Normalized to: Pelliciari, C.
[1]
oai:arXiv.org:1906.06093 [pdf] - 1900447
Calibration of X-ray telescope prototypes at PANTER
Liao, Ying-Yu;
Shen, Zheng-Xiang;
Yu, Jun;
Huang, Qiu-Shi;
Ma, Bin;
Zhang, Zhong;
Wang, Xiao-Qiang;
Wang, Kun;
Xie, Chun;
Burwitz, Vadim;
Hartner, Gisela;
La Caria, Marlis-Madeleine;
Pelliciari, Carlo;
Wang, Zhan-Shan
Submitted: 2019-06-14
We report a ground X-ray calibration of two X-ray telescope prototypes at the
PANTER X-ray Test Facility, of the Max-Planck-Institute for Extraterrestrial
Physics, in Neuried, Germany. The X-ray telescope prototypes were developed by
the Institute of Precision Optical Engineering (IPOE) of Tongji University, in
a conical Wolter-I configuration, using thermal glass slumping technology.
Prototype #1 with 3 layers and Prototype #2 with 21 layers were tested to
assess the prototypes' on-axis imaging performance. The measurement of
Prototype #1 indicates a Half Power Diameter (HPD) of 82" at 1.49 keV. As for
Prototype #2, we performed more comprehensive measurements of on-axis angular
resolution and effective area at several energies ranging from 0.5-10 keV. The
HPD and effective area are 111" and 39 cm^2 at 1.49 keV, respectively, at which
energy the on-axis performance of the prototypes is our greatest concern.
[2]
oai:arXiv.org:1610.09258 [pdf] - 1504566
Design and advancement status of the Beam Expander Testing X-ray
facility (BEaTriX)
Spiga, D.;
Pelliciari, C.;
Salmaso, B.;
Arcangeli, L.;
Bianucci, G.;
Ferrari, C.;
Ghigo, M.;
Pareschi, G.;
Rossi, M.;
Tagliaferri, G.;
Valsecchi, G.;
Vecchi, G.;
Zappettini, A.
Submitted: 2016-10-28
The BEaTriX (Beam Expander Testing X-ray facility) project is an X-ray
apparatus under construction at INAF/OAB to generate a broad (200 x 60 mm2),
uniform and low-divergent X-ray beam within a small lab (6 x 15 m2). BEaTriX
will consist of an X-ray source in the focus a grazing incidence paraboloidal
mirror to obtain a parallel beam, followed by a crystal monochromation system
and by an asymmetrically-cut diffracting crystal to perform the beam expansion
to the desired size. Once completed, BEaTriX will be used to directly perform
the quality control of focusing modules of large X-ray optics such as those for
the ATHENA X-ray observatory, based on either Silicon Pore Optics (baseline) or
Slumped Glass Optics (alternative), and will thereby enable a direct quality
control of angular resolution and effective area on a number of mirror modules
in a short time, in full X-ray illumination and without being affected by the
finite distance of the X-ray source. However, since the individual mirror
modules for ATHENA will have an optical quality of 3-4 arcsec HEW or better,
BEaTriX is required to produce a broad beam with divergence below 1-2 arcsec,
and sufficient flux to quickly characterize the PSF of the module without being
significantly affected by statistical uncertainties. Therefore, the optical
components of BEaTriX have to be selected and/or manufactured with excellent
optical properties in order to guarantee the final performance of the system.
In this paper we report the final design of the facility and a detailed
performance simulation.
[3]
oai:arXiv.org:1610.00272 [pdf] - 1490021
Manufacturing and testing a thin glass mirror shell with piezoelectric
active control
Spiga, D.;
Barbera, M.;
Collura, A.;
Basso, S.;
Candia, R.;
Civitani, M.;
Di Bella, M.;
Di Cicca, G.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.;
Varisco, S.
Submitted: 2016-10-02
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or silicon in order to keep the total mass within acceptable limits. Optical
modules based on thin slumped glass foils are being developed at various
institutes, aiming at improving the angular resolution to a few arcsec HEW.
Thin mirrors are prone to deform, so they require a careful integration to
avoid deformations and even correct forming errors. On the other hand, this
offers the opportunity to actively correct the residual deformation: a viable
possibility to improve the mirror figure is the application of piezoelectric
actuators onto the non-optical side of the mirrors, and several groups are
already at work on this approach. The concept we are developing consists of
actively integrating thin glass foils with piezoelectric patches, fed by
voltages driven by the feedback provided by X-rays. The actuators are
commercial components, while the tension signals are carried by a printed
circuit obtained by photolithography, and the driving electronic is a
multi-channel low power consumption voltage supply developed in-house. Finally,
the shape detection and the consequent voltage signal to be provided to the
piezoelectric array are determined in X-rays, in intra-focal setup at the XACT
facility at INAF/OAPA. In this work, we describe the manufacturing steps to
obtain a first active mirror prototype and the very first test performed in
X-rays.
[4]
oai:arXiv.org:1609.09677 [pdf] - 1489509
BEaTriX, expanded X-ray beam facility for testing modular elements of
telescope optics: an update
Submitted: 2016-09-30
We present in this paper an update on the design of BEaTriX (Beam Expander
Testing X-ray facility), an X-ray apparatus to be realized at INAF/OAB and that
will generate an expanded, uniform and parallel beam of soft X-rays. BEaTriX
will be used to perform the functional tests of X-ray focusing modules of large
X-ray optics such as those for the ATHENA X-ray observatory, using the Silicon
Pore Optics (SPO) as a baseline technology, and Slumped Glass Optics (SGO) as a
possible alternative. Performing the tests in X-rays provides the advantage of
an in-situ, at-wavelength quality control of the optical modules produced in
series by the industry, performing a selection of the modules with the best
angular resolution, and, in the case of SPOs, there is also the interesting
possibility to align the parabolic and the hyperbolic stacks directly under
X-rays, to minimize the aberrations. However, a parallel beam with divergence
below 2 arcsec is necessary in order to measure mirror elements that are
expected to reach an angular resolution of about 4 arcsec, since the ATHENA
requirement for the entire telescope is 5 arcsec. Such a low divergence over
the typical aperture of modular optics would require an X-ray source to be
located in a several kilometers long vacuum tube. In contrast, BEaTriX will be
compact enough (5 m x 14 m) to be housed in a small laboratory, will produce an
expanded X-ray beam 60 mm x 200 mm broad, characterized by a very low
divergence (1.5 arcsec HEW), strong polarization, high uniformity, and X-ray
energy selectable between 1.5 keV and 4.5 keV. In this work we describe the
BEaTriX layout and show a performance simulation for the X-ray energy of 4.5
keV.
[5]
oai:arXiv.org:1510.00910 [pdf] - 1287738
Active shape correction of a thin glass/plastic X-ray mirror
Spiga, D.;
Barbera, M.;
Basso, S.;
Civitani, M.;
Collura, A.;
Dell'Agostino, S.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.
Submitted: 2015-10-04
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or plastic in order to keep the total mass within acceptable limits. Optics
based on thin slumped glass foils are currently in use in the NuSTAR telescope
and are being developed at various institutes like INAF/OAB, aiming at
improving the angular resolution to a few arcsec HEW. Another possibility would
be the use of thin plastic foils, being developed at SAO and the Palermo
University. Even if relevant progresses in the achieved angular resolution were
recently made, a viable possibility to further improve the mirror figure would
be the application of piezoelectric actuators onto the non-optical side of the
mirrors. In fact, thin mirrors are prone to deform, so they require a careful
integration to avoid deformations and even correct forming errors. This however
offers the possibility to actively correct the residual deformation. Even if
other groups are already at work on this idea, we are pursuing the concept of
active integration of thin glass or plastic foils with piezoelectric patches,
fed by voltages driven by the feedback provided by X-rays, in intra-focal setup
at the XACT facility at INAF/OAPA. In this work, we show the preliminary
simulations and the first steps taken in this project.
[6]
oai:arXiv.org:1509.04770 [pdf] - 1278415
An expanded X-ray beam facility (BEaTriX) to test the modular elements
of the ATHENA optics
Submitted: 2015-09-15
Future large X-ray observatories like ATHENA will be equipped with very large
optics, obtained by assembling modular optical elements, named X-ray Optical
Units (XOU) based on the technology of either Silicon Pore Optics or Slumped
Glass Optics. In both cases, the final quality of the modular optic (a 5 arcsec
HEW requirement for ATHENA) is determined by the accuracy alignment of the XOUs
within the assembly, but also by the angular resolution of the individual XOU.
This is affected by the mirror shape accuracy, its surface roughness, and the
mutual alignment of the mirrors within the XOU itself. Because of the large
number of XOUs to be produced, quality tests need to be routinely done to
select the most performing stacked blocks, to be integrated into the final
optic. In addition to the usual metrology based on profile and roughness
measurements, a direct measurement with a broad, parallel, collimated and
uniform X- ray beam would be the most reliable test, without the need of a
focal spot reconstruction as usually done in synchrotron light. To this end, we
designed the BEaTriX (Beam Expander Testing X-ray facility) to be realized at
INAF-OAB, devoted to the functional tests of the XOUs. A grazing incidence
parabolic mirror and an asymmetrically cut crystal will produce a parallel
X-ray beam broad enough to illuminate the entire aperture of the focusing
elements. An X-ray camera at the focal distance from the mirrors will directly
record the image. The selection of different crystals will enable to test the
XOUs in the 1 - 5 keV range, included in the X-ray energy band of ATHENA
(0.2-12 keV). In this paper we discuss a possible BEaTriX facility
implementation. We also show a preliminary performance simulation of the
optical system.