Normalized to: PandaX Collaboration.
[1]
oai:arXiv.org:1505.00771 [pdf] - 1280844
Low-mass dark matter search results from full exposure of PandaX-I
experiment
PandaX Collaboration;
Xiao, Xiang;
Chen, Xun;
Tan, Andi;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl L.;
Gong, Haowei;
Guo, Guodong;
He, Ming;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Lin, Qing;
Liu, Huaxuan;
Liu, Jianglai;
Liu, Xiang;
Lorenzon, Wolfgang;
Ma, Yugang;
Mao, Yajun;
Ni, Kaixuan;
Pushkin, Kirill;
Ren, Xiangxiang;
Schubnell, Michael;
Shen, Manbin;
Shi, Yuji;
Stephenson, Scott;
Wang, Hongwei;
Wang, Jiming;
Wang, Meng;
Wang, Siguang;
Wang, Xuming;
Wang, Zhou;
Wu, Shiyong;
Xiao, Mengjiao;
Xie, Pengwei;
Yan, Binbin;
You, Yinghui;
Zeng, Xionghui;
Zhang, Tao;
Zhao, Li;
Zhou, Xiaopeng;
Zhu, Zhonghua
Submitted: 2015-05-04, last modified: 2015-08-20
We report the results of a weakly-interacting massive particle (WIMP) dark
matter search using the full 80.1\;live-day exposure of the first stage of the
PandaX experiment (PandaX-I) located in the China Jin-Ping Underground
Laboratory. The PandaX-I detector has been optimized for detecting low-mass
WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid
xenon target mass of 54.0\,kg, no significant excess event were found above the
expected background. A profile likelihood analysis confirms our earlier finding
that the PandaX-I data disfavor all positive low-mass WIMP signals reported in
the literature under standard assumptions. A stringent bound on the low mass
WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon
detectors can be competitive for low-mass WIMP searches.
[2]
oai:arXiv.org:1408.5114 [pdf] - 863825
First dark matter search results from the PandaX-I experiment
PandaX Collaboration;
Xiao, Mengjiao;
Xiao, Xiang;
Zhao, Li;
Cao, Xiguang;
Chen, Xun;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl L.;
Gong, Haowei;
Guo, Guodong;
Hu, Jie;
Huang, Xingtao;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Lin, Qing;
Liu, Huaxuan;
Liu, Jianglai;
Liu, Xiang;
Lorenzon, Wolfgang;
Ma, Yugang;
Mao, Yajun;
Ni, Kaixuan;
Pushkin, Kirill;
Ren, Xiangxiang;
Schubnell, Michael;
Shen, Manbing;
Stephenson, Scott;
Tan, Andi;
Tarle, Greg;
Wang, Hongwei;
Wang, Jimin;
Wang, Meng;
Wang, Xuming;
Wang, Zhou;
Wei, Yuehuan;
Wu, Shiyong;
Xie, Pengwei;
You, Yinghui;
Zeng, Xionghui;
Zhang, Hua;
Zhang, Tao;
Zhu, Zhonghua
Submitted: 2014-08-21, last modified: 2014-09-04
We report on the first dark-matter (DM) search results from PandaX-I, a low
threshold dual-phase xenon experiment operating at the China Jinping
Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of
exposure, no DM particle candidate event was found. This result sets a
stringent limit for low-mass DM particles and disfavors the interpretation of
previously-reported positive experimental results. The minimum upper limit,
$3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar
DM-particle-nucleon scattering cross section is obtained at a DM-particle mass
of 49\,GeV/c$^2$ at 90\% confidence level.