Normalized to: Pitman, J.
[1]
oai:arXiv.org:1304.0370 [pdf] - 646055
High precision astrometry with a diffractive pupil telescope
Guyon, Olivier;
Bendek, Eduardo A.;
Milster, Thomas D.;
Eisner, Josh A.;
Angel, Roger;
Woolf, Neville J.;
Ammons, Stephen M.;
Shao, Michael;
Shaklan, Stuart;
Levine, Marie;
Nemati, Bijan;
Pitman, Joe;
Woodruff, Robert A.;
Belikov, Ruslan
Submitted: 2013-04-01
Astrometric detection and mass determination of Earth-mass exoplanets
requires sub-microarcsec accuracy, which is theoretically possible with an
imaging space telescope using field stars as an astrometric reference. The
measurement must however overcome astrometric distortions which are much larger
than the photon noise limit. To address this issue, we propose to generate
faint stellar diffraction spikes using a two-dimensional grid of regularly
spaced small dark spots added to the surface of the primary mirror (PM).
Accurate astrometric motion of the host star is obtained by comparing the
position of the spikes to the background field stars. The spikes do not
contribute to scattered light in the central part of the field and therefore
allow unperturbed coronagraphic observation of the star's immediate
surrounding. Because the diffraction spikes are created on the PM and imaged on
the same focal plane detector as the background stars, astrometric distortions
affect equally the diffraction spikes and the background stars, and are
therefore calibrated. We describe the technique, detail how the data collected
by the wide-field camera are used to derive astrometric motion, and identify
the main sources of astrometric error using numerical simulations and
analytical derivations. We find that the 1.4 m diameter telescope, 0.3 sq.deg
field we adopt as a baseline design achieves 0.2 microarcsec single measurement
astrometric accuracy. The diffractive pupil concept thus enables
sub-microarcsec astrometry without relying on the accurate pointing, external
metrology or high stability hardware required with previously proposed high
precision astrometry concepts.
[2]
oai:arXiv.org:1304.0373 [pdf] - 646056
Simultaneous Exoplanet Characterization and deep wide-field imaging with
a diffractive pupil telescope
Guyon, Olivier;
Eisner, Josh A.;
Angel, Roger;
Woolf, Neville J.;
Bendek, Eduardo A.;
Milster, Thomas D.;
Ammons, Stephen M.;
Shao, Michael;
Shaklan, Stuart;
Levine, Marie;
Nemati, Bijan;
Martinache, Frantz;
Pitman, Joe;
Woodruff, Robert A.;
Belikov, Ruslan
Submitted: 2013-04-01
High-precision astrometry can identify exoplanets and measure their orbits
and masses, while coronagraphic imaging enables detailed characterization of
their physical properties and atmospheric compositions through spectroscopy. In
a previous paper, we showed that a diffractive pupil telescope (DPT) in space
can enable sub-microarcsecond accuracy astrometric measurements from wide-field
images by creating faint but sharp diffraction spikes around the bright target
star. The DPT allows simultaneous astrometric measurement and coronagraphic
imaging, and we discuss and quantify in this paper the scientific benefits of
this combination for exoplanet science investigations: identification of
exoplanets with increased sensitivity and robustness, and ability to measure
planetary masses to high accuracy. We show how using both measurements to
identify planets and measure their masses offers greater sensitivity and
provides more reliable measurements than possible with separate missions, and
therefore results in a large gain in mission efficiency. The combined
measurements reliably identify potentially habitable planets in multiple
systems with a few observations, while astrometry or imaging alone would
require many measurements over a long time baseline. In addition, the combined
measurement allows direct determination of stellar masses to percent-level
accuracy, using planets as test particles. We also show that the DPT maintains
the full sensitivity of the telescope for deep wide-field imaging, and is
therefore compatible with simultaneous scientific observations unrelated to
exoplanets. We conclude that astrometry, coronagraphy, and deep wide-field
imaging can be performed simultaneously on a single telescope without
significant negative impact on the performance of any of the three techniques.
[3]
oai:arXiv.org:0911.3200 [pdf] - 30738
Terrestrial Planet Finder Coronagraph (TPF-C) Flight Baseline Concept
Levine, Marie;
Lisman, D.;
Shaklan, S.;
Kasting, J.;
Traub, W.;
Alexander, J.;
Angel, R.;
Blaurock, C.;
Brown, M.;
Brown, R.;
Burrows, C.;
Clampin, M.;
Cohen, E.;
Content, D.;
Dewell, L.;
Dumont, P.;
Egerman, R.;
Ferguson, H.;
Ford, V.;
Greene, J.;
Guyon, O.;
Hammel, H.;
Heap, S.;
Ho, T.;
Horner, S.;
Hunyadi, S.;
Irish, S.;
Jackson, C.;
Kasdin, J.;
Kissil, A.;
Krim, M.;
Kuchner, M.;
Kwack, E.;
Lillie, C.;
Lin, D.;
Liu, A.;
Marchen, L.;
Marley, M.;
Meadows, V.;
Mosier, G.;
Mouroulis, P.;
Noecker, M.;
Ohl, R.;
Oppenheimer, B.;
Pitman, J.;
Ridgway, S.;
Sabatke, E.;
Seager, S.;
Shao, M.;
Smith, A.;
Soummer, R.;
Stapelfeldt, K.;
Tenerell, D.;
Trauger, J.;
Vanderbei, R.
Submitted: 2009-11-16
The Terrestrial Planet Finder Coronagraph (TPF-C) mission presented here is
an existence proof for a flagship-class internal coronagraph space mission
capable of detecting and characterizing Earth-like planets and planetary
systems at visible wavelengths around nearby stars, using an existing launch
vehicle. TPF-C will use spectroscopy to measure key properties of exoplanets
including the presence of atmospheric water or oxygen, powerful signatures in
the search for habitable worlds.