sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Pantic, E.

Normalized to: Pantic, E.

38 article(s) in total. 691 co-authors, from 1 to 31 common article(s). Median position in authors list is 56,5.

[1]  oai:arXiv.org:2004.02024  [pdf] - 2075899
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
The DarkSide collaboration; Aalseth, C. E.; Abdelhakim, S.; Agnes, P.; Ajaj, R.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Amaudruz, P.; Ameli, F.; Anstey, J.; Antonioli, P.; Arba, M.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Arpaia, P.; Asner, D. M.; Asunskis, A.; Ave, M.; Back, H. O.; Barbaryan, V.; Olmedo, A. Barrado; Batignani, G.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Borisova, E.; Bottino, B.; Boulay, M. G.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carnesecchi, F.; Castellani, A.; Castello, P.; Cavalcante, P.; Cavazza, D.; Cavuoti, S.; Cebrian, S.; Ruiz, J. M. Cela; Celano, B.; Cereseto, R.; Chashin, S.; Cheng, W.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Coccetti, F.; Cocco, V.; Colocci, M.; Vidal, E. Conde; Consiglio, L.; Cossio, F.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; Rolo, M. D. Da Rocha; Dadoun, O.; Daniel, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Falco, A.; De Gruttola, D.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Demontis, P.; De Pasquale, S.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Noto, L.; Di Pietro, G.; Di Stefano, P.; Dionisi, C.; Dolganov, G.; Dordei, F.; Downing, M.; Edalatfar, F.; Empl, A.; Diaz, M. Fernandez; Filip, C.; Fiorillo, G.; Fomenko, K.; Franceschi, A.; Franco, D.; Frolov, E.; Froudakis, G. E.; Funicello, N.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Garbini, M.; Abia, P. Garcia; Fora, D. Gascón; Gendotti, A.; Ghiano, C.; Ghisi, A.; Giampa, P.; Giampaolo, R. A.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gorchakov, O.; Grab, M.; Diaz, R. Graciani; Grassi, M.; Grate, J. W.; Grobov, A.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hackett, B. R.; Hallin, A.; Haranczyk, M.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hubaut, F.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ilyasov, A.; Ippolito, V.; Jillings, C.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Kondo, K.; Kopp, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kugathasan, R.; Kuss, M.; La Commara, M.; La Delfa, L.; Lai, M.; Lebois, M.; Lehnert, B.; Levashko, N.; Li, X.; Liqiang, Q.; Lissia, M.; Lodi, G. U.; Longo, G.; Lussana, R.; Luzzi, L.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Manecki, S.; Mapelli, L.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Marinelli, M.; Marras, D.; Martínez, M.; Rojas, A. D. Martinez; Mascia, M.; Mason, J.; Masoni, A.; McDonald, A. B.; Messina, A.; Miletic, T.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Morrocchi, M.; Mroz, T.; Mu, W.; Muratova, V. N.; Murphy, S.; Muscas, C.; Musico, P.; Nania, R.; Napolitano, T.; Agasson, A. Navrer; Nessi, M.; Nikulin, I.; Nosov, V.; Nowak, J. A.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Peeters, S.; Pegoraro, P. A.; Pelczar, K.; Pellegrini, L. A.; Pellegrino, C.; Pelliccia, N.; Perotti, F.; Pesudo, V.; Picciau, E.; Pietropaolo, F.; Pocar, A.; Pollmann, T. R.; Portaluppi, D.; Poudel, S. S.; Pralavorio, P.; Price, D.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Regenfus, C.; Renshaw, A. L.; Rescia, S.; Rescigno, M.; Retiere, F.; Rignanese, L. P.; Ripoli, C.; Rivetti, A.; Rode, J.; Romani, A.; Romero, L.; Rossi, N.; Rubbia, A.; Sala, P.; Salatino, P.; Samoylov, O.; García, E. Sánchez; Sandford, E.; Sanfilippo, S.; Sant, M.; Santone, D.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Siddhanta, S.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Stainforth, R.; Steri, A.; Stracka, S.; Strickland, V.; Suffritti, G. B.; Sulis, S.; Suvorov, Y.; Szelc, A. M.; Tartaglia, R.; Testera, G.; Thorpe, T.; Tonazzo, A.; Tosi, A.; Tuveri, M.; Unzhakov, E. V.; Usai, G.; Vacca, A.; Vázquez-Jáuregui, E.; Viant, T.; Viel, S.; Villa, F.; Vishneva, A.; Vogelaar, R. B.; Wahl, J.; Walding, J. J.; Wang, H.; Wang, Y.; Westerdale, S.; Wheadon, R. J.; Williams, R.; Wilson, J.; Wojcik, Marcin; Wojcik, Mariusz; Wu, S.; Xiao, X.; Yang, C.; Ye, Z.; Zuffa, M.; Zuzel, G.
Comments: 25 pages, 22 figures, 3 tables
Submitted: 2020-04-04
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter search to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition to it, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) range. The first is due to bremsstrahlung of electrons scattered on neutral atoms (so-called neutral bremsstrahlung, NBrS). The second, responsible for electron avalanche scintillations in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a SiPM matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillations effects. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter search. It should be emphasized that this is the first practical application of the NBrS effect in detection science.
[2]  oai:arXiv.org:2001.08106  [pdf] - 2080977
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
The DarkSide Collaboration; Aalseth, C. E.; Abdelhakim, S.; Acerbi, F.; Agnes, P.; Ajaj, R.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Amaudruz, P.; Ameli, F.; Anstey, J.; Antonioli, P.; Arba, M.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Arpaia, P.; Asner, D. M.; Asunskis, A.; Ave, M.; Back, H. O.; Olmedo, A. Barrado; Batignani, G.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Borisova, E.; Bottino, B.; Boulay, M. G.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carnesecchi, F.; Carpinelli, M.; Castellani, A.; Castello, P.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavazza, D.; Cavuoti, S.; Cebrian, S.; Ruiz, J. M. Cela; Celano, B.; Cereseto, R.; Cheng, W.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Cocco, A. G.; Cocco, V.; Colocci, M.; Consiglio, L.; Cossio, F.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; D'Urso, D.; Rolo, M. D. Da Rocha; Dadoun, O.; Daniel, M.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Falco, A.; De Filippis, G.; De Gruttola, D.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Demontis, P.; DePaquale, S.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Noto, L.; Di Pietro, G.; Di Stefano, P.; Dionisi, C.; Dolganov, G.; Dordei, F.; Downing, M.; Edalatfar, F.; Empl, A.; Diaz, M. Fernandez; Ferri, A.; Filip, C.; Fiorillo, G.; Fomenko, K.; Franceschi, A.; Franco, D.; Froudakis, G. E.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Abia, P. Garcia; Fora, D. Gascón; Gendotti, A.; Ghiano, C.; Ghisi, A.; Giagu, S.; Giampa, P.; Giampaolo, R. A.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gola, A.; Gorchakov, O.; Grab, M.; Diaz, R. Graciani; Granato, F.; Grassi, M.; Grate, J. W.; Grigoriev, G. Y.; Grobov, A.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hackett, B. R.; Hallin, A.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hubaut, F.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ilyasov, A.; Ippolito, V.; Jillings, C.; Keeter, K.; Kendziora, C. L.; Kim, S.; Kochanek, I.; Kondo, K.; Kopp, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kugathasan, R.; Kuss, M.; Kuźniak, M.; La Commara, M.; La Delfa, L.; Lai, M.; Langrock, S.; Lebois, M.; Lehnert, B.; Levashko, N.; Li, X.; Liqiang, Q.; Lissia, M.; Lodi, G. U.; Longo, G.; Manzano, R. López; Lussana, R.; Luzzi, L.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Marcante, M.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Marinelli, M.; Marras, D.; Martínez, M.; Morales, J. J. Martínez; Rojas, A. D. Martinez; Martoff, C. J.; Mascia, M.; Mason, J.; Masoni, A.; Mazzi, A.; McDonald, A. B.; Messina, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Morrocchi, M.; Mroz, T.; Mu, W.; Muratova, V. N.; Murphy, S.; Muscas, C.; Musico, P.; Nania, R.; Napolitano, T.; Agasson, A. Navrer; Nessi, M.; Nikulin, I.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Paternoster, G.; Pavletcov, V.; Pazzona, F.; Peeters, S.; Pegoraro, P. A.; Pelczar, K.; Pellegrini, L. A.; Pellegrino, C.; Pelliccia, N.; Perotti, F.; Pesudo, V.; Picciau, E.; Piemonte, C.; Pietropaolo, F.; Pocar, A.; Pollman, T.; Portaluppi, D.; Poudel, S. S.; Pralavorio, P.; Price, D.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Razeto, A.; Regazzoni, V.; Regenfus, C.; Renshaw, A. L.; Rescia, S.; Rescigno, M.; Retiere, F.; Rignanese, L. P.; Rivetti, A.; Romani, A.; Romero, L.; Rossi, N.; Rubbia, A.; Sablone, D.; Sala, P.; Salatino, P.; Samoylov, O.; García, E. Sánchez; Sanfilippo, S.; Sant, M.; Santone, D.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Siddhanta, S.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Stainforth, R.; Steri, A.; Stracka, S.; Strickland, V.; Suffritti, G. B.; Sulis, S.; Suvorov, Y.; Szelc, A. M.; Tartaglia, R.; Testera, G.; Thorpe, T.; Tonazzo, A.; Tosi, A.; Tuveri, M.; Unzhakov, E. V.; Usai, G.; Vacca, A.; Vázquez-Jáuregui, E.; Verducci, M.; Viant, T.; Viel, S.; Villa, F.; Vishneva, A.; Vogelaar, R. B.; Wada, M.; Wahl, J.; Walding, J. J.; Wang, H.; Wang, Y.; Westerdale, S.; Wheadon, R. J.; Williams, R.; Wilson, J.; Wojcik, Marcin; Wojcik, Mariusz; Wu, S.; Xiao, X.; Yang, C.; Ye, Z.; Zuffa, M.; Zuzel, G.
Comments: 13 pages, 8 figures. Corresponding author: E. S\'anchez Garc\'ia
Submitted: 2020-01-22
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $\beta$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $\gamma$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
[3]  oai:arXiv.org:1907.09332  [pdf] - 1998536
Measurement of the ion fraction and mobility of $^{218}$Po produced in $^{222}$Rn decays in liquid argon
Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Ave, M.; Back, H. O.; Batignani, G.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W. M.; Bottino, B.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Caminata, A.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Chepurnov, A.; Cicalo, C.; Cocco, A. G.; Covone, G.; D'Angelo, D.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Rosa, G.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; D'Incecco, M.; Di Pietro, G.; Dionisi, C.; Downing, M.; D'Urso, D.; Edkins, E.; Empl, A.; Fiorillo, G.; Fomenko, K.; Franco, D.; Gabriele, F.; Galbiati, C.; Ghiano, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Grobov, A.; Gromov, M.; Guan, M.; Guardincerri, Y.; Gulino, M.; Hackett, B. R.; Herner, K.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; Ippolito, V.; Johnson, T. N.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; La Commara, M.; Lai, M.; Li, X.; Lissia, M.; Longo, G.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Mari, S. M.; Maricic, J.; Martoff, C. J.; Messina, A.; Meyers, P. D.; Milincic, R.; Monte, A.; Morrocchi, M.; Muratova, V. N.; Musico, P.; Agasson, A. Navrer; Nozdrina, A. O.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pandola, L.; Pantic, E.; Paoloni, E.; Pelczar, K.; Pelliccia, N.; Picciau, E.; Pocar, A.; Pordes, S.; Poudel, S. S.; Qian, H.; Ragusa, F.; Razeti, M.; Razeto, A.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Sablone, D.; Samoylov, O.; Sands, W.; Sanfilippo, S.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Stracka, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, R. B.; Wada, M.; Waldrop, T. J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Zhu, C.; Zuzel, G.
Comments:
Submitted: 2019-07-22, last modified: 2019-10-28
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)$\times$10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
[4]  oai:arXiv.org:1802.07198  [pdf] - 1789406
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
The DarkSide Collaboration; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Araujo, G. R.; Ave, M.; Back, H. O.; Baldin, B.; Batignani, G.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bottino, B.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Caminata, A.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Chepurnov, A.; Cicalò, C.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; D'Urso, D.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Rosa, G.; De Vincenzi, M.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Downing, M.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fitzpatrick, R. S.; Fomenko, K.; Franco, D.; Gabriele, F.; Galbiati, C.; Ghiano, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Gulino, M.; Hackett, B. R.; Herner, K.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ippolito, V.; James, I.; Johnson, T. N.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; La Commara, M.; Lai, M.; Li, X.; Lissia, M.; Longo, G.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Mari, S. M.; Maricic, J.; Martoff, C. J.; Messina, A.; Meyers, P. D.; Milincic, R.; Monte, A.; Morrocchi, M.; Mount, B. J.; Muratova, V. N.; Musico, P.; Agasson, A. Navrer; Nozdrina, A. O.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pandola, L.; Pantic, E.; Paoloni, E.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Poudel, S. S.; Pugachev, D. A.; Qian, H.; Ragusa, F.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Sablone, D.; Samoylov, O.; Sands, W.; Sanfilippo, S.; Savarese, C.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Stracka, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Waldrop, T. J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Zhu, C.; Zuzel, G.
Comments: 17 pages, 13 figures. V3 changes: updates for clarity for publication, additional figure
Submitted: 2018-02-20, last modified: 2018-11-19
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark matter-nucleon spin-independent cross section of 1.14E-44 cm^2 (3.78E-44 cm^2, 3.43E-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10 TeV/c^2).
[5]  oai:arXiv.org:1802.06998  [pdf] - 1760983
Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment
The DarkSide Collaboration; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Araujo, G. R.; Asner, D. M.; Ave, M.; Back, H. O.; Baldin, B.; Batignani, G.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bottino, B.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Caminata, A.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Cereseto, R.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; D'Urso, D.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Rosa, G.; De Vincenzi, M.; Demontis, P.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Downing, M.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Franco, D.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Abia, P. Garcia; Ghiano, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Gulino, M.; Hackett, B. R.; Hassanshahi, M. H.; Herner, K.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; Ippolito, V.; James, I.; Johnson, T. N.; Kahn, Y.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; La Commara, M.; Lai, M.; Li, X.; Lisanti, M.; Lissia, M.; Loer, B.; Longo, G.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Mari, S. M.; Maricic, J.; Martoff, C. J.; Messina, A.; Meyers, P. D.; Milincic, R.; Mishra-Sharma, S.; Monte, A.; Morrocchi, M.; Mount, B. J.; Muratova, V. N.; Musico, P.; Nania, R.; Agasson, A. Navrer; Nozdrina, A. O.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Pelczar, K.; Pelliccia, N.; Pesudo, V.; Picciau, E.; Pocar, A.; Pordes, S.; Poudel, S. S.; Pugachev, D. A.; Qian, H.; Ragusa, F.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Sablone, D.; Samoylov, O.; Sands, W.; Sanfilippo, S.; Sant, M.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Stracka, S.; Suffritti, G. B.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Waldrop, T. J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Wojcik, M.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Zhu, C.; Zichichi, A.; Zuzel, G.
Comments: replaced with published version
Submitted: 2018-02-20, last modified: 2018-10-03
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
[6]  oai:arXiv.org:1802.06994  [pdf] - 1739878
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
The DarkSide Collaboration; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Araujo, G. R.; Asner, D. M.; Ave, M.; Back, H. O.; Baldin, B.; Batignani, G.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bottino, B.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Caminata, A.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Cereseto, R.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; D'Urso, D.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Rosa, G.; De Vincenzi, M.; Demontis, P.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Downing, M.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Franco, D.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Abia, P. Garcia; Ghiano, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Gulino, M.; Hackett, B. R.; Hassanshahi, M. H.; Herner, K.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; Ippolito, V.; James, I.; Johnson, T. N.; Kahn, Y.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; La Commara, M.; Lai, M.; Li, X.; Lisanti, M.; Lissia, M.; Loer, B.; Longo, G.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Mari, S. M.; Maricic, J.; Martoff, C. J.; Messina, A.; Meyers, P. D.; Milincic, R.; Mishra-Sharma, S.; Monte, A.; Morrocchi, M.; Mount, B. J.; Muratova, V. N.; Musico, P.; Nania, R.; Agasson, A. Navrer; Nozdrina, A. O.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Pelczar, K.; Pelliccia, N.; Pesudo, V.; Pocar, A.; Pordes, S.; Poudel, S. S.; Pugachev, D. A.; Qian, H.; Ragusa, F.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Sablone, D.; Samoylov, O.; Sands, W.; Sanfilippo, S.; Sant, M.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Stracka, S.; Suffritti, G. B.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Waldrop, T. J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Wojcik, M.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Zhu, C.; Zichichi, A.; Zuzel, G.
Comments: 9 pages, 8 figures; submission accepted by journal
Submitted: 2018-02-20, last modified: 2018-08-28
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.
[7]  oai:arXiv.org:1404.1455  [pdf] - 1693885
First Axion Results from the XENON100 Experiment
Comments:
Submitted: 2014-04-05, last modified: 2016-12-22
We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been probed by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For axion-like-particles, under the assumption that they constitute the whole abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than $1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set the best limit to date as well.
[8]  oai:arXiv.org:1510.04196  [pdf] - 1457115
Solar neutrino detection in a large volume double-phase liquid argon experiment
Comments: 21 pages, 7 figures, 6 tables
Submitted: 2015-10-14, last modified: 2016-08-01
Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the "neutrino floor" (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ~15% precision, and significantly improve the precision of the 7Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.
[9]  oai:arXiv.org:1510.00702  [pdf] - 1390602
Results from the first use of low radioactivity argon in a dark matter search
The DarkSide Collaboration; Agnes, P.; Agostino, L.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Arisaka, K.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadonati, L.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cocco, A. G.; Covone, G.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Vincenzi, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giganti, C.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; James, I.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Lombardi, P.; Luitz, S.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M.; Mosteiro, P.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Nelson, A.; Odrowski, S.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Perasso, S.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Savarese, C.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smallcomb, M.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xu, J.; Yang, C.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.
Comments: Accepted by Phys. Rev. D
Submitted: 2015-10-02, last modified: 2016-04-13
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
[10]  oai:arXiv.org:1507.07747  [pdf] - 1264865
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
Comments: 4 pages, 4 figures, with supporting online material
Submitted: 2015-07-28
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2 GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4 sigma confidence level, mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
[11]  oai:arXiv.org:1503.07698  [pdf] - 1342737
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
Comments: 10 pages, 5 figures
Submitted: 2015-03-26
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
[12]  oai:arXiv.org:1410.0653  [pdf] - 967593
First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
Agnes, P.; Alexander, T.; Alton, A.; Arisaka, K.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Brigatti, A.; Brodsky, J.; Budano, F.; Cadonati, L.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Cavalcante, P.; Chavarria, A.; Chepurnov, A.; Cocco, A. G.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Deo, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Goretti, A.; Grandi, L.; Gromov, M.; Guan, M. Y.; Guardincerri, Y.; Hackett, B.; Herner, K.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; Jollet, C.; Keeter, K.; Kendziora, C.; Kidner, S.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kurlej, A.; Li, P. X.; Loer, B.; Lombardi, P.; Love, C.; Ludhova, L.; Luitz, S.; Ma, Y. Q.; Machulin, I.; Mandarano, A.; Mari, S.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meroni, E.; Meyers, P. D.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M. E.; Mosteiro, P.; Mount, B.; Muratova, V.; Musico, P.; Nelson, A.; Odrowski, S.; Okounkova, M.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Papp, L.; Parmeggiano, S.; Parsells, R.; Pelczar, K.; Pelliccia, N.; Perasso, S.; Pocar, A.; Pordes, S.; Pugachev, D.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Reinhold, B.; Renshaw, A.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, S. D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Segreto, E.; Semenov, D.; Shields, E.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Unzhakov, E.; Vogelaar, R. B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A.; Westerdale, S.; Wojcik, M.; Wright, A.; Xiang, X.; Xu, J.; Yang, C. G.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhu, C.; Zuzel, G.
Comments: 26 pages, 7 figures; updated figures and references, notably Fig. 7 has updated CDMSII curve; fixed typos; clarified some language and figures; updated references
Submitted: 2014-10-02, last modified: 2015-02-27
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We report here the null results of a dark matter search for a (1422+-67) kg d exposure with an atmospheric argon fill. This is the most sensitive dark matter search performed with an argon target, corresponding to a 90% CL upper limit on the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP mass of 100 GeV/c^2.
[13]  oai:arXiv.org:1406.2374  [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
Comments:
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of $\sim$10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons ($>99.5%$) and showers of secondary particles from muon interactions in the rock ($>70%$). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
[14]  oai:arXiv.org:1412.2969  [pdf] - 925627
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
The DarkSide Collaboration; Agnes, P.; Alexander, T.; Alton, A.; Arisaka, K.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Brigatti, A.; Brodsky, J.; Budano, F.; Cadonati, L.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Cavalcante, P.; Chavarria, A.; Chepurnov, A.; Cocco, A. G.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Deo, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pieto, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Goretti, A.; Grandi, L.; Gromov, M.; Guan, M. Y.; Guardincerri, Y.; Hackett, B.; Herner, K.; Hungerford, E.; Ianni, Al.; Ianni, An.; Jollet, C.; Keeter, K.; Kendziora, C.; Kidner, S.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kurlej, A.; Li, P. X.; Loer, B.; Lombardi, P.; Love, C.; Ludhova, L.; Luitz, S.; Ma, Y. Q.; Machulin, I.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, J.; Meregaglia, A.; Meroni, E.; Meyers, P. D.; Milincic, R.; Montanari, D.; Montuschi, M.; Monzani, M. E.; Mosteiro, P.; Mount, B.; Muratova, V.; Musico, P.; Nelson, A.; Odrowski, S.; Okounkoa, M.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Papp, L.; Parmeggiano, S.; Parsells, Bob; Pelczar, K.; Pelliccia, N.; Perasso, S.; Pocar, A.; Pordes, S.; Pugachev, D.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Reinhold, B.; Renshaw, A.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, S. D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Segreto, E.; Semenov, D.; Shields, E.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Unzhakov, E.; Vogelaar, R. B.; Wada, M.; Walker, S. E.; Wang, H.; Wang, Y.; Watson, A.; Westerdale, S.; Wojcik, M.; Wright, A.; Xiang, X.; Xu, J.; Yang, C. G.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhu, C.; Zuzel, G.
Comments:
Submitted: 2014-12-09, last modified: 2015-01-22
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions.
[15]  oai:arXiv.org:1311.1088  [pdf] - 783783
Observation and applications of single-electron charge signals in the XENON100 experiment
Comments: 16 pages, 8 figures. Accepted for publication in Journal of Physics G: Nuclear and Particle Physics
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
[16]  oai:arXiv.org:1310.8327  [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Comments: Snowmass CF1 Final Summary Report: 47 pages and 28 figures with a 5 page appendix on instrumentation R&D
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
[17]  oai:arXiv.org:1207.3458  [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
Comments: 18 pages, 17 figures, information for the 224.6 live days run included
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.
[18]  oai:arXiv.org:1306.2303  [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Comments:
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($\alpha$,n) and spontaneous fission reactions due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively, and conclude that they do not limit the sensitivity of the experiment.
[19]  oai:arXiv.org:1204.6218  [pdf] - 1118329
Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches
Alexander, T.; Alton, D.; Arisaka, K.; Back, H. O.; Beltrame, P.; Benziger, J.; Bonfini, G.; Brigatti, A.; Brodsky, J.; Cadonati, L.; Calaprice, F.; Candela, A.; Cao, H.; Cavalcante, P.; Chavarria, A.; Chepurnov, A.; Cline, D.; Cocco, A. G.; Condon, C.; D'Angelo, D.; Davini, S.; De Haas, E.; Derbin, A.; Di Pietro, G.; Dratchnev, I.; Durben, D.; Empl, A.; Etenko, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Gabriele, F.; Galbiati, C.; Gazzana, S.; Ghag, C.; Ghiano, C.; Goretti, A.; Grandi, L.; Gromov, M.; Guan, M.; Guo, C.; Guray, G.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; Kayunov, A.; Keeter, K.; Kendziora, C.; Kidner, S.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Shields, E.; Li, P.; Loer, B.; Lombardi, P.; Love, C.; Ludhova, L.; Lukyanchenko, L.; Lund, A.; Lung, K.; Ma, Y.; Machulin, I.; Maricic, J.; Martoff, C. J.; Meng, Y.; Meroni, E.; Meyers, P. D.; Mohayai, T.; Montanari, D.; Montuschi, M.; Mosteiro, P.; Mount, B.; Muratova, V.; Nelson, A.; Nemtzow, A.; Nurakhov, N.; Orsini, M.; Ortica, F.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Parsells, R.; Pelliccia, N.; Perasso, L.; Perfetto, F.; Pinsky, L.; Pocar, A.; Pordes, S.; Ranucci, G.; Razeto, A.; Romani, A.; Rossi, N.; Saggese, P.; Saldanha, R.; Salvo, C.; Sands, W.; Seigar, M.; Semenov, D.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Teymourian, A.; Thompson, J.; Unzhakov, E.; Vogelaar, R. B.; Wang, H.; Westerdale, S.; Wojcik, M.; Wright, A.; Xu, J.; Yang, C.; Zavatarelli, S.; Zehfus, M.; Zhong, W.; Zuzel, G.
Comments: 10 pages, 7 figures, Accepted for publication in Astroparticle Physics
Submitted: 2012-04-27, last modified: 2013-08-14
As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.
[20]  oai:arXiv.org:1304.1427  [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
Comments: 10 pages, 10 figures. Matches version accepted by PRD. Contains revised representation of expected WIMP event signature. Conclusions remain unaffected
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.
[21]  oai:arXiv.org:1207.5988  [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
Comments: 6 pages, 5 figures. Matches version accepted by PRL. Includes limits up to 10 TeV/c^2, published as supplementary material: http://prl.aps.org/supplemental/PRL/v109/i18/e181301 Please cite high mass limits as "Phys. Rev. Lett. 109, 181301 (2012), online supplementary material."
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on the spin-independent elastic WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2 and 90% confidence level.
[22]  oai:arXiv.org:1101.3866  [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
Comments: 10 pages, 12 figures The updated version of the paper takes into account the new measurement of $^{136}$Xe 2$\nu$ $\beta\beta$ decay by EXO-200, with a half-life of (2.11$\pm0.04\pm$0.021)$\times10^{21}$ years
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a detailed geometry together with the measured radioactivity of all detector components, we predict an electronic recoil background in the WIMP-search energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2 events/(kg-day-keV), consistent with the experiment's design goal. The predicted background spectrum is in very good agreement with the data taken during the commissioning of the detector, in Fall 2009.
[23]  oai:arXiv.org:1301.6620  [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
Comments: 5 pages, 3 figures; corrected caption of figure 3
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x 10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[24]  oai:arXiv.org:1211.0836  [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Comments: 12 pages, 4 figures
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
[25]  oai:arXiv.org:1208.5762  [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
Comments: 3 pages, no figures
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.
[26]  oai:arXiv.org:1107.1295  [pdf] - 966956
Studies of a three-stage dark matter and neutrino observatory based on multi-ton combinations of liquid xenon and liquid argon detectors
Comments:
Submitted: 2011-07-07, last modified: 2012-04-15
We study a three stage dark matter and neutrino observatory based on multi-ton two-phase liquid Xe and Ar detectors with sufficiently low backgrounds to be sensitive to WIMP dark matter interaction cross sections down to 10E-47 cm^2, and to provide both identification and two independent measurements of the WIMP mass through the use of the two target elements in a 5:1 mass ratio, giving an expected similarity of event numbers. The same detection systems will also allow measurement of the pp solar neutrino spectrum, the neutrino flux and temperature from a Galactic supernova, and neutrinoless double beta decay of 136Xe to the lifetime level of 10E27 - 10E28 y corresponding to the Majorana mass predicted from current neutrino oscillation data. The proposed scheme would be operated in three stages G2, G3, G4, beginning with fiducial masses 1-ton Xe + 5-ton Ar (G2), progressing to 10-ton Xe + 50-ton Ar (G3) then, dependent on results and performance of the latter, expandable to 100-ton Xe + 500-ton Ar (G4). This method of scale-up offers the advantage of utilizing the Ar vessel and ancillary systems of one stage for the Xe detector of the succeeding stage, requiring only one new detector vessel at each stage. Simulations show the feasibility of reducing or rejecting all external and internal background levels to a level <1 events per year for each succeeding mass level, by utilizing an increasing outer thickness of target material as self-shielding. The system would, with increasing mass scale, become increasingly sensitive to annual signal modulation, the agreement of Xe and Ar results confirming the Galactic origin of the signal. Dark matter sensitivities for spin-dependent and inelastic interactions are also included, and we conclude with a discussion of possible further gains from the use of Xe/Ar mixtures.
[27]  oai:arXiv.org:1107.2155  [pdf] - 474250
The XENON100 Dark Matter Experiment
Comments: 23 pages, 27 figures; version accepted by journal
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs. The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of \sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[28]  oai:arXiv.org:1104.3121  [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
Comments: 3 pages, 3 figures
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.
[29]  oai:arXiv.org:1103.0303  [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
Comments: 8 pages, 6 figures, matches accepted version
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to make a discovery claim, and the results are derived with a proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows to extract additional information from the data, and place stronger limits on the spin-independent elastic WIMP-nucleon scattering cross-section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[30]  oai:arXiv.org:1104.2549  [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
Comments: 5 pages, 5 figures; matches accepted version
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.
[31]  oai:arXiv.org:1103.3689  [pdf] - 966518
Characterization of the QUartz Photon Intensifying Detector (QUPID) for Noble Liquid Detectors
Comments: 15 pages, 22 figures
Submitted: 2011-03-18, last modified: 2011-07-15
Dark Matter and Double Beta Decay experiments require extremely low radioactivity within the detector materials. For this purpose, the University of California, Los Angeles and Hamamatsu Photonics have developed the QUartz Photon Intensifying Detector (QUPID), an ultra-low background photodetector based on the Hybrid Avalanche Photo Diode (HAPD) and entirely made of ultraclean synthetic fused silica. In this work we present the basic concept of the QUPID and the testing measurements on QUPIDs from the first production line. Screening of radioactivity at the Gator facility in the Laboratori Nazionali del Gran Sasso has shown that the QUPIDs safely fulfill the low radioactive contamination requirements for the next generation zero background experiments set by Monte Carlo simulations. The quantum efficiency of the QUPID at room temperature is > 30% at the xenon scintillation wavelength. At low temperatures, the QUPID shows a leakage current less than 1 nA and a global gain of 10^5. In these conditions, the photocathode and the anode show > 95% linearity up to 1 uA for the cathode and 3 mA for the anode. The photocathode and collection efficiency are uniform to 80% over the entire surface. In parallel with single photon counting capabilities, the QUPIDs have a good timing response: 1.8 +/- 0.1 ns rise time, 2.5 +/- 0.2 ns fall time, 4.20 +/- 0.05 ns pulse width, and 160 +/- 30 ps transit time spread. The QUPIDs have also been tested in a liquid xenon environment, and scintillation light from 57Co and 210Po radioactive sources were observed.
[32]  oai:arXiv.org:1005.0380  [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
Comments: 5 pages, 5 figures. Matches published version
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the pre-defined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs at 90% confidence level. Below 20 GeV/c^2, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.
[33]  oai:arXiv.org:0912.3689  [pdf] - 125372
Status of the CRESST Dark Matter Search
Comments: Proceedings of the 13th International Workshop on Low Temperature Detectors, 4 pages, 3 figures
Submitted: 2009-12-18
The CRESST experiment aims for a detection of dark matter in the form of WIMPs. These particles are expected to scatter elastically off the nuclei of a target material, thereby depositing energy on the recoiling nucleus. CRESST uses scintillating CaWO4 crystals as such a target. The energy deposited by an interacting particle is primarily converted to phonons which are detected by transition edge sensors. In addition, a small fraction of the interaction energy is emitted from the crystals in the form of scintillation light which is measured in coincidence with the phonon signal by a separate cryogenic light detector for each target crystal. The ratio of light to phonon energy permits the discrimination between the nuclear recoils expected from WIMPs and events from radioactive backgrounds which primarily lead to electron recoils. CRESST has shown the success of this method in a commissioning run in 2007 and, since then, further investigated possibilities for an even better suppression of backgrounds. Here, we report on a new class of background events observed in the course of this work. The consequences of this observation are discussed and we present the current status of the experiment.
[34]  oai:arXiv.org:0912.0170  [pdf] - 971925
Composite CaWO4 Detectors for the CRESST-II Experiment
Comments: Proceedings of the Thirteenth International Workshop on Low Temperature Detectors 4 pages, 9 figures
Submitted: 2009-12-01
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber crystal. The process of evaporation causes a decrease in the scintillation light output. This, together with the need of a big-scale detector production for the upcoming EURECA experiment lead to investigations for producing thermometers on smaller crystals which are glued onto the absorber crystal. In our Run 31 we tested composite detectors for the first time in the Gran Sasso setup. They seem to produce higher light yields as hoped and could provide an additional time based discrimination mechanism for low light yield clamp events.
[35]  oai:arXiv.org:0905.4282  [pdf] - 24648
Electron and Gamma Background in CRESST Detectors
Comments: 7 pages, 12 figures
Submitted: 2009-05-26
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by three detectors over many weeks of data taking. Understanding these spectra is mandatory if one wants to further reduce the background level, and allows us to cross-check the calibration of the detectors. We identify a variety of sources, such as intrinsic contaminations due to primordial radioisotopes and cosmogenic activation of the target material. In particular, we detect a 3.6keV X-ray line from the decay of 41-Ca with an activity of (26\pm4)\mu Bq, corresponding to a ratio 41-Ca/40-Ca=(2.2\pm0.3)\times10^{-16}.
[36]  oai:arXiv.org:0903.4687  [pdf] - 22801
Discrimination of Recoil Backgrounds in Scintillating Calorimeters
Comments: 5 pages, 9 figures
Submitted: 2009-03-26
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a way to discriminate this source of nuclear recoil background by means of a scintillating foil, and demonstrate its effectiveness. This leads to an observable difference in the pulse shape of the light detector, which can be used to tag these events. Differences in pulse shape of the phonon detector between lead and electron recoils are also extracted, opening the window to future additional background suppression techniques based on pulse shape discrimination in such experiments.
[37]  oai:arXiv.org:0809.1829  [pdf] - 16181
Commissioning Run of the CRESST-II Dark Matter Search
Comments: 10 pages, 9 figs No essential changes in content. Minor errors corrected. Sentence added at end of introduction concerning increased sensitivity. Best limit on plots at M=50 GeV. Text labelling of candidate events corrected
Submitted: 2008-09-10, last modified: 2009-02-16
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007. The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect the scintillation light from the CaWO_4.Information from light-quenching factor studies allows the definition of a region of the energy-light yield plane which corresponds to tungsten recoils. A neutron test is reported which supports the principle of using the light yield to identify the recoiling nucleus. Data obtained with two detector modules for a total exposure of 48 kg-days are presented. Judging by the rate of events in the "all nuclear recoils" acceptance region the apparatus shows a factor ~ten improvement with respect to previous results, which we attribute principally to the presence of the neutron shield. In the "tungsten recoils" acceptance region three events are found, corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark matter flux, coherent or spin independent interactions,then yield a limit for WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
[38]  oai:arXiv.org:astro-ph/0604094  [pdf] - 81163
New Technique for the Measurement of the Scintillation Efficiency of Nuclear Recoils
Comments: Preprint accepted for publication in NIM A
Submitted: 2006-04-05
We present a new technique developed for the measurement of the scintillation efficiency of nuclear recoils in solid scintillators. Using this technique we measured the quenching of the scintillation efficiency for the various recoiling nuclei in CaWO4 crystals which are used in direct Dark Matter searches.