Normalized to: Paling, S.
[1]
oai:arXiv.org:1707.09431 [pdf] - 1586535
Measurement of directional range components of nuclear recoil tracks in
a fiducialised dark matter detector
Battat, J. B. R.;
Daw, E. J.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Lee, E. R.;
Loomba, D.;
Lynch, W.;
Miller, E. H.;
Mouton, F.;
Paling, S.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.
Submitted: 2017-07-28
We present results from the first measurement of axial range components of
fiducialized neutron induced nuclear recoil tracks using the DRIFT directional
dark matter detector. Nuclear recoil events are fiducialized in the DRIFT
experiment using temporal charge carrier separations between different species
of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this
measurement, neutron-induced nuclear recoil tracks were generated by exposing
the detector to $^{252}$Cf source from different directions. Using these
events, the sensitivity of the detector to the expected axial directional
signatures were investigated as the neutron source was moved from one detector
axis to another. Results obtained from these measurements show clear
sensitivity of the DRIFT detector to the axial directional signatures in this
fiducialization gas mode.
[2]
oai:arXiv.org:1701.00171 [pdf] - 1564000
Low Threshold Results and Limits from the DRIFT Directional Dark Matter
Detector
Battat, J. B. R.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Paling, S. M.;
Phan, N. S.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Waldram, N.
Submitted: 2016-12-31, last modified: 2017-03-27
We present results from a 54.7 live-day shielded run of the DRIFT-IId
detector, the world's most sensitive, directional, dark matter detector.
Several improvements were made relative to our previous work including a lower
threshold for detection, a more robust analysis and a tenfold improvement in
our gamma rejection factor. After analysis, no events remain in our fiducial
region leading to an exclusion curve for spin-dependent WIMP-proton
interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our
previous work. We also present results from a 45.4 live-day unshielded run of
the DRIFT-IId detector during which 14 nuclear recoil-like events were
observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08
events per day is consistent with detection of ambient, fast neutrons emanating
from the walls of the Boulby Underground Science Facility.
[3]
oai:arXiv.org:1602.05939 [pdf] - 1538892
First search for a dark matter annual modulation signal with NaI(Tl) in
the Southern Hemisphere by DM-Ice17
Collaboration, DM-Ice;
:;
de Souza, E. Barbosa;
Cherwinka, J.;
Cole, A.;
Ezeribe, A. C.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Jo, J. H.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Lim, K. E.;
Macdonald, C.;
Maruyama, R. H.;
Mouton, F.;
Paling, S. M.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Rogers, F. R.;
Sandstrom, P.;
Scarff, A.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2016-02-18, last modified: 2017-02-28
We present the first search for a dark matter annual modulation signal in the
Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17
experiment. Nuclear recoils from dark matter interactions are expected to yield
an annually modulated signal independent of location within the Earth's
hemispheres. DM-Ice17, the first step in the DM-Ice experimental program,
consists of 17 kg of NaI(Tl) located at the South Pole under 2200 m.w.e.
overburden of Antarctic glacial ice. Taken over 3.6 years for a total exposure
of 60.8 kg yr, DM-Ice17 data are consistent with no modulation in the energy
range of 4-20 keV, providing the strongest limits on weakly interacting massive
particle dark matter from a direct detection experiment located in the Southern
Hemisphere. The successful deployment and stable long-term operation of
DM-Ice17 establishes the South Pole ice as a viable location for future dark
matter searches and in particular for a high-sensitivity NaI(Tl) dark matter
experiment to directly test the DAMA/LIBRA claim of the observation of dark
matter.
[4]
oai:arXiv.org:1509.02486 [pdf] - 1364880
Measurement of Muon Annual Modulation and Muon-Induced Phosphorescence
in NaI(Tl) Crystals with DM-Ice17
Collaboration, DM-Ice;
:;
Cherwinka, J.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Lim, K. E.;
Macdonald, C.;
Maruyama, R. H.;
Paling, S.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Sandstrom, P.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2015-09-08, last modified: 2016-02-25
We report the measurement of muons and muon-induced phosphorescence in
DM-Ice17, a NaI(Tl) direct detection dark matter experiment at the South Pole.
Muon interactions in the crystal are identified by their observed pulse shape
and large energy depositions. The measured muon rate in DM-Ice17 is 2.93 +/-
0.04 muons/crystal/day with a modulation amplitude of 12.3 +/- 1.7%, consistent
with expectation. Following muon interactions, we observe long-lived
phosphorescence in the NaI(Tl) crystals with a decay time of 5.5 +/- 0.5 s. The
prompt energy deposited by a muon is correlated to the amount of delayed
phosphorescence, the brightest of which consist of tens of millions of photons.
These photons are distributed over tens of seconds with a rate and arrival
timing that do not mimic a scintillation signal above 2 keVee. While the
properties of phosphorescence vary among individual crystals, the
annually-modulating signal observed by DAMA cannot be accounted for by
phosphorescence with the characteristics observed in DM-Ice17.
[5]
oai:arXiv.org:1410.7821 [pdf] - 1250420
First background-free limit from a directional dark matter experiment:
results from a fully fiducialised DRIFT detector
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Gold, M.;
Harton, J. L.;
Landers, J. M.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Vahsen, S. E.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-10-28, last modified: 2015-07-23
The addition of O2 to gas mixtures in time projection chambers containing CS2
has recently been shown to produce multiple negative ions that travel at
slightly different velocities. This allows a measurement of the absolute
position of ionising events in the z (drift) direction. In this work, we apply
the z-fiducialisation technique to a directional dark matter search. In
particular, we present results from a 46.3 live-day source-free exposure of the
DRIFT-IId detector run in this completely new mode. With full-volume
fiducialisation, we have achieved the first background-free operation of a
directional detector. The resulting exclusion curve for spin-dependent
WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better
than our previous work. We describe the automated analysis used here, and argue
that detector upgrades, implemented after the acquisition of these data, will
bring an additional factor of >3 improvement in the near future.
[6]
oai:arXiv.org:1401.4804 [pdf] - 896930
First data from DM-Ice17
Collaboration, DM-Ice;
:;
Cherwinka, J.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Macdonald, C.;
Maruyama, R. H.;
Paling, S.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Sandstrom, P.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2014-01-20, last modified: 2014-11-13
We report the first analysis of background data from DM-Ice17, a
direct-detection dark matter experiment consisting of 17 kg of NaI(Tl) target
material. It was codeployed with IceCube 2457 m deep in the South Pole glacial
ice in December 2010 and is the first such detector operating in the Southern
Hemisphere. The background rate in the 6.5 - 8.0 keVee region is measured to be
7.9 +/- 0.4 counts/day/keV/kg. This is consistent with the expected background
from the detector assemblies with negligible contributions from the surrounding
ice. The successful deployment and operation of DM-Ice17 establishes the South
Pole ice as a viable location for future underground, low-background
experiments in the Southern Hemisphere. The detector assembly and deployment
are described here, as well as the analysis of the DM-Ice17 backgrounds based
on data from the first two years of operation after commissioning, July 2011 -
June 2013.
[7]
oai:arXiv.org:1407.3938 [pdf] - 1215675
Radon in the DRIFT-II directional dark matter TPC: emanation, detection
and mitigation
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Fox, J. R.;
Gauvreau, J. -L.;
Gold, M.;
Harmon, L. J.;
Harton, J. L.;
Landers, J. M.;
Lee, E. R.;
Loomba, D.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Pipe, M.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-07-15, last modified: 2014-08-25
Radon gas emanating from materials is of interest in environmental science
and also a major concern in rare event non-accelerator particle physics
experiments such as dark matter and double beta decay searches, where it is a
major source of background. Notable for dark matter experiments is the
production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils
of radon daughter isotopes, which can mimic the signal expected from WIMP
interactions. Presented here are results of measurements of radon emanation
from detector materials in the 1 metre cubed DRIFT-II directional dark matter
gas time projection chamber experiment. Construction and operation of a radon
emanation facility for this work is described, along with an analysis to
continuously monitor DRIFT data for the presence of internal 222Rn and 218Po.
Applying this analysis to historical DRIFT data, we show how systematic
substitution of detector materials for alternatives, selected by this device
for low radon emanation, has resulted in a factor of ~10 reduction in internal
radon rates. Levels are found to be consistent with the sum from separate radon
emanation measurements of the internal materials and also with direct
measurement using an attached alpha spectrometer. The current DRIFT detector,
DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 {\mu}Bq/l with current
analysis efficiency, potentially opening up DRIFT technology as a new tool for
sensitive radon assay of materials.
[8]
oai:arXiv.org:1404.2253 [pdf] - 934775
Background Assay and Rejection in DRIFT
Brack, Jeff;
Daw, Ed;
Dorofeev, Alexei;
Ezeribe, Anthony;
Gauvreau, Jean-Luc;
Gold, Michael;
Harton, John;
Lafler, Randy;
Lauer, Robert;
Lee, Eric R.;
Loomba, Dinesh;
Matthews, John;
Miller, Eric H.;
Monte, Alissa;
Murphy, Alex;
Paling, Sean;
Phan, Nguyen;
Sadler, Steve;
Scarff, Andrew;
Snowden-Ifft, Daniel;
Spooner, Neil;
Telfer, Sam;
Walker, Daniel;
Williams, Matt;
Yuriev, Leonid
Submitted: 2014-04-08
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with
directional sensitivity to WIMP-induced nuclear recoils. Its primary
backgrounds were due to alpha decays from contamination on the central cathode.
Efforts to reduce these backgrounds led to replacing the 20 \mu m wire central
cathode with one constructed from 0.9 \mu m aluminized mylar, which is almost
totally transparent to alpha particles. Detailed modeling of the nature and
origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of
alpha decay backgrounds from the central cathode. This led to further
improvements in the thin-film cathode resulting in over 2 orders of magnitude
reduction in backgrounds compared to the wire cathode. Finally, the addition of
O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative
charge carriers, providing a method to determine the absolute position of
nuclear recoils and reject all known remaining backgrounds while retaining a
high efficiency for nuclear recoil detection.
[9]
oai:arXiv.org:1112.1481 [pdf] - 1092209
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Solovov, V. N.;
Belov, V. A.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-12-07, last modified: 2012-09-26
We studied the application of statistical reconstruction algorithms, namely
maximum likelihood and least squares methods, to the problem of event
reconstruction in a dual phase liquid xenon detector. An iterative method was
developed for in-situ reconstruction of the PMT light response functions from
calibration data taken with an uncollimated gamma-ray source. Using the
techniques described, the performance of the ZEPLIN-III dark matter detector
was studied for 122 keV gamma-rays. For the inner part of the detector (R<100
mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the
horizontal plane for primary and secondary scintillation, respectively. An
energy resolution of 8.1% FWHM was achieved at that energy. The possibility of
using this technique for improving performance and reducing cost of
scintillation cameras for medical applications is currently under study.
[10]
oai:arXiv.org:1110.4769 [pdf] - 1085051
WIMP-nucleon cross-section results from the second science run of
ZEPLIN-III
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Bewick, A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Jones, W. G.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-10-21, last modified: 2011-12-16
We report experimental upper limits on WIMP-nucleon elastic scattering cross
sections from the second science run of ZEPLIN-III at the Boulby Underground
Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days
of continuous operation between June 2010 and May 2011. A total of eight events
was observed in the signal acceptance region in the nuclear recoil energy range
7-29 keV, which is compatible with background expectations. This allows the
exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass
with 90% confidence. Combined with data from the first run, this result
improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent
cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its
conclusion at Boulby, having deployed and exploited successfully three liquid
xenon experiments of increasing reach.
[11]
oai:arXiv.org:1111.2248 [pdf] - 1091528
Quenching Factor for Low Energy Nuclear Recoils in a Plastic
Scintillator
Reichhart, L.;
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-11-09
Plastic scintillators are widely used in industry, medicine and scientific
research, including nuclear and particle physics. Although one of their most
common applications is in neutron detection, experimental data on their
response to low-energy nuclear recoils are scarce. Here, the relative
scintillation efficiency for neutron-induced nuclear recoils in a
polystyrene-based plastic scintillator (UPS-923A) is presented, exploring
recoil energies between 125 keV and 850 keV. Monte Carlo simulations,
incorporating light collection efficiency and energy resolution effects, are
used to generate neutron scattering spectra which are matched to observed
distributions of scintillation signals to parameterise the energy-dependent
quenching factor. At energies above 300 keV the dependence is reasonably
described using the semi-empirical formulation of Birks and a kB factor of
(0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured
quenching factor falls more steeply than predicted by the Birks formalism.
[12]
oai:arXiv.org:1110.0222 [pdf] - 967108
The DRIFT Dark Matter Experiments
Daw, E.;
Dorofeev, A.;
Fox, J. R.;
Gauvreau, J. -L.;
Ghag, C.;
Harmon, L. J.;
Harton, J. L.;
Gold, M.;
Lee, E. R.;
Loomba, D.;
Miller, E. H.;
Murphy, A. St. J.;
Paling, S. M.;
Landers, J. M.;
Phan, N.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Sadler, S. W.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Walker, D.;
Warner, D.
Submitted: 2011-10-02
The current status of the DRIFT (Directional Recoil Identification From
Tracks) experiment at Boulby Mine is presented, including the latest limits on
the WIMP spin-dependent cross-section from 1.5 kg days of running with a
mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with
ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale
directional Dark Matter detector.
[13]
oai:arXiv.org:1106.0808 [pdf] - 1077078
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Neves, F.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Rodrigues, S.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-06-04
ZE3RA is the software package responsible for processing the raw data from
the ZEPLIN-III dark matter experiment and its reduction into a set of
parameters used in all subsequent analyses. The detector is a liquid xenon time
projection chamber with scintillation and electroluminescence signals read out
by an array of 31 photomultipliers. The dual range 62-channel data stream is
optimised for the detection of scintillation pulses down to a single
photoelectron and of ionisation signals as small as those produced by single
electrons. We discuss in particular several strategies related to data
filtering, pulse finding and pulse clustering which are tuned to recover the
best electron/nuclear recoil discrimination near the detection threshold, where
most dark matter elastic scattering signatures are expected. The software was
designed assuming only minimal knowledge of the physics underlying the
detection principle, allowing an unbiased analysis of the experimental results
and easy extension to other detectors with similar requirements.
[14]
oai:arXiv.org:1103.0393 [pdf] - 385243
Performance of the veto detector incorporated into the ZEPLIN-III
experiment
Ghag, C.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Lyons, K.;
Majewski, P.;
St, A.;
Murphy, J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-03-02, last modified: 2011-05-01
The ZEPLIN-III experiment is operating in its second phase at the Boulby
Underground Laboratory in search of dark matter WIMPs. The major upgrades to
the instrument over its first science run include lower background
photomultiplier tubes and installation of a plastic scintillator veto system.
Performance results from the veto detector using calibration and science data
in its first six months of operation in coincidence with ZEPLIN-III are
presented. With fully automated operation and calibration, the veto system has
maintained high stability and achieves near unity live time relative to
ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60%
of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be
misidentified as WIMPs. This tagging efficiency reduces the expected untagged
nuclear recoil background from neutrons during science data taking to a very
low rate of ~0.2 events per year in the WIMP acceptance region. Additionally,
the veto detector provides rejection of 28% of gamma-ray induced background
events, allowing the sampling of the dominant source of background in
ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will
not be tagged by the veto detector, and tags due to gamma-rays and neutrons are
separable, this population of multiple scatter events may be characterised
without biasing the analysis of candidate WIMP signals in the data.
[15]
oai:arXiv.org:1010.3027 [pdf] - 345888
Spin-Dependent Limits from the DRIFT-IId Directional Dark Matter
Detector
Daw, E.;
Fox, J. R.;
Gauvreau, J. -L.;
Ghag, C.;
Harmon, L. J.;
Gold, M.;
Lee, E.;
Loomba, D.;
Miller, E.;
Murphy, A. StJ.;
Paling, S. M.;
Landers, J. M.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Walker, D.
Submitted: 2010-10-14, last modified: 2011-04-16
Data are presented from the DRIFT-IId detector housed in the Boulby mine in
northeast England. A 0.8 m^3 fiducial volume, containing partial pressures of
30 Torr CS2 and 10 Torr CF4, was exposed for a duration of 47.4 live-time days
with sufficient passive shielding to provide a neutron free environment within
the detector. The nuclear recoil events seen are consistent with a remaining
low level background from the decay of progeny of radon daughters attached to
the central cathode of the detector. However, energy depositions from such
events must drift across the entire width of the detector, and thus display
large diffusion upon reaching the readout planes of the device. Exploiting this
feature, it is shown to be possible to reject energy depositions from these
radon decay progeny events while still retaining sensitivity to nuclear recoil
events. The response of the detector is then interpreted, using the F nuclei
content of the gas, in terms of sensitivity to proton spin-dependent
WIMP-nucleon interactions, displaying a minimum in sensitivity cross section at
0.5 pb for a WIMP mass of 100 GeV/c^2.
[16]
oai:arXiv.org:1004.4207 [pdf] - 325335
The ZEPLIN-III Anti-Coincidence Veto Detector
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Lyons, K.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Taylor, R.;
Thorne, C.;
Walker, R. J.
Submitted: 2010-04-23, last modified: 2010-04-27
The design, optimisation and construction of an anti-coincidence veto
detector to complement the ZEPLIN-III direct dark matter search instrument is
described. One tonne of plastic scintillator is arranged into 52 bars
individually read out by photomultipliers and coupled to a gadolinium-loaded
passive polypropylene shield. Particular attention has been paid to
radiological content. The overall aim has been to achieve a veto detector of
low threshold and high efficiency without the creation of additional background
in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of
the components have been made, including radioactivity levels and performance
characteristics. These have been used to inform a complete end-to-end Monte
Carlo simulation that has then been used to calculate the expected performance
of the new instrument, both operating alone and as an anti-coincidence detector
for ZEPLIN-III. The veto device will be capable of rejecting over 65% of
coincident nuclear recoil events from neutron background in the energy range of
interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4
to ~0.14 events per year in the WIMP acceptance region, a significant factor in
the event of a non-zero observation. Furthermore, in addition to providing
valuable diagnostic capabilities, the veto is capable of tagging over 15% for
gamma-ray rejection, all whilst contributing no significant additional
background. In conjunction with the replacement of the internal ZEPLIN-III
photomultiplier array, the new veto is expected to improve significantly the
sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin
independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
[17]
oai:arXiv.org:1001.0077 [pdf] - 32338
The LAGUNA design study- towards giant liquid based underground
detectors for neutrino physics and astrophysics and proton decay searches
LAGUNA Collaboration;
Angus, D.;
Ariga, A.;
Autiero, D.;
Apostu, A.;
Badertscher, A.;
Bennet, T.;
Bertola, G.;
Bertola, P. F.;
Besida, O.;
Bettini, A.;
Booth, C.;
Borne, J. L.;
Brancus, I.;
Bujakowsky, W.;
Campagne, J. E.;
Danil, G. Cata;
Chipesiu, F.;
Chorowski, M.;
Cripps, J.;
Curioni, A.;
Davidson, S.;
Declais, Y.;
Drost, U.;
Duliu, O.;
Dumarchez, J.;
Enqvist, T.;
Ereditato, A.;
von Feilitzsch, F.;
Fynbo, H.;
Gamble, T.;
Galvanin, G.;
Gendotti, A.;
Gizicki, W.;
Goger-Neff, M.;
Grasslin, U.;
Gurney, D.;
Hakala, M.;
Hannestad, S.;
Haworth, M.;
Horikawa, S.;
Jipa, A.;
Juget, F.;
Kalliokoski, T.;
Katsanevas, S.;
Keen, M.;
Kisiel, J.;
Kreslo, I.;
Kudryastev, V.;
Kuusiniemi, P.;
Labarga, L.;
Lachenmaier, T.;
Lanfranchi, J. C.;
Lazanu, I.;
Lewke, T.;
Loo, K.;
Lightfoot, P.;
Lindner, M.;
Longhin, A.;
Maalampi, J.;
Marafini, M.;
Marchionni, A.;
Margineanu, R. M.;
Markiewicz, A.;
Marrodan-Undagoita, T.;
Marteau, J. E.;
Matikainen, R.;
Meindl, Q.;
Messina, M.;
Mietelski, J. W.;
Mitrica, B.;
Mordasini, A.;
Mosca, L.;
Moser, U.;
Nuijten, G.;
Oberauer, L.;
Oprina, A.;
Paling, S.;
Pascoli, S.;
Patzak, T.;
Pectu, M.;
Pilecki, Z.;
Piquemal, F.;
Potzel, W.;
Pytel, W.;
Raczynski, M.;
Rafflet, G.;
Ristaino, G.;
Robinson, M.;
Rogers, R.;
Roinisto, J.;
Romana, M.;
Rondio, E.;
Rossi, B.;
Rubbia, A.;
Sadecki, Z.;
Saenz, C.;
Saftoiu, A.;
Salmelainen, J.;
Sima, O.;
Slizowski, J.;
Slizowski, K.;
Sobczyk, J.;
Spooner, N.;
Stoica, S.;
Suhonen, J.;
Sulej, R.;
Szarska, M.;
Szeglowski, T.;
Temussi, M.;
Thompson, J.;
Thompson, L.;
Trzaska, W. H.;
Tippmann, M.;
Tonazzo, A.;
Urbanczyk, K.;
Vasseur, G.;
Williams, A.;
Winter, J.;
Wojutszewska, K.;
Wurm, M.;
Zalewska, A.;
Zampaolo, M.;
Zito, M.
Submitted: 2009-12-30
The feasibility of a next generation neutrino observatory in Europe is being
considered within the LAGUNA design study. To accommodate giant neutrino
detectors and shield them from cosmic rays, a new very large underground
infrastructure is required. Seven potential candidate sites in different parts
of Europe and at several distances from CERN are being studied: Boulby (UK),
Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland),
Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The
design study aims at the comprehensive and coordinated technical assessment of
each site, at a coherent cost estimation, and at a prioritization of the sites
within the summer 2010.
[18]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[19]
oai:arXiv.org:0809.1831 [pdf] - 16182
First measurement of the Head-Tail directional nuclear recoil signature
at energies relevant to WIMP dark matter searches
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. StJ.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-09-10
We present first evidence for the so-called Head-Tail asymmetry signature of
neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the
1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils
induced by Weakly Interacting Massive Particle (WIMPs) but one where the
differential ionization is poorly understood. We show that the distribution of
recoil energies and directions induced here by Cf-252 neutrons matches well
that expected from massive WIMPs. The results open a powerful new means of
searching for a galactic signature from WIMPs.
[20]
oai:arXiv.org:0807.3969 [pdf] - 14845
Measurement of the Range Component Directional Signature in a DRIFT-II
Detector using 252Cf Neutrons
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. St. J.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-07-24
The DRIFT collaboration utilizes low pressure gaseous detectors to search for
WIMP dark matter with directional signatures. A 252Cf neutron source was placed
on each of the principal axes of a DRIFT detector in order to test its ability
to measure directional signatures from the three components of very low energy
(~keV/amu) recoil ranges. A high trigger threshold and the event selection
procedure ensured that only sulfur recoils were analyzed. Sulfur recoils
produced in the CS2 target gas by the 252Cf source closely match those expected
from massive WIMP induced sulfur recoils. For each orientation of the source a
directional signal from the range components was observed, indicating that the
detector is directional along all 3 axes. An analysis of these results yields
an optimal orientation for DRIFT detectors when searching for a directional
signature from WIMPs. Additional energy dependent information is provided to
aid in understanding this effect.
[21]
oai:arXiv.org:astro-ph/0701858 [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase
xenon detector for dark matter detection
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Cashmore, R. J.;
Chagani, H.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Gao, J.;
Ghag, C.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Korolkova, E. V.;
Kudryavtsev, V. A.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Neves, F.;
Nicklin, G. G.;
Ooi, W.;
Paling, S. M.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R. M.;
Quenby, J. J.;
Robinson, M.;
Sergiampietri, F.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F. L. H.
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two phase xenon detector developed to observe nuclear recoils from
hypothetical weakly interacting massive dark matter particles. Discrimination
between nuclear recoils and background electron recoils is afforded by
recording both the scintillation and ionisation signals generated within the
liquid xenon, with the ratio of these signals being different for the two
classes of event. This ratio is calibrated for different incident species using
an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days
of running ZEPLIN-II, the total exposure following the application of fiducial
and stability cuts was 225 kgxdays. A background population of radon progeny
events was observed in this run, arising from radon emission in the gas
purification getters, due to radon daughter ion decays on the surfaces of the
walls of the chamber. An acceptance window, defined by the neutron calibration
data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an
observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray
and radon progeny induced background events. These figures provide a 90% c.l.
upper limit to the number of nuclear recoils of 10.4 events in this acceptance
window, which converts to a WIMP-nucleon spin-independent cross-section with a
minimum of 6.6x10^-7 pb following the inclusion of an energy dependent,
calibrated, efficiency. A second run is currently underway in which the radon
progeny will be eliminated, thereby removing the background population, with a
projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[22]
oai:arXiv.org:astro-ph/0605500 [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and
commissioning
Akimov, D. Yu.;
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Burenkov, A. A.;
Carson, M. J.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Chag, C.;
Hollingworth, R. J.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Kuznetsov, I. S.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G. G.;
Paling, S. M.;
Muna, D.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F.
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
[23]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.
[24]
oai:arXiv.org:hep-ex/0109013 [pdf] - 363345
Study and suppression of anomalous fast events in inorganic
scintillators for dark matter searches
Kudryavtsev, V. A.;
Spooner, N. J. C.;
Lightfoot, P. K.;
Roberts, J. W.;
Lehner, M. J.;
Gamble, T.;
Carson, M. J.;
Lawson, T. B.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Paling, S. M.;
Robinson, M.;
Tovey, D. R.;
Smith, N. J. T.;
Smith, P. F.;
Alner, G. J.;
Hart, S. P.;
Lewin, J. D.;
Preece, R. M.;
Sumner, T. J.;
Jones, W. G.;
Quenby, J. J.;
Ahmed, B.;
Bewick, A.;
Davidge, D.;
Dawson, J. V.;
Howard, A. S.;
Ivaniouchenkov, I.;
Joshi, M. K.;
Lebedenko, V.;
Liubarsky, I.;
Barton, J. C.;
Gerbier, G.;
Mallet, J.;
Mosca, L.;
Tao, C.
Submitted: 2001-09-12
The status of dark matter searches with inorganic scintillator detectors at
Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are
presented. The objectives of the latter experiment were to study anomalous fast
events previously observed and to identify ways to remove this background.
Clear indications were found that these events were due to surface
contamination of crystals by alphas, probably from radon decay. A new array of
unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure
nitrogen atmosphere is under construction at Boulby. Such an approach allows
complete control of the surface of the crystals and the ability to remove any
surface contamination. First data from the unencapsulated NaI(Tl) do not show
the presence of anomalous fast events.