Normalized to: Patel, V.
[1]
oai:arXiv.org:1710.07391 [pdf] - 1590057
Design & development of position sensitive detector for hard X-ray using
SiPM and new generation scintillators
Goyal, S. K.;
Naik, Amisha P.;
S., Mithun N. P.;
Vadawale, S. V.;
Tiwari, Neeraj K.;
Chattopadhyay, T.;
Nagrani, N.;
Madhavi, S.;
ladiya, T.;
Patel, A. R.;
Shanmugam, M.;
Adalja, H. L.;
patel, V. R.;
Ubale, G. P.
Submitted: 2017-10-19
There is growing interest in high-energy astrophysics community for the
development of sensitive instruments in the hard X-ray energy extending to few
hundred keV. This requires position sensitive detector modules with high
efficiency in the hard X-ray energy range. Here, we present development of a
detector module, which consists of 25 mm x 25 mm CeBr3 scintillation detector,
read out by a custom designed two dimensional array of Silicon
Photo-Multipliers (SiPM). Readout of common cathode of SiPMs provides the
spectral measurement whereas the readout of individual SiPM anodes provides
measurement of interaction position in the crystal. Preliminary results for
spectral and position measurements with the detector module are presented here.
[2]
oai:arXiv.org:1510.06780 [pdf] - 1298705
Development of a Hard X-ray focal plane Compton Polarimeter: A compact
polarimetric configuration with Scintillators and Si photomultipliers
Chattopadhyay, T.;
Vadawale, S. V.;
Goyal, S. K.;
S., Mithun N. P.;
Patel, A. R.;
Shukla, R.;
Ladiya, T.;
Shanmugam, M.;
Patel, V. R.;
Ubale, G. P.
Submitted: 2015-10-22
X-ray polarization measurement of cosmic sources provides two unique
parameters namely degree and angle of polarization which can probe the emission
mechanism and geometry at close vicinity of the compact objects. Specifically,
the hard X-ray polarimetry is more rewarding because the sources are expected
to be intrinsically highly polarized at higher energies. With the successful
implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive
Compton polarimeters as focal plane detectors. Such a configuration is likely
to provide sensitive polarization measurements in hard X-rays with a broad
energy band. We are developing a focal plane hard X-ray Compton polarimeter
consisting of a plastic scintillator as active scatterer surrounded by a
cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and
100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons
scattered by the plastic scatterer are collected by a cylindrical array of 16
CsI(Tl) scintillators (5 mm x 5 mm x 150 mm) which are read by Si
Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness
of the instrument which is essential for the design of focal plane detectors.
The expected sensitivity of such polarimetric configuration and complete
characterization of the plastic scatterer, specially at lower energies have
been discussed in Chattopadhyay et al. (Exp. Astron. 35, 391-412, 2013;
Astrophys. J. Suppl. 212, 12, 2014). In this paper, we characterize the CsI(Tl)
absorbers coupled to SiPM. We also present the experimental results from the
fully assembled configuration of the Compton polarimeter.