Normalized to: Paubert, G.
[1]
oai:arXiv.org:2007.02702 [pdf] - 2128532
Detection of the magnetar XTE J1810-197 at 150 and 260 GHz with the
NIKA2 Kinetic Inductance Detector camera
Torne, P.;
Macías-Pérez, J.;
Ladjelate, B.;
Ritacco, A.;
Sánchez-Portal, M.;
Berta, S.;
Paubert, G.;
Calvo, M.;
Desvignes, G.;
Karuppusamy, R.;
Navarro, S.;
John, D.;
Sánchez, S.;
Peñalver, J.;
Kramer, M.;
Schuster, K.
Submitted: 2020-07-06
The investigation of pulsars between millimetre and optical wavelengths is
challenging due to the faintness of the pulsar signals and the relative low
sensitivity of the available facilities compared to 100-m class telescopes
operating in the centimetre band. The Kinetic Inductance Detector (KID)
technology offers large instantaneous bandwidths and a high sensitivity that
can help to substantially increase the ability of existing observatories at
short wavelengths to detect pulsars and transient emission. To investigate the
feasibility of detecting pulsars with KIDs, we observed the anomalous X-ray
pulsar XTE J1810-197 with the New IRAM KIDs Array-2 (NIKA2) camera installed at
the IRAM 30-m Telescope in Spain. We detected the pulsations from the pulsar
with NIKA2 at its two operating frequency bands, 150 and 260 GHz ($\lambda$=2.0
and 1.15 mm, respectively). This is the first time that a pulsar is detected
with a receiver based on KID technology in the millimetre band. In addition,
this is the first report of short millimetre emission from XTE J1810-197 after
its reactivation in December 2018, and it is the first time that the source is
detected at 260 GHz, which gives us new insights into the radio emission
process of the star.
[2]
oai:arXiv.org:1911.04544 [pdf] - 2034470
Simultaneous Millimeter-wave and X-ray monitoring of the Seyfert Galaxy
NGC 7469
Submitted: 2019-11-11
We report on daily monitoring of the Seyfert galaxy NGC 7469, around 95 GHz
and 143 GHz, with the IRAM 30 m radio telescope, and with the Swift X-Ray and
UV/Optical telescopes, over an overlapping period of 45 days. The source was
observed on 36 days with IRAM, and the flux density in both mm bands was on
average $\sim 10$ mJy, but varied by $\pm50\%$, and by up to a factor of 2
between days. The present IRAM variability parameters are consistent with
earlier CARMA monitoring, which had only 18 data points. The X-ray light curve
of NGC 7469 over the same period spans a factor of 5 in flux with small
uncertainties. Similar variability in the mm-band and in the X-rays lends
support to the notion of both sources originating in the same physical
component of the AGN, likely the accretion disk corona. Simultaneous monitoring
in eight UV/optical bands shows much less variability than the mm and X-rays,
implying this light originates from a different AGN component, likely the
accretion disk itself. We use a tentative 14 day lag of the X-ray light curve
with respect to the 95 GHz light curve to speculate on coronal implications.
More precise mm-band measurements of a sample of X-ray-variable AGN are needed,
preferably also on time scales of less than a day where X-rays vary
dramatically, in order to properly test the physical connection between the two
bands.
[3]
oai:arXiv.org:1809.08086 [pdf] - 1783923
The extraordinary composition of the "blue comet" C/2016 R2 (PanSTARRS)
Biver, N.;
Bockelée-Morvan, D.;
Paubert, G.;
Moreno, R.;
Crovisier, J.;
Boissier, J.;
Bertrand, E.;
Boussier, H.;
Kugel, F.;
McKay, A.;
Russo, N. Dello;
DiSanti, M. A.
Submitted: 2018-09-21
We present a multi-wavelength study of comet C/2016 R2 (PanSTARRS). This
comet was observed on 23-24 January 2018 with the IRAM 30m telescope, and in
January to March 2018 with the Nan\c{c}ay radio telescope. Visible spectroscopy
was performed in December 2017 and February 2018 with small amateur telescopes.
We report on measurements of CO, CH3OH, H2CO and HCN production rates, and on
the determination of the N2/CO abundance ratio. Several other species,
especially OH, were searched for but not detected. The inferred relative
abundances, including upper limits for sulfur species, are compared to those
measured in other comets at about the same heliocentric distance of about 2.8
AU. The coma composition of comet C/2016 R2 is very different from all other
comets observed so far, being rich in N2 and CO and dust poor. This suggests
that this comet might belong to a very rare group of comets formed beyond the
N2 ice line. Alternatively, comet C/2016 R2 (PanSTARRS) could be the fragment
of a large and differentiated transneptunian object, with properties
characteristic of volatile-enriched layers.
[4]
oai:arXiv.org:1709.08742 [pdf] - 1588862
POLAMI: Polarimetric Monitoring of Active Galactic Nuclei at Millimetre
Wavelengths. I. The program, calibration, and calibrators data products
Submitted: 2017-09-25
We describe the POLAMI program for the monitoring of all four Stokes
parameters of a sample of bright radio-loud active galactic nuclei with the
IRAM 30m telescope at 3.5 and 1.3mm. The program started in October 2006 and
accumulated, until August 2014, 2300 observations at 3.5mm, achieving a median
time sampling interval of 22 days for the sample of 37 sources. This first
paper explains the source selection, mostly blazars, the observing strategy and
data calibration, and gives the details of the instrumental polarisation
corrections. The sensitivity (1sigma) reached at 3.5mm is 0.5% (linear
polarisation degree), 4.7 deg. (polarisation angle), and 0.23% (circular
polarisation), while the corresponding values at 1.3mm are 1.7%, 9.9 deg., and
0.72%, respectively. The data quality is demonstrated by the time sequences of
our calibrators Mars and Uranus. For the quasar 3C286, widely used as a linear
polarisation calibrator, we give improved estimates of its linear polarisation,
and show for the first time occasional detections of its weak circular
polarisation, which suggests a small level of variability of the source at
millimeter wavelengths.
[5]
oai:arXiv.org:1705.04588 [pdf] - 1583380
Magnetic field in IRC+10216 and other C-Rich Evolved Stars
Submitted: 2017-05-12
During the transition from the Asymptotic Giant Branch (AGB) to Planetary
Nebulae (PN), the circumstellar geometry and morphology change dramatically.
Another characteristic of this transition is the high mass loss rate, that can
be partially explained by radiation pressure and a combination of various
factors like the stellar pulsation, the dust grain condensation and opacity in
the upper atmosphere. The magnetic field can also be one of the main
ingredients that shapes the stellar upper atmosphere and envelope. Our main
goal is to investigate for the first time the spatial distribution of the
magnetic field in the envelope of IRC+10216. More generally we intend to
determine the magnetic field strength in the circumstellar envelope (CSE) of
C-rich evolved stars, compare this field with previous studies for O-rich
stars, and constrain the variation of the magnetic field with r the distance to
the star's center. We use spectropolarimetric observations of the Stokes V
parameter, collected with Xpol on the IRAM-30m radiotelescope, observing the
Zeeman effect in seven hyperfine components of the CN J = 1-0 line. We use
Crutcher's method to estimate the magnetic field. For C-rich evolved stars, we
derive a magnetic field strength (B) between 1.6 and 14.2 mG while B is
estimated to be 6 mG for the proto-PN (PPN) AFGL618, and an upper value of 8 mG
is found for the PN NGC7027. These results are consistent with a decrease of B
as 1/r in the environment of AGB objects, i.e., with the presence of a toroidal
field. But this is not the case for PPN and PN stars. Our map of IRC+10216
suggests that the magnetic field is not homogeneously strong throughout or
aligned with the envelope and that the morphology of the CN emission might have
changed with time.
[6]
oai:arXiv.org:1610.07616 [pdf] - 1532214
Detection of the magnetar SGR J1745-2900 up to 291 GHz with evidence of
polarized millimetre emission
Submitted: 2016-10-24
In Torne et al. (2015), we showed detections of SGR J1745-2900 up to 225 GHz
(1.33 mm); at that time the highest radio frequency detection of pulsar
emission. In this work, we present the results of new observations of the same
magnetar with detections up to 291 GHz (1.03 mm), together with evidence of
linear polarization in its millimetre emission. SGR J1745-2900 continues to
show variability and is, on average, a factor $\sim$4 brighter in the
millimetre band than in our observations of July 2014. The new measured
spectrum is slightly inverted, with $\left<\alpha\right> = +0.4\pm0.2$ (for
$S_{\nu} \propto \nu^{\alpha})$. However, the spectrum does not seem to be well
described by a single power law, which might be due to the intrinsic
variability of the source, or perhaps a turn-up somewhere between 8.35 and 87
GHz. These results may help us to improve our still incomplete model of pulsar
emission and, in addition, they further support the search for and study of
pulsars located at the Galactic Centre using millimetre wavelengths.
[7]
oai:arXiv.org:1603.05006 [pdf] - 1392930
Isotopic ratios of H, C, N, O, and S in comets C/2012 F6 (Lemmon) and
C/2014 Q2 (Lovejoy)
Biver, N.;
Moreno, R.;
Bockelée-Morvan, D.;
Sandqvist, Aa.;
Colom, P.;
Crovisier, J.;
Lis, D. C.;
Boissier, J.;
Debout, V.;
Paubert, G.;
Milam, S.;
Hjalmarson, A.;
Lundin, S.;
Karlsson, T.;
Battelino, M.;
Frisk, U.;
Murtagh, D.;
team, the Odin
Submitted: 2016-03-16
The apparition of bright comets C/2012 F6 (Lemmon) and C/2014 Q2 (Lovejoy) in
March-April 2013 and January 2015, combined with the improved observational
capabilities of submillimeter facilities, offered an opportunity to carry out
sensitive compositional and isotopic studies of the volatiles in their coma. We
observed comet Lovejoy with the IRAM 30m telescope between 13 and 26 January
2015, and with the Odin submillimeter space observatory on 29 January - 3
February 2015. We detected 22 molecules and several isotopologues. The
H$_2^{16}$O and H$_2^{18}$O production rates measured with Odin follow a
periodic pattern with a period of 0.94 days and an amplitude of ~25%. The
inferred isotope ratios in comet Lovejoy are $^{16}$O/$^{18}$O = 499 $\pm$ 24
and D/H = 1.4 $\pm$ 0.4 $\times 10^{-4}$ in water, $^{32}$S/$^{34}$S = 24.7
$\pm$ 3.5 in CS, all compatible with terrestrial values. The ratio
$^{12}$C/$^{13}$C = 109 $\pm$ 14 in HCN is marginally higher than terrestrial
and $^{14}$N/$^{15}$N = 145 $\pm$ 12 in HCN is half the Earth ratio. Several
upper limits for D/H or 12C/13C in other molecules are reported. From our
observation of HDO in comet C/2014 Q2 (Lovejoy), we report the first D/H ratio
in an Oort Cloud comet that is not larger than the terrestrial value. On the
other hand, the observation of the same HDO line in the other Oort-cloud comet,
C/2012 F6 (Lemmon), suggests a D/H value four times higher. Given the previous
measurements of D/H in cometary water, this illustrates that a diversity in the
D/H ratio and in the chemical composition, is present even within the same
dynamical group of comets, suggesting that current dynamical groups contain
comets formed at very different places or times in the early solar system.
[8]
oai:arXiv.org:1504.07241 [pdf] - 1239432
Simultaneous multifrequency radio observations of the Galactic Centre
magnetar SGR J1745-2900
Torne, P.;
Eatough, R. P.;
Karuppusamy, R.;
Kramer, M.;
Paubert, G.;
Klein, B.;
Desvignes, G.;
Champion, D. J.;
Wiesemeyer, H.;
Kramer, C.;
Spitler, L. G.;
Thum, C.;
Güsten, R.;
Schuster, K. F.;
Cognard, I.
Submitted: 2015-04-27, last modified: 2015-06-30
We report on simultaneous observations of the magnetar SGR J1745-2900 at
frequencies $\nu = 2.54$ to $225\,\rm{GHz}$ using the Nancay 94-m equivalent,
Effelsberg 100-m, and IRAM 30-m radio telescopes. We detect SGR J1745-2900 up
to 225 GHz, the highest radio frequency detection of pulsed emission from a
neutron star to date. Strong single pulses are also observed from 4.85 up to
154 GHz. At the millimetre band we see significant flux density and spectral
index variabilities on time scales of tens of minutes, plus variability between
days at all frequencies. Additionally, SGR J1745-2900 was observed at a
different epoch at frequencies 296 to 472 GHz using the APEX 12-m radio
telescope, with no detections. Over the period MJD 56859.83-56862.93 the fitted
spectrum yields a spectral index of $\left<\alpha\right> = -0.4 \pm 0.1$ for a
reference flux density $\left< S_{154} \right> = 1.1 \pm 0.2\rm{\,mJy}$ (with
$S_{\nu} \propto {\nu}^{\alpha})$, a flat spectrum alike those of the other
radio-loud magnetars. These results show that strongly magnetized neutron stars
can be effective radio emitters at frequencies notably higher to what was
previously known and that pulsar searches in the Galactic Centre are possible
in the millimetre band.
[9]
oai:arXiv.org:1405.6605 [pdf] - 844903
Complex organic molecules in comets C/2012 F6 (Lemmon) and C/2013 R1
(Lovejoy): detection of ethylene glycol and formamide
Biver, N.;
Bockelée-Morvan, D.;
Debout, V.;
Crovisier, J.;
Boissier, J.;
Lis, D. C.;
Russo, N. Dello;
Moreno, R.;
Colom, P.;
Paubert, G.;
Vervack, R.;
Weaver, H. A.
Submitted: 2014-05-26
A spectral survey in the 1 mm wavelength range was undertaken in the
long-period comets C/2012 F6 (Lemmon) and C/2013 R1 (Lovejoy) using the 30 m
telescope of the Institut de radioastronomie millim\'etrique (IRAM) in April
and November-December 2013. We report the detection of ethylene glycol
(CH$_2$OH)$_2$ (aGg' conformer) and formamide (NH$_2$CHO) in the two comets.
The abundances relative to water of ethylene glycol and formamide are 0.2-0.3%
and 0.02% in the two comets, similar to the values measured in comet C/1995 O1
(Hale-Bopp). We also report the detection of HCOOH and CH$_3$CHO in comet
C/2013 R1 (Lovejoy), and a search for other complex species (methyl formate,
glycolaldehyde).
[10]
oai:arXiv.org:1201.4318 [pdf] - 1093138
Ammonia and other parent molecules in comet 10P/Tempel 2 from
Herschel/HIFI and ground-based radio observations
Biver, N.;
Crovisier, J.;
Bockelée-Morvan, D.;
Szutowicz, S.;
Lis, D. C.;
Hartogh, P.;
de Val-Borro, M.;
Moreno, R.;
Boissier, J.;
Kidger, M.;
Küppers, M.;
Paubert, G.;
Russo, N. Dello;
Vervack, R.;
Weaver, H.;
team, HssO
Submitted: 2012-01-20
The Jupiter-family comet 10P/Tempel 2 was observed during its 2010 return
with the Herschel Space Observatory. We present here the observation of the (J,
K) = (1, 0)-(0, 0) transition of ammonia at 572 GHz in this comet with the
Heterodyne Instrument for the Far Infrared (HIFI) of Herschel. We also report
on radio observations of other molecules (HCN, CH3OH, H2S and CS) obtained
during the 1999 return of the comet with the CSO telescope and the JCMT, and
during its 2010 return with the IRAM 30-m telescope. Molecular abundances
relative to water are 0.09%, 1.8%, 0.4%, and 0.08% for HCN, CH3OH, H2S, and CS,
respectively. An abundance of 0.5% for NH3 is obtained, which is similar to the
values measured in other comets. The hyperfine structure of the ammonia line is
resolved for the first time in an astronomical source. Strong anisotropy in the
outgassing is present in all observations from 1999 to 2010 and is modelled to
derive the production rates.
[11]
oai:arXiv.org:1102.5015 [pdf] - 1052325
Molecular investigations of comets C/2002 X5 (Kudo-Fujikawa), C/2002 V1
(NEAT), and C/2006 P1 (McNaught) at small heliocentric distances
Submitted: 2011-02-24
We present unique spectroscopic radio observations of comets C/2002 X5
(Kudo-Fujikawa), C/2002 V1 (NEAT), and C/2006 P1 (McNaught), which came within
$r_h ~ 0.2 AU of the Sun in 2003 and 2007. The molecules OH, HCN, HNC, CS, and
CH3OH were detected in each of these comets when they were exposed to strong
heating from the Sun. Both HC3N and HCO+ were detected in comets C/2002 X5 and
C/2006 P1, respectively. We show that in these very productive comets close to
the Sun screening of the photodissociation by the Sun UV radiation plays a
non-negligible role. Acceleration of the gas expansion velocity and day-night
asymmetry is also measured and modeled. The CS photodissociation lifetime was
constrained to be about 2.5 x 10**-5 s-1 at r_h = 1 AU. The relative abundances
are compared to values determined from more distant observations of C/2002 X5
or other comets. A high HNC/HCN production-rate ratio, in the range 10 to 30 %
between 0.5 and 0.1 AU from the Sun, is measured. The trend for a significant
enrichment in CS in cometary comae (CS/HCN proportional to r_h**-0.8) is
confirmed in all three comets. The CH3OH/HCN production rate ratio decreases at
low r_h. The HC3N/HCN production rate ratio in comet C/2002 X5 is four times
higher than measured in any other comet.
[12]
oai:arXiv.org:0806.1666 [pdf] - 13418
XPOL - the correlation polarimeter at the IRAM 30m telescope
Submitted: 2008-06-10
XPOL, the first correlation polarimeter at a large millimeter telescope, uses
a flexible digital correlator to measure all four Stokes parameters
simultaneously, i.e. the total power I, the linear polarization components Q
and U, and the circular polarization V. The versatility of the backend provides
adequate bandwidth for efficient continuum observations as well as sufficient
spectral resolution (40 kHz) for observations of narrow lines. We demonstrate
that the polarimetry specific calibrations are handled with sufficient
precision, in particular the relative phase between the Observatory's two
orthogonally linearly polarized receivers. The many facets of instrumental
polarization are studied at 3mm wavelength in all Stokes parameters: on-axis
with point sources and off-axis with beam maps. Stokes Q which is measured as
the power difference between the receivers is affected by instrumental
polarization at the 1.5% level. Stokes U and V which are measured as cross
correlations are very little affected (maximum sidelobes 0.6% (U) and 0.3%
(V)). These levels critically depend on the precision of the receiver
alignment. They reach these minimum levels set by small ellipticities of the
feed horns when alignment is optimum (<~ 0.3"). A second critical prerequisite
for low polarization sidelobes turned out to be the correct orientation of the
polarization splitter grid. Its cross polarization properties are modeled in
detail. XPOL observations are therefore limited only by receiver noise in
Stokes U and V even for extended sources. Systematic effects set in at the 1.5%
level in observations of Stokes Q. With proper precautions, this limitation can
be overcome for point sources. Stokes Q observations of extended sources are
the most difficult with XPOL.
[13]
oai:arXiv.org:astro-ph/0610717 [pdf] - 170560
Radio observations of comet 9P/Tempel 1 before and after Deep Impact
Biver, N.;
Bockelée-Morvan, D.;
Boissier, J.;
Crovisier, J.;
Colom, P.;
Lecacheux, A.;
Moreno, R.;
Paubert, G.;
Lis, D.;
Sumner, M.;
Frisk, U.;
Hjalmarson, A.;
Olberg, M.;
Winnberg, A.;
Florén, H. -G.;
Sandqvist, Aa.;
Kwok, Sun
Submitted: 2006-10-24
Comet 9P/Tempel 1 was the target of a multi-wavelength worldwide
investigation in 2005. The NASA Deep Impact mission reached the comet on 4.24
July 2005, delivering a 370 kg impactor which hit the comet at 10.3 km/s.
Following this impact, a cloud of gas and dust was excavated from the comet
nucleus. The comet was observed in 2005 prior to and after the impact, at 18-cm
wavelength with the Nan\c{c}ay radio telescope, in the millimetre range with
the IRAM and CSO radio telescopes, and at 557 GHz with the Odin satellite.
Post-impact observations at IRAM and CSO did not reveal a significant change
of the outgassing rates and relative abundances, with the exception of CH_3OH
which may have been more abundant by up to one order of magnitude in the
ejecta. Most other variations are linked to the intrinsic variability of the
comet. The Odin satellite monitored nearly continuously the H_2O line at 557
GHz during the 38 hours following the impact on the 4th of July, in addition to
weekly monitoring. Once the periodic variations related to the nucleus rotation
are removed, a small increase of outgassing related to the impact is present,
which corresponds to the release of \approx 5000+/-2000 tons of water. Two
other bursts of activity, also observed at other wavelengths, were seen on 23
June and 7 July; they correspond to even larger releases of gas.
[14]
oai:arXiv.org:astro-ph/0206486 [pdf] - 50117
Coordinated thermal and optical observations of Trans-Neptunian object
(20000) Varuna from Sierra Nevada
Submitted: 2002-06-27
We report on coordinated thermal and optical measurements of trans-Neptunian
object (20000) Varuna obtained in January-February 2002, respectively from the
IRAM 30-m and IAA 1.5 m telescopes. The optical data show a lightcurve with a
period of 3.176+/-0.010 hr, a mean V magnitude of 20.37+/-0.08 and a
0.42+/-0.01 magnitude amplitude. They also tentatively indicate that the
lightcurve is asymmetric and double-peaked. The thermal observations indicate a
1.12+/-0.41 mJy flux, averaged over the object's rotation. Combining the two
datasets, we infer that Varuna has a mean 1060(+180/-220) km diameter and a
mean 0.038(+0.022/-0.010) V geometric albedo, in general agreement with an
earlier determination using the same technique.
[15]
oai:arXiv.org:astro-ph/9706243 [pdf] - 1943592
A Multi-frequency campaign on the gamma-ray loud blazar W Comae
Maisack, M.;
Mannheim, K.;
Geckeler, R. D.;
Hillas, M.;
Katajainen, S.;
Marshall, F.;
Petry, D.;
Montigny, C. v.;
Paubert, G.;
Rose, J.;
Sillanpaeae, A.;
Takalo, L. O.;
Teraesranta, H.
Submitted: 1997-06-24
We report preliminary results of a multi-frequency campaign on the TeV
candidate blazar W Comae (z=0.102). Flux limits by Whipple and HEGRA show that
the TeV flux must be considerably below an E^-2 extrapolation of the EGRET
flux. In the framework of proton-initiated cascade models, this implies a
moderate amount of gamma-ray attenuation due to pair production in collisions
with low-energy photons of the extragalactic infrared background. In a simple
SSC model, the gamma-ray spectrum cuts off intrinsically just below TeV without
requiring external absorption.