sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Paufique, J.

Normalized to: Paufique, J.

6 article(s) in total. 80 co-authors, from 1 to 3 common article(s). Median position in authors list is 11,5.

[1]  oai:arXiv.org:2003.07228  [pdf] - 2064627
Design of the HARMONI Pyramid WFS module
Comments: 12 pages, 17 figures, AO4ELT6 Proceedings, Adaptive Optics for Extremely Large Telescopes 6, Conference Proceeding, Qu\'ebec City, Canada, Spain, June 9-14, 2019
Submitted: 2020-03-13
Current designs for all three extremely large telescopes show the overwhelming adoption of the pyramid wavefront sensor (P-WFS) as the WFS of choice for adaptive optics (AO) systems sensing on natural guide stars (NGS) or extended objects. The key advantages of the P-WFS over the Shack-Hartmann are known and are mainly provided by the improved sensitivity (fainter NGS) and reduced sensitivity to spatial aliasing. However, robustness and tolerances of the P-WFS for the ELTs are not currently well understood. In this paper, we present simulation results for the single-conjugate AO mode of HARMONI, a visible and near-infrared integral field spectrograph for the European Extremely Large Telescope. We first explore the wavefront sensing issues related to the telescope itself; namely the island effect (i.e. differential piston) and M1 segments phasing errors. We present mitigation strategies to the island effect and their performance. We then focus on some performance optimisation aspects of the AO design to explore the impact of the RTC latency and the optical gain issues, which will in particular affect the high-contrast mode of HARMONI. Finally, we investigate the influence of the quality of glass pyramid prism itself, and of optical aberrations on the final AO performance. By relaxing the tolerances on the fabrication of the prism, we are able to reduce hardware costs and simplify integration. We show the importance of calibration (i.e. updating the control matrix) to capture any displacement of the telescope pupil and rotation of the support structure for M4. We also show the importance of the number of pixels used for wavefront sensing to relax tolerances of the pyramid prism. Finally, we present a detailed optical design of the pyramid prism, central element of the P-WFS.
[2]  oai:arXiv.org:1809.08839  [pdf] - 1755233
Sensing and control of segmented mirrors with a pyramid wavefront sensor in the presence of spiders
Comments: 12 pages, 15 figures, AO4ELT5 Proceedings, Adaptive Optics for Extremely Large Telescopes 5, Conference Proceeding, Tenerife, Canary Islands, Spain, June 25-30, 2017
Submitted: 2018-09-24
The segmentation of the telescope pupil (by spiders & the segmented M4) create areas of phase isolated by the width of the spiders on the wavefront sensor (WFS), breaking the spatial continuity of the wavefront. The poor sensitivity of the Pyramid WFS (PWFS) to differential piston leads to badly seen and therefore uncontrollable differential pistons. In close loop operation, differential pistons between segments will settle around integer values of the average sensing wavelength. The differential pistons typically range from one to ten times the sensing wavelength and vary rapidly over time, leading to extremely poor performance. In addition, aberrations created by atmospheric turbulence will contain large amounts of differential piston between the segments. Removing piston contribution over each of the DM segments leads to poor performance. In an attempt to reduce the impact of unwanted differential pistons that are injected by the AO correction, we compare three different approaches. We first limit ourselves to only use the information measured by the PWFS, in particular by reducing the modulation. We show that using this information sensibly is important but will not be sufficient. We discuss possible ways of improvement by using prior information. A second approach is based on phase closure of the DM commands and assumes the continuity of the correction wavefront over the entire unsegmented pupil. The last approach is based on the pair-wise slaving of edge actuators and shows the best results. We compare the performance of these methods using realistic end-to-end simulations. We find that pair-wise slaving leads to a small increase of the total wavefront error, only adding between 20-45 nm RMS in quadrature for seeing conditions between 0.45-0.85 arcsec. Finally, we discuss the possibility of combining the different proposed solutions to increase robustness.
[3]  oai:arXiv.org:1805.11931  [pdf] - 1691645
The adaptive optics modes for HARMONI: from Classical to Laser Assisted Tomographic AO
Comments: SPIE proceeding, 2016
Submitted: 2018-05-30
HARMONI is a visible and NIR integral field spectrograph, providing the E-ELT's core spectroscopic capability at first light. HARMONI will work at the diffraction limit of the E-ELT, thanks to a Classical and a Laser Tomographic AO system. In this paper, we present the system choices that have been made for these SCAO and LTAO modules. In particular, we describe the strategy developed for the different Wave-Front Sensors: pyramid for SCAO, the LGSWFS concept, the NGSWFS path, and the truth sensor capabilities. We present first potential implementations. And we asses the first system performance.
[4]  oai:arXiv.org:1407.3057  [pdf] - 1215613
Concept and optical design of the cross-disperser module for CRIRES+
Comments: 14 pages, 9 figures, 22 tables. Presented at SPIE Astronomical Telescope + Instrumentation 2014 (Ground-based and Airbone Instrumentation for Astronomy 5, 9147-289). To be published in Proceeding of SPIE Volume 9147
Submitted: 2014-07-11
CRIRES, the ESO high resolution infrared spectrometer, is a unique instrument which allows astronomers to access a parameter space which up to now was largely uncharted. In its current setup, it consists of a single-order spectrograph providing long-slit, single-order spectroscopy with resolving power up to R=100,000 over a quite narrow spectral range. This has resulted in sub-optimal efficiency and use of telescope time for all the scientific programs requiring broad spectral coverage of compact objects (e.g. chemical abundances of stars and intergalactic medium, search and characterization of extra-solar planets). To overcome these limitations, a consortium was set-up for upgrading CRIRES to a cross-dispersed spectrometer, called CRIRES+. This paper presents the updated optical design of the crossdispersion module for CRIRES+. This new module can be mounted in place of the current pre-disperser unit. The new system yields a factor of >10 increase in simultaneous spectral coverage and maintains a quite long slit (10"), ideal for observations of extended sources and for precise sky-background subtraction.
[5]  oai:arXiv.org:astro-ph/0608010  [pdf] - 83887
On-sky results of the adaptive optics MACAO for the new IR-spectrograph CRIRES at VLT
Comments: SPIE conference 2006, Advances in adaptive optics, 12 pages, 11 figures
Submitted: 2006-08-01
The adaptive optics MACAO has been implemented in 6 focii of the VLT observatory, in three different flavors. We present in this paper the results obtained during the commissioning of the last of these units, MACAO-CRIRES. CRIRES is a high-resolution spectrograph, which efficiency will be improved by a factor two at least for point-sources observations with a NGS brighter than R=15. During the commissioning, Strehl exceeding 60% have been observed with fair seeing conditions, and a general description of the performance of this curvature adaptive optics system is done.
[6]  oai:arXiv.org:astro-ph/0608011  [pdf] - 83888
MACAO-CRIRES, a step towards high-resolution spectroscopy
Comments: SPIE conference 2004, Advances in adaptive optics, 12 pages, 15 figures
Submitted: 2006-08-01
High resolution spectroscopy made an important step ahead 10 years ago, leading for example to the discovery of numerous exoplanets. But the IR did not benefit from this improvement until very recently. CRIRES will provide a dramatic improvement in the 1-5 micron region in this field. Adaptive optics will allow us increasing both flux and angular resolution on its spectra. This paper describes the adaptive optics of CRIRES, its main limitations, its main components, the principle of its calibration with an overview of the methods used and the very first results obtained since it is installed in the laboratory.