Normalized to: Pascal, S.
[1]
oai:arXiv.org:1905.00433 [pdf] - 1877417
FIREBall-2: advancing TRL while doing proof-of-concept astrophysics on a
suborbital platform
Hamden, Erika T.;
Hoadley, Keri;
Martin, D. Christopher;
Schiminovich, David;
Milliard, Bruno;
Nikzad, Shouleh;
Augustin, Ramona;
Balard, Philippe;
Blanchard, Patrick;
Bray, Nicolas;
Crabill, Marty;
Evrard, Jean;
Gomes, Albert;
Grange, Robert;
Gross, Julia;
Jewell, April;
Kyne, Gillian;
Limon, Michele;
Lingner, Nicole;
Matuszewski, Mateusz;
Melso, Nicole;
Mirc, Frederi;
Montel, Johan;
Ong, Hwei Ru;
O'Sullivan, Donal;
Pascal, Sandrine;
Perot, Etienne;
Picouet, Vincent;
Saccoccio, Muriel;
Smiley, Brian;
Soors, Xavier;
Tapie, Pierre;
Vibert, Didier;
Zenone, Isabelle;
Zorilla, Jose
Submitted: 2019-05-01, last modified: 2019-05-03
Here we discuss advances in UV technology over the last decade, with an
emphasis on photon counting, low noise, high efficiency detectors in
sub-orbital programs. We focus on the use of innovative UV detectors in a NASA
astrophysics balloon telescope, FIREBall-2, which successfully flew in the Fall
of 2018. The FIREBall-2 telescope is designed to make observations of distant
galaxies to understand more about how they evolve by looking for diffuse
hydrogen in the galactic halo. The payload utilizes a 1.0-meter class telescope
with an ultraviolet multi-object spectrograph and is a joint collaboration
between Caltech, JPL, LAM, CNES, Columbia, the University of Arizona, and NASA.
The improved detector technology that was tested on FIREBall-2 can be applied
to any UV mission. We discuss the results of the flight and detector
performance. We will also discuss the utility of sub-orbital platforms (both
balloon payloads and rockets) for testing new technologies and proof-of-concept
scientific ideas
[2]
oai:arXiv.org:1903.02218 [pdf] - 1869841
Multi Object Spectrograph of the Fireball-II Balloon Experiment
Submitted: 2019-03-06
Fireball-II is a NASA/CNES balloon-borne telescope and MOS to study faint
diffuse emissions of galaxies in the space ultraviolet. The MOS is based on two
identical reflective Schmidt systems sharing an plane-aspherized grating
obtained by active optics methods.
[3]
oai:arXiv.org:1807.00073 [pdf] - 1708624
Opto-mechanical designs for the HARMONI Adaptive Optics systems
Dohlen, Kjetil;
Morris, Timothy;
Lopez, Javier Piqueras;
Calcines-Rosario, Ariadna;
Costille, Anne;
Dubbeldam, Marc;
Hadi, Kacem El;
Fusco, Thierry;
Llored, Marc;
Neichel, Benoit;
Pascal, Sandrine;
Sauvage, Jean-Francois;
Vola, Pascal;
Clarke, Fraser;
Schnetler, Hermine;
Bryson, Ian;
Thatte, Niranjan
Submitted: 2018-06-29
HARMONI is a visible and near-infrared integral field spectrograph equipped
with two complementary adaptive optics systems, fully integrated within the
instrument. A Single Conjugate AO (SCAO) system offers high performance for a
limited sky coverage and a Laser Tomographic AO (LTAO) system provides AO
correction with a very high sky-coverage. While the deformable mirror
performing real-time correction of the atmospheric disturbances is located
within the telescope itself, the instrument contains a suite of
state-of-the-art and innovative wavefront sensor systems. Laser guide star
sensors (LGSS) are located at the entrance of the instrument and fed by a
dichroic beam splitter, while the various natural guide star sensors for LTAO
and SCAO are located close to the science focal plane. We present
opto-mechanical architecture and design at PDR level for these wavefront sensor
systems.
[4]
oai:arXiv.org:1805.11931 [pdf] - 1691645
The adaptive optics modes for HARMONI: from Classical to Laser Assisted
Tomographic AO
Neichel, B.;
Fusco, T.;
Sauvage, J. -F.;
Correia, C.;
Dohlen, K.;
El-Hadi, K.;
Blanco, L.;
Schwartz, N.;
Clarke, F.;
Thatte, N.;
Tecza, M.;
Paufique, J.;
Vernet, J.;
Louarn, M. Le;
Hammersley, P.;
Gach, J. -L.;
Pascal, S.;
Vola, P.;
Petit, C.;
Conan, J. -M.;
Carlotti, A.;
Verinaud, C.;
Schnetler, H.;
Bryson, I.;
Morris, T.;
Myers, R.;
Hugot, E.;
Gallie, A.
Submitted: 2018-05-30
HARMONI is a visible and NIR integral field spectrograph, providing the
E-ELT's core spectroscopic capability at first light. HARMONI will work at the
diffraction limit of the E-ELT, thanks to a Classical and a Laser Tomographic
AO system. In this paper, we present the system choices that have been made for
these SCAO and LTAO modules. In particular, we describe the strategy developed
for the different Wave-Front Sensors: pyramid for SCAO, the LGSWFS concept, the
NGSWFS path, and the truth sensor capabilities. We present first potential
implementations. And we asses the first system performance.
[5]
oai:arXiv.org:1608.01287 [pdf] - 1531180
SUBARU prime focus spectrograph: integration, testing and performance
for the first spectrograph
Madec, F.;
Fur, A. Le;
Mignant, D. Le;
Dohlen, K.;
Barrette, R.;
Belhadi, M.;
Pascal, S.;
Smee, S.;
Gunn, J.;
Merrer, J. Le;
Lorred, M.;
Jaquet, M.;
Balard, P.;
Blanchard, P.;
Thao, W.;
Roman, F.;
Lapere, V.;
Gabriel, JF;
Loomis, C.;
Golebiowski, M.;
Hart, M.;
Oliveira, L.;
Oliveira, A.;
Tamura, N.;
Shimono, A.
Submitted: 2016-08-03
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and
Redshifts (SuMIRe) project for Subaru telescope consists in four identical
spectrographs fed by 600 fibers each. Each spectrograph is composed by an
optical entrance unit that creates a collimated beam and distributes the light
to three channels, two visibles and one near infrared. This paper presents the
on-going effort for the tests & integration process for the first spectrograph
channel: we have developed a detailed Assembly Integration and Test (AIT) plan,
as well as the methods, detailed processes and I&T tools. We describe the tools
we designed to assemble the parts and to test the performance of the
spectrograph. We also report on the thermal acceptance tests we performed on
the first visible camera unit. We also report on and discuss the technical
difficulties that did appear during this integration phase. Finally, we detail
the important logistic process that is require to transport the components from
other country to Marseille.
[6]
oai:arXiv.org:1608.01075 [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview,
recent progress, and future perspectives
Tamura, Naoyuki;
Takato, Naruhisa;
Shimono, Atsushi;
Moritani, Yuki;
Yabe, Kiyoto;
Ishizuka, Yuki;
Ueda, Akitoshi;
Kamata, Yukiko;
Aghazarian, Hrand;
Arnouts, Stephane;
Barban, Gabriel;
Barkhouser, Robert H.;
Borges, Renato C.;
Braun, David F.;
Carr, Michael A.;
Chabaud, Pierre-Yves;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chiba, Masashi;
Chou, Richard C. Y.;
Chu, You-Hua;
Cohen, Judith G.;
de Almeida, Rodrigo P.;
de Oliveira, Antonio C.;
de Oliveira, Ligia S.;
Dekany, Richard G.;
Dohlen, Kjetil;
Santos, Jesulino B. dos;
Santos, Leandro H. dos;
Ellis, Richard S.;
Fabricius, Maximilian;
Ferrand, Didier;
Ferreira, Decio;
Golebiowski, Mirek;
Greene, Jenny E.;
Gross, Johannes;
Gunn, James E.;
Hammond, Randolph;
Harding, Albert;
Hart, Murdock;
Heckman, Timothy M.;
Hirata, Christopher M.;
Ho, Paul;
Hope, Stephen C.;
Hovland, Larry;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Ping-Jie;
Jaquet, Marc;
Jing, Yipeng;
Karr, Jennifer;
Kimura, Masahiko;
King, Matthew E.;
Komatsu, Eiichiro;
Brun, Vincent Le;
Fevre, Olivier Le;
Fur, Arnaud Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig P.;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas S.;
de Oliveira, Claudia Mendes;
Minowa, Yosuke;
Morantz, Chaz N.;
Murayama, Hitoshi;
Murray, Graham J.;
Ohyama, Youichi;
Orndorff, Joseph;
Pascal, Sandrine;
Pereira, Jefferson M.;
Reiley, Daniel J.;
Reinecke, Martin;
Ritter, Andreas;
Roberts, Mitsuko;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Sodre, Laerte;
Spergel, David N.;
Steinkraus, Aaron J.;
Strauss, Michael A.;
Surace, Christian;
Suto, Yasushi;
Suzuki, Nao;
Swinbank, John;
Tait, Philip J.;
Takada, Masahiro;
Tamura, Tomonori;
Tanaka, Yoko;
Tresse, Laurence;
Verducci, Orlando;
Vibert, Didier;
Vidal, Clement;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Yan, Chi-Hung;
Yasuda, Naoki
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the
8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed,
optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394
reconfigurable fibers will be distributed over the 1.3 deg field of view. The
spectrograph has been designed with 3 arms of blue, red, and near-infrared
cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure
at a resolution of ~1.6-2.7A. An international collaboration is developing this
instrument under the initiative of Kavli IPMU. The project is now going into
the construction phase aiming at undertaking system integration in 2017-2018
and subsequently carrying out engineering operations in 2018-2019. This article
gives an overview of the instrument, current project status and future paths
forward.
[7]
oai:arXiv.org:1607.06606 [pdf] - 1494767
The FLARE mission: Deep and Wide-field 1-5$\mu$m Imaging and
Spectroscopy for the Early Universe: a proposal for M5 Cosmic Vision call
Submitted: 2016-07-22
FLARE (First Light And Reionization Explorer) is a space mission that will be
submitted to ESA (M5 call). Its primary goal (about 80% of lifetime) is to
identify and study galaxies that dwell in the universe before the end of the
reionization up to about z = 15, a redshift that might not be statistically
reachable for JWST, Euclid and WFIRST. A secondary objective (about 20% of
lifetime) is to survey star formation in the Milky Way.
The strategy selected for FLARE optimizes the science return: imaging and
spectroscopic integral-field observations will be carried out simultaneously on
two parallel focal planes and over very wide instantaneous fields of view.
FLARE will feature an instantaneous field of view of about 0.2 deg$^2$ with
0.2-arcsec pixels and an instantaneous integral-field spectroscopic field of
view of about 1 arcmin$^2$ with R = 500 - 1000 and an angular resolution of
about 0.4 arcsec. To detect first-light galaxies, the imaging and spectroscopic
survey (parallel observations over about 6 years) will reach m$_{AB}$ = 28 and
f$_{\lambda}$ = 10$^{-18}$ erg/cm$^2$/S.
FLARE will help addressing two of ESA's Cosmic Vision themes: a) "How did the
universe originate and what is it made of?" and b) "What are the conditions for
planet formation and the emergence of life?" and more specifically, "From gas
and dust to stars and planets".
FLARE will provide to the ESA community a leading position to statistically
study the early universe after JWST's deep but pin-hole surveys. Moreover, the
instrumental development of wide-field imaging and wide-field integral-field
spectroscopy in space will be a major breakthrough after making them available
on ground-based telescopes.
[8]
oai:arXiv.org:1507.00725 [pdf] - 1241387
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed
optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2015-07-02
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber
spectrograph with 2394 science fibers distributed across a 1.3-deg diameter
field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from
0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously
strengthens its ability to target three main survey programs: cosmology,
galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a
resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available
by simply exchanging dispersers. We highlight some of the technological aspects
of the design. To transform the telescope focal ratio, a broad-band coated
microlens is glued to each fiber tip. A higher transmission fiber is selected
for the longest part of the cable system, optimizing overall throughput; a
fiber with low focal ratio degradation is selected for the fiber-positioner and
fiber-slit components, minimizing the effects of fiber movements and fiber
bending. Fiber positioning will be performed by a positioner consisting of two
stages of piezo-electric rotary motors. The positions of these motors are
measured by taking an image of artificially back-illuminated fibers with the
metrology camera located in the Cassegrain container; the fibers are placed in
the proper location by iteratively measuring and then adjusting the positions
of the motors. Target light reaches one of the four identical fast-Schmidt
spectrograph modules, each with three arms. The PFS project has passed several
project-wide design reviews and is now in the construction phase.
[9]
oai:arXiv.org:1408.3911 [pdf] - 1216350
Optical Design of the SuMIRe PFS Spectrograph
Submitted: 2014-08-18
The SuMIRe Prime Focus Spectrograph (PFS), developed for the 8-m class SUBARU
telescope, will consist of four identical spectrographs, each receiving 600
fibers from a 2394 fiber robotic positioner at the telescope prime focus. Each
spectrograph includes three spectral channels to cover the wavelength range
0.38-1.26 um with a resolving power ranging between 2000 and 4000. A medium
resolution mode is also implemented to reach a resolving power of 5000 at 0.8
um. Each spectrograph is made of 4 optical units: the entrance unit which
produces three corrected collimated beams and three camera units (one per
spectral channel). The beam is split by using two large dichroics; and in each
arm, the light is dispersed by large VPH gratings. The proposed optical design
was optimized to achieve the requested image quality while simplifying the
manufacturing of the whole optical system. The camera design consists in an
innovative Schmidt camera observing a large field-of-view (10 degrees) with a
very fast beam. To achieve such a performance, the classical spherical mirror
is replaced by a catadioptric mirror (i.e meniscus lens with a reflective
surface on the rear side of the glass, like a Mangin mirror). This article
focuses on the optical architecture of the PFS spectrograph and the perfornance
achieved. We will first described the global optical design of the
spectrograph. Then, we will focus on the Mangin-Schmidt camera design. The
analysis of the optical performance and the results obtained are presented in
the last section.
[10]
oai:arXiv.org:1408.2825 [pdf] - 1216260
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a
massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsuc, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber
spectrograph with 2394 science fibers, which are distributed in 1.3 degree
diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide
wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000,
strengthens its ability to target three main survey programs: cosmology,
Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with
resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply
exchanging dispersers. PFS takes the role for the spectroscopic part of the
Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam
works on the imaging part. To transform the telescope plus WFC focal ratio, a
3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip.
A higher transmission fiber is selected for the longest part of cable system,
while one with a better FRD performance is selected for the fiber-positioner
and fiber-slit components, given the more frequent fiber movements and tightly
curved structure. Each Fiber positioner consists of two stages of
piezo-electric rotary motors. Its engineering model has been produced and
tested. Fiber positioning will be performed iteratively by taking an image of
artificially back-illuminated fibers with the Metrology camera located in the
Cassegrain container. The camera is carefully designed so that fiber position
measurements are unaffected by small amounts of high special-frequency
inaccuracies in WFC lens surface shapes. Target light carried through the fiber
system reaches one of four identical fast-Schmidt spectrograph modules, each
with three arms. Prototype VPH gratings have been optically tested. CCD
production is complete, with standard fully-depleted CCDs for red arms and
more-challenging thinner fully-depleted CCDs with blue-optimized coating for
blue arms.
[11]
oai:arXiv.org:1408.2827 [pdf] - 1216261
Current status of the Spectrograph System for the SuMIRe/PFS
Vives, S.;
Mignant, D. Le;
Gunn, J. E.;
Smee, S.;
de Oliveira, L. Souza;
Tamura, N.;
Sugai, H.;
Barkhouser, R.;
Bozier, A.;
Carr, M. A.;
de Oliveira, A. Cesar;
Ferrand, D.;
Golebiowski, M.;
Hart, M.;
Hope, S.;
Jaquet, M.;
Madec, F.;
Pascal, S.;
Pegot-Ogier, T.;
de Arruda, M. Vittal
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is a new facility instrument for Subaru
Telescope which will be installed in around 2017. It is a multi-object
spectrograph fed by about 2400 fibers placed at the prime focus covering a
hexagonal field-of-view with 1.35 deg diagonals and capable of simultaneously
obtaining data of spectra with wavelengths ranging from 0.38 um to 1.26 um. The
spectrograph system is composed of four identical modules each receiving the
light from 600 fibers. Each module incorporates three channels covering the
wavelength ranges 0.38-0.65 mu ("Blue"), 0.63-0.97 mu ("Red"), and 0.94-1.26 mu
("NIR") respectively; with resolving power which progresses fairly smoothly
from about 2000 in the blue to about 4000 in the infrared. An additional
spectral mode allows reaching a spectral resolution of 5000 at 0.8mu (red). The
proposed optical design is based on a Schmidt collimator facing three Schmidt
cameras (one per spectral channel). This architecture is very robust, well
known and documented. It allows for high image quality with only few simple
elements (high throughput) at the expense of the central obscuration, which
leads to larger optics. Each module has to be modular in its design to allow
for integration and tests and for its safe transport up to the telescope: this
is the main driver for the mechanical design. In particular, each module will
be firstly fully integrated and validated at LAM (France) before it is shipped
to Hawaii. All sub-assemblies will be indexed on the bench to allow for their
accurate repositioning. This paper will give an overview of the spectrograph
system which has successfully passed the Critical Design Review (CDR) in 2014
March and which is now in the construction phase.
[12]
oai:arXiv.org:1408.3284 [pdf] - 1216305
The near infrared camera for the Subaru Prime Focus Spectrograph
Smee, Stephen A.;
Gunn, James E.;
Golebiowski, Mirek;
Barkhouser, Robert;
Vives, Sebastien;
Pascal, Sandrine;
Carr, Michael;
Hope, Stephen C.;
Loomis, Craig;
Hart, Murdock;
Sugai, Hajime;
Tamura, Naoyuki;
Shimono, Atsushi
Submitted: 2014-08-12
We present the detailed design of the near infrared camera for the SuMIRe
(Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS)
being developed for the Subaru Telescope. The PFS spectrograph is designed to
collect spectra from 2394 objects simultaneously, covering wavelengths that
extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical
spectrograph modules, with each module collecting roughly 600 spectra from a
robotic fiber positioner at the telescope prime focus. Each spectrograph module
will have two visible channels covering wavelength ranges 380 nm - 640 nm and
640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range
955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal
length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector
format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff
device is used. In the visible channels, CCDs from Hamamatsu are used. These
cameras are large, having a clear aperture of 300 mm at the entrance window,
and a mass of ~ 250 kg.
Like the two visible channel cameras, the NIR camera contains just four
optical elements: a two-element refractive corrector, a Mangin mirror, and a
field flattening lens. This simple design produces very good imaging
performance considering the wide field and wavelength range, and it does so in
large part due to the use of a Mangin mirror (a lens with a reflecting rear
surface) for the Schmidt primary. In the case of the NIR camera, the rear
reflecting surface is a dichroic, which reflects in-band wavelengths and
transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection
filter coating on the rear surface of the second corrector element, greatly
reduces the out-of-band thermal radiation that reaches the detector.
[13]
oai:arXiv.org:0911.1629 [pdf] - 902351
Photometric redshifts for supernovae Ia in the Supernova Legacy Survey
Palanque-Delabrouille, N.;
Ruhlmann-Kleider, V.;
Pascal, S.;
Rich, J.;
Guy, J.;
Bazin, G.;
Astier, P.;
Balland, C.;
Basa, S.;
Carlberg, R. G.;
Conley, A.;
Fouchez, D.;
Hardin, D.;
Hook, I. M.;
Howell, D. A.;
Pain, R.;
Perrett, K.;
Pritchet, C. J.;
Regnault, N.;
Sullivan, M.
Submitted: 2009-11-09, last modified: 2010-06-11
We present a method using the SALT2 light curve fitter to determine the
redshift of Type Ia supernovae in the Supernova Legacy Survey (SNLS) based on
their photometry in g', r', i' and z'. On 289 supernovae of the first three
years of SNLS data, we obtain a precision $\sigma_{\Delta z/(1+z)} = 0.022$ on
average up to a redshift of 1.0, with a higher precision of 0.016 for z<0.45
and a lower one of 0.025 for z>0.45. The rate of events with $|\Delta
z|/(1+z)>0.15$ (catastrophic errors) is 1.4%. Both the precision and the rate
of catastrophic errors are better than what can be currently obtained using
host galaxy photometric redshifts. Photometric redshifts of this precision may
be useful for future experiments which aim to discover up to millions of
supernovae Ia but without spectroscopy for most of them.