sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Orrell, J. L.

Normalized to: Orrell, J.

19 article(s) in total. 673 co-authors, from 1 to 10 common article(s). Median position in authors list is 50,0.

[1]  oai:arXiv.org:2005.14067  [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration; Amaral, D. W.; Aralis, T.; Aramaki, T.; Arnquist, I. J.; Azadbakht, E.; Banik, S.; Barker, D.; Bathurst, C.; Bauer, D. A.; Bezerra, L. V. S.; Bhattacharyya, R.; Binder, T.; Bowles, M. A.; Brink, P. L.; Bunker, R.; Cabrera, B.; Calkins, R.; Cameron, R. A.; Cartaro, C.; Cerdeño, D. G.; Chang, Y. -Y.; Chen, R.; Chott, N.; Cooley, J.; Coombes, H.; Corbett, J.; Cushman, P.; De Brienne, F.; di Vacri, M. L.; Diamond, M. D.; Fascione, E.; Figueroa-Feliciano, E.; Fink, C. W.; Fouts, K.; Fritts, M.; Gerbier, G.; Germond, R.; Ghaith, M.; Golwala, S. R.; Harris, H. R.; Herbert, N.; Hines, B. A.; Hollister, M. I.; Hong, Z.; Hoppe, E. W.; Hsu, L.; Huber, M. E.; Iyer, V.; Jardin, D.; Jastram, A.; Kelsey, M. H.; Kubik, A.; Kurinsky, N. A.; Lawrence, R. E.; Li, A.; Loer, B.; Asamar, E. Lopez; Lukens, P.; MacDonell, D.; MacFarlane, D. B.; Mahapatra, R.; Mandic, V.; Mast, N.; Mayer, A. J.; Michaud, É. M.; Michielin, E.; Mirabolfathi, N.; Mohanty, B.; Mendoza, J. D. Morales; Nagorny, S.; Nelson, J.; Neog, H.; Novati, V.; Orrell, J. L.; Oser, S. M.; Page, W. A.; Pakarha, P.; Partridge, R.; Podviianiuk, R.; Ponce, F.; Poudel, S.; Pyle, M.; Rau, W.; Reid, E.; Ren, R.; Reynolds, T.; Roberts, A.; Robinson, A. E.; Rogers, H. E.; Saab, T.; Sadoulet, B.; Sander, J.; Sattari, A.; Schnee, R. W.; Scorza, S.; Serfass, B.; Sincavage, D. J.; Stanford, C.; Stein, M.; Street, J.; Toback, D.; Underwood, R.; Verma, S.; Villano, A. N.; von Krosigk, B.; Watkins, S. L.; Wills, L.; Wilson, J. S.; Wilson, M. J.; Winchell, J.; Wright, D. H.; Yellin, S.; Young, B. A.; Yu, T. C.; Zhang, E.; Zhang, H. G.; Zhao, X.; Zheng, L.
Comments: 5 pages + title and references, 3 figures and 1 table
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]  oai:arXiv.org:1806.07043  [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Comments: 14 pages, 10 figures, 5 tables. v5 contains the extended data release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]  oai:arXiv.org:1903.03663  [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.; Giampa, P.; Retiere, F.; Kroeger, J.; Zhang, G.; Ward, M.; Margetak, P.; Lic, G.; Tsang, T.; Doria, L.; Kharusi, S. Al; Alfaris, M.; Anton, G.; Arnquist, I. J.; Badhrees, I.; Barbeau, P. S.; Beck, D.; Belov, V.; Bhatta, T.; Blatchford, J.; Brodsky, J. P.; Brown, E.; Brunner, T.; Cao, G. F.; Cao, L.; Cen, W. R.; Chambers, C.; Charlebois, S. A.; Chiu, M.; Cleveland, B.; Coon, M.; Craycraft, A.; Dalmasson, J.; Daniels, T.; Darroch, L.; Daugherty, S. J.; Croix, A. De St.; Der Mesrobian-Kabakian, A.; DeVoe, R.; Dilling, J.; Ding, Y. Y.; Dolinski, M. J.; Dragone, A.; Echevers, J.; Elbeltagi, M.; Fabris, L.; Fairbank, D.; Fairbank, W.; Farine, J.; Feyzbakhsh, S.; Fontaine, R.; Gautam, P.; Giacomini, G.; Gornea, R.; Gratta, G.; Hansen, E. V.; Heffner, M.; Hoppe, E. W.; Hoßl, J.; House, A.; Hughes, M.; Ito, Y.; Iverson, A.; Jamil, A.; Jewell, M. J.; Jiang, X. S.; Karelin, A.; Kaufman, L. J.; Kodroff, D.; Koffas, T.; Krucken, R.; Kuchenkov, A.; Kumar, K. S.; Lana, Y.; Larson, A.; Lenardo, B. G.; Leonarda, D. S.; Lik, S.; Li, Z.; Licciardi, C.; Linw, Y. H.; Lv, P.; MacLellan, R.; McElroy, T.; Medina-Peregrina, M.; Michel, T.; Mong, B.; Moore, D. C.; Murray, K.; Nakarmi, P.; Newby, R. J.; Ning, Z.; Njoya, O.; Nolet, F.; Nusair, O.; Odgers, K.; Odian, A.; Oriunno, M.; Orrell, J. L.; Ortega, G. S.; Ostrovskiy, I.; Overman, C. T.; Parent, S.; Piepkez, A.; Pocar, A.; Pratte, J. -F.; Qiu, D.; Radeka, V.; Raguzin, E.; Rescia, S.; Richman, M.; Robinson, A.; Rossignol, T.; Rowson, P. C.; Roy, N.; Saldanha, R.; Sangiorgio, S.; VIII, K. Skarpaas; Soma, A. K.; St-Hilaire, G.; Stekhanov, V.; Stiegler, T.; Sun, X. L.; Tarka, M.; Todd, J.; Tolba, T.; Totev, T. I.; Tsang, R.; Vachon, F.; Veeraraghavan, V.; Visser, G.; Vuilleumier, J. -L.; Wagenpfeil, M.; Walent, M.; Wang, Q.; Watkins, J.; Weber, M.; Wei, W.; Wen, L. J.; Wichoski, U.; Wu, S. X.; Wu, W. H.; Wu, X.; Xia, Q.; Yang, H.; Yang, L.; Yen, Y. -R.; Zeldovich, O.; Zhao, J.; Zhou, Y.; Ziegler, T.
Comments:
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[4]  oai:arXiv.org:1804.10697  [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Comments: 6 pages + title and references, 6 figures, includes erratum submitted to PRL and data release
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
[5]  oai:arXiv.org:1808.09098  [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Comments:
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
[6]  oai:arXiv.org:1805.09942  [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Agnese, Robert; Aralis, Taylor; Aramaki, Tsuguo; Arnquist, Isaac; Azadbakht, Elham; Baker, William; Banik, Samir; Barker, D'Ann; Bauer, Dan; Binder, Thomas; Bowles, Michael; Brink, Paul; Bunker, Ray; Cabrera, Blas; Calkins, Robert; Cartaro, Concetta; Cerdeno, David; Chang, Yen-Yung; Cooley, Jodi; Cornell, Brett; Cushman, Priscilla; Di Stefano, Philippe; Doughty, Todd; Fascione, Eleanor; Figueroa, Tali; Fink, Caleb; Fritts, Matt; Gerbier, Gilles; Germond, Richard; Ghaith, Muad; Golwala, Sunil; Harris, Rusty; Hong, Ziqing; Hoppe, Eric; Hsu, Lauren; Huber, Martin; Iyer, Vijay; Jardin, Dan; Jena, Chitrasen; Kelsey, Michael; Kennedy, Allison; Kubik, Andrew; Kurinsky, Noah; Lawrence, Richard; Loer, Ben; Lopez-Asamar, Elias; Lukens, Pat; MacDonell, Danika; Mahapatra, Rupak; Mandic, Vuk; Mast, Nicholas; Miller, Eric; Mirabolfathi, Nader; Mohanty, Bedangadas; Morales, Jorge; Nelson, Jack; Orrell, John; Oser, Scott; Page, William; Partridge, Richard; Pepin, Mark; Ponce, Francisco; Poudel, Sudip; Pyle, Matt; Qiu, Hang; Rau, Wolfgang; Reisetter, Angela; Ren, Tom; Reynolds, Tyler; Roberts, Amy; Robinson, Alan; Rogers, Hannah; Saab, Tarek; Sadoulet, Bernard; Sander, Joel; Scarff, Andrew; Schnee, Richard; Scorza, Silvia; Senapati, Kartik; Serfass, Bruno; Speller, Danielle; Stein, Matthew; Street, Joseph; Tanaka, Hirohisa; Toback, David; Underwood, Ryan; Villano, Anthony; von Krosigk, Belina; Watkins, Samuel; Wilson, Jon; Wilson, Matthew; Winchell, Joshua; Wright, Dennis; Yellin, Steve; Young, Betty; Zhang, Xiaohe; Zhao, Xuji
Comments: 4 Figures, Two data files, One data release description file
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
[7]  oai:arXiv.org:1707.01632  [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
Comments: 30 Pages, 33 Figures v3 to match published version in PRD. v2 contains public release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
[8]  oai:arXiv.org:1707.04591  [pdf] - 1585955
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Battaglieri, Marco; Belloni, Alberto; Chou, Aaron; Cushman, Priscilla; Echenard, Bertrand; Essig, Rouven; Estrada, Juan; Feng, Jonathan L.; Flaugher, Brenna; Fox, Patrick J.; Graham, Peter; Hall, Carter; Harnik, Roni; Hewett, JoAnne; Incandela, Joseph; Izaguirre, Eder; McKinsey, Daniel; Pyle, Matthew; Roe, Natalie; Rybka, Gray; Sikivie, Pierre; Tait, Tim M. P.; Toro, Natalia; Van De Water, Richard; Weiner, Neal; Zurek, Kathryn; Adelberger, Eric; Afanasev, Andrei; Alexander, Derbin; Alexander, James; Antochi, Vasile Cristian; Asner, David Mark; Baer, Howard; Banerjee, Dipanwita; Baracchini, Elisabetta; Barbeau, Phillip; Barrow, Joshua; Bastidon, Noemie; Battat, James; Benson, Stephen; Berlin, Asher; Bird, Mark; Blinov, Nikita; Boddy, Kimberly K.; Bondi, Mariangela; Bonivento, Walter M.; Boulay, Mark; Boyce, James; Brodeur, Maxime; Broussard, Leah; Budnik, Ranny; Bunting, Philip; Caffee, Marc; Caiazza, Sabato Stefano; Campbell, Sheldon; Cao, Tongtong; Carosi, Gianpaolo; Carpinelli, Massimo; Cavoto, Gianluca; Celentano, Andrea; Chang, Jae Hyeok; Chattopadhyay, Swapan; Chavarria, Alvaro; Chen, Chien-Yi; Clark, Kenneth; Clarke, John; Colegrove, Owen; Coleman, Jonathon; Cooke, David; Cooper, Robert; Crisler, Michael; Crivelli, Paolo; D'Eramo, Francesco; D'Urso, Domenico; Dahl, Eric; Dawson, William; De Napoli, Marzio; De Vita, Raffaella; DeNiverville, Patrick; Derenzo, Stephen; Di Crescenzo, Antonia; Di Marco, Emanuele; Dienes, Keith R.; Diwan, Milind; Dongwi, Dongwi Handiipondola; Drlica-Wagner, Alex; Ellis, Sebastian; Ezeribe, Anthony Chigbo; Farrar, Glennys; Ferrer, Francesc; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fiorillo, Giuliana; Fornal, Bartosz; Freyberger, Arne; Frugiuele, Claudia; Galbiati, Cristian; Galon, Iftah; Gardner, Susan; Geraci, Andrew; Gerbier, Gilles; Graham, Mathew; Gschwendtner, Edda; Hearty, Christopher; Heise, Jaret; Henning, Reyco; Hill, Richard J.; Hitlin, David; Hochberg, Yonit; Hogan, Jason; Holtrop, Maurik; Hong, Ziqing; Hossbach, Todd; Humensky, T. B.; Ilten, Philip; Irwin, Kent; Jaros, John; Johnson, Robert; Jones, Matthew; Kahn, Yonatan; Kalantarians, Narbe; Kaplinghat, Manoj; Khatiwada, Rakshya; Knapen, Simon; Kohl, Michael; Kouvaris, Chris; Kozaczuk, Jonathan; Krnjaic, Gordan; Kubarovsky, Valery; Kuflik, Eric; Kusenko, Alexander; Lang, Rafael; Leach, Kyle; Lin, Tongyan; Lisanti, Mariangela; Liu, Jing; Liu, Kun; Liu, Ming; Loomba, Dinesh; Lykken, Joseph; Mack, Katherine; Mans, Jeremiah; Maris, Humphrey; Markiewicz, Thomas; Marsicano, Luca; Martoff, C. J.; Mazzitelli, Giovanni; McCabe, Christopher; McDermott, Samuel D.; McDonald, Art; McKinnon, Bryan; Mei, Dongming; Melia, Tom; Miller, Gerald A.; Miuchi, Kentaro; Nazeer, Sahara Mohammed Prem; Moreno, Omar; Morozov, Vasiliy; Mouton, Frederic; Mueller, Holger; Murphy, Alexander; Neilson, Russell; Nelson, Tim; Neu, Christopher; Nosochkov, Yuri; O'Hare, Ciaran; Oblath, Noah; Orrell, John; Ouellet, Jonathan; Pastore, Saori; Paul, Sebouh; Perelstein, Maxim; Peter, Annika; Phan, Nguyen; Phinney, Nan; Pivovaroff, Michael; Pocar, Andrea; Pospelov, Maxim; Pradler, Josef; Privitera, Paolo; Profumo, Stefano; Raggi, Mauro; Rajendran, Surjeet; Randazzo, Nunzio; Raubenheimer, Tor; Regenfus, Christian; Renshaw, Andrew; Ritz, Adam; Rizzo, Thomas; Rosenberg, Leslie; Rubbia, Andre; Rybolt, Ben; Saab, Tarek; Safdi, Benjamin R.; Santopinto, Elena; Scarff, Andrew; Schneider, Michael; Schuster, Philip; Seidel, George; Sekiya, Hiroyuki; Seong, Ilsoo; Simi, Gabriele; Sipala, Valeria; Slatyer, Tracy; Slone, Oren; Smith, Peter F; Smolinsky, Jordan; Snowden-Ifft, Daniel; Solt, Matthew; Sonnenschein, Andrew; Sorensen, Peter; Spooner, Neil; Srivastava, Brijesh; Stancu, Ion; Strigari, Louis; Strube, Jan; Sushkov, Alexander O.; Szydagis, Matthew; Tanedo, Philip; Tanner, David; Tayloe, Rex; Terrano, William; Thaler, Jesse; Thomas, Brooks; Thorpe, Brianna; Thorpe, Thomas; Tiffenberg, Javier; Tran, Nhan; Trovato, Marco; Tully, Christopher; Tyson, Tony; Vachaspati, Tanmay; Vahsen, Sven; van Bibber, Karl; Vandenbroucke, Justin; Villano, Anthony; Volansky, Tomer; Wang, Guojian; Ward, Thomas; Wester, William; Whitbeck, Andrew; Williams, David A.; Wing, Matthew; Winslow, Lindley; Wojtsekhowski, Bogdan; Yu, Hai-Bo; Yu, Shin-Shan; Yu, Tien-Tien; Zhang, Xilin; Zhao, Yue; Zhong, Yi-Ming
Comments: 102 pages + references
Submitted: 2017-07-14
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
[9]  oai:arXiv.org:1610.00006  [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Comments: SuperCDMS SNOLAB Projected sensitivity reach
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
[10]  oai:arXiv.org:1401.6234  [pdf] - 931856
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of CoGeNT Data
Comments: 10 pages, 11 figures. Submitted to Phys. Rev. D
Submitted: 2014-01-23, last modified: 2015-02-05
CoGeNT has taken data for over 3 years, with 1136 live days of data accumulated as of April 23, 2013. We report on the results of a maximum likelihood analysis to extract any possible dark matter signal present in the collected data. The maximum likelihood signal extraction uses 2-dimensional probability density functions (PDFs) to characterize the anticipated variations in dark matter interaction rates for given observable nuclear recoil energies during differing periods of the Earth's annual orbit around the Sun. Cosmogenic and primordial radioactivity backgrounds are characterized by their energy signatures and in some cases decay half-lives. A third parameterizing variable -- pulse rise-time -- is added to the likelihood analysis to characterize slow rising pulses described in prior analyses. The contribution to each event category is analyzed for various dark matter signal hypotheses including a dark matter standard halo model and a case with free oscillation parameters (i.e., amplitude, period, and phase). The best-fit dark matter signal is in close proximity to previously reported results. We find that the significance of the extracted dark matter signal remains well below evidentiary at 1.7 $\sigma$.
[11]  oai:arXiv.org:1407.7524  [pdf] - 903589
Coherent neutrino-nucleus scattering detection with a CsI[Na] scintillator at the SNS spallation source
Comments: v2: minor corrections
Submitted: 2014-07-28, last modified: 2014-08-20
We study the possibility of using CsI[Na] scintillators as an advantageous target for the detection of coherent elastic neutrino-nucleus scattering (CENNS), using the neutrino emissions from the SNS spallation source at Oak Ridge National Laboratory. The response of this material to low-energy nuclear recoils like those expected from this process is characterized. Backgrounds are studied using a 2 kg low-background prototype crystal in a dedicated radiation shield. The conclusion is that a planned 14 kg detector should measure approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr low-energy threshold, with a signal-to-background ratio sufficient for a first measurement of the CENNS cross-section. The cross-section for the $^{208}$Pb($\nu_{e},e^{-}$)$^{208}$Bi reaction, of interest for future supernova neutrino detection, can be simultaneously obtained.
[12]  oai:arXiv.org:1403.0475  [pdf] - 797476
A search for bremsstrahlung solar axions using the Majorana low-background BEGe detector at Kimballton (MALBEK)
Comments: This paper has been withdrawn by the authors. Recent results we were not aware of should be taken into account
Submitted: 2014-03-03, last modified: 2014-03-17
A low-background, high-purity germanium detector has been used to search for evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ model axions to electrons. The prospects for the sensitivity of the Majorana Demonstrator array of point-contact germanium detectors to solar axions are discussed in the context of the model-independent annual modulation due to the seasonal variation of the earth-sun distance.
[13]  oai:arXiv.org:1401.3295  [pdf] - 770398
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data
Comments: Three datasets and note on usage included as ancillary files
Submitted: 2014-01-14
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a region of the energy spectrum populated by an exponential excess of unknown origin. Its phase and period agree with phenomenological expectations, but its amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP galactic halo. We consider the possibility of a non-Maxwellian local halo velocity distribution as a plausible explanation, able to help reconcile recently reported WIMP search anomalies.
[14]  oai:arXiv.org:1310.8327  [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Comments: Snowmass CF1 Final Summary Report: 47 pages and 28 figures with a 5 page appendix on instrumentation R&D
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
[15]  oai:arXiv.org:1208.5737  [pdf] - 690015
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
Comments: 20 pages, 31 figures. Several figures have been added, including an updated allowed region (both 90% and 99% confidence level contours) based on this analysis. There is also the addition of a Pb-210 background estimate
Submitted: 2012-08-28, last modified: 2013-04-29
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instrumental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. Extensive simulations of all presently known backgrounds do not provide a viable background explanation for the excess of low-energy events in the CoGeNT data, or the previously observed temporal variation in the event rate. Also reported on for the first time is a determination of the surface (slow pulse rise time) event contamination in the data as a function of energy. We conclude that the CoGeNT detector technology is well suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA results
[16]  oai:arXiv.org:1210.6282  [pdf] - 1152380
The C-4 Dark Matter Experiment
Comments: 19 pages, 7 figures
Submitted: 2012-10-23, last modified: 2013-02-07
We describe the experimental design of C-4, an expansion of the CoGeNT dark matter search to four identical detectors each approximately three times the mass of the p-type point contact germanium diode presently taking data at the Soudan Underground Laboratory. Expected reductions of radioactive backgrounds and energy threshold are discussed, including an estimate of the additional sensitivity to low-mass dark matter candidates to be obtained with this search.
[17]  oai:arXiv.org:1106.0650  [pdf] - 669552
Search for an Annual Modulation in a P-type Point Contact Germanium Dark Matter Detector
Comments: Published version, slightly expanded discussion of ROI uncertainties, one reference added
Submitted: 2011-06-03, last modified: 2011-10-04
Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of Weakly Interacting Massive Particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical significance for a modulation of ~2.8 sigma, limited by the short exposure.
[18]  oai:arXiv.org:1002.4703  [pdf] - 339357
Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
Comments: 4 pages, 4 figures. v2: submitted version. Minimal changes in wording, one reference added
Submitted: 2010-02-25, last modified: 2010-03-15
We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.
[19]  oai:arXiv.org:0807.0879  [pdf] - 14236
Experimental constraints on a dark matter origin for the DAMA annual modulation effect
Comments: v4: introduces recent results from arXiv:0807.3279 and arXiv:0807.2926. Sensitivity to pseudoscalars is revised in light of the first. Discussion on the subject added
Submitted: 2008-07-05, last modified: 2008-07-31
A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars mightlead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular to Next-to-Minimal Supersymmetric Model candidates.