sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Parker, Brad

Normalized to: Parker, B.

2 article(s) in total. 13 co-authors, from 1 to 2 common article(s). Median position in authors list is 7,5.

[1]  oai:arXiv.org:astro-ph/0409085  [pdf] - 67166
Multipixel characterization of imaging CZT detectors for hard X-ray imaging and spectroscopy
Comments: To appears in the SPIE 2004 proceedings (5540: Hard X-ray and gamma-ray detector physics V)
Submitted: 2004-09-03
We report our in-depth study of Cd-Zn-Te (CZT) crystals to determine an optimum pixel and guard band configuration for Hard X-ray imaging and spectroscopy. We tested 20x20x5mm crystals with 8x8 pixels on a 2.46mm pitch. We have studied different types of cathode / anode contacts and different pixel pad sizes. We present the measurements of leakage current as well as spectral response for each pixel. Our I-V measurement setup is custom designed to allow automated measurements of the I-V curves sequentially for all 64 pixels, whereas the radiation properties measurement setup allows for interchangeable crystals with the same XAIM3.2 ASIC readout from IDEAS. We have tested multiple crystals of each type, and each crystal in different positions to measure the variation between individual crystals and variation among the ASIC channels. We also compare the same crystals with and without a grounded guard band deposited on the crystal side walls vs. a floating guard band and compare results to simulations. This study was carried out to find the optimum CZT crystal configuration for prototype detectors for the proposed Black-Hole Finder mission, EXIST.
[2]  oai:arXiv.org:astro-ph/0211529  [pdf] - 53264
Background Measurements from Balloon-Borne CZT Detectors
Comments: 9 pages, 7 figures (in 8 files). Presented at SPIE, Aug. 2002. To appear in Proc. SPIE, volume 4851. Errors in references and typos in text fixed
Submitted: 2002-11-24, last modified: 2002-12-03
We report detector characteristics and background measurements from two prototype imaging CZT detectors flown on a scientific balloon payload in May 2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals, each with a 4 $\times$ 4 array of pixels tiling the anode. One is made from IMARAD horizontal Bridgman CZT, the other from eV Products high-pressure Bridgman material. Both detectors were mounted side-by-side in a flip-chip configuration and read out by a 32-channel IDE VA/TA ASIC preamp/shaper. We enclosed the detectors in the same 40deg field-of-view collimator (comprisinga graded passive shield and plastic scintillator) used in our previously-reported September 2000 flight. I-V curves for the detectors are diode-like, and we find that the platinum contacts adhere significantly better to the CZT surfaces than gold to previous detectors. The detectors and instrumentation performed well in a 20-hour balloon flight on 23/24 May 2001. Although we discovered a significant instrumental background component in flight, it was possible to measure and subtract this component from the spectra. The resulting IMARAD detector background spectrum (from 30 keV to ~450 keV) reaches ~5 x 10^{-3}$ counts/cm^2 -sec-keV at 100 keV and has a power-law index of ~2 at high energies. The eV Products detector has a similar spectrum, although there is more uncertainty in the energy scale because of calibration complications.