sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Prochaska, Travis

Normalized to: Prochaska, T.

5 article(s) in total. 35 co-authors, from 1 to 5 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1806.06390  [pdf] - 1739004
Systems engineering applied to ELT instrumentation: The GMACS case
Comments: To appear in Proc. SPIE 10705 (Ground-based and Airborne Instrumentation for Astronomy VII, SPIEastro18)
Submitted: 2018-06-17
An important tool for the development of the next generation of extremely large telescopes (ELTs) is a robust Systems Engineering (SE) methodology. GMACS is a first-generation multi-object spectrograph that will work at visible wavelengths on the Giant Magellan Telescope (GMT). In this paper, we discuss the application of SE to the design of next-generation instruments for ground-based astronomy and present the ongoing development of SE products for the GMACS spectrograph, currently in its Conceptual Design phase. SE provides the means to assist in the management of complex projects, and in the case of GMACS, to ensure its operational success, maximizing the scientific potential of GMT.
[2]  oai:arXiv.org:1407.8265  [pdf] - 1216036
Characterization of the Reflectivity of Various Black Materials
Comments:
Submitted: 2014-07-30
We present total and specular reflectance measurements of various materials that are commonly (and uncommonly) used to provide baffling and/or to minimize the effect of stray light in optical systems. More specifically, we investigate the advantage of using certain black surfaces and their role in suppressing stray light on detectors in optical systems. We measure the total reflectance of the samples over a broad wavelength range (250 < lambda < 2500 nm) that is of interest to astronomical instruments in the ultraviolet, visible, and near-infrared regimes. Additionally, we use a helium-neon laser to measure the specular reflectance of the samples at various angles. Finally, we compare these two measurements and derive the specular fraction for each sample.
[3]  oai:arXiv.org:1407.7537  [pdf] - 1215959
Mass production of volume phase holographic gratings for the VIRUS spectrograph array
Comments: 16 pages, 11 figures, 2 tables. To be published in Proc. SPIE, 2014, "Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation", 9151-53. The work presented in this article follows from arXiv:1207:4487
Submitted: 2014-07-28
The Visible Integral-field Replicable Unit Spectrograph (VIRUS) is a baseline array of 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET). VIRUS is the first optical astronomical instrument to be replicated on an industrial scale, and represents a relatively inexpensive solution for carrying out large-area spectroscopic surveys, such as the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic (VPH) grating with a 138 mm diameter clear aperture as its dispersing element. The instrument utilizes the grating in first-order for 350-550 nm. Including witness samples, a suite of 170 VPH gratings has been mass produced for VIRUS. Here, we present the design of the VIRUS VPH gratings and a discussion of their mass production. We additionally present the design and functionality of a custom apparatus that has been used to rapidly test the first-order diffraction efficiency of the gratings for various discrete wavelengths within the VIRUS spectral range. This device has been used to perform both in-situ tests to monitor the effects of adjustments to the production prescription as well as to carry out the final acceptance tests of the gratings' diffraction efficiency. Finally, we present the as-built performance results for the entire suite of VPH gratings.
[4]  oai:arXiv.org:1302.5720  [pdf] - 630672
DECal: A Spectrophotometric Calibration System For DECam
Comments: 10 pages, 5 figures. To appear in conference proceedings: "Calibration and Standardization of Large Surveys and Missions in Astronomy and Astrophysics" (Fermilab, April 16-19, 2012)
Submitted: 2013-02-22
DECal is a new calibration system for the CTIO 4 m Blanco telescope. It is currently being installed as part of the Dark Energy Survey and will provide both broadband flat fields and narrowband (about 1 nm bandwidth) spectrophotometric calibration for the new Dark Energy Camera (DECam). Both of these systems share a new Lambertian flat field screen. The broadband flat field system uses LEDs to illuminate each photometric filter. The spectrophotometric calibration system consists of a monochromator-based tunable light source that is projected onto the flat field screen using a custom line-to-spot fiber bundle and an engineered diffuser. Several calibrated photodiodes positioned along the beam monitor the telescope throughput as a function of wavelength. This system will measure the wavelength-dependent instrumental response function of the total telescope+instrument system in the range 300 < lambda < 1100nm. The spectrophotometric calibration will be performed regularly (roughly once per month) to determine the spectral response of the DECam system and to monitor changes in instrumental throughput during the five year Dark Energy Survey project.
[5]  oai:arXiv.org:1302.5738  [pdf] - 630675
aTmcam: A Simple Atmospheric Transmission Monitoring Camera For Sub 1% Photometric Precision
Comments: 11 pages, 8 figures. To appear in conference proceeding: "Calibration and Standardization of Large Surveys and Missions in Astronomy and Astrophysics" (Fermilab, April 16-18, 2012)
Submitted: 2013-02-22
Traditional color and airmass corrections can typically achieve ~0.02 mag precision in photometric observing conditions. A major limiting factor is the variability in atmospheric throughput, which changes on timescales of less than a night. We present preliminary results for a system to monitor the throughput of the atmosphere, which should enable photometric precision when coupled to more traditional techniques of less than 1% in photometric conditions. The system, aTmCam, consists of a set of imagers each with a narrow-band filter that monitors the brightness of suitable standard stars. Each narrowband filter is selected to monitor a different wavelength region of the atmospheric transmission, including regions dominated by the precipitable water absorption and aerosol scattering. We have built a prototype system to test the notion that an atmospheric model derived from a few color indices measurements can be an accurate representation of the true atmospheric transmission. We have measured the atmospheric transmission with both narrowband photometric measurements and spec- troscopic measurements; we show that the narrowband imaging approach can predict the changes in the throughput of the atmosphere to better than ~10% across a broad wavelength range, so as to achieve photometric precision less than 0.01 mag.