Normalized to: Pascua, R.
[1]
oai:arXiv.org:2003.08399 [pdf] - 2067038
Redundant-Baseline Calibration of the Hydrogen Epoch of Reionization
Array
Dillon, Joshua S.;
Lee, Max;
Ali, Zaki S.;
Parsons, Aaron R.;
Orosz, Naomi;
Nunhokee, Chuneeta Devi;
La Plante, Paul;
Beardsley, Adam P.;
Kern, Nicholas S.;
Abdurashidova, Zara;
Aguirre, James E.;
Alexander, Paul;
Balfour, Yanga;
Bernardi, Gianni;
Billings, Tashalee S.;
Bowman, Judd D.;
Bradley, Richard F.;
Bull, Phil;
Burba, Jacob;
Carey, Steve;
Carilli, Chris L.;
Cheng, Carina;
DeBoer, David R.;
Dexter, Matt;
Acedo, Eloy de Lera;
Ely, John;
Ewall-Wice, Aaron;
Fagnoni, Nicolas;
Fritz, Randall;
Furlanetto, Steven R.;
Gale-Sides, Kingsley;
Glendenning, Brian;
Gorthi, Deepthi;
Greig, Bradley;
Grobbelaar, Jasper;
Halday, Ziyaad;
Hazelton, Bryna J.;
Hewitt, Jacqueline N.;
Hickish, Jack;
Jacobs, Daniel C.;
Julius, Austin;
Kerrigan, Joshua;
Kittiwisit, Piyanat;
Kohn, Saul A.;
Kolopanis, Matthew;
Lanman, Adam;
Lekalake, Telalo;
Lewis, David;
Liu, Adrian;
Ma, Yin-Zhe;
MacMahon, David;
Malan, Lourence;
Malgas, Cresshim;
Maree, Matthys;
Martinot, Zachary E.;
Matsetela, Eunice;
Mesinger, Andrei;
Molewa, Mathakane;
Morales, Miguel F.;
Mosiane, Tshegofalang;
Murray, Steven;
Neben, Abraham R.;
Nikolic, Bojan;
Pascua, Robert;
Patra, Nipanjana;
Pieterse, Samantha;
Pober, Jonathan C.;
Razavi-Ghods, Nima;
Ringuette, Jon;
Robnett, James;
Rosie, Kathryn;
Santos, Mario G.;
Sims, Peter;
Smith, Craig;
Syce, Angelo;
Tegmark, Max;
Thyagarajan, Nithyanandan;
Williams, Peter K. G.;
Zheng, Haoxuan
Submitted: 2020-03-18
In 21 cm cosmology, precision calibration is key to the separation of the
neutral hydrogen signal from bright astrophysical foregrounds. If not properly
calibrated, each antenna element's complex gain can impart spectral structure
on otherwise spectrally-smooth foregrounds, complicating that statistical
separation. The Hydrogen Epoch of Reionization Array (HERA), an interferometer
specialized for 21 cm cosmology and now under construction in South Africa, was
designed to be largely calibrated using the self-consistency of repeated
measurements of the same interferometric modes. This technique, known as
redundant-baseline calibration resolves most of the internal degrees of freedom
in the calibration problem. It assumes, however, on antenna elements with
identical primary beams placed precisely on a redundant grid. In this work, we
review the detailed implementation of the algorithms enabling
redundant-baseline calibration and report results with HERA data. We quantify
the effects of real-world non-redundancy and how they compare to the idealized
scenario in which redundant measurements differ only in their noise
realizations. Finally, we study how non-redundancy can produce spurious
temporal structure in our calibration solutions---both in data and in
simulations---and present strategies for mitigating that structure.