Normalized to: Precup, N.
[1]
oai:arXiv.org:2002.05219 [pdf] - 2065429
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Zhang, C.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.
Submitted: 2020-02-12
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial
gravitational waves in the Cosmic Microwave Background polarization, which
would be direct evidence of the inflation theory. While the tensor-to-scalar
ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further
improvements on this upper limit are hindered by polarized Galactic foreground
emissions and removal of gravitational lensing polarization. The 30/40 GHz
receiver of the BICEP Array (BA) will deploy at the end of 2019 and will
constrain the synchrotron foreground with unprecedented accuracy within the BK
sky patch. We will show the design of the 30/40 GHz detectors and test results
summarizing its performance. The low optical and atmospheric loading at these
frequencies requires our TES detectors to have low saturation power in order to
be photon-noise dominated. To realize the low thermal conductivity required
from a 250 mK base temperature, we developed new bolometer leg designs. We will
present the relevant measured detector parameters: G, Tc, Rn, Psat , and
spectral bands, and noise spectra. We achieved a per bolometer NEP including
all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon
noise level 1.54E-17 W/sqrt(Hz).
[2]
oai:arXiv.org:2002.05228 [pdf] - 2048104
Design and performance of the first BICEP Array receiver
Schillaci, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Branches of cosmic inflationary models, such as slow-roll inflation, predict
a background of primordial gravitational waves that imprints a unique
odd-parity B-mode pattern in the Cosmic Microwave Background (CMB) at
amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment
targets this primordial signature, the amplitude of which is parameterized by
the tensor-to-scalar ratio r, by observing the polarized microwave sky through
the exceptionally clean and stable atmosphere at the South Pole. B-mode
measurements require an instrument with exquisite sensitivity, tight control of
systematics, and wide frequency coverage to disentangle the primordial signal
from the Galactic foregrounds. BICEP Array represents the most recent stage of
the BK program, and comprises four BICEP3-class receivers observing at 30/40,
95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South
Pole during the 2019/2020 austral summer. After 3 full years of observations
with 30,000+ detectors, BICEP Array will measure primordial gravitational waves
to a precision $\sigma(r)$ between 0.002 and 0.004, depending on foreground
complexity and the degree of lensing removal. In this paper we give an overview
of the instrument, highlighting the design features in terms of cryogenics,
magnetic shielding, detectors and readout architecture as well as reporting on
the integration and tests that are ongoing with the first receiver at 30/40
GHz.
[3]
oai:arXiv.org:2002.05254 [pdf] - 2048106
Optical Design and Characterization of 40-GHz Detector and Module for
the BICEP Array
Soliman, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
OBrient, R.;
Palladino, S.;
Prouve, T.;
Precup, N.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Schillaci, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Families of cosmic inflation models predict a primordial gravitational-wave
background that imprints B-mode polarization pattern in the Cosmic Microwave
Background (CMB). High sensitivity instruments with wide frequency coverage and
well-controlled systematic errors are needed to constrain the faint B-mode
amplitude. We have developed antenna-coupled Transition Edge Sensor (TES)
arrays for high-sensitivity polarized CMB observations over a wide range of
millimeter-wave bands. BICEP Array, the latest phase of the BICEP/Keck
experiment series, is a multi-receiver experiment designed to search for
inflationary B-mode polarization to a precision $\sigma$(r) between 0.002 and
0.004 after 3 full years of observations, depending on foreground complexity
and the degree of lensing removal. We describe the electromagnetic design and
measured performance of BICEP Array low-frequency 40-GHz detector, their
packaging in focal plane modules, and optical characterization including
efficiency and beam matching between polarization pairs. We summarize the
design and simulated optical performance, including an approach to improve the
optical efficiency due to mismatch losses. We report the measured beam maps for
a new broad-band corrugation design to minimize beam differential ellipticity
between polarization pairs caused by interactions with the module housing
frame, which helps minimize polarized beam mismatch that converts CMB
temperature to polarization ($T \rightarrow P$) anisotropy in CMB maps.