Normalized to: Pandola, L.
[1]
oai:arXiv.org:2004.02024 [pdf] - 2075899
SiPM-matrix readout of two-phase argon detectors using
electroluminescence in the visible and near infrared range
The DarkSide collaboration;
Aalseth, C. E.;
Abdelhakim, S.;
Agnes, P.;
Ajaj, R.;
Albuquerque, I. F. M.;
Alexander, T.;
Alici, A.;
Alton, A. K.;
Amaudruz, P.;
Ameli, F.;
Anstey, J.;
Antonioli, P.;
Arba, M.;
Arcelli, S.;
Ardito, R.;
Arnquist, I. J.;
Arpaia, P.;
Asner, D. M.;
Asunskis, A.;
Ave, M.;
Back, H. O.;
Barbaryan, V.;
Olmedo, A. Barrado;
Batignani, G.;
Bisogni, M. G.;
Bocci, V.;
Bondar, A.;
Bonfini, G.;
Bonivento, W.;
Borisova, E.;
Bottino, B.;
Boulay, M. G.;
Bunker, R.;
Bussino, S.;
Buzulutskov, A.;
Cadeddu, M.;
Cadoni, M.;
Caminata, A.;
Canci, N.;
Candela, A.;
Cantini, C.;
Caravati, M.;
Cariello, M.;
Carnesecchi, F.;
Castellani, A.;
Castello, P.;
Cavalcante, P.;
Cavazza, D.;
Cavuoti, S.;
Cebrian, S.;
Ruiz, J. M. Cela;
Celano, B.;
Cereseto, R.;
Chashin, S.;
Cheng, W.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Citterio, M.;
Coccetti, F.;
Cocco, V.;
Colocci, M.;
Vidal, E. Conde;
Consiglio, L.;
Cossio, F.;
Covone, G.;
Crivelli, P.;
D'Antone, I.;
D'Incecco, M.;
Rolo, M. D. Da Rocha;
Dadoun, O.;
Daniel, M.;
Davini, S.;
De Cecco, S.;
De Deo, M.;
De Falco, A.;
De Gruttola, D.;
De Guido, G.;
De Rosa, G.;
Dellacasa, G.;
Demontis, P.;
De Pasquale, S.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Noto, L.;
Di Pietro, G.;
Di Stefano, P.;
Dionisi, C.;
Dolganov, G.;
Dordei, F.;
Downing, M.;
Edalatfar, F.;
Empl, A.;
Diaz, M. Fernandez;
Filip, C.;
Fiorillo, G.;
Fomenko, K.;
Franceschi, A.;
Franco, D.;
Frolov, E.;
Froudakis, G. E.;
Funicello, N.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Garbini, M.;
Abia, P. Garcia;
Fora, D. Gascón;
Gendotti, A.;
Ghiano, C.;
Ghisi, A.;
Giampa, P.;
Giampaolo, R. A.;
Giganti, C.;
Giorgi, M. A.;
Giovanetti, G. K.;
Gligan, M. L.;
Gorchakov, O.;
Grab, M.;
Diaz, R. Graciani;
Grassi, M.;
Grate, J. W.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guerra, M. B. B.;
Guerzoni, M.;
Gulino, M.;
Haaland, R. K.;
Hackett, B. R.;
Hallin, A.;
Haranczyk, M.;
Harrop, B.;
Hoppe, E. W.;
Horikawa, S.;
Hosseini, B.;
Hubaut, F.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ilyasov, A.;
Ippolito, V.;
Jillings, C.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Kondo, K.;
Kopp, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kugathasan, R.;
Kuss, M.;
La Commara, M.;
La Delfa, L.;
Lai, M.;
Lebois, M.;
Lehnert, B.;
Levashko, N.;
Li, X.;
Liqiang, Q.;
Lissia, M.;
Lodi, G. U.;
Longo, G.;
Lussana, R.;
Luzzi, L.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Manecki, S.;
Mapelli, L.;
Margotti, A.;
Mari, S. M.;
Mariani, M.;
Maricic, J.;
Marinelli, M.;
Marras, D.;
Martínez, M.;
Rojas, A. D. Martinez;
Mascia, M.;
Mason, J.;
Masoni, A.;
McDonald, A. B.;
Messina, A.;
Miletic, T.;
Milincic, R.;
Moggi, A.;
Moioli, S.;
Monroe, J.;
Morrocchi, M.;
Mroz, T.;
Mu, W.;
Muratova, V. N.;
Murphy, S.;
Muscas, C.;
Musico, P.;
Nania, R.;
Napolitano, T.;
Agasson, A. Navrer;
Nessi, M.;
Nikulin, I.;
Nosov, V.;
Nowak, J. A.;
Oleinik, A.;
Oleynikov, V.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Palmas, S.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pazzona, F.;
Peeters, S.;
Pegoraro, P. A.;
Pelczar, K.;
Pellegrini, L. A.;
Pellegrino, C.;
Pelliccia, N.;
Perotti, F.;
Pesudo, V.;
Picciau, E.;
Pietropaolo, F.;
Pocar, A.;
Pollmann, T. R.;
Portaluppi, D.;
Poudel, S. S.;
Pralavorio, P.;
Price, D.;
Radics, B.;
Raffaelli, F.;
Ragusa, F.;
Razeti, M.;
Regenfus, C.;
Renshaw, A. L.;
Rescia, S.;
Rescigno, M.;
Retiere, F.;
Rignanese, L. P.;
Ripoli, C.;
Rivetti, A.;
Rode, J.;
Romani, A.;
Romero, L.;
Rossi, N.;
Rubbia, A.;
Sala, P.;
Salatino, P.;
Samoylov, O.;
García, E. Sánchez;
Sandford, E.;
Sanfilippo, S.;
Sant, M.;
Santone, D.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Scioli, G.;
Segreto, E.;
Seifert, A.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Siddhanta, S.;
Simeone, M.;
Singh, P. N.;
Skensved, P.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sobrero, G.;
Sokolov, A.;
Sotnikov, A.;
Stainforth, R.;
Steri, A.;
Stracka, S.;
Strickland, V.;
Suffritti, G. B.;
Sulis, S.;
Suvorov, Y.;
Szelc, A. M.;
Tartaglia, R.;
Testera, G.;
Thorpe, T.;
Tonazzo, A.;
Tosi, A.;
Tuveri, M.;
Unzhakov, E. V.;
Usai, G.;
Vacca, A.;
Vázquez-Jáuregui, E.;
Viant, T.;
Viel, S.;
Villa, F.;
Vishneva, A.;
Vogelaar, R. B.;
Wahl, J.;
Walding, J. J.;
Wang, H.;
Wang, Y.;
Westerdale, S.;
Wheadon, R. J.;
Williams, R.;
Wilson, J.;
Wojcik, Marcin;
Wojcik, Mariusz;
Wu, S.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zuffa, M.;
Zuzel, G.
Submitted: 2020-04-04
Proportional electroluminescence (EL) in noble gases is used in two-phase
detectors for dark matter search to record (in the gas phase) the ionization
signal induced by particle scattering in the liquid phase. The "standard" EL
mechanism is considered to be due to noble gas excimer emission in the vacuum
ultraviolet (VUV). In addition to it, there are two alternative mechanisms,
producing light in the visible and near infrared (NIR) range. The first is due
to bremsstrahlung of electrons scattered on neutral atoms (so-called neutral
bremsstrahlung, NBrS). The second, responsible for electron avalanche
scintillations in the NIR at higher electric fields, is due to transitions
between excited atomic states. In this work, we have for the first time
demonstrated two alternative techniques of the optical readout of two-phase
argon detectors, in the visible and NIR range, using a SiPM matrix and
electroluminescence due to either neutral bremsstrahlung or avalanche
scintillations effects. The amplitude yield and position resolution were
measured for these readout techniques, which allowed to assess the detection
threshold for electron and nuclear recoils in two-phase argon detectors for
dark matter search. It should be emphasized that this is the first practical
application of the NBrS effect in detection science.
[2]
oai:arXiv.org:2001.08106 [pdf] - 2080977
Design and construction of a new detector to measure ultra-low
radioactive-isotope contamination of argon
The DarkSide Collaboration;
Aalseth, C. E.;
Abdelhakim, S.;
Acerbi, F.;
Agnes, P.;
Ajaj, R.;
Albuquerque, I. F. M.;
Alexander, T.;
Alici, A.;
Alton, A. K.;
Amaudruz, P.;
Ameli, F.;
Anstey, J.;
Antonioli, P.;
Arba, M.;
Arcelli, S.;
Ardito, R.;
Arnquist, I. J.;
Arpaia, P.;
Asner, D. M.;
Asunskis, A.;
Ave, M.;
Back, H. O.;
Olmedo, A. Barrado;
Batignani, G.;
Bisogni, M. G.;
Bocci, V.;
Bondar, A.;
Bonfini, G.;
Bonivento, W.;
Borisova, E.;
Bottino, B.;
Boulay, M. G.;
Bunker, R.;
Bussino, S.;
Buzulutskov, A.;
Cadeddu, M.;
Cadoni, M.;
Caminata, A.;
Canci, N.;
Candela, A.;
Cantini, C.;
Caravati, M.;
Cariello, M.;
Carnesecchi, F.;
Carpinelli, M.;
Castellani, A.;
Castello, P.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavazza, D.;
Cavuoti, S.;
Cebrian, S.;
Ruiz, J. M. Cela;
Celano, B.;
Cereseto, R.;
Cheng, W.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Citterio, M.;
Cocco, A. G.;
Cocco, V.;
Colocci, M.;
Consiglio, L.;
Cossio, F.;
Covone, G.;
Crivelli, P.;
D'Antone, I.;
D'Incecco, M.;
D'Urso, D.;
Rolo, M. D. Da Rocha;
Dadoun, O.;
Daniel, M.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Falco, A.;
De Filippis, G.;
De Gruttola, D.;
De Guido, G.;
De Rosa, G.;
Dellacasa, G.;
Demontis, P.;
DePaquale, S.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Noto, L.;
Di Pietro, G.;
Di Stefano, P.;
Dionisi, C.;
Dolganov, G.;
Dordei, F.;
Downing, M.;
Edalatfar, F.;
Empl, A.;
Diaz, M. Fernandez;
Ferri, A.;
Filip, C.;
Fiorillo, G.;
Fomenko, K.;
Franceschi, A.;
Franco, D.;
Froudakis, G. E.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Abia, P. Garcia;
Fora, D. Gascón;
Gendotti, A.;
Ghiano, C.;
Ghisi, A.;
Giagu, S.;
Giampa, P.;
Giampaolo, R. A.;
Giganti, C.;
Giorgi, M. A.;
Giovanetti, G. K.;
Gligan, M. L.;
Gola, A.;
Gorchakov, O.;
Grab, M.;
Diaz, R. Graciani;
Granato, F.;
Grassi, M.;
Grate, J. W.;
Grigoriev, G. Y.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guerra, M. B. B.;
Guerzoni, M.;
Gulino, M.;
Haaland, R. K.;
Hackett, B. R.;
Hallin, A.;
Harrop, B.;
Hoppe, E. W.;
Horikawa, S.;
Hosseini, B.;
Hubaut, F.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ilyasov, A.;
Ippolito, V.;
Jillings, C.;
Keeter, K.;
Kendziora, C. L.;
Kim, S.;
Kochanek, I.;
Kondo, K.;
Kopp, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kugathasan, R.;
Kuss, M.;
Kuźniak, M.;
La Commara, M.;
La Delfa, L.;
Lai, M.;
Langrock, S.;
Lebois, M.;
Lehnert, B.;
Levashko, N.;
Li, X.;
Liqiang, Q.;
Lissia, M.;
Lodi, G. U.;
Longo, G.;
Manzano, R. López;
Lussana, R.;
Luzzi, L.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Marcante, M.;
Margotti, A.;
Mari, S. M.;
Mariani, M.;
Maricic, J.;
Marinelli, M.;
Marras, D.;
Martínez, M.;
Morales, J. J. Martínez;
Rojas, A. D. Martinez;
Martoff, C. J.;
Mascia, M.;
Mason, J.;
Masoni, A.;
Mazzi, A.;
McDonald, A. B.;
Messina, A.;
Meyers, P. D.;
Miletic, T.;
Milincic, R.;
Moggi, A.;
Moioli, S.;
Monroe, J.;
Morrocchi, M.;
Mroz, T.;
Mu, W.;
Muratova, V. N.;
Murphy, S.;
Muscas, C.;
Musico, P.;
Nania, R.;
Napolitano, T.;
Agasson, A. Navrer;
Nessi, M.;
Nikulin, I.;
Oleinik, A.;
Oleynikov, V.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Palmas, S.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Paternoster, G.;
Pavletcov, V.;
Pazzona, F.;
Peeters, S.;
Pegoraro, P. A.;
Pelczar, K.;
Pellegrini, L. A.;
Pellegrino, C.;
Pelliccia, N.;
Perotti, F.;
Pesudo, V.;
Picciau, E.;
Piemonte, C.;
Pietropaolo, F.;
Pocar, A.;
Pollman, T.;
Portaluppi, D.;
Poudel, S. S.;
Pralavorio, P.;
Price, D.;
Radics, B.;
Raffaelli, F.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Regazzoni, V.;
Regenfus, C.;
Renshaw, A. L.;
Rescia, S.;
Rescigno, M.;
Retiere, F.;
Rignanese, L. P.;
Rivetti, A.;
Romani, A.;
Romero, L.;
Rossi, N.;
Rubbia, A.;
Sablone, D.;
Sala, P.;
Salatino, P.;
Samoylov, O.;
García, E. Sánchez;
Sanfilippo, S.;
Sant, M.;
Santone, D.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Scioli, G.;
Segreto, E.;
Seifert, A.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Siddhanta, S.;
Simeone, M.;
Singh, P. N.;
Skensved, P.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sobrero, G.;
Sokolov, A.;
Sotnikov, A.;
Stainforth, R.;
Steri, A.;
Stracka, S.;
Strickland, V.;
Suffritti, G. B.;
Sulis, S.;
Suvorov, Y.;
Szelc, A. M.;
Tartaglia, R.;
Testera, G.;
Thorpe, T.;
Tonazzo, A.;
Tosi, A.;
Tuveri, M.;
Unzhakov, E. V.;
Usai, G.;
Vacca, A.;
Vázquez-Jáuregui, E.;
Verducci, M.;
Viant, T.;
Viel, S.;
Villa, F.;
Vishneva, A.;
Vogelaar, R. B.;
Wada, M.;
Wahl, J.;
Walding, J. J.;
Wang, H.;
Wang, Y.;
Westerdale, S.;
Wheadon, R. J.;
Williams, R.;
Wilson, J.;
Wojcik, Marcin;
Wojcik, Mariusz;
Wu, S.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zuffa, M.;
Zuzel, G.
Submitted: 2020-01-22
Large liquid argon detectors offer one of the best avenues for the detection
of galactic weakly interacting massive particles (WIMPs) via their scattering
on atomic nuclei. The liquid argon target allows exquisite discrimination
between nuclear and electron recoil signals via pulse-shape discrimination of
the scintillation signals. Atmospheric argon (AAr), however, has a naturally
occurring radioactive isotope, $^{39}$Ar, a $\beta$ emitter of cosmogenic
origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up
concerns. The use of argon extracted from underground wells, deprived of
$^{39}$Ar, is key to the physics potential of these experiments. The
DarkSide-20k dark matter search experiment will operate a dual-phase time
projection chamber with 50 tonnes of radio-pure underground argon (UAr), that
was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger
than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is
crucial for the success of DarkSide-20k, as well as for future experiments of
the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by
the DArT in ArDM experiment, a small chamber made with extremely radio-pure
materials that will be placed at the centre of the ArDM detector, in the
Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an
active veto for background radioactivity, mostly $\gamma$-rays from the ArDM
detector materials and the surrounding rock. This article describes the DArT in
ArDM project, including the chamber design and construction, and reviews the
background required to achieve the expected performance of the detector.
[3]
oai:arXiv.org:1907.09332 [pdf] - 1998536
Measurement of the ion fraction and mobility of $^{218}$Po produced in
$^{222}$Rn decays in liquid argon
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Ave, M.;
Back, H. O.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W. M.;
Bottino, B.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Chepurnov, A.;
Cicalo, C.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
D'Incecco, M.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
D'Urso, D.;
Edkins, E.;
Empl, A.;
Fiorillo, G.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Ippolito, V.;
Johnson, T. N.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lissia, M.;
Longo, G.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Monte, A.;
Morrocchi, M.;
Muratova, V. N.;
Musico, P.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pelczar, K.;
Pelliccia, N.;
Picciau, E.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Savarese, C.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, R. B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zuzel, G.
Submitted: 2019-07-22, last modified: 2019-10-28
We report measurements of the charged daughter fraction of $^{218}$Po as a
result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions,
using radon-polonium coincidences from the $^{238}$U chain identified in 532
live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is
charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is
(8.6$\pm$0.1)$\times$10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
[4]
oai:arXiv.org:1704.03741 [pdf] - 1813965
Directional dark matter detection sensitivity of a two-phase liquid
argon detector
Cadeddu, M.;
Lissia, M.;
Agnes, P.;
Batignani, G.;
Bonivento, W. M.;
Bottino, B.;
Caravati, M.;
Cocco, A.;
Covone, G.;
de Candia, A.;
Catalanotti, S.;
Cataudella, V.;
Cicalo', C.;
De Filippis, G.;
De Rosa, G.;
Davini, S.;
Devoto, A.;
Dionisi, C.;
Franco, D.;
Giganti, C.;
Galbiati, C.;
Giagu, S.;
Gulino, M.;
Kuss, M.;
Lista, L.;
Longo, G.;
Navrer-Agasson, A.;
Pallavicini, M.;
Pandola, L.;
Paoloni, E.;
Picciau, E.;
Razeti, M.;
Rescigno, M.;
Riffard, Q.;
Rossi, B.;
Rossi, N.;
Testera, G.;
Trinchese, P.;
Tonazzo, A.;
Walker, S.;
Fiorillo, G.
Submitted: 2017-04-11, last modified: 2019-01-14
We examine the sensitivity of a large scale two-phase liquid argon detector
to the directionality of the dark matter signal. This study was performed under
the assumption that, above 50 keV of recoil energy, one can determine (with
some resolution) the direction of the recoil nucleus without head-tail
discrimination, as suggested by past studies that proposed to exploit the
dependence of columnar recombination on the angle between the recoil nucleus
direction and the electric field. In this paper we study the differential
interaction recoil rate as a function of the recoil direction angle with
respect to the zenith for a detector located at the Laboratori Nazionali del
Gran Sasso and we determine its diurnal and seasonal modulation. Using a
likelihood-ratio based approach we show that, with the angular information
alone, 100 events are enough to reject the isotropic hypothesis at three
standard deviation level. For an exposure of 100 tonne years this would
correspond to a spin independent WIMP-nucleon cross section of about 10^-46
cm^2 at 200 GeV WIMP mass. The results presented in this paper provide strong
motivation for the experimental determination of directional recoil effects in
two-phase liquid argon detectors.
[5]
oai:arXiv.org:1802.07198 [pdf] - 1789406
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
The DarkSide Collaboration;
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Araujo, G. R.;
Ave, M.;
Back, H. O.;
Baldin, B.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W.;
Bottino, B.;
Budano, F.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Chepurnov, A.;
Cicalò, C.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
D'Incecco, M.;
D'Urso, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
De Vincenzi, M.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fitzpatrick, R. S.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ippolito, V.;
James, I.;
Johnson, T. N.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lissia, M.;
Longo, G.;
Ma, Y.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Monte, A.;
Morrocchi, M.;
Mount, B. J.;
Muratova, V. N.;
Musico, P.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pelczar, K.;
Pelliccia, N.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Pugachev, D. A.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Reinhold, B.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Savarese, C.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zuzel, G.
Submitted: 2018-02-20, last modified: 2018-11-19
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon
time projection chamber operating at Laboratori Nazionali del Gran Sasso. This
paper reports on the blind analysis of a (16,660+-270) kg d exposure using a
target of low-radioactivity argon extracted from underground sources. We find
no events in the dark matter selection box and set a 90% C.L. upper limit on
the dark matter-nucleon spin-independent cross section of 1.14E-44 cm^2
(3.78E-44 cm^2, 3.43E-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10
TeV/c^2).
[7]
oai:arXiv.org:1802.06994 [pdf] - 1739878
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
The DarkSide Collaboration;
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Araujo, G. R.;
Asner, D. M.;
Ave, M.;
Back, H. O.;
Baldin, B.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W.;
Bottino, B.;
Budano, F.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Cereseto, R.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
D'Incecco, M.;
D'Urso, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
De Vincenzi, M.;
Demontis, P.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Abia, P. Garcia;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Hassanshahi, M. H.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Ippolito, V.;
James, I.;
Johnson, T. N.;
Kahn, Y.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lisanti, M.;
Lissia, M.;
Loer, B.;
Longo, G.;
Ma, Y.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Mishra-Sharma, S.;
Monte, A.;
Morrocchi, M.;
Mount, B. J.;
Muratova, V. N.;
Musico, P.;
Nania, R.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pazzona, F.;
Pelczar, K.;
Pelliccia, N.;
Pesudo, V.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Pugachev, D. A.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Reinhold, B.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Sant, M.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suffritti, G. B.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Wojcik, M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zichichi, A.;
Zuzel, G.
Submitted: 2018-02-20, last modified: 2018-08-28
We present the results of a search for dark matter WIMPs in the mass range
below 20 GeV/c^2 using a target of low-radioactivity argon. The data were
obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso
(LNGS). The analysis is based on the ionization signal, for which the
DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The
observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and
is almost entirely accounted for by known background sources. We obtain a 90%
C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section
of dark matter WIMPs on nucleons, extending the exclusion region for dark
matter below previous limits in the range 1.8-6 GeV/c^2.
[8]
oai:arXiv.org:1108.5584 [pdf] - 1083670
Demonstration and Comparison of Operation of Photomultiplier Tubes at
Liquid Argon Temperature
Acciarri, R.;
Antonello, M.;
Boffelli, F.;
Cambiaghi, M.;
Canci, N.;
Cavanna, F.;
Cocco, A. G.;
Deniskina, N.;
Di Pompeo, F.;
Fiorillo, G.;
Galbiati, C.;
Grandi, L.;
Kryczynski, P.;
Meng, G.;
Montanari, C.;
Palamara, O.;
Pandola, L.;
Perfetto, F.;
Mortari, G. B. Piano;
Pietropaolo, F.;
Raselli, G. L.;
Rossella, M.;
Rubbia, C.;
Segreto, E.;
Szelc, A. M.;
Triossi, A.;
Ventura, S.;
Vignoli, C.;
Zani, A.
Submitted: 2011-08-29, last modified: 2011-09-26
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments.
[9]
oai:arXiv.org:1102.0208 [pdf] - 1051810
Overview of the European Underground Facilities
Submitted: 2011-02-01
Deep underground laboratories are the only places where the extremely low
background radiation level required for most experiments looking for rare
events in physics and astroparticle physics can be achieved. Underground sites
are also the most suitable location for very low background gamma-ray
spectrometers, able to assay trace radioactive contaminants. Many operational
infrastructures are already available worldwide for science, differing for
depth, dimension and rock characteristics. Other underground sites are emerging
as potential new laboratories. In this paper the European underground sites are
reviewed, giving a particular emphasis on their relative strength and
complementarity. A coordination and integration effort among the European Union
underground infrastructures was initiated by the EU-funded ILIAS project and
proved to be very effective.
[10]
oai:arXiv.org:0802.3566 [pdf] - 10378
Neutron- and muon-induced background in underground physics experiments
Submitted: 2008-02-25
Background induced by neutrons in deep underground laboratories is a critical
issue for all experiments looking for rare events, such as dark matter
interactions or neutrinoless 2-beta decay. Neutrons can be produced either by
natural radioactivity, via spontaneous fission or (alpha,n) reactions, or by
interactions initiated by high-energy cosmic rays. In all underground
experiments, Monte Carlo simulations of neutron background play a crucial role
for the evaluation of the total background rate and for the optimization of
rejection strategies. The Monte Carlo methods that are commonly employed to
evaluate neutron-induced background and to optimize the experimental setup, are
reviewed and discussed. Focus is given to the issue of reliability of Monte
Carlo background estimates.
[11]
oai:arXiv.org:astro-ph/0701286 [pdf] - 88415
First results from a Dark Matter search with liquid Argon at 87 K in the
Gran Sasso Underground Laboratory
Benetti, P.;
Acciarri, R.;
Adamo, F.;
Baibussinov, B.;
Baldo-Ceolin, M.;
Belluco, M.;
Calaprice, F.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Centro, S.;
Cocco, A. G.;
Di Pompeo, F.;
Ferrari, N.;
Fiorillo, G.;
Galbiati, C.;
Gallo, V.;
Grandi, L.;
Ianni, A.;
Mangano, G.;
Meng, G.;
Montanari, C.;
Palamara, O.;
Pandola, L.;
Pietropaolo, F.;
Raselli, G. L.;
Rossella, M.;
Rubbia, C.;
Szelc, A. M.;
Ventura, S.;
Vignoli, C.
Submitted: 2007-01-10, last modified: 2007-01-16
A new method of searching for dark matter in the form of weakly interacting
massive particles (WIMP) has been developed with the direct detection of the
low energy nuclear recoils observed in a massive target (ultimately many tons)
of ultra pure Liquid Argon at 87 K. A high selectivity for Argon recoils is
achieved by the simultaneous observation of both the VUV scintillation
luminescence and of the electron signal surviving columnar recombination,
extracted through the liquid-gas boundary by an electric field. First physics
results from this method are reported, based on a small 2.3 litre test chamber
filled with natural Argon and an accumulated fiducial exposure of about 100 kg
x day, supporting the future validity of this method with isotopically purified
40Ar and for a much larger unit presently under construction with
correspondingly increased sensitivities.
[12]
oai:arXiv.org:astro-ph/0603131 [pdf] - 80340
Measurement of the specific activity of Ar-39 in natural argon
Benetti, P.;
Calaprice, F.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Cocco, A. G.;
Di Pompeo, F.;
Ferrari, N.;
Fiorillo, G.;
Galbiati, C.;
Grandi, L.;
Mangano, G.;
Montanari, C.;
Pandola, L.;
Rappoldi, A.;
Raselli, G. L.;
Roncadelli, M.;
Rossella, M.;
Rubbia, C.;
Santorelli, R.;
Szelc, A. M.;
Vignoli, C.;
Zhao, Y.
Submitted: 2006-03-06, last modified: 2007-01-10
We report on the measurement of the specific activity of Ar-39 in natural
argon. The measurement was performed with a 2.3-liter two-phase (liquid and
gas) argon drift chamber. The detector was developed by the WARP Collaboration
as a prototype detector for WIMP Dark Matter searches with argon as a target.
The detector was operated for more than two years at Laboratori Nazionali del
Gran Sasso, Italy, at a depth of 3,400 m w.e. The specific activity measured
for Ar-39 is 1.01 +/- 0.02(stat) +/- 0.08(syst) Bq per kg of natural Ar.
[13]
oai:arXiv.org:hep-ex/0504037 [pdf] - 113362
Complete results for five years of GNO solar neutrino observations
GNO COLLABORATION;
Altmann, M.;
Balata, M.;
Belli, P.;
Bellotti, E.;
Bernabei, R.;
Burkert, E.;
Cattadori, C.;
Cerulli, R.;
Chiarini, M.;
Cribier, M.;
d'Angelo, S.;
Del Re, G.;
Ebert, K. H.;
Feilitzsch, F. v.;
Ferrari, N.;
Hampel, W.;
Hartmann, F. X.;
Henrich, E.;
Heusser, G.;
Kaether, F.;
Kiko, J.;
Kirsten, T.;
Lachenmaier, T.;
Lanfranchi, J.;
Laubenstein, M.;
Luetzenkirchen, K.;
Mayer, K.;
Moegel, P.;
Motta, D.;
Nisi, S.;
Oehm, J.;
Pandola, L.;
Petricca, F.;
Potzel, W.;
Richter, H.;
Schoenert, S.;
Wallenius, M.;
Wojcik, M.;
Zanotti, L.
Submitted: 2005-04-19
We report the complete GNO solar neutrino results for the measuring periods
GNO III, GNO II, and GNO I. The result for GNO III (last 15 solar runs) is
[54.3 + 9.9 - 9.3 (stat.)+- 2.3 (syst.)] SNU (1 sigma) or [54.3 + 10.2 - 9.6
(incl. syst.)] SNU (1 sigma) with errors combined. The GNO experiment is now
terminated after altogether 58 solar exposure runs that were performed between
May 20, 1998 and April 9, 2003. The combined result for GNO (I+II+III) is [62.9
+ 5.5 - 5.3 (stat.) +- 2.5 (syst.)] SNU (1 sigma) or [62.9 + 6.0 - 5.9] SNU (1
sigma) with errors combined in quadrature. Overall, gallium based solar
observations at LNGS (first in GALLEX, later in GNO) lasted from May 14, 1991
through April 9, 2003. The joint result from 123 runs in GNO and GALLEX is
[69.3 +- 5.5 (incl. syst.)] SNU (1 sigma). The distribution of the individual
run results is consistent with the hypothesis of a neutrino flux that is
constant in time. Implications from the data in particle- and astrophysics are
reiterated.