastorza, I. G.;
Kirpichnikov, I. V.;
Klimenko, A. A.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Osetrov, S. B.;
Pogosov, V. S.;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Smolnikov, A. A.;
Tamanyan, A. G.;
Vasenko, A. A.;
Vasiliev, S. I.;
Villar, J. A.
Submitted: 2000-02-21
The IGEX Collaboration enriched 76Ge double-beta decay detectors are
currently operating in the Canfranc Underground Laboratory with an overburden
of 2450 m.w.e. A recent upgrade has made it possible to use them in a search
for WIMPs. A new exclusion plot has been derived for WIMP-nucleon
spin-independent interaction. To obtain this result, 30 days of data from one
IGEX detector, which has an energy threshold of ~4 keV, have been considered.
These data improve the exclusion limits derived from other germanium diode
experiments in the ~50 GeV DAMA region, and show that with a moderate
improvement of the background below 10 keV, the DAMA region may be tested with
an additional 1 kg-year of exposure.
[16]
oai:arXiv.org:hep-ph/9912522 [pdf] - 116658
Sensitivity plots for WIMP modulation searches
Scopel, S.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 1999-12-28
Prospects of WIMP searches using the annual modulation signature are
discussed on statistical grounds, introducing sensitivity plots for the
WIMP-nucleon scalar cross section.
[17]
oai:arXiv.org:astro-ph/9912491 [pdf] - 110154
Prospects for solar axions searches with crystals via Bragg scattering
Irastorza, I. G.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 1999-12-23
A calculation of the expected signal due to Primakov coherent conversion of
solar axions into photons via Bragg scattering in several solid-state detectors
is presented and compared with present and future experimental sensitivities.
The axion window m_a > 0.03 eV (not accessible at present by other techniques)
could be explored in the foreseeable future with crystal detectors to constrain
the axion-photon coupling constant below the latest bounds coming from
helioseismology. On the contrary a positive signal in the sensitivity region of
such devices would imply revisiting other more stringent astrophysical limits
derived for the same range of the axion mass. The application of this technique
to the COSME germanium detector which is taking data at the Canfranc
Underground Laboratory leads to a 95% C.L. limit g_a < 2.8 10^-9 GeV^-1.
[18]
oai:arXiv.org:hep-ph/9912394 [pdf] - 899146
Sensitivity plots for WIMP direct detection using the annual modulation
signature
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Peruzzi, A.;
Puimedon, J.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 1999-12-17
Annual modulation due to the Earth's motion around the Sun is a well known
signature of the expected WIMP signal induced in a solid state underground
detector. In the present letter we discuss the prospects of this technique on
statistical grounds, introducing annual-modulation sensitivity plots for the
WIMP-nucleon scalar cross section for different materials and experimental
conditions. The highest sensitivity to modulation is found in the WIMP mass
interval 10 GeV< m_W < 130 GeV, the actual upper limit depending from the
choice of the astrophysical parameters, while the lowest values of the
explorable WIMP-nucleon elastic cross-sections fall in most cases within one
order of magnitude of the sensitivities of present direct detection WIMP
searches.
[19]
oai:arXiv.org:astro-ph/9811359 [pdf] - 103985
Prospects of solar axion searches with crystal detectors
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Salinas, A.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 1998-11-23
A calculation of the expected signal due to Primakoff coherent conversion of
solar axions into photons via Bragg scattering in several crystal detectors is
presented. The results are confronted with the experimental sensitivities of
present and future experiments concluding that the sensitivity of crystal
detectors does not challenge the globular cluster limit on the axion-photon
coupling g_a. In particular, in the axion mass window m_a ~> 0.03 eV explored
with this technique (not accessible at present by other methods) g_a might be
constrained down to 10^-9 GeV^-1 (the recent helioseismological bound) provided
that significant improvements in the parameters and performances of these
detectors be achieved and large statistics accumulated. This bound should be
considered as a minimal goal for the sensitivity of future crystal experiments.
Consequently, finding a positive signal at this level of sensitivity would
necessarily imply revisiting other more stringent astrophysical limits derived
for the same range of m_a values.
[20]
oai:arXiv.org:astro-ph/9810308 [pdf] - 103424
Theoretical expectations and experimental prospects for solar axions
searches with crystal detectors
Scopel, S.;
Irastorza, I. G.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Salinas, A.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 1998-10-20
A calculation of the expected signal due to Primakov coherent conversion of
solar axions into photons via Bragg scattering in several solid--state
detectors is presented and compared with present and future experimental
sensitivities. The axion window m_a>~0.03 eV (not accessible at present by
other techniques) could be explored in the foreseeable future with crystal
detectors to constrain the axion--photon coupling constant below the latest
bounds coming from helioseismology. On the contrary a positive signal in the
sensitivity region of such devices would imply revisiting other more stringent
astrophysical limits derived for the same range of the axion mass.
[21]
oai:arXiv.org:astro-ph/9809018 [pdf] - 102722
Search for an annual modulation of dark-matter signals with a germanium
spectrometer at the Sierra Grande Laboratory
Abriola, D.;
Avignone, F. T.;
Brodzinski, R. L.;
Collar, J. I.;
Di Gregorio, D. E.;
Farach, H. A.;
Garcia, E.;
Gattone, A. O.;
Guerard, C. K.;
Hasenbalg, F.;
Huck, H.;
Miley, H. S.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Salinas, A.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 1998-09-02, last modified: 1998-09-14
Data collected during three years with a germanium spectrometer at the Sierra
Grande underground laboratory have been analyzed for distinctive features of
annual modulation of the signal induced by WIMP dark matter candidates. The
main motivation for this analysis was the recent suggestion by the DAMA/NaI
Collaboration that a yearly modulation signal could not be rejected at the 90%
confidence level when analyzing data obtained with a high-mass low-background
scintillator detector. We performed two different analyses of the data: First,
the statistical distribution of modulation-significance variables (expected
from an experiment running under the conditions of Sierra Grande) was compared
with the same variables obtained from the data. Second, the data were analyzed
in energy bins as an independent check of the first result and to allow for the
possibility of a crossover in the expected signal. In both cases no
statistically significant deviation from the null result was found, which could
support the hypothesis that the data contain a modulated component. A plot is
also presented to enable the comparison of these results to those of the DAMA
collaboration.