sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Pagan, L.

Normalized to: Pagan, L.

5 article(s) in total. 134 co-authors, from 1 to 5 common article(s). Median position in authors list is 32,0.

[1]  oai:arXiv.org:1005.2541  [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Comments: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysics
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
[2]  oai:arXiv.org:1001.4711  [pdf] - 33175
The Planck-LFI flight model composite waveguides
Comments: this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
Submitted: 2010-01-26
The Low Frequency Instrument on board the PLANCK satellite is designed to give the most accurate map ever of the CMB anisotropy of the whole sky over a broad frequency band spanning 27 to 77 GHz. It is made of an array of 22 pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between the two parts is made with rectangular Wave Guides. Considerations of different nature (thermal, electromagnetic and mechanical), imposed stringent requirements on the WGs characteristics and drove their design. From the thermal point of view, the WG should guarantee good insulation between the FEM and the BEM sections to avoid overloading the cryocooler. On the other hand it is essential that the signals do not undergo excessive attenuation through the WG. Finally, given the different positions of the FEM modules behind the focal surface and the mechanical constraints given by the surrounding structures, different mechanical designs were necessary. A composite configuration of Stainless Steel and Copper was selected to satisfy all the requirements. Given the complex shape and the considerable length (about 1.5-2 m), manufacturing and testing the WGs was a challenge. This work deals with the development of the LFI WGs, including the choice of the final configuration and of the fabrication process. It also describes the testing procedure adopted to fully characterize these components from the electromagnetic point of view and the space qualification process they underwent. Results obtained during the test campaign are reported and compared with the stringent requirements. The performance of the LFI WGs is in line with requirements, and the WGs were successfully space qualified.
[3]  oai:arXiv.org:1001.4778  [pdf] - 33192
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Comments: This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at [10.1088/1748-0221/4/12/T12006]. 14 pages, 34 figures
Submitted: 2010-01-26
The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal horns, one for each radiometer, 22 in total, facing small absorbing targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately 4.5 K. Horns and targets are separated by a small gap to allow thermal decoupling. Target and horn design is optimized for each of the LFI bands, centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the radiometer 20K module or connected via external electro-formed bended waveguides. The requirement of high stability of the reference signal imposed a careful design for the radiometric and thermal properties of the loads. Materials used for the manufacturing have been characterized for thermal, RF and mechanical properties. We describe in this paper the design and the performance of the reference system.
[4]  oai:arXiv.org:1001.4562  [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Comments: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010)
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
[5]  oai:arXiv.org:1001.3321  [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency Instrument
Bersanelli, M.; Mandolesi, N.; Butler, R. C.; Mennella, A.; Villa, F.; Aja, B.; Artal, E.; Artina, E.; Baccigalupi, C.; Balasini, M.; Baldan, G.; Banday, A.; Bastia, P.; Battaglia, P.; Bernardino, T.; Blackhurst, E.; Boschini, L.; Burigana, C.; Cafagna, G.; Cappellini, B.; Cavaliere, F.; Colombo, F.; Crone, G.; Cuttaia, F.; D'Arcangelo, O.; Danese, L.; Davies, R. D.; Davis, R. J.; De Angelis, L.; De Gasperis, G. C.; De La Fuente, L.; De Rosa, A.; De Zotti, G.; Falvella, M. C.; Ferrari, F.; Ferretti, R.; Figini, L.; Fogliani, S.; Franceschet, C.; Franceschi, E.; Gaier, T.; Garavaglia, S.; Gomez, F.; Gorski, K.; Gregorio, A.; Guzzi, P.; Herreros, J. M.; Hildebrandt, S. R.; Hoyland, R.; Hughes, N.; Janssen, M.; Jukkala, P.; Kettle, D.; Kilpia, V. H.; Laaninen, M.; Lapolla, P. M.; Lawrence, C. R.; Leahy, J. P.; Leonardi, R.; Leutenegger, P.; Levin, S.; Lilje, P. B.; Lowe, S. R.; Lubin, D. Lawson P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Mediavilla, A.; Meinhold, P.; Miccolis, M.; Morgante, G.; Natoli, P.; Nesti, R.; Pagan, L.; Paine, C.; Partridge, B.; Pascual, J. P.; Pasian, F.; Pearson, D.; Pecora, M.; Perrotta, F.; Platania, P.; Pospieszalski, M.; Poutanen, T.; Prina, M.; Rebolo, R.; Roddis, N.; Rubino-Martin, J. A.; Salmon, n M. J.; Sandri, M.; Seiffert, M.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Taddei, E.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Valenziano, L.; Varis, J.; Vittorio, N.; Wade, L. A.; Wilkinson, A.; Winder, F.; Zacchei, A.; Zonca, A.
Comments: 23 pages, 31 figures, accepted by Astronomy and Astrophysics, Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.