Normalized to: Passerini, A.
[1]
oai:arXiv.org:2006.14889 [pdf] - 2122751
A chemically etched corrugated feedhorn array for D-band CMB
observations
Mandelli, Stefano;
Manzan, Elenia;
Mennella, Aniello;
Cavaliere, Francesco;
Viganò, Daniele;
Franceschet, Cristian;
de Bernardis, Paolo;
Bersanelli, Marco;
Castellano, Maria Gabriella;
Coppolecchia, Alessandro;
Cruciani, Angelo;
Gervasi, Massimo;
Lamagna, Luca;
Limonta, Andrea;
Masi, Silvia;
Paiella, Alessandro;
Passerini, Andrea;
Pettinari, Giorgio;
Piacentini, Francesco;
Tommasi, Elisabetta;
Volpe, Angela;
Zannoni, Mario
Submitted: 2020-06-26
We present the design, manufacturing, and testing of a 37-element array of
corrugated feedhorns for Cosmic Microwave Background (CMB) measurements between
$140$ and $170$ GHz. The array was designed to be coupled to Kinetic Inductance
Detector arrays, either directly (for total power measurements) or through an
orthomode transducer (for polarization measurements). We manufactured the array
in platelets by chemically etching aluminum plates of $0.3$ mm and $0.4$ mm
thickness. The process is fast, low-cost, scalable, and yields high-performance
antennas compared to other techniques in the same frequency range. Room
temperature electromagnetic measurements show excellent repeatability with an
average cross polarization level about $-20$ dB, return loss about $-25$ dB,
first sidelobes below $-25$ dB and far sidelobes below $-35$ dB. Our results
qualify this process as a valid candidate for state-of-the-art CMB experiments,
where large detector arrays with high sensitivity and polarization purity are
of paramount importance in the quest for the discovery of CMB polarization
$B$-modes.
[2]
oai:arXiv.org:2005.01187 [pdf] - 2089273
Progress report on the Large Scale Polarization Explorer
Lamagna, L.;
Addamo, G.;
Ade, P. A. R.;
Baccigalupi, C.;
Baldini, A. M.;
Battaglia, P. M.;
Battistelli, E.;
Baù, A.;
Bersanelli, M.;
Biasotti, M.;
Boragno, C.;
Boscaleri, A.;
Caccianiga, B.;
Caprioli, S.;
Cavaliere, F.;
Cei, F.;
Cleary, K. A.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Corsini, D.;
Cuttaia, F.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Del Torto, F.;
Fafone, V.;
Farooqui, Z.;
Farsian, F.;
Fontanelli, F.;
Franceschet, C.;
Gaier, T. C.;
Gatti, F.;
Genova-Santos, R.;
Gervasi, M.;
Ghigna, T.;
Grassi, M.;
Grosso, D.;
Gualtieri, R.;
Incardona, F.;
Jones, M.;
Kangaslahti, P.;
Krachmalnicoff, N.;
Mainini, R.;
Maino, D.;
Mandelli, S.;
Maris, M.;
Masi, S.;
Matarrese, S.;
May, A.;
Mena, P.;
Mennella, A.;
Molina, R.;
Molinari, D.;
Morgante, G.;
Nati, F.;
Natoli, P.;
Pagano, L.;
Paiella, A.;
Paonessa, F.;
Passerini, A.;
Perez-de-Taoro, M.;
Peverini, O. A.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Polastri, L.;
Polenta, G.;
Poletti, D.;
Presta, G.;
Realini, S.;
Reyes, N.;
Rocchi, A.;
Rubiño-Martin, J. A.;
Sandri, M.;
Sartor, S.;
Schillaci, A.;
Signorelli, G.;
Siri, B.;
Soria, M.;
Spinella, F.;
Tapia, V.;
Tartari, A.;
Taylor, A.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Tucker, C.;
Vaccaro, D.;
Vigano, D. M.;
Villa, F.;
Virone, G.;
Vittorio, N.;
Volpe, A.;
Watkins, B.;
Zacchei, A.;
Zannoni, M.
Submitted: 2020-05-03, last modified: 2020-05-05
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the
measurement of large scale curl-like features (B-modes) in the polarization of
the Cosmic Microwave Background. Its goal is to constrain the background of
inflationary gravity waves traveling through the universe at the time of
matter-radiation decoupling. The two instruments of LSPE are meant to
synergically operate by covering a large portion of the northern microwave sky.
LSPE/STRIP is a coherent array of receivers planned to be operated from the
Teide Observatory in Tenerife, for the control and characterization of the
low-frequency polarized signals of galactic origin; LSPE/SWIPE is a
balloon-borne bolometric polarimeter based on 330 large throughput multi-moded
detectors, designed to measure the CMB polarization at 150 GHz and to monitor
the polarized emission by galactic dust above 200 GHz. The combined performance
and the expected level of systematics mitigation will allow LSPE to constrain
primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report
the status of the STRIP pre-commissioning phase and the progress in the
characterization of the key subsystems of the SWIPE payload (namely the
cryogenic polarization modulation unit and the multi-moded TES pixels) prior to
receiver integration.
[3]
oai:arXiv.org:2001.10272 [pdf] - 2065386
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Battistelli, E. S.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Baù, A.;
Bèlier, B.;
Bennett, D.;
Bergè, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Dheilly, S.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
Garcìa, B.;
Redondo, M. E. Garcìa;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gòmez;
Gonzàlez, M.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillè, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Marty, W.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
Olivieri, E.;
Oriol, C.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Prèle, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Salum, J. M.;
Schillaci, A.;
Scòccola, C.;
Scully, S.;
Spinelli, S.;
Stankowiak, G.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Thermeau, J. -P.;
Timbie, P.;
Tomasi, M.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2020-01-28
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative
experiment designed to measure the polarization of the Cosmic Microwave
Background and in particular the signature left therein by the inflationary
expansion of the Universe. The expected signal is extremely faint, thus extreme
sensitivity and systematic control are necessary in order to attempt this
measurement. QUBIC addresses these requirements using an innovative approach
combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with
the deep control of systematics characteristic of interferometers. This makes
QUBIC unique with respect to others classical imagers experiments devoted to
the CMB polarization. In this contribution we report a description of the QUBIC
instrument including recent achievements and the demonstration of the
bolometric interferometry performed in lab. QUBIC will be deployed at the
observation site in Alto Chorrillos, in Argentina at the end of 2019.
[4]
oai:arXiv.org:1911.12418 [pdf] - 2011325
QUBIC: using NbSi TESs with a bolometric interferometer to characterize
the polarisation of the CMB
Piat, M.;
Bélier, B.;
Bergé, L.;
Bleurvacq, N.;
Chapron, C.;
Dheilly, S.;
Dumoulin, L.;
González, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Henrot-Versillé, S.;
Hoang, D. T.;
Marnieros, S.;
Marty, W.;
Montier, L.;
Olivieri, E.;
Oriol, C.;
Perbost, C.;
Prêle, D.;
Rambaud, D.;
Salatino, M.;
Stankowiak, G.;
Thermeau, J. -P.;
Torchinsky, S.;
Voisin, F.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bennett, D.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
García, B.;
Redondo, M. E. García;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gómez;
Gradziel, M.;
Harari, D.;
Haynes, V.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Puddu, R.;
Ringegni, P.;
Romero, G. E.;
Salum, J. M.;
Schillaci, A.;
Scóccola, C.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tomasi, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2019-11-27, last modified: 2019-12-09
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international
ground-based experiment dedicated in the measurement of the polarized
fluctuations of the Cosmic Microwave Background (CMB). It is based on
bolometric interferometry, an original detection technique which combine the
immunity to systematic effects of an interferometer with the sensitivity of low
temperature incoherent detectors. QUBIC will be deployed in Argentina, at the
Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta
province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors
(TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain
Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at
1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K
allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a
reduced number of detectors before upgrading to the full instrument. I will
present the last results of this characterization phase with a focus on the
detectors and readout system.
[5]
oai:arXiv.org:1812.00785 [pdf] - 1820173
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric
Interferometer
Mennella, Aniello;
Ade, Peter;
Amico, Giorgio;
Auguste, Didier;
Aumont, Jonathan;
Banfi, Stefano;
Barbaràn, Gustavo;
Battaglia, Paola;
Battistelli, Elia;
Baù, Alessandro;
Bélier, Benoit;
Bennett, David G.;
Bergé, Laurent;
Bernard, Jean Philippe;
Bersanelli, Marco;
Sazy, Marie Anne Bigot;
Bleurvacq, Nathat;
Bonaparte, Juan;
Bonis, Julien;
Bunn, Emory F.;
Burke, David;
Buzi, Daniele;
Buzzelli, Alessandro;
Cavaliere, Francesco;
Chanial, Pierre;
Chapron, Claude;
Charlassier, Romain;
Columbro, Fabio;
Coppi, Gabriele;
Coppolecchia, Alessandro;
D'Agostino, Rocco;
D'Alessandro, Giuseppe;
De Bernardis, Paolo;
De Gasperis, Giancarlo;
De Leo, Michele;
De Petris, Marco;
Di Donato, Andres;
Dumoulin, Louis;
Etchegoyen, Alberto;
Fasciszewski, Adrián;
Franceschet, Cristian;
Lerena, Martin Miguel Gamboa;
Garcia, Beatriz;
Garrido, Xavier;
Gaspard, Michel;
Gault, Amanda;
Gayer, Donnacha;
Gervasi, Massimo;
Giard, Martin;
Héraud, Yannick Giraud;
Berisso, Mariano Gómez;
González, Manuel;
Gradziel, Marcin;
Grandsire, Laurent;
Guerard, Eric;
Hamilton, Jean Christophe;
Harari, Diego;
Haynes, Vic;
Versillé, Sophie Henrot;
Hoang, Duc Thuong;
Holtzer, Nicolas;
Incardona, Federico;
Jules, Eric;
Kaplan, Jean;
Korotkov, Andrei;
Kristukat, Christian;
Lamagna, Luca;
Loucatos, Soutiris;
Lowitz, Amy;
Lukovic, Vladimir;
Thibault, Louis;
Luterstein, Raùl Horacio;
Maffei, Bruno;
Marnieros, Stefanos;
Masi, Silvia;
Mattei, Angelo;
May, Andrew;
McCulloch, Mark;
Medina, Maria C.;
Mele, Lorenzo;
Melhuish, Simon J.;
Montier, Ludovic;
Mousset, Louise;
Mundo, Luis Mariano;
Murphy, John Anthony;
Murphy, James;
O'Sullivan, Creidhe;
Olivieri, Emiliano;
Paiella, Alessandro;
Pajot, Francois;
Passerini, Andrea;
Pastoriza, Hernan;
Pelosi, Alessandro;
Perbost, Camille;
Perciballi, Maurizio;
Pezzotta, Federico;
Piacentini, Francesco;
Piat, Michel;
Piccirillo, Lucio;
Pisano, Giampaolo;
Polenta, Gianluca;
Prêle, Damien;
Puddu, Roberto;
Rambaud, Damien;
Ringegni, Pablo;
Romero, Gustavo E.;
Salatino, Maria;
Schillaci, Alessandro;
Scóccola, Claudia G.;
Scully, Stephen P.;
Spinelli, Sebastiano;
Stolpovskiy, Michail;
Suarez, Federico;
Stankowiak, Guillaume;
Tartari, Andrea;
Thermeau, Jean Pierre;
Timbie, Peter;
Tomasi, Maurizio;
Torchinsky, Steve A.;
Tristram, Mathieu;
Tucker, Gregory S.;
Tucker, Carole E.;
Vanneste, Sylvain;
Viganò, Daniele;
Vittorio, Nicola;
Voisin, Fabrice;
Watson, Robert;
Wicek, Francois;
Zannoni, Mario;
Zullo, Antonio
Submitted: 2018-11-30, last modified: 2019-01-23
In this paper we describe QUBIC, an experiment that will observe the
polarized microwave sky with a novel approach, which combines the sensitivity
of state-of-the art bolometric detectors with the systematic effects control
typical of interferometers. QUBIC unique features are the so-called
"self-calibration", a technique that allows us to clean the measured data from
instrumental effects, and its spectral imaging power, i.e. the ability to
separate the signal in various sub-bands within each frequency band. QUBIC will
observe the sky in two main frequency bands: 150 GHz and 220 GHz. A
technological demonstrator is currently under testing and will be deployed in
Argentina during 2019, while the final instrument is expected to be installed
during 2020.
[6]
oai:arXiv.org:1812.03687 [pdf] - 1795038
The STRIP instrument of the Large Scale Polarization Explorer: microwave
eyes to map the Galactic polarized foregrounds
Franceschet, C.;
Realini, S.;
Mennella, A.;
Addamo, G.;
Baù, A.;
Battaglia, P. M.;
Bersanelli, M.;
Caccianiga, B.;
Caprioli, S.;
Cavaliere, F.;
Cleary, K. A.;
Cuttaia, F.;
Del Torto, F.;
Fafone, V.;
Farooqui, Z.;
Santos, R. T. Génova;
Gaier, T. C.;
Gervasi, M.;
Ghigna, T.;
Incardona, F.;
Iovenitti, S.;
Jones, M.;
Kangaslahti, P.;
Mainini, R.;
Maino, D.;
Maris, M.;
Mena, P.;
Molina, R.;
Morgante, G.;
Passerini, A.;
Perez-de-Taoro, M.;
Peverini, O. A.;
Pezzotta, F.;
Pincella, C.;
Reyes, N.;
Rocchi, A.;
Rubiño-Martín, J. A.;
Sandri, M.;
Sartor, S.;
Soria, M.;
Tapia, V.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Viganó, D. M.;
Villa, F.;
Virone, G.;
Volpe, A.;
Watkins, B.;
Zacchei, A.;
Zannoni, M.
Submitted: 2018-12-10
In this paper we discuss the latest developments of the STRIP instrument of
the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel
project that combines ground-based (STRIP) and balloon-borne (SWIPE)
polarization measurements of the microwave sky on large angular scales to
attempt a detection of the "B-modes" of the Cosmic Microwave Background
polarization. STRIP will observe approximately 25% of the Northern sky from the
"Observatorio del Teide" in Tenerife, using an array of forty-nine coherent
polarimeters at 43 GHz, coupled to a 1.5 m fully rotating crossed-Dragone
telescope. A second frequency channel with six-elements at 95 GHz will be
exploited as an atmospheric monitor. At present, most of the hardware of the
STRIP instrument has been developed and tested at sub-system level.
System-level characterization, starting in July 2018, will lead STRIP to be
shipped and installed at the observation site within the end of the year. The
on-site verification and calibration of the whole instrument will prepare STRIP
for a 2-years campaign for the observation of the CMB polarization.
[7]
oai:arXiv.org:1811.02296 [pdf] - 1779826
Thermal architecture for the QUBIC cryogenic receiver
May, A. J.;
Chapron, C.;
Coppi, G.;
D'Alessandro, G.;
de Bernardis, P.;
Masi, S.;
Melhuish, S.;
Piat, M.;
Piccirillo, L.;
Schillaci, A.;
Thermeau, J. -P.;
Ade, P.;
Amico, G.;
Auguste, D.;
Aumont, J.;
Banfi, S.;
Barbara, G.;
Battaglia, P.;
Battistelli, E.;
Bau, A.;
Belier, B.;
Bennett, D.;
Berge, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bordier, G.;
Breelle, E.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Garcia, B.;
Garrido, X.;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Giraud-Heraud, Y.;
Berisso, M. Gomez;
Gonzalez, M.;
Gradziel, M.;
Grandsire, L.;
Guerrard, E.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versille, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Lowitz, A.;
Lukovic, V.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Mattei, A.;
McCulloch, M. A.;
Medina, M. C.;
Mele, L.;
Mennella, A.;
Montier, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
O'Sullivan, C.;
Olivieri, E.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Pezzotta, F.;
Piacentini, F.;
Pisano, G.;
Polenta, G.;
Prele, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Scoccola, C. G.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S. A.;
Tristram, M.;
Truongcanh, V.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Vigano, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-11-06
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming
instrument to measure the B-mode polarization anisotropy of the Cosmic
Microwave Background. The detection of the B-mode signal will be extremely
challenging; QUBIC has been designed to address this with a novel approach,
namely bolometric interferometry. The receiver cryostat is exceptionally large
and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK
using two pulse tube coolers, a novel 4He sorption cooler and a double-stage
3He/4He sorption cooler. We discuss the thermal and mechanical design of the
cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
[8]
oai:arXiv.org:1801.03730 [pdf] - 1616675
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to
look at the polarized Cosmic Microwave Background
Mennella, A.;
Ade, P. A. R.;
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Burke, D. P.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Incardona, F.;
Kaplan, J.;
Korotkov, A.;
Krachmalnicoff, N.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Préle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-01-11
In this paper we describe QUBIC, an experiment that takes up the challenge
posed by the detection of primordial gravitational waves with a novel approach,
that combines the sensitivity of state-of-the art bolometric detectors with the
systematic effects control typical of interferometers. The so-called
"self-calibration" is a technique deeply rooted in the interferometric nature
of the instrument and allows us to clean the measured data from instrumental
effects. The first module of QUBIC is a dual band instrument (150 GHz and 220
GHz) that will be deployed in Argentina during the Fall 2018.
[9]
oai:arXiv.org:1609.04372 [pdf] - 1576378
QUBIC Technical Design Report
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tristram, M.;
Tucker, G.;
Viganò, D.;
Vittori, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2016-09-14, last modified: 2017-05-11
QUBIC is an instrument aiming at measuring the B mode polarisation
anisotropies at medium scales angular scales (30-200 multipoles). The search
for the primordial CMB B-mode polarization signal is challenging, because of
many difficulties: smallness of the expected signal, instrumental systematics
that could possibly induce polarization leakage from the large E signal into B,
brighter than anticipated polarized foregrounds (dust) reducing to zero the
initial hope of finding sky regions clean enough to have a direct primordial
B-modes observation. The QUBIC instrument is designed to address all aspects of
this challenge with a novel kind of instrument, a Bolometric Interferometer,
combining the background-limited sensitivity of Transition-Edge-Sensors and the
control of systematics allowed by the observation of interference fringe
patterns, while operating at two frequencies to disentangle polarized
foregrounds from primordial B mode polarization. Its characteristics are
described in details in this Technological Design Report.
[10]
oai:arXiv.org:1307.5701 [pdf] - 1172881
Latest Progress on the QUBIC Instrument
Ghribi, A.;
Aumont, J.;
Battistelli, E. S.;
Bau, A.;
Bergé, L.;
Bernard, J-Ph.;
Bersanelli, M.;
Bigot-Sazy, M-A.;
Bordier, G.;
Bunn, E. T.;
Cavaliere, F.;
Chanial, P.;
Coppolecchia, A.;
Decourcelle, T.;
De Bernardis, P.;
De Petris, M.;
Drilien, A-A.;
Dumoulin, L.;
Falvella, M. C.;
Gault, A.;
Gervasi, M.;
Giard, M.;
Gradziel, M.;
Grandsire, L.;
Gayer, D.;
Hamilton, J-Ch.;
Haynes, V.;
Giraud-Héraud, Y.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lande, J.;
Lowitz, A.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Ng, M. W.;
Olivieri, E.;
Pajot, F.;
Passerini, A.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Rambaud, D.;
Rigaut, O.;
Rosset, C.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
O'Sullivan, C.;
Tartari, A.;
Timbie, P.;
Tucker, G.;
Vibert, L.;
Voisin, F.;
Watson, B.;
Zannoni, M.
Submitted: 2013-07-22, last modified: 2013-11-12
QUBIC is a unique instrument that crosses the barriers between classical
imaging architectures and interferometry taking advantage from both for high
sensitivity and systematics mitigation. The scientific target is the detection
of the primordial gravitational waves imprint on the Cosmic Microwave
Background which are the proof of inflation, holy grail of modern cosmology. In
this paper, we show the latest advances in the development of the architecture
and the sub-systems of the first module of this instrument to be deployed in
Dome Charlie Concordia base - Antarctica in 2015.
[11]
oai:arXiv.org:1307.6090 [pdf] - 715531
An improved upper limit to the CMB circular polarization at large
angular scales
Mainini, R.;
Minelli, D.;
Gervasi, M.;
Boella, G.;
Sironi, G.;
Bau', A.;
Banfi, S.;
Passerini, A.;
De Lucia, A.;
Cavaliere, F.
Submitted: 2013-07-23, last modified: 2013-09-04
Circular polarization of the Cosmic Microwave Background (CMB) offers the
possibility of detecting rotations of the universe and magnetic fields in the
primeval universe or in distant clusters of galaxies. We used the Milano
Polarimeter (MIPOL) installed at the Testa Grigia Observatory, on the italian
Alps, to improve the existing upper limits to the CMB circular polarization at
large angular scales. We obtain 95% confidence level upper limits to the degree
of the CMB circular polarization ranging between 5.0x10^{-4} and 0.7x10^{-4} at
angular scales between 8 and 24 deg, improving by one order of magnitude
preexisting upper limits at large angular scales. Our results are still far
from the nK region where today expectations place the amplitude of the V Stokes
parameter used to characterize circular polarization of the CMB but improve the
preexisting limit at similar angular scales. Our observations offered also the
opportunity of characterizing the atmospheric emission at 33 GHz at the Testa
Grigia Observatory.
[12]
oai:arXiv.org:1208.0164 [pdf] - 1150428
A coherent polarimeter array for the Large Scale Polarization Explorer
balloon experiment
Bersanelli, M.;
Mennella, A.;
Morgante, G.;
Zannoni, M.;
Addamo, G.;
Baschirotto, A.;
Battaglia, P.;
Baù, A.;
Cappellini, B.;
Cavaliere, F.;
Cuttaia, F.;
Del Torto, F.;
Donzelli, S.;
Farooqui, Z.;
Frailis, M.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gervasi, M.;
Gregorio, A.;
Kangaslahti, P.;
Krachmalnicoff, N.;
Lawrence, C.;
Maggio, G.;
Mainini, R.;
Maino, D.;
Mandolesi, N.;
Paroli, B.;
Passerini, A.;
Peverini, O. A.;
Poli, S.;
Ricciardi, S.;
Rossetti, M.;
Sandri, M.;
Seiffert, M.;
Stringhetti, L.;
Tartari, A.;
Tascone, R.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Villa, F.;
Virone, G.;
Zacchei, A.
Submitted: 2012-08-01
We discuss the design and expected performance of STRIP (STRatospheric
Italian Polarimeter), an array of coherent receivers designed to fly on board
the LSPE (Large Scale Polarization Explorer) balloon experiment. The STRIP
focal plane array comprises 49 elements in Q band and 7 elements in W-band
using cryogenic HEMT low noise amplifiers and high performance waveguide
components. In operation, the array will be cooled to 20 K and placed in the
focal plane of a $\sim 0.6$ meter telescope providing an angular resolution of
$\sim1.5$ degrees. The LSPE experiment aims at large scale, high sensitivity
measurements of CMB polarization, with multi-frequency deep measurements to
optimize component separation. The STRIP Q-band channel is crucial to
accurately measure and remove the synchrotron polarized component, while the
W-band channel, together with a bolometric channel at the same frequency,
provides a crucial cross-check for systematic effects.
[13]
oai:arXiv.org:1208.0281 [pdf] - 544717
The Large-Scale Polarization Explorer (LSPE)
The LSPE collaboration;
Aiola, S.;
Amico, G.;
Battaglia, P.;
Battistelli, E.;
Baù, A.;
de Bernardis, P.;
Bersanelli, M.;
Boscaleri, A.;
Cavaliere, F.;
Coppolecchia, A.;
Cruciani, A.;
Cuttaia, F.;
Addabbo, A. D';
D'Alessandro, G.;
De Gregori, S.;
Del Torto, F.;
De Petris, M.;
Fiorineschi, L.;
Franceschet, C.;
Franceschi, E.;
Gervasi, M.;
Goldie, D.;
Gregorio, A.;
Haynes, V.;
Krachmalnicoff, N.;
Lamagna, L.;
Maffei, B.;
Maino, D.;
Masi, S.;
Mennella, A.;
Wah, Ng Ming;
Morgante, G.;
Nati, F.;
Pagano, L.;
Passerini, A.;
Peverini, O.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Ricciardi, S.;
Rissone, P.;
Romeo, G.;
Salatino, M.;
Sandri, M.;
Schillaci, A.;
Stringhetti, L.;
Tartari, A.;
Tascone, R.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Villa, F.;
Virone, G.;
Withington, S.;
Zacchei, A.;
Zannoni, M.
Submitted: 2012-08-01
The LSPE is a balloon-borne mission aimed at measuring the polarization of
the Cosmic Microwave Background (CMB) at large angular scales, and in
particular to constrain the curl component of CMB polarization (B-modes)
produced by tensor perturbations generated during cosmic inflation, in the very
early universe. Its primary target is to improve the limit on the ratio of
tensor to scalar perturbations amplitudes down to r = 0.03, at 99.7%
confidence. A second target is to produce wide maps of foreground polarization
generated in our Galaxy by synchrotron emission and interstellar dust emission.
These will be important to map Galactic magnetic fields and to study the
properties of ionized gas and of diffuse interstellar dust in our Galaxy. The
mission is optimized for large angular scales, with coarse angular resolution
(around 1.5 degrees FWHM), and wide sky coverage (25% of the sky). The payload
will fly in a circumpolar long duration balloon mission during the polar night.
Using the Earth as a giant solar shield, the instrument will spin in azimuth,
observing a large fraction of the northern sky. The payload will host two
instruments. An array of coherent polarimeters using cryogenic HEMT amplifiers
will survey the sky at 43 and 90 GHz. An array of bolometric polarimeters,
using large throughput multi-mode bolometers and rotating Half Wave Plates
(HWP), will survey the same sky region in three bands at 95, 145 and 245 GHz.
The wide frequency coverage will allow optimal control of the polarized
foregrounds, with comparable angular resolution at all frequencies.
[14]
oai:arXiv.org:1203.5615 [pdf] - 1117549
Intensity and polarization of the atmospheric emission at millimetric
wavelengths at Dome Concordia
Battistelli, E. S.;
Amico, G.;
Baù, A.;
Bergé, L.;
Bréelle, É.;
Charlassier, R.;
Collin, S.;
Cruciani, A.;
de Bernardis, P.;
Dufour, C.;
Dumoulin, L.;
Gervasi, M.;
Giard, M.;
Giordano, C.;
Giraud-Héraud, Y.;
Guglielmi, L.;
Hamilton, J. -C.;
Landé, J.;
Maffei, B.;
Maiello, M.;
Marnieros, S.;
Masi, S.;
Passerini, A.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Polenta, G.;
Rosset, C.;
Salatino, M.;
Schillaci, A.;
Sordini, R.;
Spinelli, S.;
Tartari, A.;
Zannoni, M.
Submitted: 2012-03-26, last modified: 2012-04-20
Atmospheric emission is a dominant source of disturbance in ground-based
astronomy at mm wavelengths. The Antarctic plateau is recognized to be an ideal
site for mm and sub-mm observations, and the French/Italian base of Dome C is
among the best sites on Earth for these observations. In this paper we present
measurements, performed using the BRAIN-pathfinder experiment, at Dome C of the
atmospheric emission in intensity and polarization at 150GHz, one of the best
observational frequencies for CMB observations when considering cosmic signal
intensity, atmospheric transmission, detectors sensitivity, and foreground
removal. Careful characterization of the air-mass synchronous emission has been
performed, acquiring more that 380 elevation scans (i.e. "skydip") during the
third BRAIN-pathfinder summer campaign in December 2009/January 2010. The
extremely high transparency of the Antarctic atmosphere over Dome Concordia is
proven by the very low measured optical depth: <tau_I>=0.050 \pm 0.003 \pm
0.011 where the first error is statistical and the second is systematic error.
Mid term stability, over the summer campaign, of the atmosphere emission has
also been studied. Adapting the radiative transfer atmosphere emission model
"am" to the particular conditions found at Dome C, we also infer the level of
the PWV content of the atmosphere, notoriously the main source of disturbance
in millimetric astronomy (<PWV>=0.77 +/- 0.06 + 0.15 - 0.12 mm). Upper limits
on the air-mass correlated polarized signal are also placed for the first time.
The degree of circular polarization of atmospheric emission is found to be
lower than 0.2% (95%CL), while the degree of linear polarization is found to be
lower than 0.1% (95%CL). These limits include signal-correlated instrumental
spurious polarization.
[15]
oai:arXiv.org:1010.0645 [pdf] - 1041046
QUBIC: The QU Bolometric Interferometer for Cosmology
The QUBIC collaboration;
Battistelli, E.;
Baù, A.;
Bennett, D.;
Bergé, L.;
Bernard, J. -Ph.;
de Bernardis, P.;
Bounab, A.;
Bréelle, É.;
Bunn, E. F.;
Calvo, M.;
Charlassier, R.;
Collin, S.;
Cruciani, A.;
Curran, G.;
Dumoulin, L.;
Gault, A.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giordano, C.;
Giraud-Héraud, Y.;
Gradziel, M.;
Guglielmi, L.;
Hamilton, J. -Ch.;
Haynes, V.;
Kaplan, J.;
Korotkov, A.;
Landé, J.;
Maffei, B.;
Maiello, M.;
Malu, S.;
Marnieros, S.;
Masi, S.;
Murphy, A.;
Nati, F.;
O'Sullivan, C.;
Pajot, F.;
Passerini, A.;
Peterzen, S.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Polenta, G.;
Prêle, D.;
Romano, D.;
Rosset, C.;
Salatino, M.;
Schillacci, A.;
Sironi, G.;
Sordini, R.;
Spinelli, S.;
Tartari, A.;
Timbie, P.;
Tucker, G.;
Vibert, L.;
Voisin, F.;
Watson, R. A.;
Zannoni, M.
Submitted: 2010-10-04
One of the major challenges of modern cosmology is the detection of B-mode
polarization anisotropies in the CMB. These originate from tensor fluctuations
of the metric produced during the inflationary phase. Their detection would
therefore constitute a major step towards understanding the primordial
Universe. The expected level of these anisotropies is however so small that it
requires a new generation of instruments with high sensitivity and extremely
good control of systematic effects. We propose the QUBIC instrument based on
the novel concept of bolometric interferometry, bringing together the
sensitivity advantages of bolometric detectors with the systematics effects
advantages of interferometry. Methods: The instrument will directly observe the
sky through an array of entry horns whose signals will be combined together
using an optical combiner. The whole set-up is located inside a cryostat.
Polarization modulation will be achieved using a rotating half-wave plate and
interference fringes will be imaged on two focal planes (separated by a
polarizing grid) tiled with bolometers. We show that QUBIC can be considered as
a synthetic imager, exactly similar to a usual imager but with a synthesized
beam formed by the array of entry horns. Scanning the sky provides an
additional modulation of the signal and improve the sky coverage shape. The
usual techniques of map-making and power spectrum estimation can then be
applied. We show that the sensitivity of such an instrument is comparable with
that of an imager with the same number of horns. We anticipate a low level of
beam-related systematics thanks to the fact that the synthesized beam is
determined by the location of the primary horns. Other systematics should be
under good control thanks to an autocalibration technique, specific to our
concept, that will permit the accurate determination of most of the systematics
parameters.
[16]
oai:arXiv.org:0806.1415 [pdf] - 900317
TRIS I: Absolute Measurements of the Sky Brightness Temperature at 0.6,
0.82 and 2.5 GHz
Submitted: 2008-06-09
At frequencies close to 1 GHz the sky diffuse radiation is a superposition of
radiation of Galactic origin, the 3 K Relic or Cosmic Microwave Background
Radiation, and the signal produced by unresolved extragalactic sources. Because
of their different origin and space distribution the relative importance of the
three components varies with frequency and depends on the direction of
observation. With the aim of disentangling the components we built TRIS, a
system of three radiometers, and studied the temperature of the sky at $\nu
=0.6$, $\nu = 0.82$ and $\nu = 2.5$ GHz using geometrically scaled antennas
with identical beams (HPBW = $18^{\circ} \times 23^{\circ}$). Observations
included drift scans along a circle at constant declination
$\delta=+42^{\circ}$ which provided the dependence of the sky signal on the
Right Ascension, and absolute measurement of the sky temperature at selected
points along the same scan circle. TRIS was installed at Campo Imperatore (lat.
= $42^{\circ}~26'$ N, long.= $13^{\circ}~33'$, elevation = 2000 m a.s.l.) in
Central Italy, close to the Gran Sasso Laboratory.
[17]
oai:arXiv.org:astro-ph/0307166 [pdf] - 57879
Sunyaev Zel`dovich effect studies with MASTER
Submitted: 2003-07-09
Our three frequencies radiometer MASTER which allows low noise observations
in three frequency intervals around 90, 220 and 345 GHz is being completed. We
discuss the possibility of exploiting the MASTER`s charachteristics for studies
of the Sunyaev Zel`dovich effect from the Antarctic Plateau and propose an
observational program from Dome C
[18]
oai:arXiv.org:astro-ph/0301350 [pdf] - 54321
A dual output polarimeter devoted to the study of the Cosmic Microwave
Background
Submitted: 2003-01-17, last modified: 2003-01-21
We have developed a correlation radiometer at 33 GHz devoted to the search
for residual polarization of the Cosmic Microwave Background (CMB). The two
instruments`s outputs are linear combination of two Stokes Parameters (Q and U
or U and V). The instrument is therefore directly sensitive to the polarized
component of the radiation (respectively linear and circular). The radiometer
has a beam-width oif 7 or 14 deg, but it can be coupled to a telescope
increasing the resolution. The expected CMB polarization is at most a part per
milion. The polarimeter has been designed to be sensitive to this faint signal,
and it has been optimized to improve its long term stability, observing from
the ground. In this contribution the performances of the instrument are
presented, together with the preliminary test and observations.
[19]
oai:arXiv.org:astro-ph/0301354 [pdf] - 54325
Search for distortions in the spectrum of the Cosmic Microwave Radiation
Submitted: 2003-01-17
We present preliminary results of TRIS, an experiment dedicated to the search
of deviations from a pure planckian distribution in the spectrum of the Cosmic
Microwave Background at frequencies close to 1 GHz