Normalized to: Pecora, M.
[1]
oai:arXiv.org:1401.4948 [pdf] - 773020
The LAUE project and its main results
Virgilli, E.;
Frontera, F.;
Valsan, V.;
Liccardo, V.;
Carassiti, V.;
Squerzanti, S.;
Statera, M.;
Parise, M.;
Chiozzi, S.;
Evangelisti, F.;
Caroli, E.;
Stephen, J.;
Auricchio, N.;
Silvestri, S.;
Basili, A.;
Cassese, F.;
Recanatesi, L.;
Guidi, V.;
Bellucci, V.;
Camattari, R.;
Ferrari, C.;
Zappettini, A.;
Buffagni, E.;
Bonnini, E.;
Pecora, M.;
Mottini, S.;
Negri, B.
Submitted: 2014-01-20
We will describe the LAUE project, supported by the Italian Space Agency,
whose aim is to demonstrate the capability to build a focusing optics in the
hard X-/soft gamma-ray domain (80--600 keV). To show the lens feasibility, the
assembling of a Laue lens petal prototype with 20 m focal length is ongoing.
Indeed, a feasibility study, within the LAUE project, has demonstrated that a
Laue lens made of petals is feasible. Our goal is a lens in the 80-600 keV
energy band. In addition to a detailed description of the new LARIX facility,
in which the lens is being assembled, we will report the results of the project
obtained so far.
[2]
oai:arXiv.org:1310.0641 [pdf] - 1179666
Scientific prospects in soft gamma-ray astronomy enabled by the LAUE
project
Frontera, F.;
Virgilli, E.;
Valsan, V.;
Liccardo, V.;
Carassiti, V.;
Caroli, E.;
Cassese, F.;
Ferrari, C.;
Guidi, V.;
Mottini, S.;
Pecora, M.;
Negri, B.;
Recanatesi, L.;
Amati, L.;
Auricchio, N.;
Bassani, L.;
Campana, R.;
Farinelli, R.;
Guidorzi, C.;
Labanti, C.;
Landi, R.;
Malizia, A.;
Orlandini, M.;
Rosati, P.;
Sguera, V.;
Stephen, J.;
Titarchuk, L.
Submitted: 2013-10-02, last modified: 2014-01-02
This paper summarizes the development of a successful project, LAUE,
supported by the Italian Space Agency (ASI) and devoted to the development of
long focal length (up to 100 m) Laue lenses for hard X--/soft gamma--ray
astronomy (80-600 keV). The apparatus is ready and the assembling of a
prototype lens petal is ongoing. The great achievement of this project is the
use of bent crystals. From measurements obtained on single crystals and from
simulations, we have estimated the expected Point Spread Function and thus the
sensitivity of a lens made of petals. The expected sensitivity is a few
$\times10^{-8}$ photons cm$^{-2}$ s$^{-1}$ keV$^{-1}$. We discuss a number of
open astrophysical questions that can settled with such an instrument aboard a
free-flying satellite.
[3]
oai:arXiv.org:1211.4977 [pdf] - 1157954
Development status of the LAUE project
Frontera, F.;
Virgilli, E.;
Liccardo, V.;
Valsan, V.;
Carassiti, V.;
Chiozzi, S.;
Evangelisti, F.;
Squerzanti, S.;
Statera, M.;
Guidi, V.;
Ferrari, C.;
Zappettini, R. A.;
Caroli, E.;
Auricchio, N.;
Silvestri, S.;
Camattari, R.;
Cassese, F.;
Recanatesi, L.;
Pecora, M.;
Mottini, S.;
Negri, B.
Submitted: 2012-11-21
We present the status of LAUE, a project supported by the Italian Space
Agency (ASI), and devoted to develop Laue lenses with long focal length (up to
100 meters), for hard X--/soft gamma--ray astronomy (80-600 keV). Thanks to
their focusing capability, the design goal is to improve the sensitivity of the
current instrumention in the above energy band by 2 orders of magnitude, down
to a few times $10^{-8}$ photons/(cm$^2$ s keV).
[4]
oai:arXiv.org:1110.5434 [pdf] - 1085119
The LAUE project for broadband gamma-ray focusing lenses
Virgilli, E.;
Frontera, F.;
Valsan, V.;
Liccardo, V.;
Caroli, E.;
Stephen, J. B.;
Cassese, F.;
Recanatesi, L.;
Pecora, M.;
Mottini, S.;
Attiná, P.;
Negri, B.
Submitted: 2011-10-25
We present the LAUE project devoted to develop an advanced technology for
building a high focal length Laue lens for soft gamma--ray astronomy (80-600
keV). The final goal is to develop a focusing optics that can improve the
current sensitivity in the above energy band by 2 orders of magnitude.
[5]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[6]
oai:arXiv.org:1001.4686 [pdf] - 1477095
The PLANCK LFI flight model ortho-mode transducers
D'Arcangelo, O.;
Simonetto, A.;
Figini, L.;
Pagana, E.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Sozzi, C.
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array
of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70
GHz. LFI has been calibrated and delivered for integration with the satellite
to the European Space Agency on November 2006. The aim of Planck is to measure
the anisotropy and polarization of the Cosmic Background Radiation with a
sensitivity and angular resolution never reached before over the full sky. LFI
is intrinsically sensitive to polarization thanks to the use of Ortho-Mode
Transducers (OMT) located between the feedhorns and the pseudo-correlation
radiometers. The OMTs are microwave passive components that divide the incoming
radiation into two linear orthogonal components. A set of 11 OMTs (2 at 30 GHz,
3 at 44 GHz, and 6 at 70 GHz) were produced and tested. This work describes the
design, development and performance of the eleven Flight Model OMTs of LFI. The
final design was reached after several years of development. At first, Elegant
Bread Board OMTs were produced to investigate the manufacturing technology and
design requirements. Then, a set of 3 Qualification Model (QM) OMTs were
designed, manufactured and tested in order to freeze the design and the
manufacturing technology for the flight units. Finally, the Flight Models were
produced and tested. It is shown that all the OMT units have been accepted for
flight and the electromagnetic performance is at least marginally compliant
with the requirements. Mechanically, the units passed all the thermoelastic
qualification tests after a reworking necessary after the QM campaign.
[7]
oai:arXiv.org:1001.4633 [pdf] - 33153
Planck LFI flight model feed horns
Villa, F.;
D'Arcangelo, O.;
Pecora, M.;
Figini, L.;
Nesti, R.;
Simonetto, A.;
Sozzi, C.;
Sandri, M.;
Battaglia, P.;
Guzzi, P.;
Bersanelli, M.;
Butler, R. C.;
Mandolesi, N.
Submitted: 2010-01-26
this paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency
Instrument is optically interfaced with the ESA Planck telescope through 11
corrugated feed horns each connected to the Radiometer Chain Assembly (RCA).
This paper describes the design, the manufacturing and the testing of the
flight model feed horns. They have been designed to optimize the LFI optical
interfaces taking into account the tight mechanical requirements imposed by the
Planck focal plane layout. All the eleven units have been successfully tested
and integrated with the Ortho Mode transducers.
[8]
oai:arXiv.org:1001.4711 [pdf] - 33175
The Planck-LFI flight model composite waveguides
D'Arcangelo, O.;
Figini, L.;
Simonetto, A.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Mennella, A.;
Morgante, G.;
Pagan, L.;
Valenziano, L.
Submitted: 2010-01-26
The Low Frequency Instrument on board the PLANCK satellite is designed to
give the most accurate map ever of the CMB anisotropy of the whole sky over a
broad frequency band spanning 27 to 77 GHz. It is made of an array of 22
pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End
Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between
the two parts is made with rectangular Wave Guides. Considerations of different
nature (thermal, electromagnetic and mechanical), imposed stringent
requirements on the WGs characteristics and drove their design. From the
thermal point of view, the WG should guarantee good insulation between the FEM
and the BEM sections to avoid overloading the cryocooler. On the other hand it
is essential that the signals do not undergo excessive attenuation through the
WG. Finally, given the different positions of the FEM modules behind the focal
surface and the mechanical constraints given by the surrounding structures,
different mechanical designs were necessary. A composite configuration of
Stainless Steel and Copper was selected to satisfy all the requirements. Given
the complex shape and the considerable length (about 1.5-2 m), manufacturing
and testing the WGs was a challenge. This work deals with the development of
the LFI WGs, including the choice of the final configuration and of the
fabrication process. It also describes the testing procedure adopted to fully
characterize these components from the electromagnetic point of view and the
space qualification process they underwent. Results obtained during the test
campaign are reported and compared with the stringent requirements. The
performance of the LFI WGs is in line with requirements, and the WGs were
successfully space qualified.
[9]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[10]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.