Normalized to: Platt, M.
[1]
oai:arXiv.org:2005.00488 [pdf] - 2087554
Removal of $^{210}$Pb by Etch of Crystalline Detector Sidewalls
Submitted: 2020-05-01
A potential source of dominant backgrounds for many rare-event searches or
screening detectors is from radon daughters, specifically $^{210}$Pb, deposited
on detector surfaces, often during detector fabrication. Performing a
late-stage etch is challenging because it may damage the detector. This paper
describes a late-stage etching technique that reduces surface $^{210}$Pb and
$^{210}$Po by $>99\times$ at 90% C.L.
[2]
oai:arXiv.org:1903.06517 [pdf] - 2060101
Single Electron-Hole Pair Sensitive Silicon Detector with Surface Event
Rejection
Hong, Ziqing;
Ren, Runze;
Kurinsky, Noah;
Figueroa-Feliciano, Enectali;
Wills, Lise;
Ganjam, Suhas;
Mahapatra, Rupak;
Mirabolfathi, Nader;
Nebolsky, Brian;
Pinckney, H. Douglas;
Platt, Mark
Submitted: 2019-03-15, last modified: 2020-02-27
We demonstrate single electron-hole pair resolution in a single-sided,
contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a
baseline energy resolution of 3 eV. This crystal can be operated at voltages in
excess of $\pm50$ V, resulting in a measured charge resolution of 0.06
electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device
allows for the discrimination of surface events and separation of events
occurring near the center of the detector from those near the edge. We use this
discrimination ability to show that non-quantized dark events seen in previous
detectors of a similar design are likely dominated by charge leakage along the
side wall of the device.
[3]
oai:arXiv.org:1402.7137 [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Beaty, J.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
DeVaney, D.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Hansen, S.;
Harris, H. R.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Platt, M.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Ruschman, M.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R. L.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs)
using the background rejection capabilities of SuperCDMS. An exposure of 577
kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region
blinded. Eleven events were observed after unblinding. We set an upper limit on
the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2.
This result is in tension with WIMP interpretations of recent experiments and
probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6
GeV/c2.