Normalized to: Poczulp, G.
[1]
oai:arXiv.org:1807.09371 [pdf] - 1722529
Fabrication of the DESI Corrector Lenses
Miller, Timothy N.;
Besuner, Robert W.;
Levi, Michael E.;
Lampton, Michael;
Jelinsky, Patrick;
Heetderks, Henry;
Schlegel, David J.;
Edelstein, Jerry;
Doel, Peter;
Brooks, David;
Kent, Stephen;
Poczulp, Gary;
Sholl, Michael J.
Submitted: 2018-07-24
The Dark Energy Spectroscopic Instrument (DESI) is under construction to
measure the expansion history of the Universe using the Baryon Acoustic
Oscillation technique. The spectra of 35 million galaxies and quasars over
14000 square degrees will be measured during the life of the experiment. A new
prime focus corrector for the KPNO Mayall telescope will deliver light to 5000
fiber optic positioners. The fibers in turn feed ten broad-band spectrographs.
We describe the DESI corrector optics, a series of six fused silica and
borosilicate lenses. The lens diameters range from 0.8 to 1.1 meters, and their
weights 84 to 237 kg. Most lens surfaces are spherical, and two are challenging
10th-order polynomial aspheres. The lenses have been successfully polished and
treated with an antireflection coating at multiple subcontractors, and are now
being integrated into the DESI corrector barrel assembly at University College
London. We describe the final performance of the lenses in terms of their
various parameters, including surface figure, homogeneity, and others, and
compare their final performance against the demanding DESI corrector
requirements. Also we describe the reoptimization of the lens spacing in their
corrector barrel after their final measurements are known. Finally we assess
the performance of the corrector as a whole, compared to early budgeted
estimates.
[2]
oai:arXiv.org:1806.01913 [pdf] - 1695375
The WIYN One Degree Imager in 2018: An Extended 30-Detector Focal Plane
Harbeck, Daniel R.;
Lesser, Mike;
Liu, Wilson;
Stupak, Bob;
George, Ron;
Harris, Ron;
Poczulp, Gary;
Rajagopal, Jayadev;
Kotulla, Ralf;
Ouellete, David;
Hooper, Eric J.;
Smith, Michael;
Mason, Dustin;
Onaka, Peter;
Chin, Greg;
Hunting, Emily;
Christensen, Robert
Submitted: 2018-06-05
We report on the upgraded One Degree Imager (ODI) at the WIYN 3.5 meter
telescope at the Kitt Peak Observatory after the focal plane was expanded by an
additional seventeen detectors in spring 2015. The now thirty Orthogonal
Transfer Array CCD detectors provide a total field of view of 40' x 48' on the
sky. The newly added detectors underwent a design revision to mitigate reduced
charge transfer efficiency under low light conditions. We discuss the
performance of the focal plane and challenges in the photometric calibration of
the wide field of view, helped by the addition of telescope baffles. In a
parallel project, we upgraded the instrument's three filter arm mechanisms,
where a degrading worm-gear mechanism was replaced by a chain drive that is
operating faster and with high reliability. Three more filters, a u' band and
two narrow band filters were added to the instrument's complement, with two
additional narrow band filters currently in procurement (including an H-alpha
filter). We review the lessons learned during nearly three years of operating
the instrument in the observatory environment and discuss infrastructure
upgrades that were driven by ODI's needs.
[3]
oai:arXiv.org:1411.5667 [pdf] - 904151
LSST optical beam simulator
Submitted: 2014-11-20
We describe a camera beam simulator for the LSST which is capable of
illuminating a 60mm field at f/1.2 with realistic astronomical scenes, enabling
studies of CCD astrometric and photometric performance. The goal is to fully
simulate LSST observing, in order to characterize charge transport and other
features in the thick fully depleted CCDs and to probe low level systematics
under realistic conditions. The automated system simulates the centrally
obscured LSST beam and sky scenes, including the spectral shape of the night
sky. The doubly telecentric design uses a nearly unit magnification design
consisting of a spherical mirror, three BK7 lenses, and one beam-splitter
window. To achieve the relatively large field the beam-splitter window is used
twice. The motivation for this LSST beam test facility was driven by the need
to fully characterize a new generation of thick fully-depleted CCDs, and assess
their suitability for the broad range of science which is planned for LSST. Due
to the fast beam illumination and the thick silicon design [each pixel is 10
microns wide and over 100 microns deep] at long wavelengths there can be
effects of photon transport and charge transport in the high purity silicon.
The focal surface covers a field more than sufficient for a 40x40 mm LSST CCD.
Delivered optical quality meets design goals, with 50% energy within a 5 micron
circle. The tests of CCD performance are briefly described.
[4]
oai:arXiv.org:1407.4541 [pdf] - 1215734
KOSMOS and COSMOS: New facility instruments for the NOAO 4-meter
telescopes
Martini, Paul;
Elias, J.;
Points, S.;
Sprayberry, D.;
Derwent, M. A.;
Gonzalez, R.;
Mason, J. A.;
O'Brien, T. P.;
Pappalardo, D. P.;
Pogge, R. W.;
Stoll, R.;
Zhelem, R.;
Daly, P.;
Fitzpatrick, M.;
George, J. R.;
Hunten, M.;
Marshall, R.;
Poczulp, G.;
Rath, S.;
Seaman, R.;
Trueblood, M.;
Zelaya, K.
Submitted: 2014-07-16
We describe the design, construction and measured performance of the Kitt
Peak Ohio State Multi-Object Spectrograph (KOSMOS) for the 4-m Mayall telescope
and the Cerro Tololo Ohio State Multi-Object Spectrograph (COSMOS) for the 4-m
Blanco telescope. These nearly identical imaging spectrographs are modified
versions of the OSMOS instrument; they provide a pair of new, high-efficiency
instruments to the NOAO user community. KOSMOS and COSMOS may be used for
imaging, long-slit, and multi-slit spectroscopy over a 100 square arcminute
field of view with a pixel scale of 0.29 arcseconds. Each contains two VPH
grisms that provide R~2500 with a one arcsecond slit and their wavelengths of
peak diffraction efficiency are approximately 510nm and 750nm. Both may also be
used with either a thin, blue-optimized CCD from e2v or a thick, fully
depleted, red-optimized CCD from LBNL. These instruments were developed in
response to the ReSTAR process. KOSMOS was commissioned in 2013B and COSMOS was
commissioned in 2014A.
[5]
oai:arXiv.org:1407.4542 [pdf] - 1215735
Design of the KOSMOS oil-coupled spectrograph camera lenses
Submitted: 2014-07-16
We present the design details of oil-coupled lens groups used in the KOSMOS
spectrograph camera. The oil-coupled groups use silicone rubber O-rings in a
unique way to accurately center lens elements with high radial and axial
stiffness while also allowing easy assembly. The O-rings robustly seal the oil
within the lens gaps to prevent oil migration. The design of an expansion
diaphragm to compensate for differential expansion due to temperature changes
is described. The issues of lens assembly, lens gap shimming, oil filling and
draining, bubble mitigation, material compatibility, mechanical inspection, and
optical testing are discussed.