Normalized to: Pietraszewski, C.
[1]
oai:arXiv.org:0908.1629 [pdf] - 1003408
MMTF: The Maryland-Magellan Tunable Filter
Veilleux, S.;
Weiner, B. J.;
Rupke, D. S. N.;
McDonald, M.;
Birk, C.;
Bland-Hawthorn, J.;
Dressler, A.;
Hare, T.;
Osip, D.;
Pietraszewski, C.;
Vogel, S. N.
Submitted: 2009-08-12, last modified: 2009-11-07
This paper describes the Maryland-Magellan Tunable Filter (MMTF) on the
Magellan-Baade 6.5-meter telescope. MMTF is based on a 150-mm clear aperture
Fabry-Perot (FP) etalon that operates in low orders and provides transmission
bandpass and central wavelength adjustable from ~5 to ~15 A and from ~5000 to
over ~9200 A, respectively. It is installed in the Inamori Magellan Areal
Camera and Spectrograph (IMACS) and delivers an image quality of ~0.5" over a
field of view of 27' in diameter (monochromatic over ~10'). This versatile and
easy-to-operate instrument has been used over the past three years for a wide
variety of projects. This paper first reviews the basic principles of FP
tunable filters, then provides a detailed description of the hardware and
software associated with MMTF and the techniques developed to observe with this
instrument and reduce the data. The main lessons learned in the course of the
commissioning and implementation of MMTF are highlighted next, before
concluding with a brief outlook on the future of MMTF and of similar facilities
which are soon coming on line.
[2]
oai:arXiv.org:0710.3750 [pdf] - 6213
An Imaging Fabry-Perot System for the Robert Stobie Spectrograph on the
Southern African Large Telescope
Submitted: 2007-10-19, last modified: 2008-02-26
We present the design of the Fabry-Perot system of the Robert Stobie
Spectrograph on the 10-meter class Southern African Large Telescope and its
characterization as measured in the laboratory. This system provides
spectroscopic imaging at any desired wavelength spanning a bandpass 430 - 860
nm, at four different spectral resolving powers ranging from 300 to 9000. Our
laboratory tests revealed a wavelength dependence of the etalon gap and
parallelism with a maximum variation between 600 - 720 nm that arises because
of the complex structure of the broadband multi-layer dielectric coatings. We
also report an unanticipated optical effect of this multi-layer coating
structure that produces a significant, and wavelength dependent, change in the
apparent shape of the etalon plates. This change is caused by two effects: the
physical non-uniformities or thickness variations in the coating layers, and
the wavelength dependence of the phase change upon refection that can amplify
these non-uniformities. We discuss the impact of these coating effects on the
resolving power, finesse, and throughput of the system. This Fabry-Perot system
will provide a powerful tool for imaging spectroscopy on one of the world's
largest telescopes.