Normalized to: Pattavina, L.
[1]
oai:arXiv.org:2004.06936 [pdf] - 2105692
RES-NOVA: A new neutrino observatory based on archaeological lead
Submitted: 2020-04-15, last modified: 2020-06-01
We propose the RES-NOVA project which will hunt neutrinos from core-collapse
supernovae (SN) via coherent elastic neutrino-nucleus scattering (CE$\nu$NS)
using an array of archaeological lead (Pb) based cryogenic detectors. The high
CE$\nu$NS cross-section on Pb and the ultra-high radiopurity of archaeological
Pb enable the operation of a high statistics experiment equally sensitive to
all neutrino flavors with reduced detector dimensions in comparison with
existing Neutrino Observatories, and easy scalability to larger detector
volumes. RES-NOVA is planned to operate according to three phases with
increasing detector volumes: (60 cm)$^3$, (140 cm)$^3$, and ultimately
15$\times$(140 cm)$^3$. It will be sensitive to SN bursts up to Andromeda with
5$\sigma$ sensitivity with already existing technology and will have excellent
energy resolution with $1$ keV threshold. Within our Galaxy, it will be
possible to discriminate core-collapse SNe from black hole forming collapses
with no ambiguity even in the first phase of RES-NOVA. The average neutrino
energy of all flavors, the SN neutrino light curve, and the total energy
emitted in neutrinos can potentially be constrained with a precision of few
$\%$ in the final detector phase. RES-NOVA will be sensitive to flavor-blind
neutrinos from the diffuse SN neutrino background with an exposure of $620$ ton
$\cdot$ y. The proposed RES-NOVA project has the potential to lay down the
foundations for a new generation of neutrino telescopes, while relying on a
very simple technological setup.
[2]
oai:arXiv.org:2005.02692 [pdf] - 2090731
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on
spin-dependent dark matter interactions with ordinary matter
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Breier, R.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuchs, D.;
Fuss, A.;
Ghete, V. M.;
Garai, A.;
Gorla, P.;
Hauff, D.;
Ješkovský, M.;
Jochum, J.;
Kaizer, J.;
Kaznacheeva, M.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Palušová, V.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Povinec, P.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Usherov, I.;
Wagner, F.;
Willers, M.;
Zema, V.;
Zeman, J.;
Brützam, M.;
Ganschow, S.
Submitted: 2020-05-06
In this work, a first cryogenic characterization of a scintillating
LiAlO$_{2}$ single crystal is presented. The results achieved show that this
material holds great potential as a target for direct dark matter search
experiments. Three different detector modules obtained from one crystal grown
at the Leibniz-Institut f\"ur Kristallz\"uchtung (IKZ) have been tested to
study different properties at cryogenic temperatures. Firstly, two 2.8 g twin
crystals were used to build different detector modules which were operated in
an above-ground laboratory at the Max Planck Institute for Physics (MPP) in
Munich, Germany. The first detector module was used to study the scintillation
properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an
energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive
limit on the spin-dependent dark matter particle-proton scattering cross
section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50
GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as
the main absorber was tested in an underground facility at the Laboratori
Nazionali del Gran Sasso (LNGS): from this measurement it was possible to
determine the radiopurity of the crystal and study the feasibility of using
this material as a neutron flux monitor for low-background experiments.
[3]
oai:arXiv.org:1905.07335 [pdf] - 2075555
Description of CRESST-III Data
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-05-17, last modified: 2020-04-06
In CRESST-III, 10 cryogenic detector modules optimized for low energy
thresholds were operated for almost two years (May 2016 - February 2018).
Together with this document we are publishing data from the best performing
detector module which has a nuclear recoil threshold of 30.1eV. With this
data-set we were able to set limits on the cross-section for spin-dependent and
spin-independent elastic scattering of dark matter particles off nuclei at dark
matter masses down to 160MeV/c$^2$. We publish the energies of all events after
data selection as well as of all events within the acceptance region for
dark-matter searches. In this document we describe how to use these data sets.
[4]
oai:arXiv.org:1902.07587 [pdf] - 2045154
First results on sub-GeV spin-dependent dark matter interactions with
$^{7}$Li
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.;
Chapellier, M.;
Giuliani, A.;
Nones, C.;
Poda, D. V.;
Shlegel, V. N.;
Velázquez, M.;
Zolotarova, A. S.
Submitted: 2019-02-20, last modified: 2019-09-04
In this work, we want to highlight the potential of lithium as a target for
spin-dependent dark matter search in cryogenic experiments, with a special
focus on the low-mass region of the parameter space. We operated a prototype
detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground
laboratory. Despite the high background environment, the detector sets
competitive limits on spin-dependent interactions of dark matter particles with
protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
[5]
oai:arXiv.org:1908.06755 [pdf] - 2001880
Geant4-based electromagnetic background model for the CRESST dark matter
experiment
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Breier, R.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Fichtinger, S.;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Ješkovský, M.;
Jochum, J.;
Kaizer, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragón, E.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Palušová, V.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Povinec, P.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoğlu, C.;
Usherov, I.;
Willers, M.;
Zema, V.;
Zeman, J.
Submitted: 2019-08-19
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers)
dark matter search experiment aims for the detection of dark matter particles
via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand
the CRESST electromagnetic background due to the bulk contamination in the
employed materials, a model based on Monte Carlo simulations was developed
using the Geant4 simulation toolkit. The results of the simulation are applied
to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to
$(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy
range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.
[6]
oai:arXiv.org:1904.00498 [pdf] - 2007901
First results from the CRESST-III low-mass dark matter program
CRESST Collaboration;
Abdelhameed, A. H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bertoldo, E.;
Bucci, C.;
Canonica, L.;
D'Addabbo, A.;
Defay, X.;
Di Lorenzo, S.;
Erb, A.;
Feilitzsch, F. v.;
Fichtinger, S.;
Iachellini, N. Ferreiro;
Fuss, A.;
Gorla, P.;
Hauff, D.;
Jochum, J.;
Kinast, A.;
Kluck, H.;
Kraus, H.;
Langenkämper, A.;
Mancuso, M.;
Mokina, V.;
Mondragon, E.;
Münster, A.;
Olmi, M.;
Ortmann, T.;
Pagliarone, C.;
Pattavina, L.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schipperges, V.;
Schmiedmayer, D.;
Schönert, S.;
Schwertner, C.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Türkoglu, C.;
Usherov, I.;
Willers, M.;
Zema, V.
Submitted: 2019-03-31
The CRESST experiment is a direct dark matter search which aims to measure
interactions of potential dark matter particles in an earth-bound detector.
With the current stage, CRESST-III, we focus on a low energy threshold for
increased sensitivity towards light dark matter particles. In this manuscript
we describe the analysis of one detector operated in the first run of
CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV.
This result was obtained with a 23.6g CaWO$_4$ crystal operated as a cryogenic
scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del
Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously
emitted scintillation light, which is absorbed in a separate
silicon-on-sapphire light absorber, are measured with highly sensitive
transition edge sensors operated at ~15mK. The unique combination of these
sensors with the light element oxygen present in our target yields sensitivity
to dark matter particle masses as low as 160MeV/c$^2$.
[7]
oai:arXiv.org:1405.3782 [pdf] - 862787
Search for axioelectric effect of solar axions using BGO scintillating
bolometer
Derbin, A. V.;
Gironi, L.;
Nagorny, S. S.;
Pattavina, L.;
Beeman, J. W.;
Bellini, F.;
Biassoni, M.;
Capelli, S.;
Clemenza, M.;
Drachnev, I. S.;
Ferri, E.;
Giachero, A.;
Gotti, C.;
Kayunov, A. S.;
Maiano, C.;
Maino, M.;
Muratova, V. N.;
Pavan, M.;
Pirro, S.;
Sisti, M.;
Semenov, D. A.;
Unzhakov, E. V.
Submitted: 2014-05-15, last modified: 2014-09-08
A search for axioelectric absorption of solar axions produced in the $ p + d
\rightarrow {^3\rm{He}}+\gamma~(5.5~ \rm{MeV})$ reactions has been performed
with a BGO detector placed in a low-background setup. A model-independent limit
on an axion-nucleon and axion-electron coupling constant has been obtained: $|
g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90% confidence level. The
constrains of the axion-electron coupling have been obtained for hadronic axion
with masses in (0.1 - 1) MeV range: $|g_{Ae}| \leq (0.96 - 8.2)\times 10^{-8}$.
[8]
oai:arXiv.org:1209.2519 [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter
perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.;
Ardito, R.;
Artusa, D. R.;
Avignone, F. T.;
Azzolini, O.;
Balata, M.;
Banks, T. I.;
Bari, G.;
Beeman, J.;
Bellini, F.;
Bersani, A.;
Biassoni, M.;
Bloxham, T.;
Brofferio, C.;
Bucci, C.;
Cai, X. Z.;
Canonica, L.;
Capelli, S.;
Carbone, L.;
Cardani, L.;
Carrettoni, M.;
Casali, N.;
Chott, N.;
Clemenza, M.;
Cosmelli, C.;
Cremonesi, O.;
Creswick, R. J.;
Dafinei, I.;
Dally, A.;
Datskov, V.;
De Biasi, A.;
Decowski, M. P.;
Deninno, M. M.;
Di Domizio, S.;
di Vacri, M. L.;
Ejzak, L.;
Faccini, R.;
Fang, D. Q.;
Farach, H. A.;
Ferri, E.;
Ferroni, F.;
Fiorini, E.;
Franceschi, M. A.;
Freedman, S. J.;
Frossati, G.;
Fujikawa, B. K.;
Giachero, A.;
Gironi, L.;
Giuliani, A.;
Goett, J. J.;
Gorla, P.;
Gotti, C.;
Guardincerri, E.;
Gutierrez, T. D.;
Haller, E. E.;
Han, K.;
Heeger, K. M.;
Huang, H. Z.;
Kadel, R.;
Kazkaz, K.;
Keppel, G.;
Kogler, L.;
Kolomensky, Yu. G.;
Lenz, D.;
Li, Y. L.;
Ligi, C.;
Liu, X.;
Ma, Y. G.;
Maiano, C.;
Maino, M.;
Martinez, M.;
Maruyama, R. H.;
Moggi, N.;
Morganti, S.;
Napolitano, T.;
Newman, S.;
Nisi, S.;
Nones, C.;
Norman, E. B.;
Nucciotti, A.;
Orio, F.;
Orlandi, D.;
Ouellet, J. L.;
Pallavicini, M.;
Palmieri, V.;
Pattavina, L.;
Pavan, M.;
Pedretti, M.;
Pessina, G.;
Pirro, S.;
Previtali, E.;
Rampazzo, V.;
Rimondi, F.;
Rosenfeld, C.;
Rusconi, C.;
Sangiorgio, S.;
Scielzo, N. D.;
Sisti, M.;
Smith, A. R.;
Stivanello, F.;
Taffarello, L.;
Tenconi, M.;
Tian, W. D.;
Tomei, C.;
Trentalange, S.;
Ventura, G.;
Vignati, M.;
Wang, B. S.;
Wang, H. W.;
Whitten, C. A.;
Wise, y T.;
Woodcraft, A.;
Zanotti, L.;
Zarra, C.;
Zhu, B. X.;
Zucchelli, S.
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.
[9]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[10]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.