Normalized to: Pospieszalski, M.
[1]
oai:arXiv.org:1907.13198 [pdf] - 1926525
Room Temperature, Quantum-Limited THz Heterodyne Detection? Not Yet
Submitted: 2019-07-30
In their article, Wang et al. [1] report a new scheme for THz heterodyne
detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the
impressive claim of achieving near quantum-limited sensitivity at room
temperature. Unfortunately, their experimental methodology is incorrect, and
furthermore the paper provides no information on the mixer conversion loss, an
important quantity that could readily have been measured and reported as a
consistency check. The paper thus offers no reliable experimental evidence that
substantiates the claimed sensitivities. To the contrary, the very high value
reported for their photomixer impedance strongly suggests that the conversion
loss is quite poor and that the actual sensitivity is far worse than claimed.
[2]
oai:arXiv.org:1612.00893 [pdf] - 1542837
The Atacama Large Millimeter/submillimeter Array (ALMA) Band-1 Receiver
De Huang, Yau;
Morata, Oscar;
Koch, Patrick Michel;
Kemper, Ciska;
Hwang, Yuh-Jing;
Chiong, Chau-Ching;
Ho, Paul;
Chu, You-Hua;
Huang, Chi-Den;
Liu, Ching-Tang;
Hsieh, Fang-Chia;
Tseng, Yen-Hsiang;
Weng, Shou-Hsien;
Ho, Chin-Ting;
Chiang, Po-Han;
Wu, Hsiao-Ling;
Chang, Chih-Cheng;
Jian, Shou-Ting;
Lee, Chien-Feng;
Lee, Yi-Wei;
Iguchi, Satoru;
Asayama, Shin'ichiro;
Iono, Daisuke;
Gonzalez, Alvaro;
Effland, John;
Saini, Kamaljeet;
Pospieszalski, Marian;
Henke, Doug;
Yeung, Keith;
Finger, Ricardo;
Tapia, Valeria;
Reyes, Nicolas
Submitted: 2016-12-02
The Atacama Large Millimeter/submillimeter Array(ALMA) Band 1 receiver covers
the 35-50 GHz frequency band. Development of prototype receivers, including the
key components and subsystems has been completed and two sets of prototype
receivers were fully tested. We will provide an overview of the ALMA Band 1
science goals, and its requirements and design for use on the ALMA. The
receiver development status will also be discussed and the infrastructure,
integration, evaluation of fully-assembled band 1 receiver system will be
covered. Finally, a discussion of the technical and management challenges
encountered will be presented.
[3]
oai:arXiv.org:1502.01280 [pdf] - 1224317
The GBT 67 -- 93.6 GHz Spectral Line Survey of Orion-KL
Frayer, D. T.;
Maddalena, Ronald J.;
Meijer, M.;
Hough, L.;
White, S.;
Norrod, R.;
Watts, G.;
Stennes, M.;
Simon, R.;
Woody, D.;
Srikanth, S.;
Pospieszalski, M.;
Bryerton, E.;
Whitehead, M.;
Ford, P.;
Mello, M.;
Bloss, M.
Submitted: 2015-02-04
We present a 67--93.6 GHz spectral line survey of Orion-KL with the new 4 mm
Receiver on the Green Bank Telescope (GBT). The survey reaches unprecedented
depths and covers the low-frequency end of the 3 mm atmospheric window which
has been relatively unexplored previously. The entire spectral-line survey is
published electronically for general use by the astronomical community. The
calibration and performance of 4 mm Receiver on the GBT is also summarized.
[4]
oai:arXiv.org:1012.4441 [pdf] - 1042682
A blind detection of a large, complex, Sunyaev--Zel'dovich structure
Consortium, AMI;
:;
Shimwell, T. W.;
Barker, R. W.;
Biddulph, P.;
Bly, D.;
Boysen, R. C.;
Brown, A. R.;
Brown, M. L.;
Clementson, C.;
Crofts, M.;
Culverhouse, T. L.;
Czeres, J.;
Dace, R. J.;
Davies, M. L.;
D'Alessandro, R.;
Doherty, P.;
Duggan, K.;
Ely, J. A.;
Felvus, M.;
Feroz, F.;
Flynn, W.;
Franzen, T. M. O.;
Geisbusch, J.;
Genova-Santos, R.;
Grainge, K. J. B.;
Grainger, W. F.;
Hammett, D.;
Hobson, M. P.;
Holler, C. M.;
Hurley-Walker, N.;
Jilley, R.;
Kaneko, T.;
Kneissl, R.;
Lancaster, K.;
Lasenby, A. N.;
Marshall, P. J.;
Newton, F.;
Norris, O.;
Northrop, I.;
Odell, D. M.;
Olamaie, M.;
Pober, Y. C. Perrott J. C.;
Pooley, G. G.;
Pospieszalski, M. W.;
Quy, V.;
Rodriguez-Gonzalvez, C.;
Saunders, R. D. E.;
Scaife, A. M. M.;
Schammel, M. P.;
Schofield, J.;
Scott, P. F.;
Shaw, C.;
Smith, H.;
Titterington, D. J.;
Velic, M.;
Waldram, E. M.;
West, S.;
Wood, B. A.;
Yassin, G.;
Zwart, J. T. L.
Submitted: 2010-12-20, last modified: 2012-03-22
We present an interesting Sunyaev-Zel'dovich (SZ) detection in the first of
the Arcminute Microkelvin Imager (AMI) 'blind', degree-square fields to have
been observed down to our target sensitivity of 100{\mu}Jy/beam. In follow-up
deep pointed observations the SZ effect is detected with a maximum peak
decrement greater than 8 \times the thermal noise. No corresponding emission is
visible in the ROSAT all-sky X-ray survey and no cluster is evident in the
Palomar all-sky optical survey. Compared with existing SZ images of distant
clusters, the extent is large (\approx 10') and complex; our analysis favours a
model containing two clusters rather than a single cluster. Our Bayesian
analysis is currently limited to modelling each cluster with an ellipsoidal or
spherical beta-model, which do not do justice to this decrement. Fitting an
ellipsoid to the deeper candidate we find the following. (a) Assuming that the
Evrard et al. (2002) approximation to Press & Schechter (1974) correctly gives
the number density of clusters as a function of mass and redshift, then, in the
search area, the formal Bayesian probability ratio of the AMI detection of this
cluster is 7.9 \times 10^4:1; alternatively assuming Jenkins et al. (2001) as
the true prior, the formal Bayesian probability ratio of detection is 2.1
\times 10^5:1. (b) The cluster mass is MT,200 = 5.5+1.2\times 10^14h-1M\odot.
(c) Abandoning a physical model with num- -1.3 70 ber density prior and instead
simply modelling the SZ decrement using a phenomenological {\beta}-model of
temperature decrement as a function of angular distance, we find a central SZ
temperature decrement of -295+36 {\mu}K - this allows for CMB primary
anisotropies, receiver -15 noise and radio sources. We are unsure if the
cluster system we observe is a merging system or two separate clusters.
[5]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[6]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[7]
oai:arXiv.org:1001.4743 [pdf] - 33184
Design, development and verification of the 30 and 44 GHz front-end
modules for the Planck Low Frequency Instrument
Davis, R. J.;
Wilkinson, A.;
Davies, R. D.;
Winder, W. F.;
Roddis, N.;
Blackhurst, E. J.;
Lawson, D.;
Lowe, S. R.;
Baines, C.;
Butlin, M.;
Galtress, A.;
Shepherd, D.;
Aja, B.;
Artal, E.;
Bersanelli, M.;
Butler, R. C.;
Castelli, C.;
Cuttaia, F.;
D'Arcangelo, O.;
Gaier, T.;
Hoyland, R.;
Kettle, D.;
Leonardi, R.;
Mandolesi, N.;
Mennella, A.;
Meinhold, P.;
Pospieszalski, M.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zonca, A.
Submitted: 2010-01-26
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.
[8]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[9]
oai:arXiv.org:0908.3826 [pdf] - 27641
Large Instrument Development for Radio Astronomy
Fisher, J. R.;
Bradley, R. F.;
Brisken, W. F.;
Cotton, W. D.;
Emerson, D. T.;
Kerr, A. R.;
Lacasse, R. J.;
Morgan, M. A.;
Napier, P. J.;
Norrod, R. D.;
Payne, J. M.;
Pospieszalski, M. W.;
Symmes, A.;
Thompson, A. R.;
Webber, J. C.
Submitted: 2009-08-26
This white paper offers cautionary observations about the planning and
development of new, large radio astronomy instruments. Complexity is a strong
cost driver so every effort should be made to assign differing science
requirements to different instruments and probably different sites. The appeal
of shared resources is generally not realized in practice and can often be
counterproductive. Instrument optimization is much more difficult with longer
lists of requirements, and the development process is longer and less
efficient. More complex instruments are necessarily further behind the
technology state of the art because of longer development times. Including
technology R&D in the construction phase of projects is a growing trend that
leads to higher risks, cost overruns, schedule delays, and project de-scoping.
There are no technology breakthroughs just over the horizon that will suddenly
bring down the cost of collecting area. Advances come largely through careful
attention to detail in the adoption of new technology provided by industry and
the commercial market. Radio astronomy instrumentation has a very bright
future, but a vigorous long-term R&D program not tied directly to specific
projects needs to be restored, fostered, and preserved.
[10]
oai:arXiv.org:0901.4540 [pdf] - 20792
Cosmological Results from Five Years of 30 GHz CMB Intensity
Measurements with the Cosmic Background Imager
Sievers, J. L.;
Mason, B. S.;
Weintraub, L.;
Achermann, C.;
Altamirano, P.;
Bond, J. R.;
Bronfman, L.;
Bustos, R.;
Contaldi, C.;
Dickinson, C.;
Jones, M. E.;
May, J.;
Myers, S. T.;
Oyarce, N.;
Padin, S.;
Pearson, T. J.;
Pospieszalski, M.;
Readhead, A. C. S.;
Reeves, R.;
Shepherd, M. C.;
Taylor, A. C.;
Torres, S.
Submitted: 2009-01-28, last modified: 2009-02-05
We present final results on the angular power spectrum of total intensity
anisotropies in the CMB from the CBI. Our analysis includes all primordial
anisotropy data collected between January 2000 and April 2005, and benefits
significantly from an improved maximum likelihood analysis pipeline. It also
includes results from a 30 GHz foreground survey conducted with the Green Bank
Telescope (GBT) which places significant constraints on the possible
contamination due to foreground point sources. We improve on previous CBI
results by about a factor of two in the damping tail. These data confirm, at
~3-sigma, the existence of an excess of power over intrinsic CMB anisotropy on
small angular scales (l > 1800). Using the GBT survey, we find currently known
radio source populations are not capable of generating the power; a new
population of faint sources with steeply rising spectral indices would be
required to explain the excess with sources... We also present a full
cosmological parameter analysis of the new CBI power spectrum... With CBI
alone, the full parameter analysis finds the excess is 1.6-sigma above the
level expected for a sigma_8=0.8 universe. We find the addition of high-l CMB
data substantially improves constraints on cosmic string contributions to the
TT power spectrum as well as the running of the scalar spectral index... We
also present forecasts for what other experiments should see at different
frequencies and angular resolutions given the excess power observed by CBI. We
find that the reported high-l bandpowers from current high resolution CMB
bolometer experiments are consistent with each other and CBI if the excess
power is due to the SZE at the CBI-level of 2.5 +/- 1 times the sigma_8=0.8
standard SZ template. <Abridged>
[11]
oai:arXiv.org:astro-ph/0509203 [pdf] - 316296
Implications of the Cosmic Background Imager Polarization Data
Sievers, J. L.;
Achermann, C.;
Bond, J. R.;
Bronfman, L.;
Bustos, R.;
Contaldi, C. R.;
Dickinson, C.;
Ferreira, P. G.;
Jones, M. E.;
Lewis, A. M.;
Mason, B. S.;
May, J.;
Myers, S. T.;
Padin, S.;
Pearson, T. J.;
Pospieszalski, M.;
Readhead, A. C. S.;
Reeves, R.;
Taylor, A. C.;
Torres, S.
Submitted: 2005-09-08, last modified: 2006-11-09
We present new measurements of the power spectra of the E-mode of CMB
polarization, the temperature T, the cross-correlation of E and T, and upper
limits on the B-mode from 2.5 years of dedicated Cosmic Background Imager (CBI)
observations. Both raw maps and optimal signal images in the uv-plane and real
space show strong detections of the E-mode (11.7 sigma for the EE power
spectrum overall) and no detection of the B-mode. The power spectra are used to
constrain parameters of the flat tilted adiabatic Lambda-CDM models: those
determined from EE and TE bandpowers agree with those from TT, a powerful
consistency check. There is little tolerance for shifting polarization peaks
from the TT-forecast locations, as measured by the angular sound crossing scale
theta = 100 ell_s = 1.03 +/- 0.02 from EE and TE cf. 1.044 +/- 0.005 with the
TT data included. The scope for extra out-of-phase peaks from subdominant
isocurvature modes is also curtailed. The EE and TE measurements of CBI, DASI
and BOOMERANG are mutually consistent, and, taken together rather than singly,
give enhanced leverage for these tests.
[12]
oai:arXiv.org:astro-ph/0409569 [pdf] - 67650
Polarization Observations with the Cosmic Background Imager
Readhead, A. C. S.;
Myers, S. T.;
Pearson, T. J.;
Sievers, J. L.;
Mason, B. S.;
Contaldi, C. R.;
Bond, J. R.;
Bustos, R.;
Altamirano, P.;
Achermann, C.;
Bronfman, L.;
Carlstrom, J. E.;
Cartwright, J. K.;
Casassus, S.;
Dickinson, C.;
Holzapfel, W. L.;
Kovac, J. M.;
Leitch, E. M.;
May, J.;
Padin, S.;
Pogosyan, D.;
Pospieszalski, M.;
Pryke, C.;
Reeves, R.;
Shepherd, M. C.;
Torres, S.
Submitted: 2004-09-23, last modified: 2004-10-28
Polarization observations of the cosmic microwave background with the Cosmic
Background Imager from September 2002 to May 2004 provide a significant
detection of the E-mode polarization and reveal an angular power spectrum of
polarized emission showing peaks and valleys that are shifted in phase by half
a cycle relative to those of the total intensity spectrum. This key agreement
between the phase of the observed polarization spectrum and that predicted
based on the total intensity spectrum provides support for the standard model
of cosmology, in which dark matter and dark energy are the dominant
constituents, the geometry is close to flat, and primordial density
fluctuations are predominantly adiabatic with a matter power spectrum
commensurate with inflationary cosmological models.
[13]
oai:arXiv.org:astro-ph/0301164 [pdf] - 54135
Design, Implementation and Testing of the MAP Radiometers
Jarosik, N.;
Bennett, C. L.;
Halpern, M.;
Hinshaw, G.;
Kogut, A.;
Limon, M.;
Meyer, S. S.;
Page, L.;
Pospieszalski, M.;
Spergel, D. N.;
Tucker, G. S.;
Wilkinson, D. T.;
Wollack, E.;
Wright, E. L.;
Zhang, Z.
Submitted: 2003-01-10, last modified: 2003-02-24
The Microwave Anisotropy Probe (MAP) satellite, launched June 30, 2001, will
produce full sky maps of the cosmic microwave background radiation in 5
frequency bands spanning 20 - 106 GHz. MAP contains 20 differential radiometers
built with High Electron Mobility Transistor (HEMT) amplifiers with passively
cooled input stages. The design and test techniques used to evaluate and
minimize systematic errors and the pre-launch performance of the radiometers
for all five bands are presented.