Normalized to: Pertenais, M.
[1]
oai:arXiv.org:1907.11549 [pdf] - 1923614
VUV test of a new polarimeter for spectropolarimetric measurements on
board space missions
Submitted: 2019-07-26
High-resolution spectropolarimetry is a useful astronomical technique, in
particular to study stellar magnetic fields. It has been extensively used in
the past but mostly in the visible range. Space missions equipped with
high-resolution spectropolarimeters working in the ultra-violet (UV) are now
being studied. We propose a concept of a polarimeter working with temporal
modulation and allowing to perform Stokes IQUV measurements over the full UV +
Visible range. The purpose of this article is to describe the polarimeter
concept, two prototypes and the bench developed to perform on ground testing to
establish the performances of this new polarimeter.
[2]
oai:arXiv.org:1906.00892 [pdf] - 1909336
In-flight photometry extraction of PLATO targets: Optimal apertures for
detecting extrasolar planets
Marchiori, V.;
Samadi, R.;
Fialho, F.;
Paproth, C.;
Santerne, A.;
Pertenais, M.;
Börner, A.;
Cabrera, J.;
Monsky, A.;
Kutrowski, N.
Submitted: 2019-06-03
The ESA PLATO space mission is devoted to unveiling and characterizing new
extrasolar planets and their host stars. This mission will encompass a very
large field of view, granting it the potential to survey up to one million
stars depending on the final observation strategy. The telemetry budget of the
spacecraft cannot handle transmitting individual images for such a huge stellar
sample at the right cadence, so the development of an appropriate strategy to
perform on-board data reduction is mandatory. We employ aperture photometry to
produce stellar light curves in flight. Our aim is thus to find the mask model
that optimizes the scientific performance of the reduced data. We considered
three distinct aperture models: binary mask, weighted Gaussian mask, and
weighted gradient mask giving lowest noise-to-signal ratio, computed through a
novel direct method. An innovative criterion was adopted for choosing between
different mask models. We designated as optimal the model providing the best
compromise between sensitivity to detect true and false planet transits. We
determined the optimal model based on simulated noise-to-signal ratio and
frequency of threshold crossing events. Our results show that, although the
binary mask statistically presents a few percent higher noise-to-signal ratio
compared to weighted masks, both strategies have very similar efficiency in
detecting legitimate planet transits. When it comes to avoiding spurious
signals from contaminant stars however the binary mask statistically collects
considerably less contaminant flux than weighted masks, thereby allowing the
former to deliver up to $\sim$30\% less false transit signatures at
$7.1\sigma$. Our proposed approach for choosing apertures has been proven to be
decisive for the determination of a mask model capable to provide near maximum
planet yield and substantially reduced occurrence of false positives.
[3]
oai:arXiv.org:1903.02747 [pdf] - 1871518
The PLATO Solar-like Light-curve Simulator: A tool to generate realistic
stellar light-curves with instrumental effects representative of the PLATO
mission
Samadi, R.;
Deru, A.;
Reese, D.;
Marchiori, V.;
Grolleau, E.;
Green, J. J.;
Pertenais, M.;
Lebreton, Y.;
Deheuvels, S.;
Mosser, B.;
Belkacem, K.;
Borner, A.;
Smith, A. M. S.
Submitted: 2019-03-07, last modified: 2019-03-23
The preparation of science objectives of the ESA's PLATO space mission will
require the implementation of hare-and-hound exercises relying on the massive
generation of representative simulated light-curves. We developed a light-curve
simulator named the PLATO Solar-like Light-curve Simulator (PSLS) in order to
generate light-curves representative of typical PLATO targets, i.e. showing
simultaneously solar-like oscillations, stellar granulation, and magnetic
activity. At the same time, PSLS also aims at mimicking in a realistic way the
random noise and the systematic errors representative of the PLATO
multi-telescope concept. To quantify the instrumental systematic errors, we
performed a series of simulations at pixel level that include various relevant
sources of perturbations expected for PLATO. From the simulated pixels, we
extract the photometry as planned on-board. The simulated light-curves are then
corrected for instrumental effects using the instrument Point Spread Functions
reconstructed on the basis of a microscanning technique that will be operated
during the in-flight calibration phases. These corrected light-curves are then
fitted by a parametric model, which we incorporated in PSLS. We show that the
instrumental systematic errors dominate the signal only at frequencies below
20muHz and are found to mainly depend on stellar magnitude and on the detector
charge transfer inefficiency. To illustrate how realistic our simulator is, we
compared its predictions with observations made by Kepler on three typical
targets and found a good qualitative agreement with the observations. PSLS
reproduces the main properties of expected PLATO light-curves. Its speed of
execution and its inclusion of relevant stellar signals as well as sources of
noises representative of the PLATO cameras make it an indispensable tool for
the scientific preparation of the PLATO mission.
[4]
oai:arXiv.org:1509.00627 [pdf] - 1342824
Innovative static spectropolarimeter concept for wide spectral ranges:
tolerancing study
Submitted: 2015-09-02
Developing an efficient and robust polarimeter for wide spectral ranges and
space applications is a main issue in many projects. As part of the UVMag
consortium created to develop UV facilities in space (e.g. the Arago mission
proposed to ESA), we are studying an innovative concept of polarimeter that is
robust, simple, and efficient on a wide spectral range. The idea, based on the
article by Sparks et al. (2012), is to use polarization scramblers to create a
spatial modulation of the polarization. Along the height of the wedges of the
scramblers, the thickness of the birefringent material crossed by the light,
and thus the retardance, vary continuously. This variation creates an intensity
modulation of the light related to the entrance polarization state. Analyzing
this modulation with a linear polarizer, and dispersing the light spectrally in
the orthogonal spatial direction, enables the measurement of the full Stokes
vector over the entire spectrum. This determination is performed with a
single-shot measurement and without any moving parts in the system. After a
quick introduction to the concept and optical design, this article presents the
tolerancing study of the optical bench using this spectropolarimeter. The
impact of different error sources, such as, birefringence uncertainty or
decenter of the wedges, is investigated.
[5]
oai:arXiv.org:1507.06894 [pdf] - 1300245
Static spectropolarimeter concept adapted to space conditions and wide
spectrum constraints
Submitted: 2015-07-24
The issues related to moving elements in space and instruments working in
broader wavelength ranges lead to a need for robust polarimeters, efficient on
a wide spectral domain, and adapted to space conditions. As part of the UVMag
consortium, created to develop spectropolarimetric UV facilities in space, such
as the Arago mission project, we present an innovative concept of static
spectropolarimetry. We studied a static and polychromatic method for
spectropolarimetry, applicable to stellar physics. Instead of modulating the
polarization information temporally, as usually done in spectropolarimeters,
the modulation is performed in a spatial direction, orthogonal to the spectral
one. Thanks to the proportionality between phase retardance imposed by a
birefringent material and its thickness, birefringent wedges can be used to
create this spatial modulation. The light is then spectrally cross-dispersed,
and a full-Stokes determination of the polarization over the whole spectrum can
be obtained with a single-shot measurement. The use of Magnesium Fluoride
wedges, for example, could lead to a compact, static polarimeter working at
wavelengths from 0.115 mm up to 7 mm. We present the theory and simulations of
this concept, as well as laboratory validation and a practical application to
Arago.
[6]
oai:arXiv.org:1502.00856 [pdf] - 1504413
Preliminary design of the full-Stokes UV and visible spectropolarimeter
for UVMag/Arago
Submitted: 2015-02-03
The UVMag consortium proposed the space mission project Arago to ESA at its
M4 call. It is dedicated to the study of the dynamic 3D environment of stars
and planets. This space mission will be equipped with a high-resolution
spectropolarimeter working from 119 to 888 nm. A preliminary optical design of
the whole instrument has been prepared and is presented here. The design
consists of the telescope, the instrument itself, and the focusing optics.
Considering not only the scientific requirements, but also the cost and size
constraints to fit a M-size mission, the telescope has a 1.3 m diameter primary
mirror and is a classical Cassegrain-type telescope that allows a
polarization-free focus. The polarimeter is placed at this Cassegrain focus.
This is the key element of the mission and the most challenging to be designed.
The main challenge lies in the huge spectral range offered by the instrument;
the polarimeter has to deliver the full Stokes vector with a high precision
from the FUV (119 nm) to the NIR (888 nm). The polarimeter module is then
followed by a high-resolution echelle-spectrometer achieving a resolution of
35000 in the visible range and 25000 in the UV. The two channels are separated
after the echelle grating, allowing a specific cross-dispersion and focusing
optics for the UV and visible ranges. Considering the large field of view and
the high numerical aperture, the focusing optic for both the UV and visible
channels is a Three-Mirror-Anastigmat (TMA) telescope, in order to focus the
various wavelengths and many orders onto the detectors.
[7]
oai:arXiv.org:1406.4378 [pdf] - 1215024
UVMag: Space UV and visible spectropolarimetry
Submitted: 2014-06-17, last modified: 2014-07-23
UVMag is a project of a space mission equipped with a high-resolution
spectropolarimeter working in the UV and visible range. This M-size mission
will be proposed to ESA at its M4 call. The main goal of UVMag is to measure
the magnetic fields, winds and environment of all types of stars to reach a
better understanding of stellar formation and evolution and of the impact of
stellar environment on the surrounding planets. The groundbreaking combination
of UV and visible spectropolarimetric observations will allow the scientists to
study the stellar surface and its environment simultaneously. The instrumental
challenge for this mission is to design a high-resolution space
spectropolarimeter measuring the full-Stokes vector of the observed star in a
huge spectral domain from 117 nm to 870 nm. This spectral range is the main
difficulty because of the dispersion of the optical elements and of
birefringence issues in the FUV. As the instrument will be launched into space,
the polarimetric module has to be robust and therefore use if possible only
static elements. This article presents the different design possibilities for
the polarimeter at this point of the project.