Normalized to: Pessina, G.
[1]
oai:arXiv.org:1711.01482 [pdf] - 2082284
Results of the first NaI scintillating calorimeter prototypes by COSINUS
COSINUS collaboration;
Reindl, F.;
Angloher, G.;
Carniti, P.;
Cassina, L.;
Gironi, L.;
Gotti, C.;
Gütlein, A.;
Maino, M.;
Mancuso, M.;
Di Marco, N.;
Pagnanini, L.;
Pessina, G.;
Petricca, F.;
Pirro, S.;
Pröbst, F.;
Puig, R.;
Schäffner, K.;
Schieck, J.
Submitted: 2017-11-04
Over almost three decades the TAUP conference has seen a remarkable momentum
gain in direct dark matter search. An important accelerator were first
indications for a modulating signal rate in the DAMA/NaI experiment reported in
1997. Today the presence of an annual modulation, which matches in period and
phase the expectation for dark matter, is supported at > 9$\sigma$ confidence.
The underlying nature of dark matter, however, is still considered an open and
fundamental question of particle physics. No other direct dark matter search
could confirm the DAMA claim up to now; moreover, numerous null-results are in
clear contradiction under so-called standard assumptions for the dark matter
halo and the interaction mechanism of dark with ordinary matter. As both bear a
dependence on the target material, resolving this controversial situation will
convincingly only be possible with an experiment using sodium iodide (NaI) as
target. COSINUS aims to even go a step further by combining NaI with a novel
detection approach. COSINUS aims to operate NaI as a cryogenic calorimeter
reading scintillation light and phonon/heat signal. Two distinct advantages
arise from this approach, a substantially lower energy threshold for nuclear
recoils and particle identification on an event-by-event basis. These key
benefits will allow COSINUS to clarify a possible nuclear recoil origin of the
DAMA signal with comparatively little exposure of O(100kg days) and, thereby,
answer a long-standing question of particle physics. Today COSINUS is in R&D
phase; in this contribution we show results from the 2nd prototype, albeit the
first one of the final foreseen detector design. The key finding of this
measurement is that pure, undoped NaI is a truly excellent scintillator at low
temperatures: We measure 13.1% of the total deposited energy in the NaI crystal
in the form of scintillation light (in the light detector).
[2]
oai:arXiv.org:1610.03876 [pdf] - 1580394
The COSINUS project - a NaI-based cryogenic calorimeter for direct dark
matter detection
Angloher, G.;
Carniti, P.;
Cassina, L.;
Gironi, L.;
Gotti, C.;
Gütlein, A.;
Hauff, D.;
Maino, M.;
Nagorny, S. S.;
Pagnanini, L.;
Pessina, G.;
Petricca, F.;
Pirro, S.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Seidel, W.
Submitted: 2016-10-12
At present the results in the field of direct dark matter search are in
tension: the positive claim of DAMA/LIBRA versus null results from other
experiments. However, the comparison of the results of different experiments
involves model dependencies, in particular because of the different target
materials in use. The COSINUS R&D project aims to operate NaI as a cryogenic
calorimeter. Such a detector would not only allow for a direct comparison to
DAMA/LIBRA, but would also provide a low(er) nuclear recoil threshold and
particle discrimination.
[3]
oai:arXiv.org:1209.2519 [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter
perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.;
Ardito, R.;
Artusa, D. R.;
Avignone, F. T.;
Azzolini, O.;
Balata, M.;
Banks, T. I.;
Bari, G.;
Beeman, J.;
Bellini, F.;
Bersani, A.;
Biassoni, M.;
Bloxham, T.;
Brofferio, C.;
Bucci, C.;
Cai, X. Z.;
Canonica, L.;
Capelli, S.;
Carbone, L.;
Cardani, L.;
Carrettoni, M.;
Casali, N.;
Chott, N.;
Clemenza, M.;
Cosmelli, C.;
Cremonesi, O.;
Creswick, R. J.;
Dafinei, I.;
Dally, A.;
Datskov, V.;
De Biasi, A.;
Decowski, M. P.;
Deninno, M. M.;
Di Domizio, S.;
di Vacri, M. L.;
Ejzak, L.;
Faccini, R.;
Fang, D. Q.;
Farach, H. A.;
Ferri, E.;
Ferroni, F.;
Fiorini, E.;
Franceschi, M. A.;
Freedman, S. J.;
Frossati, G.;
Fujikawa, B. K.;
Giachero, A.;
Gironi, L.;
Giuliani, A.;
Goett, J. J.;
Gorla, P.;
Gotti, C.;
Guardincerri, E.;
Gutierrez, T. D.;
Haller, E. E.;
Han, K.;
Heeger, K. M.;
Huang, H. Z.;
Kadel, R.;
Kazkaz, K.;
Keppel, G.;
Kogler, L.;
Kolomensky, Yu. G.;
Lenz, D.;
Li, Y. L.;
Ligi, C.;
Liu, X.;
Ma, Y. G.;
Maiano, C.;
Maino, M.;
Martinez, M.;
Maruyama, R. H.;
Moggi, N.;
Morganti, S.;
Napolitano, T.;
Newman, S.;
Nisi, S.;
Nones, C.;
Norman, E. B.;
Nucciotti, A.;
Orio, F.;
Orlandi, D.;
Ouellet, J. L.;
Pallavicini, M.;
Palmieri, V.;
Pattavina, L.;
Pavan, M.;
Pedretti, M.;
Pessina, G.;
Pirro, S.;
Previtali, E.;
Rampazzo, V.;
Rimondi, F.;
Rosenfeld, C.;
Rusconi, C.;
Sangiorgio, S.;
Scielzo, N. D.;
Sisti, M.;
Smith, A. R.;
Stivanello, F.;
Taffarello, L.;
Tenconi, M.;
Tian, W. D.;
Tomei, C.;
Trentalange, S.;
Ventura, G.;
Vignati, M.;
Wang, B. S.;
Wang, H. W.;
Whitten, C. A.;
Wise, y T.;
Woodcraft, A.;
Zanotti, L.;
Zarra, C.;
Zhu, B. X.;
Zucchelli, S.
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.