Normalized to: Ponchant, N.
[1]
oai:arXiv.org:1712.04003 [pdf] - 1666796
The NIKA2 instrument at 30-m IRAM telescope: performance and results
Catalano, A.;
Adam, R.;
Ade, P. A. R.;
P.;
André;
Aussel, H.;
Beelen, A.;
Benoit, A.;
Bideaud, A.;
Billot, N.;
Bourrion, O.;
Calvo, M.;
Comis, B.;
De Petris, M.;
Désert, F. -X.;
Doyle, S.;
Driessen, E. F. C.;
Goupy, J.;
Kramer, C.;
Lagache, G.;
Leclercq, S.;
Lestrade, J. -F.;
Macìas-Pérez, J. F.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pascale, E.;
Perotto, L.;
Pisano, G.;
Ponthieu, N.;
Revéret, V.;
Ritacco, A.;
Romero, C.;
Roussel, H.;
Ruppin, F.;
Schuster, K.;
Sievers, A.;
Triqueneaux, S.;
Tucker, C.;
Zylka, R.;
Barria, E.;
Bres, G.;
Camus, P.;
Chanthib, P.;
Donnier-Valentin, G.;
Exshaw, O.;
Garde, G.;
Gerardin, A.;
Leggeri, J. -P.;
Levy-Bertrand, F.;
Guttin, C.;
Hoarau, C.;
Grollier, M.;
Mocellin, J. -L.;
Pont, G.;
Rodenas, H.;
Tissot, O.;
Galvez, G.;
John, D.;
Ungerechts, H.;
Sanchez, S.;
Mellado, P.;
Munoz, M.;
Pierfederici, F.;
Penalver, J.;
Navarro, S.;
Bosson, G.;
Bouly, J. -L.;
Bouvier, J.;
Geraci, C.;
Li, C.;
Menu, J.;
Ponchant, N.;
Roni, S.;
Roudier, S.;
Scordillis, J. P.;
Tourres, D.;
Vescovi, C.;
Barbier, A.;
Billon-Pierron, D.;
Adane, A.;
Andrianasolo, A .;
Bracco, A.;
Coiffard, G.;
Evans, R.;
Maury, A.;
Rigby, A.
Submitted: 2017-12-11, last modified: 2018-02-04
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and
commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band
camera operating with three frequency multiplexed kilo-pixels arrays of Lumped
Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to
observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and
2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy,
such as Intra Cluster Medium from intermediate to distant clusters and so for
the follow-up of Planck satellite detected clusters, high redshift sources and
quasars, early stages of star formation and nearby galaxies emission. We
present an overview of the instrument performance as it has been evaluated at
the end of the commissioning phase.
[2]
oai:arXiv.org:1602.01288 [pdf] - 1530458
NIKEL_AMC: Readout electronics for the NIKA2 experiment
Bourrion, O.;
Benoit, A.;
Bouly, J. L.;
Bouvier, J.;
Bosson, G.;
Calvo, M.;
Catalano, A.;
Goupy, J.;
Li, C.;
Macías-Pérez, J. F.;
Monfardini, A.;
Tourres, D.;
Ponchant, N.;
Vescovi, C.
Submitted: 2016-02-03, last modified: 2016-10-25
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at
the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to
mm-wave astronomy using microwave kinetic inductance detectors (KID) as
sensors. The three arrays installed in the camera, two at 1.25 mm and one at
2.05 mm, feature a total of 3300 KIDs. To instrument these large array of
detectors, a specifically designed electronics, composed of 20 readout boards
and hosted in three microTCA crates, has been developed. The implemented
solution and the achieved performances are presented in this paper. We find
that multiplexing factors of up to 400 detectors per board can be achieved with
homogeneous performance across boards in real observing conditions, and a
factor of more than 3 decrease in volume with respect to previous generations.