Normalized to: Pelissier, A.
[1]
oai:arXiv.org:1403.6592 [pdf] - 873816
Impact of particles on the Planck HFI detectors: Ground-based
measurements and physical interpretation
Catalano, A.;
Ade, P.;
Atik, Y.;
Benoit, A.;
Bréele, E.;
Bock, J. J.;
Camus, P.;
Chabot, M.;
Charra, M.;
Crill, B. P.;
Coron, N.;
Coulais, A.;
Désert, F. -X.;
Fauvet, L.;
Giraud-Héraud, Y.;
Guillaudin, O.;
Holmes, W.;
Jones, W. C.;
Lamarre, J. -M.;
Macías-Pérez, J.;
Martinez, M.;
Miniussi, A.;
Monfardini, A.;
Pajot, F.;
Patanchon, G.;
Pelissier, A.;
Piat, M.;
Puget, J. -L.;
Renault, C.;
Rosset, C.;
Santos, D.;
Sauvé, A.;
Spencer, L. D.;
Sudiwala, R.
Submitted: 2014-03-26, last modified: 2014-09-02
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from
August 2009 to January 2012. Its noise and sensitivity performance were
excellent, but the rate of cosmic ray impacts on the HFI detectors was
unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane
produced transient signals in the data (glitches) with a wide range of
characteristics. A study of cosmic ray impacts on the HFI detector modules has
been undertaken to categorize and characterize the glitches, to correct the HFI
time-ordered data, and understand the residual effects on Planck maps and data
products. This paper presents an evaluation of the physical origins of glitches
observed by the HFI detectors. In order to better understand the glitches
observed by HFI in flight, several ground-based experiments were conducted with
flight-spare HFI bolometer modules. The experiments were conducted between 2010
and 2013 with HFI test bolometers in different configurations using varying
particles and impact energies. The bolometer modules were exposed to 23 MeV
protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm
$\alpha$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data
from the HFI ground-based preflight tests were used to further characterize the
glitches and compare glitch rates with statistical expectations under
laboratory conditions. Test results provide strong evidence that the dominant
family of glitches observed in flight are due to cosmic ray absorption by the
silicon die substrate on which the HFI detectors reside. Glitch energy is
propagated to the thermistor by ballistic phonons, while there is also a
thermal diffusion contribution. The implications of these results for future
satellite missions, especially those in the far-infrared to sub-millimetre and
millimetre regions of the electromagnetic spectrum, are discussed.
[2]
oai:arXiv.org:1403.5639 [pdf] - 800803
Characterization and Physical Explanation of Energetic Particles on
Planck HFI Instrument
Catalano, A.;
Ade, P.;
Atik, Y.;
Benoit, A.;
Bréele, E.;
Bock, J. J.;
Camus, P.;
Charra, M.;
Crill, B. P.;
Coron, N.;
Coulais, A.;
Désert, F. -X.;
Fauvet, L.;
Giraud-Héraud, Y.;
Guillaudin, O.;
Holmes, W.;
Jones, W. C.;
Lamarre, J. -M.;
Macías-Pérez, J.;
Martinez, M.;
Miniussi, A.;
Monfardini, A.;
Pajot, F.;
Patanchon, G.;
Pelissier, A.;
Piat, M.;
Puget, J. -L.;
Renault, C.;
Rosset, C.;
Santos, D.;
Sauvé, A.;
Spencer, L.;
Sudiwala, R.
Submitted: 2014-03-22
The Planck High Frequency Instrument (HFI) has been surveying the sky
continuously from the second Lagrangian point (L2) between August 2009 and
January 2012. It operates with 52 high impedance bolometers cooled at 100mK in
a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but
strong coupling with cosmic radiation. At L2, the particle flux is about 5
$cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft.
Protons with an energy above 40MeV can penetrate the focal plane unit box
causing two different effects: glitches in the raw data from direct interaction
of cosmic rays with detectors (producing a data loss of about 15% at the end of
the mission) and thermal drifts in the bolometer plate at 100mK adding
non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made
strong efforts in order to correct for this effect on the time ordered data and
final Planck maps. This work intends to give a view of the physical explanation
of the glitches observed in the HFI instrument in-flight. To reach this goal,
we performed several ground-based experiments using protons and $\alpha$
particles to test the impact of particles on the HFI spare bolometers with a
better control of the environmental conditions with respect to the in-flight
data. We have shown that the dominant part of glitches observed in the data
comes from the impact of cosmic rays in the silicon die frame supporting the
micro-machinced bolometric detectors propagating energy mainly by ballistic
phonons and by thermal diffusion. The implications of these results for future
satellite missions will be discussed.
[3]
oai:arXiv.org:1103.1321 [pdf] - 371120
Design and construction of a Cherenkov imager for charge measurement of
nuclear cosmic rays
Bourrion, O.;
Bernard, Ch.;
Bondoux, D.;
Bouly, J. L.;
Bouvier, J.;
Boyer, B.;
Brinet, M.;
Buenerd, M.;
Damieux, G.;
Derome, L.;
Eraud, L.;
Foglio, R.;
Fombaron, D.;
Grondin, D.;
Lee, M. H.;
Lutz, L.;
Marton, M.;
Menchaca-Rocha, A.;
Pelissier, A.;
Périé, J. N.;
Putze, A.;
Roudier, S.;
Sallaz-Damaz, Y.;
Seo, E. S.;
Scordilis, J. P.;
Yoon, Y. S.
Submitted: 2011-03-07, last modified: 2011-05-18
A proximity focusing Cherenkov imager called CHERCAM, has been built for the
charge measurement of nuclear cosmic rays with the CREAM instrument. It
consists of a silica aerogel radiator plane across from a detector plane
equipped with 1,600 1" diameter photomultipliers. The two planes are separated
by a ring expansion gap. The Cherenkov light yield is proportional to the
charge squared of the incident particle. The expected relative light collection
accuracy is in the few percents range. It leads to an expected single element
separation over the range of nuclear charge Z of main interest 1 < Z < 26.
CHERCAM is designed to fly with the CREAM balloon experiment. The design of the
instrument and the implemented technical solutions allowing its safe operation
in high altitude conditions (radiations, low pressure, cold) are presented.