Normalized to: Palaio, N.
[1]
oai:arXiv.org:1801.06991 [pdf] - 1678531
Commercialization of micro-fabrication of antenna-coupled Transition
Edge Sensor bolometer detectors for studies of the Cosmic Microwave
Background
Submitted: 2018-01-22
We report on the development of commercially fabricated multi-chroic antenna
coupled Transition Edge Sensor (TES) bolometer arrays for Cosmic Microwave
Background (CMB) polarimetry experiments. CMB polarimetry experiments have
deployed instruments in stages. Stage-II experiments deployed with O(1,000)
detectors and reported successful detection of B-mode (divergent free)
polarization pattern in the CMB. Stage-III experiments have recently started
observing with O(10,000) detectors with wider frequency coverage. A concept for
a Stage-IV experiment, CMB-S4, is emerging to make a definitive measurement of
CMB polarization from the ground with O(400,000) detectors. The orders of
magnitude increase in detector count for CMB-S4 requires a new approach in
detector fabrication to increase fabrication throughput.and reduce cost. We
report on collaborative efforts with two commercial micro-fabrication foundries
to fabricate antenna coupled TES bolometer detectors. The detector design is
based on the sinuous antenna coupled dichroic detector from the POLARBEAR-2
experiment. The TES bolometers showed the expected I-V response and the RF
performance agrees with simulation. We will discuss the motivation, design
consideration, fabrication processes, test results, and how industrial detector
fabrication could be a path to fabricate hundreds of detector wafers for future
CMB polarimetry experiments.
[2]
oai:arXiv.org:0711.2105 [pdf] - 900223
Radiation Tolerance of Fully-Depleted P-Channel CCDs Designed for the
SNAP Satellite
Dawson, Kyle;
Bebek, Chris;
Emes, John;
Holland, Steve;
Jelinsky, Sharon;
Karcher, Armin;
Kolbe, William;
Palaio, Nick;
Roe, Natalie;
Saha, Juhi;
Takasaki, Koki;
Wang, Guobin
Submitted: 2007-11-13
Thick, fully depleted p-channel charge-coupled devices (CCDs) have been
developed at the Lawrence Berkeley National Laboratory (LBNL). These CCDs have
several advantages over conventional thin, n-channel CCDs, including enhanced
quantum efficiency and reduced fringing at near-infrared wavelengths and
improved radiation tolerance. Here we report results from the irradiation of
CCDs with 12.5 and 55 MeV protons at the LBNL 88-Inch Cyclotron and with 0.1-1
MeV electrons at the LBNL Co60 source. These studies indicate that the LBNL
CCDs perform well after irradiation, even in the parameters in which
significant degradation is observed in other CCDs: charge transfer efficiency,
dark current, and isolated hot pixels. Modeling the radiation exposure over a
six-year mission lifetime with no annealing, we expect an increase in dark
current of 20 e/pixel/hr, and a degradation of charge transfer efficiency in
the parallel direction of 3e-6 and 1e-6 in the serial direction. The dark
current is observed to improve with an annealing cycle, while the parallel CTE
is relatively unaffected and the serial CTE is somewhat degraded. As expected,
the radiation tolerance of the p-channel LBNL CCDs is significantly improved
over the conventional n-channel CCDs that are currently employed in space-based
telescopes such as the Hubble Space Telescope.
[3]
oai:arXiv.org:astro-ph/0405232 [pdf] - 64752
Supernova / Acceleration Probe: A Satellite Experiment to Study the
Nature of the Dark Energy
SNAP Collaboration;
Aldering, G.;
Althouse, W.;
Amanullah, R.;
Annis, J.;
Astier, P.;
Baltay, C.;
Barrelet, E.;
Basa, S.;
Bebek, C.;
Bergstrom, L.;
Bernstein, G.;
Bester, M.;
Bigelow, B.;
Blandford, R.;
Bohlin, R.;
Bonissent, A.;
Bower, C.;
Brown, M.;
Campbell, M.;
Carithers, W.;
Commins, E.;
Craig, W.;
Day, C.;
DeJongh, F.;
Deustua, S.;
Diehl, T.;
Dodelson, S.;
Ealet, A.;
Ellis, R.;
Emmet, W.;
Fouchez, D.;
Frieman, J.;
Fruchter, A.;
Gerdes, D.;
Gladney, L.;
Goldhaber, G.;
Goobar, A.;
Groom, D.;
Heetderks, H.;
Hoff, M.;
Holland, S.;
Huffer, M.;
Hui, L.;
Huterer, D.;
Jain, B.;
Jelinsky, P.;
Karcher, A.;
Kent, S.;
Kahn, S.;
Kim, A.;
Kolbe, W.;
Krieger, B.;
Kushner, G.;
Kuznetsova, N.;
Lafever, R.;
Lamoureux, J.;
Lampton, M.;
Fevre, O. Le;
Levi, M.;
Limon, P.;
Lin, H.;
Linder, E.;
Loken, S.;
Lorenzon, W.;
Malina, R.;
Marriner, J.;
Marshall, P.;
Massey, R.;
Mazure, A.;
McKay, T.;
McKee, S.;
Miquel, R.;
Morgan, N.;
Mortsell, E.;
Mostek, N.;
Mufson, S.;
Musser, J.;
Nugent, P.;
Oluseyi, H.;
Pain, R.;
Palaio, N.;
Pankow, D.;
Peoples, J.;
Perlmutter, S.;
Prieto, E.;
Rabinowitz, D.;
Refregier, A.;
Rhodes, J.;
Roe, N.;
Rusin, D.;
Scarpine, V.;
Schubnell, M.;
Sholl, M.;
Smadja, G.;
Smith, R. M.;
Smoot, G.;
Snyder, J.;
Spadafora, A.;
Stebbins, A.;
Stoughton, C.;
Szymkowiak, A.;
Tarle, G.;
Taylor, K.;
Tilquin, A.;
Tomasch, A.;
Tucker, D.;
Vincent, D.;
von der Lippe, H.;
Walder, J-P.;
Wang, G.;
Wester, W.
Submitted: 2004-05-12
The Supernova / Acceleration Probe (SNAP) is a proposed space-based
experiment designed to study the dark energy and alternative explanations of
the acceleration of the Universe's expansion by performing a series of
complementary systematics-controlled measurements. We describe a
self-consistent reference mission design for building a Type Ia supernova
Hubble diagram and for performing a wide-area weak gravitational lensing study.
A 2-m wide-field telescope feeds a focal plane consisting of a 0.7
square-degree imager tiled with equal areas of optical CCDs and near infrared
sensors, and a high-efficiency low-resolution integral field spectrograph. The
SNAP mission will obtain high-signal-to-noise calibrated light-curves and
spectra for several thousand supernovae at redshifts between z=0.1 and 1.7. A
wide-field survey covering one thousand square degrees resolves ~100 galaxies
per square arcminute. If we assume we live in a cosmological-constant-dominated
Universe, the matter density, dark energy density, and flatness of space can
all be measured with SNAP supernova and weak-lensing measurements to a
systematics-limited accuracy of 1%. For a flat universe, the
density-to-pressure ratio of dark energy can be similarly measured to 5% for
the present value w0 and ~0.1 for the time variation w'. The large survey area,
depth, spatial resolution, time-sampling, and nine-band optical to NIR
photometry will support additional independent and/or complementary dark-energy
measurement approaches as well as a broad range of auxiliary science programs.
(Abridged)