sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Prieto, E.

Normalized to: Prieto, E.

13 article(s) in total. 516 co-authors, from 1 to 5 common article(s). Median position in authors list is 8,0.

[1]  oai:arXiv.org:1807.04158  [pdf] - 1714414
3D metrology with a laser tracker inside a vacuum chamber for NISP test campaign
Comments:
Submitted: 2018-07-11
In the frame of the test of NISP instrument for ESA Euclid mission, the question was raised to perform a metrology measurement of different components during the thermal vacuum test of NISP instrument. NISP will be tested at Laboratoire d'Astrophysique de Marseille (LAM) in ERIOS chamber under vacuum and thermal conditions in order to qualify the instrument in its operating environment and to perform the final acceptance test before delivery to the payload. One of the main objectives of the test campaign will be the measurement of the focus position of NISP image plane with respect to the EUCLID object plane. To simulate the EUCLID object plane, a telescope simulator with a very well know focal distance will be installed in front of NISP into ERIOS chamber. We need to measure at cold and vacuum the position of reflectors installed on NISP instrument and the telescope simulator. From these measurements, we will provide at operational temperature the measurement of references frames set on the telescope simulator and NISP, the knowledge of the coordinates of the object point source provided by the telescope simulator and the measurement of the angle between the telescope simulator optical axis and NISP optical axis. In this context, we have developed a metrology method based on the use of a laser tracker to measure the position of the reflectors inside ERIOS. The laser tracker is installed outside the vacuum chamber and measure through a curved window reflectors put inside the chamber either at ambient pressure or vacuum pressure. Several tests campaigns have been done at LAM to demonstrate the measurement performance with this configuration. Using a well know reflectors configuration, we show that it is possible to correct the laser tracker measurement from the window disturbances and from the vacuum impact. A corrective term is applied to the data and allows retrieving the real coordinates of the reflectors with a bias lower than 30$\mu$m, which is lower than the laser tracker measurement uncertainties estimated at 60$\mu$m. No additional error term of the laser tracker measurement is observed when using the laser tracker with the curved window and in vacuum, comparing with a classical use of the laser tracker. With these test campaign, we have been able to demonstrate the possibility to use a laser tracker to measure in real time during a vacuum thermal test the position of different mechanical parts into a vacuum chamber with an accuracy better than 60$\mu$m.
[2]  oai:arXiv.org:1210.2728  [pdf] - 574586
A spectrograph instrument concept for the Prime Focus Spectrograph (PFS) on Subaru Telescope
Comments: 8 pages, 5 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy IV, Ian S. McLean, Suzanne K. Ramsay, Hideki Takami, Editors, Proc. SPIE 8446 (2012)"
Submitted: 2012-10-09
We describe the conceptual design of the spectrograph opto-mechanical concept for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the SUBARU telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering in total, a wavelength range from 380 nm to 1300 nm. The requirements for the instrument are summarized in Section 1. We present the optical design and the optical performance and analysis in Section 2. Section 3 introduces the mechanical design, its requirements and the proposed concepts. Finally, the AIT phases for the Spectrograph System are described in Section 5.
[3]  oai:arXiv.org:1210.2719  [pdf] - 574579
Prime Focus Spectrograph - Subaru's future -
Comments: 13 pages, 11 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy IV, Ian S. McLean, Suzanne K. Ramsay, Hideki Takami, Editors, Proc. SPIE 8446 (2012)"
Submitted: 2012-10-09
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 {\mu}m to 1.3 {\mu}m will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.
[4]  oai:arXiv.org:1210.2740  [pdf] - 1151992
Detectors and cryostat design for the SuMIRe Prime Focus Spectrograph (PFS)
Comments:
Submitted: 2012-10-09
We describe the conceptual design of the camera cryostats, detectors, and detector readout electronics for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the Subaru telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering wavelength ranges 3800 {\AA} - 6700 {\AA}, 6500 {\AA} - 10000 {\AA}, and 9700 {\AA} - 13000 {\AA}, with the dispersed light being imaged in each channel by a f/1.10 vacuum Schmidt camera. In the blue and red channels a pair of Hamamatsu 2K x 4K edge-buttable CCDs with 15 um pixels are used to form a 4K x 4K array. For the IR channel, the new Teledyne 4K x 4K, 15 um pixel, mercury-cadmium-telluride sensor with substrate removed for short-wavelength response and a 1.7 um cutoff will be used. Identical detector geometry and a nearly identical optical design allow for a common cryostat design with the only notable difference being the need for a cold radiation shield in the IR camera to mitigate thermal background. This paper describes the details of the cryostat design and cooling scheme, relevant thermal considerations and analysis, and discusses the detectors and detector readout electronics.
[5]  oai:arXiv.org:1110.3193  [pdf] - 429544
Euclid Definition Study Report
Laureijs, R.; Amiaux, J.; Arduini, S.; Auguères, J. -L.; Brinchmann, J.; Cole, R.; Cropper, M.; Dabin, C.; Duvet, L.; Ealet, A.; Garilli, B.; Gondoin, P.; Guzzo, L.; Hoar, J.; Hoekstra, H.; Holmes, R.; Kitching, T.; Maciaszek, T.; Mellier, Y.; Pasian, F.; Percival, W.; Rhodes, J.; Criado, G. Saavedra; Sauvage, M.; Scaramella, R.; Valenziano, L.; Warren, S.; Bender, R.; Castander, F.; Cimatti, A.; Fèvre, O. Le; Kurki-Suonio, H.; Levi, M.; Lilje, P.; Meylan, G.; Nichol, R.; Pedersen, K.; Popa, V.; Lopez, R. Rebolo; Rix, H. -W.; Rottgering, H.; Zeilinger, W.; Grupp, F.; Hudelot, P.; Massey, R.; Meneghetti, M.; Miller, L.; Paltani, S.; Paulin-Henriksson, S.; Pires, S.; Saxton, C.; Schrabback, T.; Seidel, G.; Walsh, J.; Aghanim, N.; Amendola, L.; Bartlett, J.; Baccigalupi, C.; Beaulieu, J. -P.; Benabed, K.; Cuby, J. -G.; Elbaz, D.; Fosalba, P.; Gavazzi, G.; Helmi, A.; Hook, I.; Irwin, M.; Kneib, J. -P.; Kunz, M.; Mannucci, F.; Moscardini, L.; Tao, C.; Teyssier, R.; Weller, J.; Zamorani, G.; Osorio, M. R. Zapatero; Boulade, O.; Foumond, J. J.; Di Giorgio, A.; Guttridge, P.; James, A.; Kemp, M.; Martignac, J.; Spencer, A.; Walton, D.; Blümchen, T.; Bonoli, C.; Bortoletto, F.; Cerna, C.; Corcione, L.; Fabron, C.; Jahnke, K.; Ligori, S.; Madrid, F.; Martin, L.; Morgante, G.; Pamplona, T.; Prieto, E.; Riva, M.; Toledo, R.; Trifoglio, M.; Zerbi, F.; Abdalla, F.; Douspis, M.; Grenet, C.; Borgani, S.; Bouwens, R.; Courbin, F.; Delouis, J. -M.; Dubath, P.; Fontana, A.; Frailis, M.; Grazian, A.; Koppenhöfer, J.; Mansutti, O.; Melchior, M.; Mignoli, M.; Mohr, J.; Neissner, C.; Noddle, K.; Poncet, M.; Scodeggio, M.; Serrano, S.; Shane, N.; Starck, J. -L.; Surace, C.; Taylor, A.; Verdoes-Kleijn, G.; Vuerli, C.; Williams, O. R.; Zacchei, A.; Altieri, B.; Sanz, I. Escudero; Kohley, R.; Oosterbroek, T.; Astier, P.; Bacon, D.; Bardelli, S.; Baugh, C.; Bellagamba, F.; Benoist, C.; Bianchi, D.; Biviano, A.; Branchini, E.; Carbone, C.; Cardone, V.; Clements, D.; Colombi, S.; Conselice, C.; Cresci, G.; Deacon, N.; Dunlop, J.; Fedeli, C.; Fontanot, F.; Franzetti, P.; Giocoli, C.; Garcia-Bellido, J.; Gow, J.; Heavens, A.; Hewett, P.; Heymans, C.; Holland, A.; Huang, Z.; Ilbert, O.; Joachimi, B.; Jennins, E.; Kerins, E.; Kiessling, A.; Kirk, D.; Kotak, R.; Krause, O.; Lahav, O.; van Leeuwen, F.; Lesgourgues, J.; Lombardi, M.; Magliocchetti, M.; Maguire, K.; Majerotto, E.; Maoli, R.; Marulli, F.; Maurogordato, S.; McCracken, H.; McLure, R.; Melchiorri, A.; Merson, A.; Moresco, M.; Nonino, M.; Norberg, P.; Peacock, J.; Pello, R.; Penny, M.; Pettorino, V.; Di Porto, C.; Pozzetti, L.; Quercellini, C.; Radovich, M.; Rassat, A.; Roche, N.; Ronayette, S.; Rossetti, E.; Sartoris, B.; Schneider, P.; Semboloni, E.; Serjeant, S.; Simpson, F.; Skordis, C.; Smadja, G.; Smartt, S.; Spano, P.; Spiro, S.; Sullivan, M.; Tilquin, A.; Trotta, R.; Verde, L.; Wang, Y.; Williger, G.; Zhao, G.; Zoubian, J.; Zucca, E.
Comments: 116 pages, with executive summary and table of contents
Submitted: 2011-10-14
Euclid is a space-based survey mission from the European Space Agency designed to understand the origin of the Universe's accelerating expansion. It will use cosmological probes to investigate the nature of dark energy, dark matter and gravity by tracking their observational signatures on the geometry of the universe and on the cosmic history of structure formation. The mission is optimised for two independent primary cosmological probes: Weak gravitational Lensing (WL) and Baryonic Acoustic Oscillations (BAO). The Euclid payload consists of a 1.2 m Korsch telescope designed to provide a large field of view. It carries two instruments with a common field-of-view of ~0.54 deg2: the visual imager (VIS) and the near infrared instrument (NISP) which contains a slitless spectrometer and a three bands photometer. The Euclid wide survey will cover 15,000 deg2 of the extragalactic sky and is complemented by two 20 deg2 deep fields. For WL, Euclid measures the shapes of 30-40 resolved galaxies per arcmin2 in one broad visible R+I+Z band (550-920 nm). The photometric redshifts for these galaxies reach a precision of dz/(1+z) < 0.05. They are derived from three additional Euclid NIR bands (Y, J, H in the range 0.92-2.0 micron), complemented by ground based photometry in visible bands derived from public data or through engaged collaborations. The BAO are determined from a spectroscopic survey with a redshift accuracy dz/(1+z) =0.001. The slitless spectrometer, with spectral resolution ~250, predominantly detects Ha emission line galaxies. Euclid is a Medium Class mission of the ESA Cosmic Vision 2015-2025 programme, with a foreseen launch date in 2019. This report (also known as the Euclid Red Book) describes the outcome of the Phase A study.
[6]  oai:arXiv.org:1106.1706  [pdf] - 371192
The BigBOSS Experiment
Schlegel, D.; Abdalla, F.; Abraham, T.; Ahn, C.; Prieto, C. Allende; Annis, J.; Aubourg, E.; Azzaro, M.; Baltay, S. Bailey. C.; Baugh, C.; Bebek, C.; Becerril, S.; Blanton, M.; Bolton, A.; Bromley, B.; Cahn, R.; Carton, P. -H.; Cervantes-Cota, J. L.; Chu, Y.; Cortes, M.; Dawson, K.; Dey, A.; Dickinson, M.; Diehl, H. T.; Doel, P.; Ealet, A.; Edelstein, J.; Eppelle, D.; Escoffier, S.; Evrard, A.; Faccioli, L.; Frenk, C.; Geha, M.; Gerdes, D.; Gondolo, P.; Gonzalez-Arroyo, A.; Grossan, B.; Heckman, T.; Heetderks, H.; Ho, S.; Honscheid, K.; Huterer, D.; Ilbert, O.; Ivans, I.; Jelinsky, P.; Jing, Y.; Joyce, D.; Kennedy, R.; Kent, S.; Kieda, D.; Kim, A.; Kim, C.; Kneib, J. -P.; Kong, X.; Kosowsky, A.; Krishnan, K.; Lahav, O.; Lampton, M.; LeBohec, S.; Brun, V. Le; Levi, M.; Li, C.; Liang, M.; Lim, H.; Lin, W.; Linder, E.; Lorenzon, W.; de la Macorra, A.; Magneville, Ch.; Malina, R.; Marinoni, C.; Martinez, V.; Majewski, S.; Matheson, T.; McCloskey, R.; McDonald, P.; McKay, T.; McMahon, J.; Menard, B.; Miralda-Escude, J.; Modjaz, M.; Montero-Dorta, A.; Morales, I.; Mostek, N.; Newman, J.; Nichol, R.; Nugent, P.; Olsen, K.; Padmanabhan, N.; Palanque-Delabrouille, N.; Park, I.; Peacock, J.; Percival, W.; Perlmutter, S.; Peroux, C.; Petitjean, P.; Prada, F.; Prieto, E.; Prochaska, J.; Reil, K.; Rockosi, C.; Roe, N.; Rollinde, E.; Roodman, A.; Ross, N.; Rudnick, G.; Ruhlmann-Kleider, V.; Sanchez, J.; Sawyer, D.; Schimd, C.; Schubnell, M.; Scoccimaro, R.; Seljak, U.; Seo, H.; Sheldon, E.; Sholl, M.; Shulte-Ladbeck, R.; Slosar, A.; Smith, D. S.; Smoot, G.; Springer, W.; Stril, A.; Szalay, A. S.; Tao, C.; Tarle, G.; Taylor, E.; Tilquin, A.; Tinker, J.; Valdes, F.; Wang, J.; Wang, T.; Weaver, B. A.; Weinberg, D.; White, M.; Wood-Vasey, M.; Yang, J.; Yeche, X. Yang. Ch.; Zakamska, N.; Zentner, A.; Zhai, C.; Zhang, P.
Comments: This report is based on the BigBOSS proposal submission to NOAO in October 2010, and reflects the project status at that time with minor updates
Submitted: 2011-06-09
BigBOSS is a Stage IV ground-based dark energy experiment to study baryon acoustic oscillations (BAO) and the growth of structure with a wide-area galaxy and quasar redshift survey over 14,000 square degrees. It has been conditionally accepted by NOAO in response to a call for major new instrumentation and a high-impact science program for the 4-m Mayall telescope at Kitt Peak. The BigBOSS instrument is a robotically-actuated, fiber-fed spectrograph capable of taking 5000 simultaneous spectra over a wavelength range from 340 nm to 1060 nm, with a resolution R = 3000-4800. Using data from imaging surveys that are already underway, spectroscopic targets are selected that trace the underlying dark matter distribution. In particular, targets include luminous red galaxies (LRGs) up to z = 1.0, extending the BOSS LRG survey in both redshift and survey area. To probe the universe out to even higher redshift, BigBOSS will target bright [OII] emission line galaxies (ELGs) up to z = 1.7. In total, 20 million galaxy redshifts are obtained to measure the BAO feature, trace the matter power spectrum at smaller scales, and detect redshift space distortions. BigBOSS will provide additional constraints on early dark energy and on the curvature of the universe by measuring the Ly-alpha forest in the spectra of over 600,000 2.2 < z < 3.5 quasars. BigBOSS galaxy BAO measurements combined with an analysis of the broadband power, including the Ly-alpha forest in BigBOSS quasar spectra, achieves a FOM of 395 with Planck plus Stage III priors. This FOM is based on conservative assumptions for the analysis of broad band power (kmax = 0.15), and could grow to over 600 if current work allows us to push the analysis to higher wave numbers (kmax = 0.3). BigBOSS will also place constraints on theories of modified gravity and inflation, and will measure the sum of neutrino masses to 0.024 eV accuracy.
[7]  oai:arXiv.org:0811.3442  [pdf] - 1001101
Image Slicer Performances from a Demonstrator for the SNAP/JDEM Mission - Part I: Wavelength Accuracy
Comments: Submitted to PASP
Submitted: 2008-11-20
A well-adapted visible and infrared spectrograph has been developed for the SNAP (SuperNova/Acceleration Probe) experiment proposed for JDEM. The instrument should have a high sensitivity to see faint supernovae but also a good redshift determination better than 0.003(1+z) and a precise spectrophotometry (2%). An instrument based on an integral field method with the powerful concept of imager slicing has been designed. A large prototyping effort has been performed in France which validates the concept. In particular a demonstrator reproducing the full optical configuration has been built and tested to prove the optical performances both in the visible and in the near infrared range. This paper is the first of two papers. The present paper focus on the wavelength measurement while the second one will present the spectrophotometric performances. We adress here the spectral accuracy expected both in the visible and in the near infrared range in such configuration and we demonstrate, in particular, that the image slicer enhances the instrumental performances in the spectral measurement precision by removing the slit effect. This work is supported in France by CNRS/INSU/IN2P3 and by the French spatial agency (CNES) and in US by the University of California.
[8]  oai:arXiv.org:physics/0512002  [pdf] - 1456483
An original image slicer designed for Integral Field Spectroscopy with NIRSpec/JSWT
Comments: Submitted to Optical Engineering
Submitted: 2005-12-01
Integral Field Spectroscopy (IFS) provides a spectrum simultaneously for each spatial sample of an extended, two-dimensional field. It consists of an Integral Field Unit (IFU) which slices and re-arranges the initial field along the entrance slit of a spectrograph. This article presents an original design of IFU based on the advanced image slicer concept. To reduce optical aberrations, pupil and slit mirrors are disposed in a fan-shaped configuration that means that angles between incident and reflected beams on each elements are minimized. The fan-shaped image slicer improves image quality in terms of wavefront error by a factor 2 comparing with classical image slicer and, furthermore it guaranties a negligible level of differential aberration in the field. As an exemple, we are presenting the design LAM used for its proposal at the NIRSPEC/IFU invitation of tender.
[9]  oai:arXiv.org:physics/0510174  [pdf] - 1456482
Modeling a Slicer Mirror Using Zemax User-Defined Surface
Comments: Submitted to the proceedings of the Durham Integral Field Spectroscopy Workshop July 4th-8th 2005
Submitted: 2005-10-19
A slicer mirror is a complex surface composed by many tilted and decentered mirrors sub-surfaces. The major difficulty to model such a complex surface is the large number of parameters used to define it. The Zemax's multi-configuration mode is usually used to specify each parameters (tilts, curvatures, decenters) for each mirror sub-surface which are then considered independently. Otherwise making use of the User-Defined Surface (UDS-DLL) Zemax capability, we are able to consider the set of sub-surfaces as a whole surface. In this paper, we present such a UDS-DLL tool comparing its performance with those of the classical multi-configuration mode. In particular, we explore the use of UDS-DLL to investigate the cross-talk due to the diffraction on the slicer array mirrors which has been a burden task when using multi-configuration mode.
[10]  oai:arXiv.org:astro-ph/0509684  [pdf] - 1468875
Optical replication techniques for image slicers
Comments: To be published in the proceedings of the Durham Integral Field Spectroscopy workshop 2005 July 04-08. REPLACEMENT (Sep 29): Author list updated
Submitted: 2005-09-22, last modified: 2005-09-29
The Smart Focal Planes (SmartFP) activity is a European Joint Research Activity funded to develop novel optical technologies for future large telescope instrumentation. In this paper, we will discuss the image slicer developments being carried out as part of this initiative. Image slicing technique s have many applications in the plans for instrumentation on Extremely Large Telescopes and will be central to the delivery of the science case. A study of a virtual "multi-object multi-ifu spectrograph and imager" (MOMSI) for a hypothetical OWL-class telescope reveals the need for focal plane splitting, deployable imagers and very small beam steering elements like deployable IFUs. The image slicer workpackage, lead from Durham University in collaboration with LFM Bremen, TNO Delft, UKATC Edinburgh, CRAL Lyon, LAM Marseille, Padua University and REFLEX Prague, is evaluating technologies for manufacturing micro optics in large numbers to enable multi-object integral field spectroscopy.
[11]  oai:arXiv.org:astro-ph/0405232  [pdf] - 64752
Supernova / Acceleration Probe: A Satellite Experiment to Study the Nature of the Dark Energy
Comments: 40 pages, 18 figures, submitted to PASP, http://snap.lbl.gov
Submitted: 2004-05-12
The Supernova / Acceleration Probe (SNAP) is a proposed space-based experiment designed to study the dark energy and alternative explanations of the acceleration of the Universe's expansion by performing a series of complementary systematics-controlled measurements. We describe a self-consistent reference mission design for building a Type Ia supernova Hubble diagram and for performing a wide-area weak gravitational lensing study. A 2-m wide-field telescope feeds a focal plane consisting of a 0.7 square-degree imager tiled with equal areas of optical CCDs and near infrared sensors, and a high-efficiency low-resolution integral field spectrograph. The SNAP mission will obtain high-signal-to-noise calibrated light-curves and spectra for several thousand supernovae at redshifts between z=0.1 and 1.7. A wide-field survey covering one thousand square degrees resolves ~100 galaxies per square arcminute. If we assume we live in a cosmological-constant-dominated Universe, the matter density, dark energy density, and flatness of space can all be measured with SNAP supernova and weak-lensing measurements to a systematics-limited accuracy of 1%. For a flat universe, the density-to-pressure ratio of dark energy can be similarly measured to 5% for the present value w0 and ~0.1 for the time variation w'. The large survey area, depth, spatial resolution, time-sampling, and nine-band optical to NIR photometry will support additional independent and/or complementary dark-energy measurement approaches as well as a broad range of auxiliary science programs. (Abridged)
[12]  oai:arXiv.org:astro-ph/0210087  [pdf] - 1938839
An Integral Field Spectrograph for SNAP Supernova Identification
Comments: This paper will be published in SPIE Proceedings Vol. 4850 and is made available as an electronic preprint with permission of SPIE. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited
Submitted: 2002-10-03
A well-adapted spectrograph concept has been developed for the SNAP (SuperNova/Acceleration Probe) experiment. The goal is to ensure proper identification of Type Ia supernovae and to standardize the magnitude of each candidate by determining explosion parameters. An instrument based on an integral field method with the powerful concept of imager slicing has been designed and is presented in this paper. The spectrograph concept is optimized to have very high efficiency and low spectral resolution (R~100), constant through the wavelength range (0.35-1.7 microns), adapted to the scientific goals of the mission.
[13]  oai:arXiv.org:astro-ph/0109060  [pdf] - 1232737
MIFS: A Mega Integral Field Spectrograph for the VLT
Comments: 10 pages, 2 figures June 2001 ESO workshop on "Scientific Drivers for ESO Future VLT/VLTI Instrumentation"
Submitted: 2001-09-05
We describe MIFS, a second generation integral-field spectrograph for the VLT, operating in the visible wavelength range. It combines a 1'x1' field of view with the improved spatial resolution provided by multi-conjugate adaptive optics and covers a large simultaneous spectral range (0.6-1.0 microns). A separate mode exploits the highest spatial resolution provided by adaptive optics. With this unique combination of capabilities, MIFS has a wide domain of application and a large discovery potential. The MIFS low-spatial resolution mode (sampled at 0.2") combined with the initial MCAO capabilities planned for the VLT will provide ultra-deep fields with a limiting magnitude for spectroscopy of R~28. MIFS will improve the present day detection limit of Lyman alpha emitters by a factor of 100, and will detect low-mass star-forming galaxies to z~7. The MIFS high-spatial resolution mode (3"x3" field sampled at 0.01") is optimized for the next step in (MC)AO. It will probe, e.g., the relationship between supermassive central black holes and their host galaxy and the physics of winds from accretion disks in young stellar objects at unprecedented spatial resolution. MIFS will extend Europe's lead in integral-field spectroscopy. It capitalizes on new developments in adaptive optics, and is a key step towards instrumentation for OWL.