sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Pertenais, Martin

Normalized to: Pertenais, M.

7 article(s) in total. 31 co-authors, from 1 to 5 common article(s). Median position in authors list is 1,0.

[1]  oai:arXiv.org:1907.11549  [pdf] - 1923614
VUV test of a new polarimeter for spectropolarimetric measurements on board space missions
Comments:
Submitted: 2019-07-26
High-resolution spectropolarimetry is a useful astronomical technique, in particular to study stellar magnetic fields. It has been extensively used in the past but mostly in the visible range. Space missions equipped with high-resolution spectropolarimeters working in the ultra-violet (UV) are now being studied. We propose a concept of a polarimeter working with temporal modulation and allowing to perform Stokes IQUV measurements over the full UV + Visible range. The purpose of this article is to describe the polarimeter concept, two prototypes and the bench developed to perform on ground testing to establish the performances of this new polarimeter.
[2]  oai:arXiv.org:1906.00892  [pdf] - 1909336
In-flight photometry extraction of PLATO targets: Optimal apertures for detecting extrasolar planets
Comments: 20 pages, 22 figures, Astronomy & Astrophysics (accepted)
Submitted: 2019-06-03
The ESA PLATO space mission is devoted to unveiling and characterizing new extrasolar planets and their host stars. This mission will encompass a very large field of view, granting it the potential to survey up to one million stars depending on the final observation strategy. The telemetry budget of the spacecraft cannot handle transmitting individual images for such a huge stellar sample at the right cadence, so the development of an appropriate strategy to perform on-board data reduction is mandatory. We employ aperture photometry to produce stellar light curves in flight. Our aim is thus to find the mask model that optimizes the scientific performance of the reduced data. We considered three distinct aperture models: binary mask, weighted Gaussian mask, and weighted gradient mask giving lowest noise-to-signal ratio, computed through a novel direct method. An innovative criterion was adopted for choosing between different mask models. We designated as optimal the model providing the best compromise between sensitivity to detect true and false planet transits. We determined the optimal model based on simulated noise-to-signal ratio and frequency of threshold crossing events. Our results show that, although the binary mask statistically presents a few percent higher noise-to-signal ratio compared to weighted masks, both strategies have very similar efficiency in detecting legitimate planet transits. When it comes to avoiding spurious signals from contaminant stars however the binary mask statistically collects considerably less contaminant flux than weighted masks, thereby allowing the former to deliver up to $\sim$30\% less false transit signatures at $7.1\sigma$. Our proposed approach for choosing apertures has been proven to be decisive for the determination of a mask model capable to provide near maximum planet yield and substantially reduced occurrence of false positives.
[3]  oai:arXiv.org:1903.02747  [pdf] - 1871518
The PLATO Solar-like Light-curve Simulator: A tool to generate realistic stellar light-curves with instrumental effects representative of the PLATO mission
Comments: 19 pages, 16 figures, Astronomy & Astrophysics (in press)
Submitted: 2019-03-07, last modified: 2019-03-23
The preparation of science objectives of the ESA's PLATO space mission will require the implementation of hare-and-hound exercises relying on the massive generation of representative simulated light-curves. We developed a light-curve simulator named the PLATO Solar-like Light-curve Simulator (PSLS) in order to generate light-curves representative of typical PLATO targets, i.e. showing simultaneously solar-like oscillations, stellar granulation, and magnetic activity. At the same time, PSLS also aims at mimicking in a realistic way the random noise and the systematic errors representative of the PLATO multi-telescope concept. To quantify the instrumental systematic errors, we performed a series of simulations at pixel level that include various relevant sources of perturbations expected for PLATO. From the simulated pixels, we extract the photometry as planned on-board. The simulated light-curves are then corrected for instrumental effects using the instrument Point Spread Functions reconstructed on the basis of a microscanning technique that will be operated during the in-flight calibration phases. These corrected light-curves are then fitted by a parametric model, which we incorporated in PSLS. We show that the instrumental systematic errors dominate the signal only at frequencies below 20muHz and are found to mainly depend on stellar magnitude and on the detector charge transfer inefficiency. To illustrate how realistic our simulator is, we compared its predictions with observations made by Kepler on three typical targets and found a good qualitative agreement with the observations. PSLS reproduces the main properties of expected PLATO light-curves. Its speed of execution and its inclusion of relevant stellar signals as well as sources of noises representative of the PLATO cameras make it an indispensable tool for the scientific preparation of the PLATO mission.
[4]  oai:arXiv.org:1509.00627  [pdf] - 1342824
Innovative static spectropolarimeter concept for wide spectral ranges: tolerancing study
Comments: 6 pages, Proceeding SPIE Optics and Photonics, August 2015
Submitted: 2015-09-02
Developing an efficient and robust polarimeter for wide spectral ranges and space applications is a main issue in many projects. As part of the UVMag consortium created to develop UV facilities in space (e.g. the Arago mission proposed to ESA), we are studying an innovative concept of polarimeter that is robust, simple, and efficient on a wide spectral range. The idea, based on the article by Sparks et al. (2012), is to use polarization scramblers to create a spatial modulation of the polarization. Along the height of the wedges of the scramblers, the thickness of the birefringent material crossed by the light, and thus the retardance, vary continuously. This variation creates an intensity modulation of the light related to the entrance polarization state. Analyzing this modulation with a linear polarizer, and dispersing the light spectrally in the orthogonal spatial direction, enables the measurement of the full Stokes vector over the entire spectrum. This determination is performed with a single-shot measurement and without any moving parts in the system. After a quick introduction to the concept and optical design, this article presents the tolerancing study of the optical bench using this spectropolarimeter. The impact of different error sources, such as, birefringence uncertainty or decenter of the wedges, is investigated.
[5]  oai:arXiv.org:1507.06894  [pdf] - 1300245
Static spectropolarimeter concept adapted to space conditions and wide spectrum constraints
Comments: Article accepted for publication in Applied Optics on 20 July 2015
Submitted: 2015-07-24
The issues related to moving elements in space and instruments working in broader wavelength ranges lead to a need for robust polarimeters, efficient on a wide spectral domain, and adapted to space conditions. As part of the UVMag consortium, created to develop spectropolarimetric UV facilities in space, such as the Arago mission project, we present an innovative concept of static spectropolarimetry. We studied a static and polychromatic method for spectropolarimetry, applicable to stellar physics. Instead of modulating the polarization information temporally, as usually done in spectropolarimeters, the modulation is performed in a spatial direction, orthogonal to the spectral one. Thanks to the proportionality between phase retardance imposed by a birefringent material and its thickness, birefringent wedges can be used to create this spatial modulation. The light is then spectrally cross-dispersed, and a full-Stokes determination of the polarization over the whole spectrum can be obtained with a single-shot measurement. The use of Magnesium Fluoride wedges, for example, could lead to a compact, static polarimeter working at wavelengths from 0.115 mm up to 7 mm. We present the theory and simulations of this concept, as well as laboratory validation and a practical application to Arago.
[6]  oai:arXiv.org:1502.00856  [pdf] - 1504413
Preliminary design of the full-Stokes UV and visible spectropolarimeter for UVMag/Arago
Comments: 6 pages, 6 figures, IAUS 305
Submitted: 2015-02-03
The UVMag consortium proposed the space mission project Arago to ESA at its M4 call. It is dedicated to the study of the dynamic 3D environment of stars and planets. This space mission will be equipped with a high-resolution spectropolarimeter working from 119 to 888 nm. A preliminary optical design of the whole instrument has been prepared and is presented here. The design consists of the telescope, the instrument itself, and the focusing optics. Considering not only the scientific requirements, but also the cost and size constraints to fit a M-size mission, the telescope has a 1.3 m diameter primary mirror and is a classical Cassegrain-type telescope that allows a polarization-free focus. The polarimeter is placed at this Cassegrain focus. This is the key element of the mission and the most challenging to be designed. The main challenge lies in the huge spectral range offered by the instrument; the polarimeter has to deliver the full Stokes vector with a high precision from the FUV (119 nm) to the NIR (888 nm). The polarimeter module is then followed by a high-resolution echelle-spectrometer achieving a resolution of 35000 in the visible range and 25000 in the UV. The two channels are separated after the echelle grating, allowing a specific cross-dispersion and focusing optics for the UV and visible ranges. Considering the large field of view and the high numerical aperture, the focusing optic for both the UV and visible channels is a Three-Mirror-Anastigmat (TMA) telescope, in order to focus the various wavelengths and many orders onto the detectors.
[7]  oai:arXiv.org:1406.4378  [pdf] - 1215024
UVMag: Space UV and visible spectropolarimetry
Comments: 9 pages, 4 figures, SPIE Conference Astronomical Telescopes + Instrumentation Montreal June 2014
Submitted: 2014-06-17, last modified: 2014-07-23
UVMag is a project of a space mission equipped with a high-resolution spectropolarimeter working in the UV and visible range. This M-size mission will be proposed to ESA at its M4 call. The main goal of UVMag is to measure the magnetic fields, winds and environment of all types of stars to reach a better understanding of stellar formation and evolution and of the impact of stellar environment on the surrounding planets. The groundbreaking combination of UV and visible spectropolarimetric observations will allow the scientists to study the stellar surface and its environment simultaneously. The instrumental challenge for this mission is to design a high-resolution space spectropolarimeter measuring the full-Stokes vector of the observed star in a huge spectral domain from 117 nm to 870 nm. This spectral range is the main difficulty because of the dispersion of the optical elements and of birefringence issues in the FUV. As the instrument will be launched into space, the polarimetric module has to be robust and therefore use if possible only static elements. This article presents the different design possibilities for the polarimeter at this point of the project.