Normalized to: Podviianiuk, R.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:1907.12771 [pdf] - 2021183
Search for Light Dark Matter Interactions Enhanced by the Migdal effect
or Bremsstrahlung in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gaemers, P.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hils, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-07-30, last modified: 2019-12-24
Direct dark matter detection experiments based on a liquid xenon target are
leading the search for dark matter particles with masses above $\sim$ 5
GeV/c$^2$, but have limited sensitivity to lighter masses because of the small
momentum transfer in dark matter-nucleus elastic scattering. However, there is
an irreducible contribution from inelastic processes accompanying the elastic
scattering, which leads to the excitation and ionization of the recoiling atom
(the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter,
we report on a probe of low-mass dark matter with masses down to about 85
MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and
Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of
detecting both scintillation and ionization signals, we exploit an approach
that uses ionization signals only, which allows for a lower detection
threshold. This analysis significantly enhances the sensitivity of XENON1T to
light dark matter previously beyond its reach.
[3]
oai:arXiv.org:1907.11485 [pdf] - 2015750
Light Dark Matter Search with Ionization Signals in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gaemers, P.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hils, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-07-26, last modified: 2019-12-17
We report constraints on light dark matter (DM) models using ionization
signals in the XENON1T experiment. We mitigate backgrounds with strong event
selections, rather than requiring a scintillation signal, leaving an effective
exposure of $(22 \pm 3)$ tonne-days. Above
$\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe $<1 \,
\text{event}/(\text{tonne} \times \text{day} \times \text{keV}_\text{ee})$,
which is more than one thousand times lower than in similar searches with other
detectors. Despite observing a higher rate at lower energies, no DM or CEvNS
detection may be claimed because we cannot model all of our backgrounds. We
thus exclude new regions in the parameter spaces for DM-nucleus scattering for
DM masses $m_\chi$ within $3-6\,\mathrm{GeV}/\mathrm{c}^2$, DM-electron
scattering for $m_\chi > 30\,\mathrm{MeV}/\mathrm{c}^2$, and absorption of dark
photons and axion-like particles for $m_\chi$ within $0.186 - 1 \,
\mathrm{keV}/\mathrm{c}^2$.
[4]
oai:arXiv.org:1902.03234 [pdf] - 1875324
Constraining the Spin-Dependent WIMP-Nucleon Cross Sections with XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Antochi, V. C.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Xu, Z.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-02-08, last modified: 2019-04-30
We report the first experimental results on spin-dependent elastic weakly
interacting massive particle (WIMP) nucleon scattering from the XENON1T dark
matter search experiment. The analysis uses the full ton year exposure of
XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No
significant signal excess is observed, and a profile likelihood ratio analysis
is used to set exclusion limits on the WIMP-nucleon interactions. This includes
the most stringent constraint to date on the WIMP-neutron cross section, with a
minimum of $6.3\times10^{-42}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence
level. The results are compared with those from collider searches and used to
exclude new parameter space in an isoscalar theory with an axial-vector
mediator.
[5]
oai:arXiv.org:1811.12482 [pdf] - 1836537
First results on the scalar WIMP-pion coupling, using the XENON1T
experiment
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Antochi, V. C.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kaminsky, B.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.;
Hoferichter, M.;
Klos, P.;
Menéndez, J.;
Schwenk, A.
Submitted: 2018-11-29, last modified: 2019-02-22
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr
of exposure with the XENON1T experiment. This interaction is generated when the
WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In
contrast to most non-relativistic operators, these pion-exchange currents can
be coherently enhanced by the total number of nucleons, and therefore may
dominate in scenarios where spin-independent WIMP-nucleon interactions are
suppressed. Moreover, for natural values of the couplings, they dominate over
the spin-dependent channel due to their coherence in the nucleus. Using the
signal model of this new WIMP-pion channel, no significant excess is found,
leading to an upper limit cross section of $6.4\times10^{-46}$ cm$^2$ (90 %
confidence level) at 30 GeV/c$^2$ WIMP mass.
[6]
oai:arXiv.org:1805.12562 [pdf] - 1749718
Dark Matter Search Results from a One Tonne$\times$Year Exposure of
XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Grandi, L.;
Greene, Z.;
Qiu, H.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Itay, R.;
Joerg, F.;
Kaminsky, B.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Mahlstedt, J.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.
Submitted: 2018-05-31, last modified: 2018-09-13
We report on a search for Weakly Interacting Massive Particles (WIMPs) using
278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T
utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30
\pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of
interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$),
exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\
-3}\textrm{ (sys)}\pm3\textrm{ (stat)})$
events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant
excess over background is found and a profile likelihood analysis parameterized
in spatial and energy dimensions excludes new parameter space for the
WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses
above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30
GeV/c${}^2$ and 90% confidence level.
[7]
oai:arXiv.org:1601.03729 [pdf] - 1382109
Improved dark matter search results from PICO-2L Run 2
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Das, M.;
Debris, F.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Olson, S.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2016-01-14, last modified: 2016-03-25
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$
bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic
threshold energy of 3.3$\,$keV. These data show that measures taken to control
particulate contamination in the superheated fluid resulted in the absence of
the anomalous background events observed in the first run of this bubble
chamber. One single nuclear-recoil event was observed in the data, consistent
both with the predicted background rate from neutrons and with the observed
rate of unambiguous multiple-bubble neutron scattering events. The chamber
exhibits the same excellent electron-recoil and alpha decay rejection as was
previously reported. These data provide the most stringent direct detection
constraints on weakly interacting massive particle (WIMP)-proton spin-dependent
scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
[8]
oai:arXiv.org:1510.07754 [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Grandison, A.;
Hai, M.;
Hall, J.;
Harris, O.;
Jin, M.;
Krauss, C. B.;
Fallows, S.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Ramberg, E.;
Robinson, A. E.;
Rucinski, R.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Simon, P.;
Sonnenschein, A.;
Štekl, I.;
Vàzquez-Jàuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.;
Shkrob, I. A.
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector,
a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB
underground laboratory. PICO-60 is the largest bubble chamber to search for
dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60
exhibits the same excellent background rejection observed in smaller bubble
chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic
calorimetry, similar but not identical to that reported recently in a
C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown
background events, exhibiting acoustic, spatial, and timing behaviors
inconsistent with those expected from a dark matter signal. These behaviors
allow for analysis cuts to remove all background events while retaining
$48.2\%$ of the exposure. Stringent limits on weakly interacting massive
particles interacting via spin-dependent proton and spin-independent processes
are set, and most interpretations of the DAMA/LIBRA modulation signal as dark
matter interacting with iodine nuclei are ruled out.
[9]
oai:arXiv.org:1503.00008 [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hai, M.;
Hall, J.;
Harris, O.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vàzquez-Jaùregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble
chamber in the 2100 meter deep SNOLAB underground laboratory, with a total
exposure of 211.5 kg-days at four different recoil energy thresholds ranging
from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron
recoil and alpha rejection capabilities at very low thresholds, including the
first observation of a dependence of acoustic signal on alpha energy. Twelve
single nuclear recoil event candidates were observed during the run. The
candidate events exhibit timing characteristics that are not consistent with
the hypothesis of a uniform time distribution, and no evidence for a dark
matter signal is claimed. These data provide the most sensitive direct
detection constraints on WIMP-proton spin-dependent scattering to date, with
significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon
scattering.