sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Pozna, Ester

Normalized to: Pozna, E.

9 article(s) in total. 244 co-authors, from 1 to 4 common article(s). Median position in authors list is 16,0.

[1]  oai:arXiv.org:2002.08868  [pdf] - 2052191
A crucial test for astronomical spectrograph calibration with frequency combs
Comments: 22 pages, 14 figures. View the Nature Astronomy publication under https://rdcu.be/b1tMB . Nature Astronomy article available under https://www.nature.com/articles/s41550-020-1010-x
Submitted: 2020-02-20
Laser frequency combs (LFCs) are well on their way to becoming the next-generation calibration sources for precision astronomical spectroscopy. This development is considered key in the hunt for low-mass rocky exoplanets around solar-type stars whose discovery with the radial-velocity method requires cm/s Doppler precision. In order to prove such precise calibration with an LFC, it must be compared to another calibrator of at least the same precision. Being the best available spectrograph calibrator, this means comparing it to a second - fully independent - LFC. This test had long been pending, but our installation of two LFCs at the ultra-stable spectrograph HARPS presented the so far unique opportunity for simultaneous calibrations with two separate LFCs. Although limited in time, the test results confirm the 1 cm/s stability that has long been anticipated by the astronomical community.
[2]  oai:arXiv.org:1608.02350  [pdf] - 1531216
An overview of the mid-infrared spectro-interferometer MATISSE: science, concept, and current status
Comments: SPIE Astronomical Telescopes and Instrumentation conference, June 2016, 11 pages, 6 Figures
Submitted: 2016-08-08
MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 um, exploring angular scales as small as 3 mas (L band) / 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R ~ 30 to R ~ 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.
[3]  oai:arXiv.org:1501.05822  [pdf] - 925683
The GRAVITY instrument software / High-level software
Comments: 8 pages, 7 figures, published in Proc. SPIE 9146, Optical and Infrared Interferometry IV, 91462B
Submitted: 2015-01-23
GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking, astrometric and imaging instrument for the Very Large Telescope Interferometer (VLTI). It is requiring the development of one of the most complex instrument software systems ever built for an ESO instrument. Apart from its many interfaces and interdependencies, one of the most challenging aspects is the overall performance and stability of this complex system. The three infrared detectors and the fast reflective memory network (RMN) recorder contribute a total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data per night. The detectors, the two instrument Local Control Units (LCUs) as well as the five LCUs running applications under TAC (Tools for Advanced Control) architecture, are interconnected with fast Ethernet, RMN fibers and dedicated fiber connections as well as signals for the time synchronization. Here we give a simplified overview of all subsystems of GRAVITY and their interfaces and discuss two examples of high-level applications during observations: the acquisition procedure and the gathering and merging of data to the final FITS file.
[4]  oai:arXiv.org:1407.3057  [pdf] - 1215613
Concept and optical design of the cross-disperser module for CRIRES+
Comments: 14 pages, 9 figures, 22 tables. Presented at SPIE Astronomical Telescope + Instrumentation 2014 (Ground-based and Airbone Instrumentation for Astronomy 5, 9147-289). To be published in Proceeding of SPIE Volume 9147
Submitted: 2014-07-11
CRIRES, the ESO high resolution infrared spectrometer, is a unique instrument which allows astronomers to access a parameter space which up to now was largely uncharted. In its current setup, it consists of a single-order spectrograph providing long-slit, single-order spectroscopy with resolving power up to R=100,000 over a quite narrow spectral range. This has resulted in sub-optimal efficiency and use of telescope time for all the scientific programs requiring broad spectral coverage of compact objects (e.g. chemical abundances of stars and intergalactic medium, search and characterization of extra-solar planets). To overcome these limitations, a consortium was set-up for upgrading CRIRES to a cross-dispersed spectrometer, called CRIRES+. This paper presents the updated optical design of the crossdispersion module for CRIRES+. This new module can be mounted in place of the current pre-disperser unit. The new system yields a factor of >10 increase in simultaneous spectral coverage and maintains a quite long slit (10"), ideal for observations of extended sources and for precise sky-background subtraction.
[5]  oai:arXiv.org:1407.2785  [pdf] - 1215584
VLTI status update: a decade of operations and beyond
Comments: 10 pages, 7 figures, Proceedings of the SPIE, 9146-19
Submitted: 2014-07-10
We present the latest update of the European Southern Observatory's Very Large Telescope interferometer (VLTI). The operations of VLTI have greatly improved in the past years: reduction of the execution time; better offering of telescopes configurations; improvements on AMBER limiting magnitudes; study of polarization effects and control for single mode fibres; fringe tracking real time data, etc. We present some of these improvements and also quantify the operational improvements using a performance metric. We take the opportunity of the first decade of operations to reflect on the VLTI community which is analyzed quantitatively and qualitatively. Finally, we present briefly the preparatory work for the arrival of the second generation instruments GRAVITY and MATISSE.
[6]  oai:arXiv.org:1406.4234  [pdf] - 862945
Mid-infrared interferometry with K band fringe-tracking I. The VLTI MIDI+FSU experiment
Comments: 11 pages, 13 figures, Accepted for publication in A&A
Submitted: 2014-06-17, last modified: 2014-06-20
Context: A turbulent atmosphere causes atmospheric piston variations leading to rapid changes in the optical path difference of an interferometer, which causes correlated flux losses. This leads to decreased sensitivity and accuracy in the correlated flux measurement. Aims: To stabilize the N band interferometric signal in MIDI (MID-infrared Interferometric instrument), we use an external fringe tracker working in K band, the so-called FSU-A (fringe sensor unit) of the PRIMA (Phase-Referenced Imaging and Micro-arcsecond Astrometry) facility at VLTI. We present measurements obtained using the newly commissioned and publicly offered MIDI+FSU-A mode. A first characterization of the fringe-tracking performance and resulting gains in the N band are presented. In addition, we demonstrate the possibility of using the FSU-A to measure visibilities in the K band. Methods: We analyzed FSU-A fringe track data of 43 individual observations covering different baselines and object K band magnitudes with respect to the fringe-tracking performance. The N band group delay and phase delay values could be predicted by computing the relative change in the differential water vapor column density from FSU-A data. Visibility measurements in the K band were carried out using a scanning mode of the FSU-A. Results: Using the FSU-A K band group delay and phase delay measurements, we were able to predict the corresponding N band values with high accuracy with residuals of less than 1 micrometer. This allows the coherent integration of the MIDI fringes of faint or resolved N band targets, respectively. With that method we could decrease the detection limit of correlated fluxes of MIDI down to 0.5 Jy (vs. 5 Jy without FSU-A) and 0.05 Jy (vs. 0.2 Jy without FSU-A) using the ATs and UTs, respectively. The K band visibilities could be measured with a precision down to ~2%.
[7]  oai:arXiv.org:0812.2328  [pdf] - 19435
Post-processing the VLTI fringe-tracking data: First measurements of stars
Comments:
Submitted: 2008-12-12
At the Very Large Telescope Interferometer, the purpose of the fringe-tracker FINITO is to stabilize the optical path differences between the beams, allowing longer integration times on the scientific instruments AMBER and MIDI. Our goal is to demonstrate the potential of FINITO for providing H-band interferometric visibilities, simultaneously and in addition to its normal fringe-tracking role. We use data obtained during the commissioning of the Reflective Memory Network Recorder at the Paranal observatory. This device has permitted the first recording of all relevant real-time data needed for a proper data-reduction. We show that post-processing the FINITO data allows valuable scientific visibilities to be measured. Over the several hours of our engineering experiment, the intrinsic transfer function is stable at the level of 2%. Such stability would lead to robust measurements of science stars even without the observation of a calibration star within a short period of time. We briefly discuss the current limitations and the potential improvements.
[8]  oai:arXiv.org:astro-ph/0608011  [pdf] - 83888
MACAO-CRIRES, a step towards high-resolution spectroscopy
Comments: SPIE conference 2004, Advances in adaptive optics, 12 pages, 15 figures
Submitted: 2006-08-01
High resolution spectroscopy made an important step ahead 10 years ago, leading for example to the discovery of numerous exoplanets. But the IR did not benefit from this improvement until very recently. CRIRES will provide a dramatic improvement in the 1-5 micron region in this field. Adaptive optics will allow us increasing both flux and angular resolution on its spectra. This paper describes the adaptive optics of CRIRES, its main limitations, its main components, the principle of its calibration with an overview of the methods used and the very first results obtained since it is installed in the laboratory.
[9]  oai:arXiv.org:astro-ph/0608010  [pdf] - 83887
On-sky results of the adaptive optics MACAO for the new IR-spectrograph CRIRES at VLT
Comments: SPIE conference 2006, Advances in adaptive optics, 12 pages, 11 figures
Submitted: 2006-08-01
The adaptive optics MACAO has been implemented in 6 focii of the VLT observatory, in three different flavors. We present in this paper the results obtained during the commissioning of the last of these units, MACAO-CRIRES. CRIRES is a high-resolution spectrograph, which efficiency will be improved by a factor two at least for point-sources observations with a NGS brighter than R=15. During the commissioning, Strehl exceeding 60% have been observed with fair seeing conditions, and a general description of the performance of this curvature adaptive optics system is done.