sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Perez, Kerstin M

Normalized to: Perez, K.

32 article(s) in total. 231 co-authors, from 1 to 25 common article(s). Median position in authors list is 8,0.

[1]  oai:arXiv.org:2006.13789  [pdf] - 2123677
Breakthrough Listen Search for Technosignatures Towards the Kepler-160 System
Comments:
Submitted: 2020-06-22
We have conducted a search for artificial radio emission associated with the Kepler-160 system following the report of the discovery of the Earth-like planet candidate KOI-456.04 on 2020 June 4 (arXiv:1905.09038v2). Our search targeted both narrowband (2.97 Hz) drifting ($\pm 4$ Hz s$^{-1})$ and wideband pulsed (5 ms at all bandwidths) artificially-dispersed technosignatures using the turboSETI (arXiv:1709.03491v2) and SPANDAK pipelines, respectively, from 1-8 GHz. No candidates were identified above an upper limit Equivalent Isotropic Radiated Power (EIRP) of $5.9 \times 10^{14}$ W for narrowband emission and $7.3 \times 10^{12}$ W for wideband emission. Here we briefly describe our observations and data reduction procedure.
[2]  oai:arXiv.org:1908.09037  [pdf] - 2091653
NuSTAR Tests of Sterile-Neutrino Dark Matter: New Galactic Bulge Observations and Combined Impact
Comments: 16 pages, 5 figures. Text updated to match published version in PRD. Conclusions unchanged
Submitted: 2019-08-23, last modified: 2020-05-08
We analyze two dedicated NuSTAR observations with exposure ${\sim}190$ ks located ${\sim}10^\circ$ from the Galactic plane, one above and the other below, to search for x-ray lines from the radiative decay of sterile-neutrino dark matter. These fields were chosen to minimize astrophysical x-ray backgrounds while remaining near the densest region of the dark matter halo. We find no evidence of anomalous x-ray lines in the energy range 5--20 keV, corresponding to sterile neutrino masses 10--40 keV. Interpreted in the context of sterile neutrinos produced via neutrino mixing, these observations provide the leading constraints in the mass range 10--12 keV, improving upon previous constraints in this range by a factor ${\sim}2$. We also compare our results to Monte Carlo simulations, showing that the fluctuations in our derived limit are not dominated by systematic effects. An updated model of the instrumental background, which is currently under development, will improve NuSTAR's sensitivity to anomalous x-ray lines, particularly for energies 3--5 keV.
[3]  oai:arXiv.org:2003.03453  [pdf] - 2060934
NuSTAR and Chandra Observation of the Galactic Center Non-thermal X-ray Filament G0.13-0.11: A Pulsar Wind Nebula Driven Magnetic Filament
Comments: 7 pages, 4 figures; Accepted by ApJ
Submitted: 2020-03-06
One of the most unique phenomena in the Galactic center region is the existence of numerous long and narrow filamentary structures within a few hundred parsecs of Sgr A$^{\star}$. While more than one than one hundred radio filaments have been revealed by MeerKAT, about two dozens X-ray filaments have been discovered so far. In this article, we report our analysis on the deep Chandra and NuSTAR observations of a non-thermal X-ray filament, G0.13-0.11, which is located adjacent to the Radio arc. Chandra revealed a unique morphology of G0.13-0.11, which is an elongated (0.1 pc in width and 3.2 pc in length) structure slightly bended towards the Radio arc. A pulsar candidate ($\Gamma \sim 1.4$) is detected in the middle of the filament, with a tail of diffuse non-thermal X-ray emission on one side of the filament. The filament is detected by NuSTAR up to 79 keV, with the hard X-ray centroid consistent with the pulsar candidate. We found that the X-ray intensity decays along the filament farther away from the pulsar candidate, dropping to half of its peak value at 2.2 pc away. This system is mostly likely a Pulsar Wind Nebula interacting with ambient interstellar magnetic field, where the filaments are kinetic jets from PWN as recently proposed. The nature of this filament adds to complex origin of the X-ray filaments, which serve as powerful tools to probe local and global powerful particle accelerators in the Galactic center.
[4]  oai:arXiv.org:2002.04163  [pdf] - 2046557
Cosmic-ray Antinuclei as Messengers of New Physics: Status and Outlook for the New Decade
Comments: 42 pages, 14 figures
Submitted: 2020-02-10
The precise measurement of cosmic-ray antinuclei serves as an important means for identifying the nature of dark matter and other new astrophysical phenomena, and could be used with other cosmic-ray species to understand cosmic-ray production and propagation in the Galaxy. For instance, low-energy antideuterons would provide a "smoking gun" signature of dark matter annihilation or decay, essentially free of astrophysical background. Studies in recent years have emphasized that models for cosmic-ray antideuterons must be considered together with the abundant cosmic antiprotons and any potential observation of antihelium. Therefore, a second dedicated Antideuteron Workshop was organized at UCLA in March 2019, bringing together a community of theorists and experimentalists to review the status of current observations of cosmic-ray antinuclei, the theoretical work towards understanding these signatures, and the potential of upcoming measurements to illuminate ongoing controversies. This review aims to synthesize this recent work and present implications for the upcoming decade of antinuclei observations and searches. This includes discussion of a possible dark matter signature in the AMS-02 antiproton spectrum, the most recent limits from BESS Polar-II on the cosmic antideuteron flux, and reports of candidate antihelium events by AMS-02; recent collider and cosmic-ray measurements relevant for antinuclei production models; the state of cosmic-ray transport models in light of AMS-02 and Voyager data; and the prospects for upcoming experiments, such as GAPS. This provides a roadmap for progress on cosmic antinuclei signatures of dark matter in the coming years.
[5]  oai:arXiv.org:1912.06571  [pdf] - 2014538
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking for the GAPS Experiment
Comments:
Submitted: 2019-12-13
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150{\deg}C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tracking capability for charged particles, while operating in conditions (~-40{\deg}C and ~1 Pa) achievable on a long-duration balloon mission with a large detector payload. These characteristics enable the GAPS silicon tracker system to identify cosmic antinuclei via a novel technique based on exotic atom formation, de-excitation, and annihilation. Production and large-scale calibration of ~1000 detectors has begun for the first GAPS flight, scheduled for late 2021. The detectors developed for GAPS may also have other applications, for example in heavy nuclei identification.
[6]  oai:arXiv.org:1906.00054  [pdf] - 1995412
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment
Comments: Accepted for publication at JINST, 16 pages, 8 figures
Submitted: 2019-05-31, last modified: 2019-11-08
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required $\lesssim$4 keV (FWHM) X-ray energy resolution at flight temperatures of $-35$ to $-45^{\circ}$C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
[7]  oai:arXiv.org:1909.05916  [pdf] - 1987449
The Galactic Bulge Diffuse Emission in Broad-Band X-rays with NuSTAR
Comments: 14 pages, 6 figures, submitted to Ap.J
Submitted: 2019-09-12
The diffuse hard X-ray emission that fills the Galactic center, bulge, and ridge is believed to arise from unresolved populations of X-ray binary systems. However, the identity of the dominant class of accreting objects in each region remains unclear. Recent studies of Fe line properties and the low-energy (<10 keV) X-ray continuum of the bulge indicate a major population fraction of non-magnetic cataclysmic variables (CVs), in particular quiescent dwarf novae. This is in contrast to previous high-energy (>10 keV) X-ray measurements of the bulge and ridge, which indicate a dominant population of magnetic CVs, in particular intermediate polars. In addition, NuSTAR broad-band measurements have uncovered a much heavier intermediate polar population in the central ~100 pc than previously assumed, raising the possibility that some fraction of this population extends further from the center. Here we use NuSTAR's large aperture for unfocused photons and its broad-band X-ray range to probe the diffuse continuum of the inner ~1-3$^\circ$ of the Galactic bulge. This allows us to constrain possible multi-temperature components of the spectrum, such as could indicate a mixture of soft and hard populations. Our emissivity is consistent with previous hard X-ray measurements in the bulge and ridge, with the diffuse X-ray luminosity tracing the stellar mass. The spectrum is well-described by a single-temperature thermal plasma with $kT \approx 8$ keV, with no significant emission above 20 keV. This supports that the bulge is dominated by quiescent dwarf novae; we find no evidence of a significant intermediate polar population in the hard X-ray band.
[8]  oai:arXiv.org:1909.03090  [pdf] - 1957375
SmallSat Solar Axion and Activity X-ray Imager (SSAXI)
Comments: 12 pages, 9 figures, 1 table, Presented at the SPIE Optics + Photonics Conference, August 2019, San Diego, CA
Submitted: 2019-09-06
Axions are a promising dark matter candidate as well as a solution to the strong charge-parity (CP) problem in quantum chromodynamics (QCD). We describe a new mission concept for SmallSat Solar Axion and Activity X-ray Imager (SSAXI) to search for solar axions or axion-like particles (ALPs) and to monitor solar activity of the entire solar disc over a wide dynamic range. SSAXI aims to unambiguously identify X-rays converted from axions in the solar magnetic field along the line of sight to the solar core, effectively imaging the solar core. SSAXI also plans to establish a statistical database of X-ray activities from Active Regions, microflares, and Quiet Sun regions to understand the origin of the solar corona heating processes. SSAXI employs Miniature lightweight Wolter-I focusing X-ray optics (MiXO) and monolithic CMOS X-ray sensors in a compact package. The wide energy range (0.5 - 6 keV) of SSAXI can easily distinguish spectra of axion-converted X-rays from typical X-ray spectra of solar activities, while encompassing the prime energy band (3 - 4.5 keV) of axion-converted X-rays. The high angular resolution (30 arcsec HPD) and large field of view (40 arcmin) in SSAXI will easily resolve the enhanced X-ray flux over the 3 arcmin wide solar core while fully covering the X-ray activity over the entire solar disc. The fast readout in the inherently radiation tolerant CMOS X-ray sensors enables high resolution spectroscopy with a wide dynamic range in a broad range of operational temperatures. SSAXI will operate in a Sun-synchronous orbit for 1 yr preferably near a solar minimum to accumulate sufficient X-ray photon statistics.
[9]  oai:arXiv.org:1906.05577  [pdf] - 1983873
Developing a mass-production model of large-area Si(Li) detectors with high operating temperatures
Comments: 28 pages, 11 figures, submitted in 6/13/2019; re-submitted in 8/23/2019;
Submitted: 2019-06-13, last modified: 2019-08-27
This study presents a fabrication process for lithium-drifted silicon (Si(Li)) detectors that, compared to previous methods, allows for mass production at a higher yield, while providing a large sensitive area and low leakage currents at relatively high temperatures. This design, developed for the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment, has an overall diameter of 10 cm, with ~9 cm of active area segmented into 8 readout strips, and an overall thickness of 2.5 mm, with $\gtrsim$2.2 mm ($\gtrsim$90%) sensitive thickness. An energy resolution $\lesssim$4 keV full-width at half-maximum (FWHM) for 20-100 keV X-rays is required at the operating temperature ~-40C, which is far above the liquid nitrogen temperatures conventionally used to achieve fine energy resolution. High-yield production is also required for GAPS, which consists of $\gtrsim$1000 detectors. Our specially-developed Si crystal and custom methods of Li evaporation, diffusion and drifting allow for a thick, large-area and uniform sensitive layer. We find that retaining a thin undrifted layer on the p-side of the detector drastically reduces the leakage current, which is a dominant component of the energy resolution at these temperatures. A guard-ring structure and optimal etching of the detector surface are also confirmed to suppress the leakage current. We report on the mass production of these detectors that is ongoing now, and demonstrate it is capable of delivering a high yield of ~90%.
[10]  oai:arXiv.org:1908.03154  [pdf] - 1931578
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Comments: 8 pages, 7 figures, Proc. 36th International Cosmic Ray Conference (ICRC 2019), Madison, USA
Submitted: 2019-08-08
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significantly below those predicted by well-motivated, beyond the standard model theories. GAPS will also conduct low-energy antiproton and antihelium searches. Combined, these observations will provide a powerful search for dark matter and provide the best observations to date on primordial black hole evaporation on Galactic length scales. The GAPS instrument detects antinuclei using the novel exotic atom technique. It consists of a central tracker with a surrounding time-of-flight (TOF) system. The tracker is a one cubic meter volume containing 10 cm-diameter lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator system that will both trigger the Si(Li) tracker and enable better reconstruction of particle tracks. After coming to rest in the tracker, antinuclei will form an excited exotic atom. This will then de-excite via characteristic X-ray transitions before producing a pion/proton star when the antiparticle annihilates with the nucleus. This unique event topology will give GAPS the nearly background-free detection capability required for a rare-event search. Here we present the scientific motivation for the GAPS experiment, its design and its current status as it prepares for flight in the austral summer of 2021-22.
[11]  oai:arXiv.org:1901.01262  [pdf] - 1871470
New Constraints on Sterile Neutrino Dark Matter from $NuSTAR$ M31 Observations
Comments: 16 pages, 6 figures. References added, minor edits, conclusions unchanged. Accepted in PRD
Submitted: 2019-01-04, last modified: 2019-04-22
We use a combined 1.2 Ms of $NuSTAR$ observations of M31 to search for X-ray lines from sterile neutrino dark matter decay. For the first time in a $NuSTAR$ analysis, we consistently take into account the signal contribution from both the focused and unfocused fields of view. We also reduce the modeling systematic uncertainty by performing spectral fits to each observation individually and statistically combining the results, instead of stacking the spectra. We find no evidence of unknown lines, and thus derive limits on the sterile neutrino parameters. Our results place stringent constraints for dark matter masses $\gtrsim 12$ keV, which reduces the available parameter space for sterile neutrino dark matter produced via neutrino mixing ($e.g.$, in the $\nu$MSM) by approximately one-third. Additional $NuSTAR$ observations, together with improved low-energy background modeling, could probe the remaining parameter space in the future. Lastly, we also report model-independent limits on generic dark matter decay rates and annihilation cross sections.
[12]  oai:arXiv.org:1904.05938  [pdf] - 1866492
Astro 2020 Science White Paper: Cosmic-ray Antinuclei as Messengers for Dark Matter
Comments: 12 pages, 2 figures, Science White Paper submitted to the Astro2020 Decadal Survey
Submitted: 2019-04-11
The origin of dark matter is a driving question of modern physics. Low-energy antideuterons provide a "smoking gun" signature of dark matter annihilation or decay, essentially free of astrophysical background. Low-energy antiprotons are a vital partner for this analysis, and low-energy antihelium could provide further discovery space for new physics. In the coming decade, AMS-02 will continue accumulating the large statistics and systematic understanding necessary for it to probe rare antinuclei signatures, and GAPS, which is the first experiment optimized specifically for low-energy cosmic antinuclei, will begin several Antarctic balloon campaigns. The connection of cosmic-ray antinuclei and dark matter is reviewed and the outlook in light of experimental progress is presented.
[13]  oai:arXiv.org:1812.07255  [pdf] - 1800114
Development of Large-area Lithium-drifted Silicon Detectors for the GAPS Experiment
Comments: submitted to IEEE NSS/MIC 2018 Proceedings
Submitted: 2018-12-18
We have developed large-area lithium-drifted silicon (Si(Li)) detectors to meet the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment. GAPS is an Antarctic balloon-borne mission scheduled for the first flight in late 2020. The GAPS experiment aims to survey low-energy cosmic-ray antinuclei, particularly antideuterons, which are recognized as essentially background-free signals from dark matter annihilation or decay. The GAPS Si(Li) detector design is a thickness of 2.5 mm, diameter of 10 cm and 8 readout strips. The energy resolution of <4 keV (FWHM) for 20 to 100 keV X-rays at temperature of -35 to -45 C, far above the liquid nitrogen temperatures frequently used to achieve fine energy resolution, is required. We developed a high-quality Si crystal and Li-evaporation, diffusion and drift methods to form a uniform Li-drifted layer. Guard ring structure and optimal etching of the surface are confirmed to suppress the leakage current, which is a main source of noise. We found a thin un-drifted layer retained on the p-side effectively suppresses the leakage current. By these developments, we succeeded in developing the GAPS Si(Li) detector. As the ultimate GAPS instrument will require >1000 10-cm diameter Si(Li) detectors to achieve high sensitivity to rare antideuteron events, high-yield production is also a key factor for the success of the GAPS mission.
[14]  oai:arXiv.org:1809.09714  [pdf] - 1757324
GAPS: A New Cosmic Ray Anti-matter Experiment
Comments: Talk presented CIPANP2018. 13 pages, LaTeX, 7 figures. Higher resolution figs at http://gaps1.astro.ucla.edu/gaps/papers2018/cipanp18
Submitted: 2018-09-25
The General AntiParticle Spectrometer (GAPS) is a balloon-borne instrument designed to detect cosmic-ray antimatter using the novel exotic atom technique, obviating the strong magnetic fields required by experiments like AMS, PAMELA, or BESS. It will be sensitive to primary antideuterons with kinetic energies of $\approx0.05-0.2$ GeV/nucleon, providing some overlap with the previously mentioned experiments at the highest energies. For $3\times35$ day balloon flights, and standard classes of primary antideuteron propagation models, GAPS will be sensitive to $m_{\mathrm{DM}}\approx10-100$ GeV c$^{-2}$ WIMPs with a dark-matter flux to astrophysical flux ratio approaching 100. This clean primary channel is a key feature of GAPS and is crucial for a rare event search. Additionally, the antiproton spectrum will be extended with high statistics measurements to cover the $0.07 \leq E \leq 0.25 $ GeV domain. For $E>0.2$ GeV GAPS data will be complementary to existing experiments, while $E<0.2$ GeV explores a new regime. The first flight is scheduled for late 2020 in Antarctica. These proceedings will describe the astrophysical processes and backgrounds relevant to the dark matter search, a brief discussion of detector operation, and construction progress made to date.
[15]  oai:arXiv.org:1807.07912  [pdf] - 1719637
Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment
Comments: Accepted for publication at Nuclear Instrumentation and Methods A, 12 pages, 11 figures
Submitted: 2018-07-20
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1-1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of $\sim$4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. This fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.
[16]  oai:arXiv.org:1807.04315  [pdf] - 1714869
MagAO-X: project status and first laboratory results
Comments: Presented at SPIE Astronomical Telescopes and Instrumentation 2018
Submitted: 2018-07-11
MagAO-X is an entirely new "extreme" adaptive optics system for the Magellan Clay 6.5 m telescope, funded by the NSF MRI program starting in Sep 2016. The key science goal of MagAO-X is high-contrast imaging of accreting protoplanets at H$\alpha$. With 2040 actuators operating at up to 3630 Hz, MagAO-X will deliver high Strehls (>70%), high resolution (19 mas), and high contrast ($< 1\times10^{-4}$) at H$\alpha$ (656 nm). We present an overview of the MagAO-X system, review the system design, and discuss the current project status.
[17]  oai:arXiv.org:1805.08870  [pdf] - 1698230
NuSTAR Detection of a Hard X-ray Source in the Supernova Remnant - Molecular Cloud Interaction Site of IC 443
Comments: 10 pages, 6 figures. Accepted by ApJ
Submitted: 2018-05-22
We report on a broadband study of a complex X-ray source (1SAX J0618.0+2227) associated with the interaction site of the supernova remnant (SNR) IC 443 and ambient molecular cloud (MC) using NuSTAR, XMM_Newton, and Chandra observations. Its X-ray spectrum is composed of both thermal and non-thermal components. The thermal component can be equally well represented by either a thin plasma model with kT=0.19 keV or a blackbody model with kT=0.11 keV. The non-thermal component can be fit with either a power-law with Gamma~1.7 or a cutoff power-law with Gamma~1.5 and a cutoff energy at E_cut~18 keV. Using the newly obtained NuSTAR dataset, we test three possible scenarios for isolated X-ray sources in the SNR-MC interaction site: 1) pulsar wind nebula (PWN); 2) SNR ejecta fragment; 3) shocked molecular clump. We conclude that this source is most likely composed of a SNR ejecta (or a PWN) and surrounding shocked molecular clumps. The nature of this hard X-ray source in the SNR-MC interaction site of IC 443 may shed light on unidentified X-ray sources with hard X-ray spectra in rich environments for star forming regions, such as the Galactic center.
[18]  oai:arXiv.org:1710.00452  [pdf] - 1589126
The GAPS Experiment to Search for Dark Matter using Low-energy Antimatter
Comments: 8 pags, 3 figures, Proc. 35th International Cosmic Ray Conference (ICRC 2017), Busan, Korea
Submitted: 2017-10-01
The GAPS experiment is designed to carry out a sensitive dark matter search by measuring low-energy cosmic ray antideuterons and antiprotons. GAPS will provide a new avenue to access a wide range of dark matter models and masses that is complementary to direct detection techniques, collider experiments and other indirect detection techniques. Well-motivated theories beyond the Standard Model contain viable dark matter candidates which could lead to a detectable signal of antideuterons resulting from the annihilation or decay of dark matter particles. The dark matter contribution to the antideuteron flux is believed to be especially large at low energies (E < 1 GeV), where the predicted flux from conventional astrophysical sources (i.e. from secondary interactions of cosmic rays) is very low. The GAPS low-energy antiproton search will provide stringent constraints on less than 10 GeV dark matter, will provide the best limits on primordial black hole evaporation on Galactic length scales, and will explore new discovery space in cosmic ray physics. Unlike other antimatter search experiments such as BESS and AMS that use magnetic spectrometers, GAPS detects antideuterons and antiprotons using an exotic atom technique. This technique, and its unique event topology, will give GAPS a nearly background-free detection capability that is critical in a rare-event search. GAPS is designed to carry out its science program using long-duration balloon flights in Antarctica. A prototype instrument was successfully flown from Taiki, Japan in 2012. GAPS has now been approved by NASA to proceed towards the full science instrument, with the possibility of a first long-duration balloon flight in late 2020. Here we motivate low-energy cosmic ray antimatter searches and discuss the current status of the GAPS experiment and the design of the payload.
[19]  oai:arXiv.org:1609.00667  [pdf] - 1580200
(Almost) Closing the $\nu$MSM Sterile Neutrino Dark Matter Window with NuSTAR
Comments: 10 pages, 8 figures
Submitted: 2016-09-02, last modified: 2016-12-05
We use NuSTAR observations of the Galactic Center to search for X-ray lines from the radiative decay of sterile neutrino dark matter. Finding no evidence of unknown lines, we set limits on the sterile neutrino mass and mixing angle. In most of the mass range 10-50 keV, these are now the strongest limits, at some masses improving upon previous limits by a factor of ~10. In the neutrino minimal standard model framework, where additional constraints from dark matter production and structure formation apply, the allowed parameter space is reduced by more than half. Future NuSTAR observations may be able to cover much of the remaining parameter space.
[20]  oai:arXiv.org:1605.06066  [pdf] - 1457309
Evidence for intermediate polars as the origin of the Galactic Center hard X-ray emission
Comments: 17 pages, accepted for publication in Astrophysical Journal
Submitted: 2016-05-19
Recently, unresolved hard (20-40 keV) X-ray emission has been discovered within the central 10 pc of the Galaxy, possibly indicating a large population of intermediate polars (IPs). Chandra and XMM-Newton measurements in the surrounding ~50 pc imply a much lighter population of IPs with $\langle M_{\rm WD} \rangle \approx 0.5 M_\odot$. Here we use broad-band NuSTAR observations of two IPs: TV Columbae, which has a fairly typical but widely varying reported mass of $M_{\rm WD} \approx 0.5-1.0 M_\odot$, and IGR J17303-0601, with a heavy reported mass of $M_{\rm WD} \approx 1.0-1.2 M_\odot$. We investigate how varying spectral models and observed energy ranges influence estimated white dwarf mass. Observations of the inner 10 pc can be accounted for by IPs with $\langle M_{\rm WD} \rangle \approx 0.9 M_\odot$, consistent with that of the CV population in general, and the X-ray observed field IPs in particular. The lower mass derived by Chandra and XMM-Newton appears to be an artifact of narrow energy band fitting. To explain the (unresolved) CHXE by IPs requires an X-ray (2-8 keV) luminosity function (XLF) extending down to at least $5\times10^{31}$ erg/s. The CHXE XLF, if extended to the surrounding ~50 pc observed by Chandra and XMM-Newton, requires at least ~20-40% of the $\sim$9000 point sources are IPs. If the XLF extends just a factor of a few lower in luminosity, then the vast majority of these sources are IPs. This is in contrast to recent observations of the Galactic ridge, where the bulk of the 2-8 keV emission is ascribed to dwarf novae.
[21]  oai:arXiv.org:1605.03882  [pdf] - 1439854
NuSTAR Hard X-ray Survey of the Galactic Center Region II: X-ray Point Sources
Comments: 32 pages, 15 figures, 7 tables, accepted for publication in ApJ
Submitted: 2016-05-12
We present the first survey results of hard X-ray point sources in the Galactic Center (GC) region by NuSTAR. We have discovered 70 hard (3-79 keV) X-ray point sources in a 0.6 deg^2 region around Sgr A* with a total exposure of 1.7 Ms, and 7 sources in the Sgr B2 field with 300 ks. We identify clear Chandra counterparts for 58 NuSTAR sources and assign candidate counterparts for the remaining 19. The NuSTAR survey reaches X-ray luminosities of ~4 x and ~8 x 10^32 erg s^-1 at the GC (8 kpc) in the 3-10 and 10-40 keV bands, respectively. The source list includes three persistent luminous X-ray binaries and the likely run-away pulsar called the Cannonball. New source-detection significance maps reveal a cluster of hard (>10 keV) X-ray sources near the Sgr A diffuse complex with no clear soft X-ray counterparts. The severe extinction observed in the Chandra spectra indicates that all the NuSTAR sources are in the central bulge or are of extragalactic origin. Spectral analysis of relatively bright NuSTAR sources suggests that magnetic cataclysmic variables constitute a large fraction (>40-60%). Both spectral analysis and logN-logS distributions of the NuSTAR sources indicate that the X-ray spectra of the NuSTAR sources should have kT > 20 keV on average for a single temperature thermal plasma model or an average photon index of Gamma = 1.5 - 2 for a power-law model. These findings suggest that the GC X-ray source population may contain a larger fraction of X-ray binaries with high plasma temperatures than the field population.
[22]  oai:arXiv.org:1505.07785  [pdf] - 1384606
Review of the theoretical and experimental status of dark matter identification with cosmic-ray antideuterons
Comments: 72 pages, 20 figures
Submitted: 2015-05-28, last modified: 2016-04-04
Recent years have seen increased theoretical and experimental effort towards the first-ever detection of cosmic-ray antideuterons, in particular as an indirect signature of dark matter annihilation or decay. In contrast to indirect dark matter searches using positrons, antiprotons, or gamma-rays, which suffer from relatively high and uncertain astrophysical backgrounds, searches with antideuterons benefit from very suppressed conventional backgrounds, offering a potential breakthrough in unexplored phase space for dark matter. This article is based on the first dedicated cosmic-ray antideuteron workshop, which was held at UCLA in June 2014. It reviews broad classes of dark matter candidates that result in detectable cosmic-ray antideuteron fluxes, as well as the status and prospects of current experimental searches. The coalescence model of antideuteron production and the influence of antideuteron measurements at particle colliders are discussed. This is followed by a review of the modeling of antideuteron propagation through the magnetic fields, plasma currents, and molecular material of our Galaxy, the solar system, the Earth's geomagnetic field, and the atmosphere. Finally, the three ongoing or planned experiments that are sensitive to cosmic-ray antideuterons, BESS, AMS-02, and GAPS, are detailed. As cosmic-ray antideuteron detection is a rare event search, multiple experiments with orthogonal techniques and backgrounds are essential. Many theoretical and experimental groups have contributed to these studies over the last decade, this review aims to provide the first coherent discussion of the relevant dark matter theories that antideuterons probe, the challenges to predictions and interpretations of antideuteron signals, and the experimental efforts toward cosmic antideuteron detection.
[23]  oai:arXiv.org:1510.04631  [pdf] - 1294164
NuSTAR Hard X-ray Survey of the Galactic Center Region I: Hard X-ray Morphology and Spectroscopy of the Diffuse Emission
Comments: 27 pages. Accepted for publication in the Astrophysical Journal
Submitted: 2015-10-15
We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources and a previously unknown central component of hard X-ray emission (CHXE). NuSTAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with $\Gamma\sim1.3$-$2.3$ up to ~50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe K$\alpha$ fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broad-band X-ray spectral analysis with a Monte-Carlo based X-ray reflection model self-consistently determined their intrinsic column density ($\sim10^{23}$ cm$^{-2}$), primary X-ray spectra (power-laws with $\Gamma\sim2$) and set a lower limit of the X-ray luminosity of Sgr A* flare illuminating the Sgr A clouds to $L_X \stackrel{>}{\sim} 10^{38}$ erg s$^{-1}$. Above ~20 keV, hard X-ray emission in the central 10 pc region around Sgr A* consists of the candidate PWN G359.95-0.04 and the CHXE, possibly resulting from an unresolved population of massive CVs with white dwarf masses $M_{\rm WD} \sim 0.9 M_{\odot}$. Spectral energy distribution analysis suggests that G359.95-0.04 is likely the hard X-ray counterpart of the ultra-high gamma-ray source HESS J1745-290, strongly favoring a leptonic origin of the GC TeV emission.
[24]  oai:arXiv.org:1507.02717  [pdf] - 1262195
GAPS - Dark matter search with low-energy cosmic-ray antideuterons and antiprotons
Comments: 8 pages, 2 figures, ICRC 2015 proceedings
Submitted: 2015-07-09, last modified: 2015-08-13
The GAPS experiment is foreseen to carry out a dark matter search by measuring low-energy cosmic-ray antideuterons and antiprotons with a novel detection approach. It will provide a new avenue to access a wide range of different dark matter models and masses from about 10GeV to 1TeV. The theoretically predicted antideuteron flux resulting from secondary interactions of primary cosmic rays is very low. Well-motivated theories beyond the Standard Model contain viable dark matter candidates, which could lead to a significant enhancement of the antideuteron flux due to annihilation or decay of dark matter particles. This flux contribution is believed to be especially large at low energies, which leads to a high discovery potential for GAPS. The GAPS low-energy antiproton search will provide some of the most stringent constraints on ~30GeV dark matter, will provide the best limits on primordial black hole evaporation on galactic length scales, and explore new discovery space in cosmic-ray physics. GAPS is designed to achieve its goals via long duration balloon flights at high altitude in Antarctica. The detector itself will consist of 10 planes of Si(Li) solid state detectors and a surrounding time-of-flight system. Antideuterons and antiprotons will be slowed down in the Si(Li) material, replace a shell electron and form an excited exotic atom. The atom will be deexcited by characteristic X-ray transitions and will end its life by the formation of an annihilation pion/proton star. This unique event structure will deliver a nearly background free detection possibility.
[25]  oai:arXiv.org:1506.02513  [pdf] - 1288390
Antideuteron Sensitivity for the GAPS Experiment
Comments: 10 pages, 10 figures
Submitted: 2015-06-08, last modified: 2015-08-12
The General Antiparticle Spectrometer (GAPS) is a novel approach for indirect dark matter searches that exploits cosmic antiparticles, especially antideuterons. The GAPS antideuteron measurement utilizes distinctive detection methods using atomic X-rays and charged particles from the decay of exotic atoms as well as the timing and stopping range of the incoming particle, which together provide excellent antideuteron identification. Prior to the future balloon experiment, an accelerator test and a prototype flight were successfully conducted in 2005 and 2012 respectively, in order to verify the GAPS detection concept. This paper describes how the sensitivity of GAPS to antideuterons was estimated using a Monte Carlo simulation along with the atomic cascade model and the Intra-Nuclear Cascade model. The sensitivity for the GAPS antideuteron search obtained using this method is 2.0 $\times 10^{-6}$ [m$^{-2}$s$^{-1}$sr$^{-1}$(GeV/$n$)$^{-1}$] for the proposed long duration balloon program (LDB, 35 days $\times$ 3 flights), indicating that GAPS has a strong potential to probe a wide variety of dark matter annihilation and decay models through antideuteron measurements. GAPS is proposed to fly from Antarctica in the austral summer of 2019-2020.
[26]  oai:arXiv.org:1507.02712  [pdf] - 1244333
Status of cosmic-ray antideuteron searches
Comments: 9 pages, 4 figures, ICRC 2015 proceedings
Submitted: 2015-07-09
The precise measurement of cosmic-ray antiparticles serves as important means for identifying the nature of dark matter. Recent years showed that identifying the nature of dark matter with cosmic-ray positrons and higher energy antiprotons is difficult, and has lead to a significantly increased interest in cosmic-ray antideuteron searches. Antideuterons may also be generated in dark matter annihilations or decays, offering a potential breakthrough in unexplored phase space for dark matter. Low-energy antideuterons are an important approach because the flux from dark matter interactions exceeds the background flux by more than two orders of magnitude in the low-energy range for a wide variety of models. This review is based on the "dbar14 - dedicated cosmic-ray antideuteron workshop", which brought together theorists and experimentalists in the field to discuss the current status, perspectives, and challenges for cosmic-ray antideuteron searches and discusses the motivation for antideuteron searches, the theoretical and experimental uncertainties of antideuteron production and propagation in our Galaxy, as well as give an experimental cosmic-ray antideuteron search status update. This report is a condensed summary of the article "Review of the theoretical and experimental status of dark matter identification with cosmic-ray antideuteron" (arXiv:1505.07785).
[27]  oai:arXiv.org:1405.3239  [pdf] - 1209511
NuSTAR study of Hard X-Ray Morphology and Spectroscopy of PWN G21.5-0.9
Comments: 13 pages, 8 figures, 1 table, Accepted for publication in the Astrophysical Journal
Submitted: 2014-05-13
We present NuSTAR high energy X-ray observations of the pulsar wind nebula (PWN)/supernova remnant G21.5-0.9. We detect integrated emission from the nebula up to ~40 keV, and resolve individual spatial features over a broad X-ray band for the first time. The morphology seen by NuSTAR agrees well with that seen by XMM-Newton and Chandra below 10 keV. At high energies NuSTAR clearly detects non-thermal emission up to ~20 keV that extends along the eastern and northern rim of the supernova shell. The broadband images clearly demonstrate that X-ray emission from the North Spur and Eastern Limb results predominantly from non-thermal processes. We detect a break in the spatially integrated X-ray spectrum at ~9 keV that cannot be reproduced by current SED models, implying either a more complex electron injection spectrum or an additional process such as diffusion compared to what has been considered in previous work. We use spatially resolved maps to derive an energy-dependent cooling length scale, $L(E) \propto E^{m}$ with $m = -0.21 \pm 0.01$. We find this to be inconsistent with the model for the morphological evolution with energy described by Kennel & Coroniti (1984). This value, along with the observed steepening in power-law index between radio and X-ray, can be quantitatively explained as an energy-loss spectral break in the simple scaling model of Reynolds (2009), assuming particle advection dominates over diffusion. This interpretation requires a substantial departure from spherical magnetohydrodynamic (MHD), magnetic-flux-conserving outflow, most plausibly in the form of turbulent magnetic-field amplification.
[28]  oai:arXiv.org:1401.8245  [pdf] - 832848
Potential for Precision Measurement of Low-Energy Antiprotons with GAPS for Dark Matter and Primordial Black Hole Physics
Comments: 7 pages, 6 figures
Submitted: 2014-01-31, last modified: 2014-04-02
The general antiparticle spectrometer (GAPS) experiment is a proposed indirect dark matter search focusing on antiparticles produced by WIMP (weakly interacting massive particle) annihilation and decay in the Galactic halo. In addition to the very powerful search channel provided by antideuterons, GAPS has a strong capability to measure low-energy antiprotons (0.07 $\le$ E $\le$ 0.25 GeV) as dark matter signatures. This is an especially effective means for probing light dark matter, whose existence has been hinted at in the direct dark matter searches, including the recent result from the CDMS-II experiment. While severely constrained by LUX and other direct dark matter searches, light dark matter candidates are still viable in an isospin-violating dark matter scenario and halo-independent analysis. Along with the excellent antideuteron sensitivity, GAPS will be able to detect an order of magnitude more low-energy antiprotons, compared to BESS, PAMELA and AMS-02, providing a precision measurement of low-energy antiproton flux and a unique channel for probing light dark matter models. Additionally, dark matter signatures from gravitinos and Kaluza-Klein right-handed neutrinos as well as evidence of primordial black hole evaporation can be observed through low-energy antiproton search.
[29]  oai:arXiv.org:1307.3538  [pdf] - 770259
The flight of the GAPS prototype experiment
Comments: accepted for publication by Astroparticle Physics: 33 pages, 36 figures
Submitted: 2013-07-12, last modified: 2013-12-04
The General AntiParticle Spectrometer experiment (GAPS) is foreseen to carry out a dark matter search using low-energy cosmic ray antideuterons at stratospheric altitudes with a novel detection approach. A prototype flight from Taiki, Japan was carried out in June 2012 to prove the performance of the GAPS instrument subsystems (Lithium-drifted Silicon tracker and time-of-flight) and the thermal cooling concept as well as to measure background levels. The flight was a success and the stable flight operation of the GAPS detector concept was proven. During the flight about $10^6$ charged particle triggers were recorded, extensive X-ray calibrations of the individual tracker modules were performed by using an onboard X-ray tube, and the background level of atmospheric and cosmic X-rays was measured. The behavior of the tracker performance as a function of temperature was investigated. The tracks of charged particle events were reconstructed and used to study the tracking resolution, the detection efficiency of the tracker, and coherent X-ray backgrounds. A timing calibration of the time-of-flight subsystem was performed to measure the particle velocity. The flux as a function of flight altitude and as a function of velocity was extracted taking into account systematic instrumental effects. The developed analysis techniques will form the basis for future flights.
[30]  oai:arXiv.org:1311.1832  [pdf] - 1180580
High-Energy X-rays from J174545.5-285829, the Cannonball: A Candidate Pulsar Wind Nebula Associated with Sgr A East
Comments: 6 pages, 3 figures, 2 tables, Accepted for publication in The Astrophysical Journal Letters
Submitted: 2013-11-07, last modified: 2013-11-13
We report the unambiguous detection of non-thermal X-ray emission up to 30 keV from the Cannonball, a few-arcsecond long diffuse X-ray feature near the Galactic Center, using the NuSTAR X-ray observatory. The Cannonball is a high-velocity (vproj~500 km/s) pulsar candidate with a cometary pulsar wind nebula (PWN) located ~2' north-east from Sgr A*, just outside the radio shell of the supernova remnant Sagittarius A (Sgr A) East. Its non-thermal X-ray spectrum, measured up to 30 keV, is well characterized by a Gamma~1.6 power-law, typical of a PWN, and has an X-ray luminosity of L(3-30 keV)=1.3e34 erg/s. The spectral and spatial results derived from X-ray and radio data strongly suggest a runaway neutron star born in the Sgr A East supernova event. We do not find any pulsed signal from the Cannonball. The NuSTAR observations allow us to deduce the PWN magnetic field and show that it is consistent with the lower limit obtained from radio observations.
[31]  oai:arXiv.org:1303.0380  [pdf] - 1164967
The pGAPS experiment: an engineering balloon flight of prototype GAPS
Comments: submitted to (30/Dec/2012) and accepted by (21/Jun/2013) Advances in Space Research
Submitted: 2013-03-02, last modified: 2013-06-24
The General Anti-Particle Spectrometer (GAPS) project is being carried out to search for primary cosmic-ray antiparticles especially for antideuterons produced by cold dark matter. GAPS plans to realize the science observation by Antarctic long duration balloon flights in the late 2010s. In preparation for the Antarctic science flights, an engineering balloon flight using a prototype of the GAPS instrument, "pGAPS", was successfully carried out in June 2012 in Japan to verify the basic performance of each GAPS subsystem. The outline of the pGAPS flight campaign is briefly reported.
[32]  oai:arXiv.org:1303.1615  [pdf] - 1165080
The Prototype GAPS (pGAPS) Experiment
Comments: 37 pages, 25 figures
Submitted: 2013-03-07
The General Antiparticle Spectrometer (GAPS) experiment is a novel approach for the detection of cosmic ray antiparticles. A prototype GAPS experiment (pGAPS) was successfully flown on a high-altitude balloon in June of 2012. The goals of the pGAPS experiment were: to test the operation of lithium drifted silicon (Si(Li)) detectors at balloon altitudes, to validate the thermal model and cooling concept needed for engineering of a full-size GAPS instrument, and to characterize cosmic ray and X-ray backgrounds. The instrument was launched from the Japan Aerospace Exploration Agency's (JAXA) Taiki Aerospace Research Field in Hokkaido, Japan. The flight lasted a total of 6 hours, with over 3 hours at float altitude (~33 km). Over one million cosmic ray triggers were recorded and all flight goals were met or exceeded.