Normalized to: Proserpio, L.
[1]
oai:arXiv.org:1509.02298 [pdf] - 1273356
Profile reconstruction of grazing-incidence X-ray mirrors from
intra-focal X-ray full imaging
Spiga, D.;
Basso, S.;
Bavdaz, M.;
Burwitz, V.;
Civitani, M.;
Citterio, O.;
Ghigo, M.;
Hartner, G.;
Menz, B.;
Pareschi, G.;
Proserpio, L.;
Salmaso, B.;
Tagliaferri, G.;
Wille, E.
Submitted: 2015-09-08
The optics of a number of future X-ray telescopes will have very long focal
lengths (10 - 20 m), and will consist of a number of nested/stacked thin,
grazing-incidence mirrors. The optical quality characterization of a real
mirror can be obtained via profile metrology, and the Point Spread Function of
the mirror can be derived via one of the standard computation methods. However,
in practical cases it can be difficult to access the optical surfaces of
densely stacked mirror shells, after they have been assembled, using the
widespread metrological tools. For this reason, the assessment of the imaging
resolution of a system of mirrors is better obtained via a direct,
full-illumination test in X-rays. If the focus cannot be reached, an
intra-focus test can be performed, and the image can be compared with the
simulation results based on the metrology, if available. However, until today
no quantitative information was extracted from a full-illumination, intra-focal
exposure. In this work we show that, if the detector is located at an optimal
distance from the mirror, the intensity variations of the intra-focal,
full-illumination image in single reflection can be used to reconstruct the
profile of the mirror surface, without the need of a wavefront sensor. The
Point Spread Function can be subsequently computed from the reconstructed
mirror shape. We show the application of this method to an intra-focal (8 m
distance from mirror) test performed at PANTER on an optical module prototype
made of hot-slumped glass foils with a 20 m focal length, from which we could
derive an expected imaging quality near 16 arcsec HEW.
[2]
oai:arXiv.org:1502.03308 [pdf] - 1303946
Development of mirrors made of chemically tempered glass foils for
future X-ray telescopes
Submitted: 2015-02-11
Thin slumped glass foils are considered good candidates for the realization
of future X-ray telescopes with large effective area and high spatial
resolution. However, the hot slumping process affects the glass strength, and
this can be an issue during the launch of the satellite because of the high
kinematical and static loads occurring during that phase. In the present work
we have investigated the possible use of Gorilla glass (produced by Corning), a
chemical tempered glass that, thanks to its strength characteristics, would be
ideal. The un-tempered glass foils were curved by means of an innovative hot
slumping technique and subsequently chemically tempered. In this paper we show
that the chemical tempering process applied to Gorilla glass foils does not
affect the surface micro-roughness of the mirrors. On the other end, the stress
introduced by the tempering process causes a reduction in the amplitude of the
longitudinal profile errors with a lateral size close to the mirror length. The
effect of the overall shape changes in the final resolution performance of the
glass mirrors was studied by simulating the glass foils integration with our
innovative approach based on glass reinforcing ribs. The preliminary tests
performed so far suggest that this approach has the potential to be applied to
the X-ray telescopes of the next generation.
[3]
oai:arXiv.org:1402.3445 [pdf] - 1203354
Evaluation of the surface strength of glass plates shaped by hot
slumping process
Proserpio, L.;
Basso, S.;
Borsa, F.;
Citterio, O.;
Civitani, M.;
Ghigo, M.;
Pareschi, G.;
Salmaso, B.;
Sironi, G.;
Spiga, D.;
Tagliaferri, G.;
D'Este, A.;
Dall'Igna, R.;
Silvestri, M.;
Parodi, G.;
Martelli, F.;
Bavdaz, M.;
Wille, E.
Submitted: 2014-02-14, last modified: 2014-07-09
The Hot Slumping Technology is under development by several research groups
in the world for the realization of grazing-incidence segmented mirrors for
X-ray astronomy, based on thin glass plates shaped over a mould at temperatures
above the transformation point. The performed thermal cycle and related
operations might have effects on the strength characteristics of the glass,
with consequences on the structural design of the elemental optical modules and
consecutively on the entire X-ray optic for large astronomical missions like
IXO and ATHENA. The mechanical strength of glass plates after they underwent
the slumping process was tested through destructive double-ring tests in the
context of a study performed by the Astronomical Observatory of Brera with the
collaboration of Stazione Sperimentale del Vetro and BCV Progetti. The entire
study has been realized on more than 200 D263 Schott borosilicate glass
specimens of dimension 100 mm x 100 mm and thickness 0.4 mm, either flat or
bent at a Radius of Curvature of 1000 mm through the particular pressure
assisted hot slumping process developed by INAF-OAB. The collected experimental
data have been compared to non-linear FEM analyses and treated with Weibull
statistic to assess the current IXO glass X-ray telescope design, in terms of
survival probability, when subject to static and acoustic loads characteristic
of the launch phase. The paper describes the activities performed and presents
the obtained results.
[4]
oai:arXiv.org:0912.5331 [pdf] - 1018922
A wide field X-ray telescope for astronomical survey purposes: from
theory to practice
Submitted: 2009-12-29, last modified: 2010-02-11
X-ray mirrors are usually built in the Wolter I (paraboloid-hyperboloid)
configuration. This design exhibits no spherical aberration on-axis but suffers
from field curvature, coma and astigmatism, therefore the angular resolution
degrades rapidly with increasing off-axis angles. Different mirror designs
exist in which the primary and secondary mirror profiles are expanded as a
power series in order to increase the angular resolution at large off-axis
positions, at the expanses of the on-axis performances. Here we present the
design and global trade off study of an X-ray mirror systems based on
polynomial optics in view of the Wide Field X-ray Telescope (WFXT) mission.
WFXT aims at performing an extended cosmological survey in the soft X-ray band
with unprecedented flux sensitivity. To achieve these goals the angular
resolution required for the mission is very demanding ~5 arcsec mean resolution
across a 1-deg field of view. In addition an effective area of 5-9000 cm^2 at 1
keV is needed.