Normalized to: Puig, R.
[1]
oai:arXiv.org:1711.07692 [pdf] - 1591519
First results on low-mass dark matter from the CRESST-III experiment
CRESST collaboration;
Petricca, F.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Lagenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-21
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in
Italy, searches for dark matter particles via their elastic scattering off
nuclei in a target material. The CRESST target consists of scintillating
CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin
temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon
signal and a light signal that is measured by a second cryogenic calorimeter.
Since the CRESST-II result in 2015, the experiment is leading the field of
direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$,
extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For
CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized
to reach the performance required to further probe the low-mass region with
unprecedented sensitivity. In this contribution the achievements of the
CRESST-III detectors will be discussed together with preliminary results and
perspectives of Phase 1.
[2]
oai:arXiv.org:1711.01482 [pdf] - 2082284
Results of the first NaI scintillating calorimeter prototypes by COSINUS
COSINUS collaboration;
Reindl, F.;
Angloher, G.;
Carniti, P.;
Cassina, L.;
Gironi, L.;
Gotti, C.;
Gütlein, A.;
Maino, M.;
Mancuso, M.;
Di Marco, N.;
Pagnanini, L.;
Pessina, G.;
Petricca, F.;
Pirro, S.;
Pröbst, F.;
Puig, R.;
Schäffner, K.;
Schieck, J.
Submitted: 2017-11-04
Over almost three decades the TAUP conference has seen a remarkable momentum
gain in direct dark matter search. An important accelerator were first
indications for a modulating signal rate in the DAMA/NaI experiment reported in
1997. Today the presence of an annual modulation, which matches in period and
phase the expectation for dark matter, is supported at > 9$\sigma$ confidence.
The underlying nature of dark matter, however, is still considered an open and
fundamental question of particle physics. No other direct dark matter search
could confirm the DAMA claim up to now; moreover, numerous null-results are in
clear contradiction under so-called standard assumptions for the dark matter
halo and the interaction mechanism of dark with ordinary matter. As both bear a
dependence on the target material, resolving this controversial situation will
convincingly only be possible with an experiment using sodium iodide (NaI) as
target. COSINUS aims to even go a step further by combining NaI with a novel
detection approach. COSINUS aims to operate NaI as a cryogenic calorimeter
reading scintillation light and phonon/heat signal. Two distinct advantages
arise from this approach, a substantially lower energy threshold for nuclear
recoils and particle identification on an event-by-event basis. These key
benefits will allow COSINUS to clarify a possible nuclear recoil origin of the
DAMA signal with comparatively little exposure of O(100kg days) and, thereby,
answer a long-standing question of particle physics. Today COSINUS is in R&D
phase; in this contribution we show results from the 2nd prototype, albeit the
first one of the final foreseen detector design. The key finding of this
measurement is that pure, undoped NaI is a truly excellent scintillator at low
temperatures: We measure 13.1% of the total deposited energy in the NaI crystal
in the form of scintillation light (in the light detector).
[3]
oai:arXiv.org:1711.01285 [pdf] - 1590722
Search for low-mass Dark Matter with the CRESST Experiment
Kluck, H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-03
CRESST is a multi-stage experiment directly searching for dark matter (DM)
using cryogenic $\mathrm{CaWO_4}$ crystals. Previous stages established leading
limits for the spin-independent DM-nucleon cross section down to DM-particle
masses $m_\mathrm{DM}$ below $1\,\mathrm{GeV/c^2}$. Furthermore, CRESST
performed a dedicated search for dark photons (DP) which excludes new parameter
space between DP masses $m_\mathrm{DP}$ of $300\,\mathrm{eV/c^2}$ to
$700\,\mathrm{eV/c^2}$.
In this contribution we will discuss the latest results based on the previous
CRESST-II phase 2 and we will report on the status of the current CRESST-III
phase 1: in this stage we have been operating 10 upgraded detectors with
$24,\mathrm{g}$ target mass each and enhanced detector performance since summer
2016. The improved detector design in terms of background suppression and
reduction of the detection threshold will be discussed with respect to the
previous stage. We will conclude with an outlook on the potential of the next
stage, CRESST-III phase 2.
[4]
oai:arXiv.org:1707.06749 [pdf] - 1586208
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter
operated above ground
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, A. Langenkämper J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Oberauer, L.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoglu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-07-20, last modified: 2017-09-18
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
[5]
oai:arXiv.org:1702.08861 [pdf] - 1581679
First Demonstration of a Scintillating Xenon Bubble Chamber for
Detecting Dark Matter and Coherent Elastic Neutrino-Nucleus Scattering
Baxter, D.;
Chen, C. J.;
Crisler, M.;
Cwiok, T.;
Dahl, C. E.;
Grimsted, A.;
Gupta, J.;
Jin, M.;
Puig, R.;
Temples, D.;
Zhang, J.
Submitted: 2017-02-28, last modified: 2017-06-08
A 30-g xenon bubble chamber, operated at Northwestern University in June and
November 2016, has for the first time observed simultaneous bubble nucleation
and scintillation by nuclear recoils in a superheated liquid. This chamber is
instrumented with a CCD camera for near-IR bubble imaging, a solar-blind
photomultiplier tube to detect 175-nm xenon scintillation light, and a
piezoelectric acoustic transducer to detect the ultrasonic emission from a
growing bubble. The time of nucleation determined from the acoustic signal is
used to correlate specific scintillation pulses with bubble-nucleating events.
We report on data from this chamber for thermodynamic "Seitz" thresholds from
4.2 to 15.0 keV. The observed single- and multiple-bubble rates when exposed to
a $^{252}$Cf neutron source indicate that, for an 8.3-keV thermodynamic
threshold, the minimum nuclear recoil energy required to nucleate a bubble is
$19\pm6$ keV (1$\sigma$ uncertainty). This is consistent with the observed
scintillation spectrum for bubble-nucleating events. We see no evidence for
bubble nucleation by gamma rays at any of the thresholds studied, setting a 90%
C.L. upper limit of $6.3\times10^{-7}$ bubbles per gamma interaction at a
4.2-keV thermodynamic threshold. This indicates stronger gamma discrimination
than in CF$_3$I bubble chambers, supporting the hypothesis that scintillation
production suppresses bubble nucleation by electron recoils while nuclear
recoils nucleate bubbles as usual. These measurements establish the
noble-liquid bubble chamber as a promising new technology for the detection of
weakly interacting massive particle dark matter and coherent elastic
neutrino-nucleus scattering.
[6]
oai:arXiv.org:1611.02113 [pdf] - 1509578
Direct Dark Matter Search with the CRESST II Experiment
Schieck, J;
Angloher, G;
Bento, A;
Bucci, C;
Canonica, L;
Defay, X;
Erb, A;
Feilitzsch, F v;
Iachellini, N Ferreiro;
Gorla, P;
Guetlein, A;
Hauff, D;
Jochum, J;
Kiefer, M;
Kluck, H;
Kraus, H;
Lanfranchi, J-C;
Loebell, J;
Mancuso, M;
Muenster, A;
Pagliarone, C;
Petricca, F;
Potzel, W;
Pröbst, F;
Puig, R;
Reindl, F;
Schaeffner, K;
Schoenert, S;
Seidel, W;
Stahlberg, M;
Stodolsky, L;
Strandhagen, C;
Strauss, R;
Tanzke, A;
Thi, H H Trinh;
Turkoglu, C;
Uffinger, M;
Ulrich, A;
Usherov, I;
Wawoczny, S;
Willers, M;
Wueustrich, M;
Zoeller, A
Submitted: 2016-11-07
The quest for the particle nature of dark matter is one of the big open
questions of modern physics. A well motivated candidate for dark matter is the
so-called WIMP - a weakly interacting massive particle. Recently several
theoretically well-motivated models with dark matter candidates in a mass
region below the WIMP mass-scale gained also a lot of interest, theoretically
and experimentally. The CRESST II experiment located at the Gran Sasso
laboratory in Italy is optimised for the detection of the elastic scattering of
these low-mass dark matter particles with ordinary matter. We show the results
obtained with an improved detector setup with increased radio purity and
enhanced background rejection and the results obtained with a dedicated
low-threshold analysis of a single conventional detector module. The limit
achieved is the most stringent limit achieved for direct dark matter
experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the
expected performance for new small CRESST-type detectors to be used during the
next data taking phase. We conclude with an outlook of the future potential for
direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic
detectors.