sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Prober, Daniel E.

Normalized to: Prober, D.

4 article(s) in total. 9 co-authors, from 1 to 4 common article(s). Median position in authors list is 3,5.

[1]  oai:arXiv.org:1411.1118  [pdf] - 915510
Normal Metal Hot-Electron Nanobolometer with Johnson Noise Thermometry Readout
Comments: 5 pages, 5 figures, presented at the 25th International Symposium on Space Terahertz Technology (Moscow, Russia, 27-30 April 2014)
Submitted: 2014-11-04
The sensitivity of a THz hot-electron nanobolometer (nano-HEB) made from a normal metal is analyzed. Johnson Noise Thermometry (JNT) is employed as a readout technique. In contrast to its superconducting TES counterpart, the normal-metal nano-HEB can operate at any cryogenic temperature depending on the required radiation background limited Noise Equivalent Power (NEP). It does not require bias lines; 100s of nano-HEBs can be read by a single low-noise X-band amplifier via a filter bank channelizer. The modeling predicts that even with the sensitivity penalty due to the amplifier noise, an NEP ~ 10$^{-20}$ - 10$^{-19}$ W/Hz$^{1/2}$ can be expected at 50-100 mK in 10-20 nm thin titanium (Ti) normal metal HEBs with niobium (Nb) contacts. This NEP is fairly constant over a range of readout frequencies ~ 10 GHz. Although materials with weaker electron-phonon coupling (bismuth, graphene) do not improve the minimum achievable NEP, they can be considered if a larger than 10 GHz readout bandwidth is required.
[2]  oai:arXiv.org:1406.6384  [pdf] - 1215199
Monolayer graphene bolometer as a sensitive far-IR detector
Comments: 9 pages. 6 figure, SPIE Astronomical Telescopes + Instrumentation, Montr\'eal, Quebec, Canada, 22-27 June, 2014
Submitted: 2014-06-24
In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few {\mu}m$^2$ of monolayer graphene (MLG) flake which can be embedded into either a planar antenna or waveguide circuit via NbN (or NbTiN) superconducting contacts with critical temperature ~ 14 K. Recent data on the strength of the electron-phonon coupling are used in the present analysis and the contribution of the readout noise to the Noise Equivalent Power (NEP) is explicitly computed. The readout scheme utilizes Johnson Noise Thermometry (JNT) allowing for Frequency-Domain Multiplexing (FDM) using narrowband filter coupling of the HEBs. In general, the filter bandwidth and the summing amplifier noise have a significant effect on the overall system sensitivity. The analysis shows that the readout contribution can be reduced to that of the bolometer phonon noise if the detector device is operated at 0.05 K and the JNT signal is read at about 10 GHz where the Johnson noise emitted in equilibrium is substantially reduced. Beside the high sensitivity (NEP < 10$^{-20}$ W/Hz$^{1/2}$, this bolometer does not have any hard saturation limit and thus can be used for far-IR sky imaging with arbitrary contrast. By changing the operating temperature of the bolometer the sensitivity can be fine tuned to accommodate the background photon flux in a particular application. By using a broadband low-noise kinetic inductance parametric amplifier, ~100s of graphene HEBs can be read simultaneously without saturation of the system output.
[3]  oai:arXiv.org:1208.5803  [pdf] - 773383
Nanobolometers for THz Photon Detection
Comments: 16 pages, 12 figures, 128 references
Submitted: 2012-08-28
This article reviews the state of rapidly emerging terahertz hot-electron nanobolometers (nano-HEB), which are currently among of the most sensitive radiation power detectors at submillimeter wavelengths. With the achieved noise equivalent power close to 10^{-19} W/Hz^{1/2} and potentially capable of approaching NEP ~ 10^{-20} W/Hz^{1/2}, nano-HEBs are very important for future space astrophysics platforms with ultralow submillimeter radiation background. The ability of these sensors to detect single low-energy photons opens interesting possibilities for quantum calorimetry in the mid-infrared and even in the farinfrared parts of the electromagnetic spectrum. We discuss the competition in the field of ultrasensitive detectors, the physics and technology of nano-HEBs, recent experimental results, and perspectives for future development.
[4]  oai:arXiv.org:1207.2164  [pdf] - 773381
Energy-resolved detection of single infrared photons with {\lambda} = 8 {\mu}m using a superconducting microbolometer
Comments: 17 pages, 5 figures. Accepted to Applied Physics Letters
Submitted: 2012-07-09, last modified: 2012-07-20
We report on the detection of single photons with {\lambda} = 8 {\mu}m using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 {\mu}m^3 fabricated on a silicon substrate. Poisson photon counting statistics including simultaneous detection of 3 photons was observed. The width of the photon-number peaks was 0.11 eV, 70% of the photon energy, at 50-100 mK. This achieved energy resolution is one of the best figures reported so far for superconducting devices. Such devices can be suitable for single photon calorimetric spectroscopy throughout the mid-infrared and even the far-infrared.