Normalized to: Perfetto, F.
[2]
oai:arXiv.org:1909.01680 [pdf] - 1955437
The Data Processor of the EUSO-SPB2 Telescopes
Submitted: 2019-09-04
In this paper we present the Data Processor (DP) of EUSO-SPB2 (Extreme
Universe Space Observatory on a Super Pressure Balloon, mission two) telescopes
. The EUSO-SPB2 is the continuation of the JEM-EUSO science program on
ultra-long duration balloons, started with the EUSO-SPB1 mission. The EUSO-SPB2
will host on-board two telescopes. One is a fluorescence telescope designed to
detect high energy cosmic rays via the UV fluorescence emission of the showers
in the atmosphere; the other one measures direct Cherenkov light emission from
lower energy cosmic rays and other optical backgrounds for cosmogenic tau
neutrino detection. The DP is the component of the electronics system which
performs data management and instrument control for each of the two telescopes.
The DP controls front-end electronics, tags events with arrival time and
payload position through a GPS system, provides signals for time
synchronization of the event and measures live and dead time of the telescope.
Furthermore it manages mass memory for data storage and performs housekeeping
monitor and controls the power on and power off sequences. Since a super
pressure balloon may remain airborne up to 100 days, the requirements on the
electronics and data handling are quite severe. The DP operates at high
altitude in unpressurised environment which represents a technological
challenge for heat dissipation. In this paper we describe the main components
of the system and the design developed for the new mission.
[3]
oai:arXiv.org:1909.01682 [pdf] - 1955438
Front-end electronics for the GAPS tracker
Submitted: 2019-09-04
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon-borne
mission to indirectly search for dark matter through sensitive observation of
cosmic antiparticles. The first flight is planned for late 2021. GAPS is the
first experiment optimized specifically for detection of low-energy (< 0.25
GeV/n) antideuterons, which are recognized as distinctive signals from dark
matter annihilation or decay in the Galactic halo. To achieve high sensitivity
to cosmic antinuclei in this low-energy range, GAPS uses a novel particle
identification method based on exotic atom capture and decay. The GAPS
instrument consists of ten planes of 1440 10 cm-diameter, 2.5 mm-thick, 8-strip
lithium drifted silicon (Si(Li)) detectors, which constitutes the tracker,
surrounded by a plastic scintillator time-of-flight system. A new fabrication
technique has been developed to satisfy the stringent requirements of the
mission. In this contribution, we describe the front-end electronics of the
tracker of GAPS. The system is composed of front-end ASICs and power supplies.
The ASICs provide readout and digitization of the signal (with an 11-bit ADC)
in a wide dynamic range (10 keV - 100 MeV). Every ASIC has 32 channels and
performs the readout for 4 detectors, for a total amount of 11520 channels. The
ASIC analog front-end is based on a dynamic compression technique to handle a
large range of signal amplitudes and features a low noise performance,
achieving the required 4 keV resolution at low energies. The power system
supplies both bias voltages for the Si(Li) detectors and low voltages for the
electronics. 36th
[4]
oai:arXiv.org:1808.02557 [pdf] - 1730302
First observations of speed of light tracks by a fluorescence detector
looking down on the atmosphere
Abdellaoui, G.;
Abe, S.;
Adams, J. H.;
Ahriche, A.;
Allard, D.;
Allen, L.;
Alonso, G.;
Anchordoqui, L.;
Anzalone, A.;
Arai, Y.;
Asano, K.;
Attallah, R.;
Attoui, H.;
Pernas, M. Ave;
Bacholle, S.;
Bakiri, M.;
Baragatti, P.;
Barrillon, P.;
Bartocci, S.;
Bayer, J.;
Beldjilali, B.;
Belenguer, T.;
Belkhalfa, N.;
Bellotti, R.;
Belov, A.;
Belov, K.;
Benmessai, K.;
Bertaina, M.;
Biermann, P. L.;
Biktemerova, S.;
Bisconti, F.;
Blanc, N.;
Błȩcki, J.;
Blin-Bondil, S.;
Bobik, P.;
Bogomilov, M.;
Bozzo, E.;
Bruno, A.;
Caballero, K. S.;
Cafagna, F.;
Campana, D.;
Capdevielle, J-N.;
Capel, F.;
Caramete, A.;
Caramete, L.;
Carlson, P.;
Caruso, R.;
Casolino, M.;
Cassardo, C.;
Castellina, A.;
Catalano, C. Catalano O.;
Cellino, A.;
Chikawa, M.;
Chiritoi, G.;
Christl, M. J.;
Connaughton, V.;
Conti, L.;
Cordero, G.;
Cotto, G.;
Crawford, H. J.;
Cremonini, R.;
Csorna, S.;
Cummings, A.;
Dagoret-Campagne, S.;
De Donato, C.;
de la Taille, C.;
De Santis, C.;
del Peral, L.;
Di Martino, M.;
Damian, A. Diaz;
Djemil, T.;
Dutan, I.;
Ebersoldt, A.;
Ebisuzaki, T.;
Engel, R.;
Eser, J.;
Fenu, F.;
Fernández-González, S.;
Fernández-Soriano, J.;
Ferrarese, S.;
Flamini, M.;
Fornaro, C.;
Fouka, M.;
Franceschi, A.;
Franchini, S.;
Fuglesang, C.;
Fujii, T.;
Fujimoto, J.;
Fukushima, M.;
Galeotti, P.;
García-Ortega, E.;
Garipov, G.;
Gascón, E.;
Genci, J.;
Giraudo, G.;
Alvarado, C. González;
Gorodetzky, P.;
Greg, R.;
Guarino, F.;
Guzmán, A.;
Hachisu, Y.;
Haiduc, M.;
Harlov, B.;
Haungs, A.;
Carretero, J. Hernández;
Cruz, W. Hidber;
Ikeda, D.;
Inoue, N.;
Inoue, S.;
Isgrò, F.;
Itow, Y.;
Jammer, T.;
Jeong, S.;
Joven, E.;
Judd, E. G.;
Jung, A.;
Jochum, J.;
Kajino, F.;
Kajino, T.;
Kalli, S.;
Kaneko, I.;
Karadzhov, Y.;
Karczmarczyk, J.;
Katahira, K.;
Kawai, K.;
Kawasaki, Y.;
Kedadra, A.;
Khales, H.;
Khrenov, B. A.;
Kim, Jeong-Sook;
Kim, Soon-Wook;
Kleifges, M.;
Klimov, P. A.;
Kolev, D.;
Krantz, H.;
Kreykenbohm, I.;
Kudela, K.;
Kurihara, Y.;
Kusenko, A.;
Kuznetsov, E.;
La Barbera, A.;
Lachaud, C.;
Lahmar, H.;
Lakhdari, F.;
Larson, R.;
Larsson, O.;
Lee, J.;
Licandro, J.;
Campano, L. López;
Maccarone, M. C.;
Mackovjak, S.;
Mahdi, M.;
Maravilla, D.;
Marcelli, L.;
Marcos, J. L.;
Marini, A.;
Marszał, W.;
Martens, K.;
Martín, Y.;
Martinez, O.;
Martucci, M.;
Masciantonio, G.;
Mase, K.;
Mastafa, M.;
Matev, R.;
Matthews, J. N.;
Mebarki, N.;
Medina-Tanco, G.;
Mendoza, M. A.;
Menshikov, A.;
Merino, A.;
Meseguer, J.;
Meyer, S. S.;
Mimouni, J.;
Miyamoto, H.;
Mizumoto, Y.;
Monaco, A.;
Ríos, J. A. Morales de los;
Nagataki, C. Moretto S.;
Naitamor, S.;
Napolitano, T.;
Naslund, W.;
Nava, R.;
Neronov, A.;
Nomoto, K.;
Nonaka, T.;
Ogawa, T.;
Ogio, S.;
Ohmori, H.;
Olinto, A. V.;
Orleański, P.;
Osteria, G.;
Pagliaro, A.;
Painter, W.;
Panasyuk, M. I.;
Panico, B.;
Pasqualino, G.;
Parizot, E.;
Park, I. H.;
Pastircak, B.;
Patzak, T.;
Paul, T.;
Pérez-Grande, I.;
Perfetto, F.;
Peter, T.;
Picozza, P.;
Pindado, S.;
Piotrowski, L. W.;
Piraino, S.;
Placidi, L.;
Plebaniak, Z.;
Pliego, S.;
Pollini, A.;
Polonski, Z.;
Popescu, E. M.;
Prat, P.;
Prévôt, G.;
Prieto, H.;
Puehlhofer, G.;
Putis, M.;
Rabanal, J.;
Radu, A. A.;
Reyes, M.;
Rezazadeh, M.;
Ricci, M.;
Frías, M. D. Rodríguez;
Rodencal, M.;
Ronga, F.;
Roudil, G.;
Rusinov, I.;
Rybczyński, M.;
Sabau, M. D.;
Cano, G. Sáez;
Sagawa, H.;
Sahnoune, Z.;
Saito, A.;
Sakaki, N.;
Salazar, H.;
Balanzar, J. C. Sanchez;
Sánchez, J. L.;
Santangelo, A.;
Sanz-Andrés, A.;
Palomino, M. Sanz;
Saprykin, O.;
Sarazin, F.;
Sato, M.;
Schanz, T.;
Schieler, H.;
Scotti, V.;
Selmane, S.;
Semikoz, D.;
Serra, M.;
Sharakin, S.;
Shimizu, H. M.;
Shinozaki, K.;
Shirahama, T.;
Spataro, B.;
Stan, I.;
Sugiyama, T.;
Supanitsky, D.;
Suzuki, M.;
Szabelska, B.;
Szabelski, J.;
Tajima, N.;
Tajima, T.;
Takahashi, Y.;
Takami, H.;
Takeda, M.;
Takizawa, Y.;
Talai, M. C.;
Tenzer, C.;
Thomas, S. B.;
Tibolla, O.;
Tkachev, L.;
Tokuno, H.;
Tomida, T.;
Tone, N.;
Toscano, S.;
Traïche, M.;
Tsenov, R.;
Tsunesada, Y.;
Tsuno, K.;
Tubbs, J.;
Turriziani, S.;
Uchihori, Y.;
Vaduvescu, O.;
Valdés-Galicia, J. F.;
Vallania, P.;
Vankova, G.;
Vigorito, C.;
Villaseñor, L.;
Vlcek, B.;
von Ballmoos, P.;
Vrabel, M.;
Wada, S.;
Watanabe, J.;
Watts, J.;
Weber, M.;
Muñoz, R. Weigand;
Weindl, A.;
Wiencke, L.;
Wille, M.;
Wilms, J.;
Włodarczyk, Z.;
Yamamoto, T.;
Yang, J.;
Yano, H.;
Yashin, I. V.;
Yonetoku, D.;
Yoshida, S.;
Young, R.;
Zgura, I. S;
Zotov, M. Yu.;
Marchi, A. Zuccaro
Submitted: 2018-08-07
EUSO-Balloon is a pathfinder mission for the Extreme Universe Space
Observatory onboard the Japanese Experiment Module (JEM-EUSO). It was launched
on the moonless night of the 25$^{th}$ of August 2014 from Timmins, Canada. The
flight ended successfully after maintaining the target altitude of 38 km for
five hours. One part of the mission was a 2.5 hour underflight using a
helicopter equipped with three UV light sources (LED, xenon flasher and laser)
to perform an inflight calibration and examine the detectors capability to
measure tracks moving at the speed of light. We describe the helicopter laser
system and details of the underflight as well as how the laser tracks were
recorded and found in the data. These are the first recorded laser tracks
measured from a fluorescence detector looking down on the atmosphere. Finally,
we present a first reconstruction of the direction of the laser tracks relative
to the detector.
[5]
oai:arXiv.org:1204.6218 [pdf] - 1118329
Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for
Dark Matter Searches
Alexander, T.;
Alton, D.;
Arisaka, K.;
Back, H. O.;
Beltrame, P.;
Benziger, J.;
Bonfini, G.;
Brigatti, A.;
Brodsky, J.;
Cadonati, L.;
Calaprice, F.;
Candela, A.;
Cao, H.;
Cavalcante, P.;
Chavarria, A.;
Chepurnov, A.;
Cline, D.;
Cocco, A. G.;
Condon, C.;
D'Angelo, D.;
Davini, S.;
De Haas, E.;
Derbin, A.;
Di Pietro, G.;
Dratchnev, I.;
Durben, D.;
Empl, A.;
Etenko, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Gabriele, F.;
Galbiati, C.;
Gazzana, S.;
Ghag, C.;
Ghiano, C.;
Goretti, A.;
Grandi, L.;
Gromov, M.;
Guan, M.;
Guo, C.;
Guray, G.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Kayunov, A.;
Keeter, K.;
Kendziora, C.;
Kidner, S.;
Kobychev, V.;
Koh, G.;
Korablev, D.;
Korga, G.;
Shields, E.;
Li, P.;
Loer, B.;
Lombardi, P.;
Love, C.;
Ludhova, L.;
Lukyanchenko, L.;
Lund, A.;
Lung, K.;
Ma, Y.;
Machulin, I.;
Maricic, J.;
Martoff, C. J.;
Meng, Y.;
Meroni, E.;
Meyers, P. D.;
Mohayai, T.;
Montanari, D.;
Montuschi, M.;
Mosteiro, P.;
Mount, B.;
Muratova, V.;
Nelson, A.;
Nemtzow, A.;
Nurakhov, N.;
Orsini, M.;
Ortica, F.;
Pallavicini, M.;
Pantic, E.;
Parmeggiano, S.;
Parsells, R.;
Pelliccia, N.;
Perasso, L.;
Perfetto, F.;
Pinsky, L.;
Pocar, A.;
Pordes, S.;
Ranucci, G.;
Razeto, A.;
Romani, A.;
Rossi, N.;
Saggese, P.;
Saldanha, R.;
Salvo, C.;
Sands, W.;
Seigar, M.;
Semenov, D.;
Skorokhvatov, M.;
Smirnov, O.;
Sotnikov, A.;
Sukhotin, S.;
Suvorov, Y.;
Tartaglia, R.;
Tatarowicz, J.;
Testera, G.;
Teymourian, A.;
Thompson, J.;
Unzhakov, E.;
Vogelaar, R. B.;
Wang, H.;
Westerdale, S.;
Wojcik, M.;
Wright, A.;
Xu, J.;
Yang, C.;
Zavatarelli, S.;
Zehfus, M.;
Zhong, W.;
Zuzel, G.
Submitted: 2012-04-27, last modified: 2013-08-14
As part of the DarkSide program of direct dark matter searches using liquid
argon TPCs, a prototype detector with an active volume containing 10 kg of
liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso
National Laboratory in Italy. A critically important parameter for such devices
is the scintillation light yield, as photon statistics limits the rejection of
electron-recoil backgrounds by pulse shape discrimination. We have measured the
light yield of DarkSide-10 using the readily-identifiable full-absorption peaks
from gamma ray sources combined with single-photoelectron calibrations using
low-occupancy laser pulses. For gamma lines of energies in the range 122-1275
keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys)
p.e./keVee. With additional purification, the light yield measured at 511 keV
increased to 9.142+-0.006(stat) p.e./keVee.
[6]
oai:arXiv.org:1108.5584 [pdf] - 1083670
Demonstration and Comparison of Operation of Photomultiplier Tubes at
Liquid Argon Temperature
Acciarri, R.;
Antonello, M.;
Boffelli, F.;
Cambiaghi, M.;
Canci, N.;
Cavanna, F.;
Cocco, A. G.;
Deniskina, N.;
Di Pompeo, F.;
Fiorillo, G.;
Galbiati, C.;
Grandi, L.;
Kryczynski, P.;
Meng, G.;
Montanari, C.;
Palamara, O.;
Pandola, L.;
Perfetto, F.;
Mortari, G. B. Piano;
Pietropaolo, F.;
Raselli, G. L.;
Rossella, M.;
Rubbia, C.;
Segreto, E.;
Szelc, A. M.;
Triossi, A.;
Ventura, S.;
Vignoli, C.;
Zani, A.
Submitted: 2011-08-29, last modified: 2011-09-26
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments.