Normalized to: Pereira, A.
[1]
oai:arXiv.org:1909.12417 [pdf] - 1969685
Photometry and spectroscopy of massive stars observed during K2 Campaign
8
Submitted: 2019-09-26
We report in this paper spectroscopic and photometric analysis of eight
massive stars observed during Campaign 8 of the Kepler/K2 mission from January
to March 2016. Spectroscopic data were obtained on these stars at OPD/LNA,
Brazil, and their stellar parameters determined using SME. Periodic analyses of
the light curves were performed through CLEANEST and PERIOD04 algorithms. Mass,
luminosity, and radius of our stars were estimated employing CESAM+POSC grids.
Three of our stars show significant periodicity. K2 ID 220679442 and K2 ID
220532854 have periods linked to the stellar rotation. K2 ID 220532854 has
prominent silicon lines (Si II 4128-4131), a characteristic presented in the
peculiar class of Ap magnetic main sequence stars. However, in our spectral
analysis, this object was found to be an evolved, luminous giant star. K2 ID
220466722 was revealed to be a $\delta$ Scuti variable, and 40 individual
frequencies were determined for this star. No significant periodicity was found
in the light curves for the remaining stars analyzed in this work, besides the
instrumental one.
[2]
oai:arXiv.org:1806.11455 [pdf] - 1920780
Long term Experience in Autonomous Stations and production quality
control
Lopes, L.;
Alves, A. B.;
Assis, P.;
Blanco, A.;
Carolino, N.;
Cerda, M. A.;
Conceição, R.;
Cunha, O.;
Dobrigkeit, C.;
Ferreira, M.;
Fonte, P.;
de Almeida, L.;
Luz, R.;
Martins, V. B.;
Mendes, L.;
Nogueira, J. C.;
Pereira, A.;
Pimenta, M.;
Sarmento, R.;
de Souza, V.;
Tomé, B.
Submitted: 2018-06-29
Large area arrays composed by dispersed stations are of major importance in
experiments where Extended Air Shower (EAS) sampling is necessary. In those
dispersed stations is mandatory to have detectors that requires very low
maintenance and shows good resilience to environmental conditions. In 2012 our
group started to work in RPCs that could become acceptable candidates to
operate within these conditions. Since that time, more than 30 complete
detectors were produced, tested and installed in different places, both indoor
and outdoor. The data and analysis to be presented is manly related to the
tests made in the Auger site, where two RPCs are under test in real conditions
for more than two years. The results confirm the capability to operate such
kind of RPCs for long time periods under harsh conditions at a stable
efficiency. In the last years Lip and USP - S\~ao Carlos start collaboration
that aim to install an Eng. Array at BATATA (Auger) site to better study and
improve the resilience and performance of the RPCs in outdoor experiments. The
organization of such collaboration and the work done so far will be presented.
[3]
oai:arXiv.org:1712.07685 [pdf] - 1678504
MARTA: A high-energy cosmic-ray detector concept with high-accuracy muon
measurement
Abreu, P.;
Andringa, S.;
Assis, P.;
Blanco, A.;
Martins, V. Barbosa;
Brogueira, P.;
Carolino, N.;
Cazon, L.;
Cerda, M.;
Cernicchiaro, G.;
Colalillo, R.;
Conceição, R.;
Cunha, O.;
de Almeida, R. M.;
de Souza, V.;
Diogo, F.;
Dobrigkeit, C.;
Espadanal, J.;
Espirito-Santo, C.;
Ferreira, M.;
Ferreira, P.;
Fonte, P.;
Giaccari, U.;
Gonçalves, P.;
Guarino, F.;
Lippmann, O. C.;
Lopes, L.;
Luz, R.;
Maurizio, D.;
Marujo, F.;
Mazur, P.;
Mendes, L.;
Pereira, A.;
Pimenta, M.;
Prado, R. R.;
Rídký, J.;
Sarmento, R.;
Scarso, C.;
Shellard, R.;
Souza, J.;
Tomé, B.;
Trávnícek, P.;
Vícha, J.;
Wolters, H.;
Zas, E.
Submitted: 2017-12-20, last modified: 2018-04-20
A new concept for the direct measurement of muons in air showers is
presented. The concept is based on resistive plate chambers (RPCs), which can
directly measure muons with very good space and time resolution. The muon
detector is shielded by placing it under another detector able to absorb and
measure the electromagnetic component of the showers such as a water-Cherenkov
detector, commonly used in air shower arrays. The combination of the two
detectors in a single, compact detector unit provides a unique measurement that
opens rich possibilities in the study of air showers.
[4]
oai:arXiv.org:1709.09619 [pdf] - 1588977
Autonomous RPCs for a Cosmic Ray ground array
Assis, Pedro;
Blanco, Alberto;
Carolino, Nuno;
Conceição, Ruben;
Cunha, Orlando;
Dobrigkeit, Carola;
Ferreira, Miguel;
Fonte, Paulo;
Lopes, Luis;
Luz, Ricardo;
Martins, Victor Barbosa;
Mendes, Luis;
Pereira, Américo;
Pimenta, Mário;
Sarmento, Raul;
Shellard, Ronald;
de Souza, Vitor;
Tomé, Bernardo
Submitted: 2017-09-27
We report on the behaviour of Resistive Plate Chambers (RPC) developed for
muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs
were developed for the MARTA project and were tested on field conditions. These
RPCs cover an area of $1.5 \times 1.2\,{m^2}$ and are instrumented with 64
pickup electrodes providing a segmentation better than $20\,$cm. By shielding
the detector units with enough slant mass to absorb the electromagnetic
component in the air showers, a clean measurement of the muon content is
allowed, a concept to be implemented in a next generation of UHECR experiments.
The operation of a ground array detector poses challenging demands, as the RPC
must operate remotely under extreme environmental conditions, with limited
budgets for power and minimal maintenance. The RPC, DAQ, High Voltage and
monitoring systems are enclosed in an aluminium-sealed case, providing a
compact and robust unit suited for outdoor environments, which can be easily
deployed and connected. The RPCs developed at LIP-Coimbra are able to operate
using a very low gas flux, which allows running them for few years with a small
gas reservoir. Several prototypes have already been built and tested both in
the laboratory and outdoors. We report on the most recent tests done in the
field that show that the developed RPCs have operated in a stable way for more
than 2 years in field conditions.
[5]
oai:arXiv.org:physics/0501036 [pdf] - 119073
Performance of a Chamber for Studying the Liquid Xenon Response to
Nuclear Recoils
Chepel, V.;
Neves, F.;
Solovov, V.;
Pereira, A.;
Lopes, M. I.;
da Cunha, J. Pinto;
Mendes, P.;
Lindote, A.;
Silva, C. P.;
Marques, R. Ferreira;
Policarpo, A. J. P. L.
Submitted: 2005-01-07, last modified: 2005-01-14
The design and performance of a 1.2 liter liquid xenon chamber equipped with
7 two-inch photomultiplier tubes, with the purpose of studying the
scintillation response of xenon to gamma-rays and neutrons, is described.
Measurements with gamma-rays indicate a high VUV light collection efficiency
resulting in ~5.5 photoelectrons per 1 keV of deposited energy. The energy
resolution (FWHM) is 18% and 22%, for 122 keV and 511 keV gamma-rays,
respectively. An algorithm for the reconstruction of the scintillation
coordinates in (x,y) plane was developed and tested. The position resolution is
estimated to be 6.9 mm (sigma) for 122 keV gamma-rays.