Normalized to: Paterakis, G.
[1]
oai:arXiv.org:1902.08367 [pdf] - 1842560
RoboPol: A four-channel optical imaging polarimeter
Ramaprakash, A. N.;
Rajarshi, C. V.;
Das, H. K.;
Khodade, P.;
Modi, D.;
Panopoulou, G.;
Maharana, S.;
Blinov, D.;
Angelakis, E.;
Casadio, C.;
Fuhrmann, L.;
Hovatta, T.;
Kiehlmann, S.;
King, O. G.;
Kylafis, N.;
Kougentakis, A.;
Kus, A.;
Mahabal, A.;
Marecki, A.;
Myserlis, I.;
Paterakis, G.;
Paleologou, E.;
Liodakis, I.;
Papadakis, I.;
Papamastorakis, I.;
Pavlidou, V.;
Pazderski, E.;
Pearson, T. J.;
Readhead, A. C. S.;
Reig, P.;
Slowikowska, A.;
Tassis, K.;
Zensus, J. A.
Submitted: 2019-02-22
We present the design and performance of RoboPol, a four-channel optical
polarimeter operating at the Skinakas Observatory in Crete, Greece. RoboPol is
capable of measuring both relative linear Stokes parameters $q$ and $u$ (and
the total intensity $I$) in one sky exposure. Though primarily used to measure
the polarization of point sources in the R-band, the instrument features
additional filters (B, V and I), enabling multi-wavelength imaging polarimetry
over a large field of view (13.6' $\times$ 13.6'). We demonstrate the accuracy
and stability of the instrument throughout its five years of operation. Best
performance is achieved within the central region of the field of view and in
the R band. For such measurements the systematic uncertainty is below 0.1% in
fractional linear polarization, $p$ (0.05% maximum likelihood). Throughout all
observing seasons the instrumental polarization varies within 0.1% in $p$ and
within 1$^\circ$ in polarization angle.
[2]
oai:arXiv.org:1310.7555 [pdf] - 1180292
The RoboPol Pipeline and Control System
King, O. G.;
Blinov, D.;
Ramaprakash, A. N.;
Myserlis, I.;
Angelakis, E.;
Baloković, M.;
Feiler, R.;
Fuhrmann, L.;
Hovatta, T.;
Khodade, P.;
Kougentakis, A.;
Kylafis, N.;
Kus, A.;
Paleologou, E.;
Panopoulou, G.;
Papadakis, I.;
Papamastorakis, I.;
Paterakis, G.;
Pavlidou, V.;
Pazderska, B.;
Pazderski, E.;
Pearson, T. J.;
Rajarshi, C.;
Readhead, A. C. S.;
Reig, P.;
Rouneq, R.;
Steiakaki, A.;
Tassis, K.;
Zensus, J. A.
Submitted: 2013-10-28, last modified: 2014-03-07
We describe the data reduction pipeline and control system for the RoboPol
project. The RoboPol project is monitoring the optical $R$-band magnitude and
linear polarization of a large sample of active galactic nuclei that is
dominated by blazars. The pipeline calibrates and reduces each exposure frame,
producing a measurement of the magnitude and linear polarization of every
source in the $13'\times 13'$ field of view. The control system combines a
dynamic scheduler, real-time data reduction, and telescope automation to allow
high-efficiency unassisted observations.
[3]
oai:arXiv.org:astro-ph/0111022 [pdf] - 45788
Seeing Measurements at Skinakas Observatory using the DIMM method
Submitted: 2001-11-01
We present preliminary results from a study of the seeing at Skinakas
Observatory in Crete, Greece. The measurements have been made during the years
2000 and 2001 using a two-aperture Differential Image Motion Monitor (DIMM).
The results of both campaigns are extremely promising with the median seeing
value being 0.''64 and 0.''69, respectively.