Normalized to: Pereverzev, S.
[1]
oai:arXiv.org:1910.07450 [pdf] - 1981331
Proceedings of The Magnificent CE$\nu$NS Workshop 2018
Sierra, D. Aristizabal;
Balantekin, A. B.;
Caratelli, D.;
Cogswell, B.;
Collar, J. I.;
Dahl, C. E.;
Dent, J.;
Dutta, B.;
Engel, J.;
Estrada, J.;
Formaggio, J.;
Gariazzo, S.;
Han, R.;
Hedges, S.;
Huber, P.;
Konovalov, A.;
Lang, R. F.;
Liao, S.;
Lindner, M.;
Machado, P.;
Mahapatra, R.;
Marfatia, D.;
Martinez-Soler, I.;
Miranda, O.;
Misiak, D.;
Naumov, D. V.;
Newby, J.;
Newstead, J.;
Papoulias, D.;
Patton, K.;
Pereverzev, S.;
Pospelov, M.;
Scholberg, K.;
Sinev, G.;
Strauss, R.;
Strigari, L.;
Tayloe, R.;
Tiffenberg, J.;
Vidal, M.;
Vignati, M.;
Wagner, V.;
Walker, J.;
Yu, T. -T.;
Zettlemoyer, J.;
Rich, G. C.
Submitted: 2019-10-16
The Magnificent CE$\nu$NS Workshop (2018) was held November 2 & 3 of 2018 on
the University of Chicago campus and brought together theorists,
phenomenologists, and experimentalists working in numerous areas but sharing a
common interest in the process of coherent elastic neutrino-nucleus scattering
(CE$\nu$NS). This is a collection of abstract-like summaries of the talks given
at the meeting, including links to the slides presented. This document and the
slides from the meeting provide an overview of the field and a snapshot of the
robust CE$\nu$NS-related efforts both planned and underway.
[2]
oai:arXiv.org:1402.2037 [pdf] - 817676
First measurement of the ionization yield of nuclear recoils in liquid
argon
Joshi, T. H.;
Sangiorgio, S.;
Bernstein, A.;
Foxe, M.;
Hagmann, C.;
Jovanovic, I.;
Kazkaz, K.;
Mozin, V.;
Norman, E. B.;
Pereverzev, S. V.;
Rebassoo, F.;
Sorensen, P.
Submitted: 2014-02-10, last modified: 2014-05-01
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV
$^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3
detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130
V/cm, is encouraging for the use of this detector medium to search for the
signals from hypothetical dark matter particle interactions and from coherent
elastic neutrino nucleus scattering. A significant dependence of $Q_y$ on the
applied electric field is observed and explained in the context of ion
recombination.
[3]
oai:arXiv.org:1301.4290 [pdf] - 696057
First demonstration of a sub-keV electron recoil energy threshold in a
liquid argon ionization chamber
Sangiorgio, S.;
Joshi, T. H.;
Bernstein, A.;
Coleman, J.;
Foxe, M.;
Hagmann, C.;
Jovanovic, I.;
Kazkaz, K.;
Mavrokoridis, K.;
Mozin, V.;
Pereverzev, S.;
Sorensen, P.
Submitted: 2013-01-17, last modified: 2013-07-19
We describe the first demonstration of a sub-keV electron recoil energy
threshold in a dual-phase liquid argon time projection chamber. This is an
important step in an effort to develop a detector capable of identifying the
ionization signal resulting from nuclear recoils with energies of order a few
keV and below. We obtained this result by observing the peaks in the energy
spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron
capture decay of Ar-37, respectively. The Ar-37 source preparation is described
in detail, since it enables calibration that may also prove useful in dark
matter direct detection experiments. An internally placed Fe-55 x-ray source
simultaneously provided another calibration point at 5.9 keV. We discuss the
ionization yield and electron recombination in liquid argon at those three
calibration energies.
[4]
oai:arXiv.org:1207.2164 [pdf] - 773381
Energy-resolved detection of single infrared photons with {\lambda} = 8
{\mu}m using a superconducting microbolometer
Submitted: 2012-07-09, last modified: 2012-07-20
We report on the detection of single photons with {\lambda} = 8 {\mu}m using
a superconducting hot-electron microbolometer. The sensing element is a
titanium transition-edge sensor with a volume ~ 0.1 {\mu}m^3 fabricated on a
silicon substrate. Poisson photon counting statistics including simultaneous
detection of 3 photons was observed. The width of the photon-number peaks was
0.11 eV, 70% of the photon energy, at 50-100 mK. This achieved energy
resolution is one of the best figures reported so far for superconducting
devices. Such devices can be suitable for single photon calorimetric
spectroscopy throughout the mid-infrared and even the far-infrared.
[5]
oai:arXiv.org:0710.5474 [pdf] - 634133
Ultra-Sensitive Hot-Electron Nanobolometers for Terahertz Astrophysics
Submitted: 2007-10-29
The background-limited spectral imaging of the early Universe requires
spaceborne terahertz (THz) detectors with the sensitivity 2-3 orders of
magnitude better than that of the state-of-the-art bolometers. To realize this
sensitivity without sacrificing operating speed, novel detector designs should
combine an ultrasmall heat capacity of a sensor with its unique thermal
isolation. Quantum effects in thermal transport at nanoscale put strong
limitations on the further improvement of traditional membrane-supported
bolometers. Here we demonstrate an innovative approach by developing
superconducting hot-electron nanobolometers in which the electrons are cooled
only due to a weak electron-phonon interaction. At T<0.1K, the electron-phonon
thermal conductance in these nanodevices becomes less than one percent of the
quantum of thermal conductance. The hot-electron nanobolometers, sufficiently
sensitive for registering single THz photons, are very promising for
submillimeter astronomy and other applications based on quantum calorimetry and
photon counting.