sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Prieskorn, Z.

Normalized to: Prieskorn, Z.

9 article(s) in total. 15 co-authors, from 1 to 5 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1602.07709  [pdf] - 1364430
The Speedster-EXD- A New Event-Driven Hybrid CMOS X-ray Detector
Comments: 24 pages, 14 figures. Accepted for publication in the Journal of Astronomical Telescopes, Instruments, and Systems
Submitted: 2016-02-24
The Speedster-EXD is a new 64x64 pixel, 40 $\mu$m pixel pitch, 100 $\mu$m depletion depth hybrid CMOS X-ray detector (HCD) with the capability of reading out only those pixels containing event charge, thus enabling fast effective frame rates. A global charge threshold can be specified, and pixels containing charge above this threshold are flagged and read out. The Speedster detector has also been designed with other advanced in-pixel features to improve performance, including a low-noise, high-gain CTIA amplifier that eliminates interpixel capacitance crosstalk (IPC), and in-pixel Correlated Double Sampling (CDS) subtraction to reduce reset noise. We measure the best energy resolution on the Speedster-EXD detector to be 206 eV (3.5 %) at 5.89 keV and 172 eV (10.0 %) at 1.49 keV. The average IPC to the four adjacent pixels is measured to be 0.25 $\pm$ 0.2 % (i.e. consistent with zero). The pixel-to-pixel gain variation is measured to be 0.80 $\pm$ 0.03 %, and a Monte Carlo simulation is applied to better characterize the contributions to the energy resolution.
[2]  oai:arXiv.org:1411.4655  [pdf] - 1223222
The speedster-EXD - A new event-triggered hybrid CMOS x-ray detector
Comments: contribution to proceedings of SPIE Astronomical Telescopes & Instrumentation 2014
Submitted: 2014-11-17
We present preliminary characterization of the Speedster-EXD, a new event driven hybrid CMOS detector (HCD) developed in collaboration with Penn State University and Teledyne Imaging Systems. HCDs have advantages over CCDs including lower susceptibility to radiation damage, lower power consumption, and faster read-out time to avoid pile-up. They are deeply depleted and able to detect x-rays down to approximately 0.1 keV. The Speedster-EXD has additional in-pixel features compared to previously published HCDs including: (1) an in-pixel comparator that enables read out of only the pixels with signal from an x-ray event, (2) four different gain modes to optimize either full well capacity or energy resolution, (3) in-pixel CDS subtraction to reduce read noise, and (4) a low-noise, high-gain CTIA amplifier to eliminate interpixel capacitance crosstalk. When using the comparator feature, the user can set a comparator threshold and only pixels above the threshold will be read out. This feature can be run in two modes including single pixel readout in which only pixels above the threshold are read out and 3x3 readout where a 3x3 region centered on the central pixel of the x-ray event is read out. The comparator feature of the Speedster-EXD increases the detector array effective frame rate by orders of magnitude. The new features of the Speedster-EXD hybrid CMOS x-ray detector are particularly relevant to future high throughput x-ray missions requiring large-format silicon imagers.
[3]  oai:arXiv.org:1406.4393  [pdf] - 837239
Photoelectron track length distributions measured in a negative ion time projection chamber
Comments: 8 pages, 7 figures, 5 tables. Published in IEEE Transactions on Nuclear Science
Submitted: 2014-06-17
We report photoelectron track length distributions between 3 and 8 keV in gas mixtures of Ne+CO2+CH3NO2 (260:80:10 Torr) and CO2+CH3NO2 (197.5: 15 Torr). The measurements were made using a negative ion time projection chamber (NITPC) at the National Synchrotron Light Source (NSLS) at the Brookhaven National Laboratory (BNL). We report the first quantitative analysis of photoelectron track length distributions in a gas. The distribution of track lengths at a given energy is best fit by a lognormal distribution. A powerlaw distribution of the form, f(E)=a(E/Eo)n, is found to fit the relationship between mean track length and energy. We find n=1.29 +/- 0.07 for Ne+CO2+CH3NO2 and n=1.20 +/- 0.09 for CO2+CH3NO2. Understanding the distribution of photoelectron track lengths in proportional counter gases is important for optimizing the pixel size and the dimensions of the active region in electron-drift time projection chambers (TPCs) and NITPC X-ray polarimeters.
[4]  oai:arXiv.org:1107.3079  [pdf] - 702217
Gas Gain Measurements from a Negative Ion TPC X-ray Polarimeter
Comments: 6 pages, 6 figures, accepted for publication in IEEE Trans Nucl Sci
Submitted: 2011-07-15, last modified: 2013-08-05
Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray emission of a Gamma-ray burst (GRB), a large area detector is needed. Diffusion of the electron cloud in a standard TPC could be prohibitive to measuring good modulation when the drift distance is large. Therefore, we propose using a negative ion TPC (NITPC) with Nitromethane (CH3NO2) as the electron capture agent. The diffusion of negative ions is reduced over that of electrons due to the thermal coupling of the negative ions to the surrounding gas. This allows for larger area detectors as the drift distance can be increased without degrading polarimeter modulation. Negative ions also travel ~200 times slower than electrons, allowing the readout electronics to operate slower, resulting in a reduction of instrument power. To optimize the NITPC design, we have measured gas gain with SciEnergy gas electron multipliers (GEMs) in single and double GEM configurations. Each setup was tested with different gas combinations, concentrations and pressures: P10 700 Torr, Ne+CO2 700 Torr at varying concentrations of CO2 and Ne+CO2+CH3NO2 700 Torr. We report gain as a function of total voltage, measured from top to bottom of the GEM stack, and as a function of drift field strength for the gas concentrations listed above. Examples of photoelectron tracks at 5.9 keV are also presented.
[5]  oai:arXiv.org:1303.6666  [pdf] - 1165560
Characterization of Si Hybrid CMOS Detectors for use in the Soft X-ray Band
Comments: 19 pages, 12 figures, 4 tables, accepted for publication in Nuclear Inst. and Methods in Physics Research, A
Submitted: 2013-03-26
We report on the characterization of four Teledyne Imaging Systems HAWAII Hybrid Si CMOS detectors designed for X-ray detection. Three H1RG detectors were studied along with a specially configured H2RG. Read noise measurements were performed, with the lowest result being 7.1 e- RMS. Interpixel capacitive crosstalk (IPC) was measured for the three H1RGs and for the H2RG. The H1RGs had IPC upper limits of 4.0 - 5.5 % (up & down pixels) and 8.7 - 9.7 % (left & right pixels), indicating a clear asymmetry. Energy resolution is reported for two X-ray lines, 1.5 & 5.9 keV, at multiple temperatures between 150 - 210 K. The best resolution measured at 5.9 keV was 250 eV (4.2 %) at 150 K, with IPC contributing significantly to this measured energy distribution. The H2RG, with a unique configuration designed to decrease the capacitive coupling between ROIC pixels, had an IPC of 1.8 +/- 1.0 % indicating a dramatic improvement in IPC with no measurable asymmetry. We also measured dark current as a function of temperature for each detector. For the detector with the lowest dark current, at 150 K, we measured a dark current of 0.020 +/- 0.001 (e- sec-1 pix-1). There is also a consistent break in the fit to the dark current data for each detector. Above 180 K, all the data can be fit by the product of a power law in temperature and an exponential. Below 180 K the dark current decreases more slowly; a shallow power law or constant must be added to each fit, indicating a different form of dark current is dominant in this temperature regime. Dark current figures of merit at 293 K are estimated from the fit for each detector.
[6]  oai:arXiv.org:1207.6317  [pdf] - 1125125
Characterization of an x-ray hybrid CMOS detector with low interpixel capacitive crosstalk
Comments: contribution to proceedings of SPIE Astronomical Telescopes & Instrumentation 2012
Submitted: 2012-07-26
We present the results of x-ray measurements on a hybrid CMOS detector that uses a H2RG ROIC and a unique bonding structure. The silicon absorber array has a 36{\mu}m pixel size, and the readout array has a pitch of 18{\mu}m; but only one readout circuit line is bonded to each 36x36{\mu}m absorber pixel. This unique bonding structure gives the readout an effective pitch of 36{\mu}m. We find the increased pitch between readout bonds significantly reduces the interpixel capacitance of the CMOS detector reported by Bongiorno et al. 2010 and Kenter et al. 2005.
[7]  oai:arXiv.org:1207.6058  [pdf] - 1125092
Recent Progress on Developments and Characterization of Hybrid CMOS X-ray Detectors
Comments: contribution to proceedings of SPIE Astronomical Telescopes & Instrumentation 2012
Submitted: 2012-07-25
Future space-based X-ray telescope missions are likely to have significantly increased demands on detector read out rates due to increased collection area, and there will be a desire to minimize radiation damage in the interests of maintaining spectral resolution. While CCDs have met the requirements of past missions, active pixel sensors are likely to be a standard choice for some future missions due to their inherent radiation hardness and fast, flexible read-out architecture. One form of active pixel sensor is the hybrid CMOS sensor. In a joint program of Penn State University and Teledyne Imaging Sensors, hybrid CMOS sensors have been developed for use as X-ray detectors. Results of this development effort and tests of fabricated detectors will be presented, along with potential applications for future missions.
[8]  oai:arXiv.org:1207.0045  [pdf] - 531964
Burst Fluence Distributions of Soft Gamma Repeaters 1806-20 and 1900+14 in the RXTE PCA era
Comments: 6 pages, 5 figures and 1 table - Accepted by ApJ
Submitted: 2012-06-30
We study the fluence distributions of over 3040 bursts from SGR 1806-20 and over 1963 bursts from SGR 1900+14 using the complete set of observations available from the Rossi X-Ray Timing Explorer/Proportional Counter Array through March 2011. Cumulative event distributions are presented for both sources and are fitted with single and broken power laws as well as an exponential cutoff. The distributions are best fit by a broken power law with exponential cutoff, however the statistical significance of the cutoff is not high and the upper portion of the broken power law can be explained as the expected number of false bursts due to random noise fluctuations. Event distributions are also examined in high and low burst rate regimes and power law indices are found to be consistent, independent of the burst rate. The contribution function of the event fluence is calculated. This distribution shows that the energy released in the SGR bursts is dominated by the most powerful events for both sources. The power law nature of these distributions combined with the dominant energy dissipation of the system occurring in the large, less frequent bursts is indicative of a self-organized critical system (SOC), as suggested by Go\u{g}us, et al. in 1999.
[9]  oai:arXiv.org:astro-ph/0611716  [pdf] - 87102
Evidence for 1122 Hz X-Ray Burst Oscillations from the Neutron-Star X-Ray Transient XTE J1739-285
Comments: To appear in ApJL, 4 pages
Submitted: 2006-11-22, last modified: 2007-01-30
We report on millisecond variability from the X-ray transient XTE J1739-285. We detected six X-ray type I bursts and found evidence for oscillations at 1122 +/- 0.3 Hz in the brightest X-ray burst. Taking into consideration the power in the oscillations and the number of trials in the search, the detection is significant at the 99.96% confidence level. If the oscillations are confirmed, the oscillation frequency would suggest that XTE J1739-285 contains the fastest rotating neutron star yet found. We also found millisecond quasiperiodic oscillations in the persistent emission with frequencies ranging from 757 Hz to 862 Hz. Using the brightest burst, we derive an upper limit on the source distance of about 10.6 kpc.