Parker, Brad
Normalized to: Parker, B.
2 article(s) in total. 13 co-authors, from 1 to 2 common article(s). Median position in authors list is 7,5.
[1]
oai:arXiv.org:astro-ph/0409085 [pdf] - 67166
Multipixel characterization of imaging CZT detectors for hard X-ray
imaging and spectroscopy
Vadawale, S. V.;
Hong, J.;
Grindlay, J.;
Williams, P.;
Zhang, M.;
Bellm, E.;
Narita, T.;
Craig, W.;
Parker, B.;
Stahle, C.;
Yan, Feng
Submitted: 2004-09-03
We report our in-depth study of Cd-Zn-Te (CZT) crystals to determine an
optimum pixel and guard band configuration for Hard X-ray imaging and
spectroscopy. We tested 20x20x5mm crystals with 8x8 pixels on a 2.46mm pitch.
We have studied different types of cathode / anode contacts and different pixel
pad sizes. We present the measurements of leakage current as well as spectral
response for each pixel. Our I-V measurement setup is custom designed to allow
automated measurements of the I-V curves sequentially for all 64 pixels,
whereas the radiation properties measurement setup allows for interchangeable
crystals with the same XAIM3.2 ASIC readout from IDEAS. We have tested multiple
crystals of each type, and each crystal in different positions to measure the
variation between individual crystals and variation among the ASIC channels. We
also compare the same crystals with and without a grounded guard band deposited
on the crystal side walls vs. a floating guard band and compare results to
simulations. This study was carried out to find the optimum CZT crystal
configuration for prototype detectors for the proposed Black-Hole Finder
mission, EXIST.
[2]
oai:arXiv.org:astro-ph/0211529 [pdf] - 53264
Background Measurements from Balloon-Borne CZT Detectors
Submitted: 2002-11-24, last modified: 2002-12-03
We report detector characteristics and background measurements from two
prototype imaging CZT detectors flown on a scientific balloon payload in May
2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals,
each with a 4 $\times$ 4 array of pixels tiling the anode. One is made from
IMARAD horizontal Bridgman CZT, the other from eV Products high-pressure
Bridgman material. Both detectors were mounted side-by-side in a flip-chip
configuration and read out by a 32-channel IDE VA/TA ASIC preamp/shaper. We
enclosed the detectors in the same 40deg field-of-view collimator (comprisinga
graded passive shield and plastic scintillator) used in our previously-reported
September 2000 flight. I-V curves for the detectors are diode-like, and we find
that the platinum contacts adhere significantly better to the CZT surfaces than
gold to previous detectors. The detectors and instrumentation performed well in
a 20-hour balloon flight on 23/24 May 2001. Although we discovered a
significant instrumental background component in flight, it was possible to
measure and subtract this component from the spectra. The resulting IMARAD
detector background spectrum (from 30 keV to ~450 keV) reaches ~5 x 10^{-3}$
counts/cm^2 -sec-keV at 100 keV and has a power-law index of ~2 at high
energies. The eV Products detector has a similar spectrum, although there is
more uncertainty in the energy scale because of calibration complications.