Normalized to: Orrell, J.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:1806.07043 [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in
Germanium with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwal, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Banik, S.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium
detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds
from radioactive isotopes activated by cosmogenic radiation inside the
germanium. There are limited experimental data available to constrain
production rates and a large spread of theoretical predictions. We examine the
calculation of expected production rates, and analyze data from the second run
of the CDMS low ionization threshold experiment (CDMSlite) to estimate the
rates for several isotopes. We model the measured CDMSlite spectrum and fit for
contributions from tritium and other isotopes. Using the knowledge of the
detector history, these results are converted to cosmogenic production rates at
sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H,
1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]
oai:arXiv.org:1903.03663 [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.;
Giampa, P.;
Retiere, F.;
Kroeger, J.;
Zhang, G.;
Ward, M.;
Margetak, P.;
Lic, G.;
Tsang, T.;
Doria, L.;
Kharusi, S. Al;
Alfaris, M.;
Anton, G.;
Arnquist, I. J.;
Badhrees, I.;
Barbeau, P. S.;
Beck, D.;
Belov, V.;
Bhatta, T.;
Blatchford, J.;
Brodsky, J. P.;
Brown, E.;
Brunner, T.;
Cao, G. F.;
Cao, L.;
Cen, W. R.;
Chambers, C.;
Charlebois, S. A.;
Chiu, M.;
Cleveland, B.;
Coon, M.;
Craycraft, A.;
Dalmasson, J.;
Daniels, T.;
Darroch, L.;
Daugherty, S. J.;
Croix, A. De St.;
Der Mesrobian-Kabakian, A.;
DeVoe, R.;
Dilling, J.;
Ding, Y. Y.;
Dolinski, M. J.;
Dragone, A.;
Echevers, J.;
Elbeltagi, M.;
Fabris, L.;
Fairbank, D.;
Fairbank, W.;
Farine, J.;
Feyzbakhsh, S.;
Fontaine, R.;
Gautam, P.;
Giacomini, G.;
Gornea, R.;
Gratta, G.;
Hansen, E. V.;
Heffner, M.;
Hoppe, E. W.;
Hoßl, J.;
House, A.;
Hughes, M.;
Ito, Y.;
Iverson, A.;
Jamil, A.;
Jewell, M. J.;
Jiang, X. S.;
Karelin, A.;
Kaufman, L. J.;
Kodroff, D.;
Koffas, T.;
Krucken, R.;
Kuchenkov, A.;
Kumar, K. S.;
Lana, Y.;
Larson, A.;
Lenardo, B. G.;
Leonarda, D. S.;
Lik, S.;
Li, Z.;
Licciardi, C.;
Linw, Y. H.;
Lv, P.;
MacLellan, R.;
McElroy, T.;
Medina-Peregrina, M.;
Michel, T.;
Mong, B.;
Moore, D. C.;
Murray, K.;
Nakarmi, P.;
Newby, R. J.;
Ning, Z.;
Njoya, O.;
Nolet, F.;
Nusair, O.;
Odgers, K.;
Odian, A.;
Oriunno, M.;
Orrell, J. L.;
Ortega, G. S.;
Ostrovskiy, I.;
Overman, C. T.;
Parent, S.;
Piepkez, A.;
Pocar, A.;
Pratte, J. -F.;
Qiu, D.;
Radeka, V.;
Raguzin, E.;
Rescia, S.;
Richman, M.;
Robinson, A.;
Rossignol, T.;
Rowson, P. C.;
Roy, N.;
Saldanha, R.;
Sangiorgio, S.;
VIII, K. Skarpaas;
Soma, A. K.;
St-Hilaire, G.;
Stekhanov, V.;
Stiegler, T.;
Sun, X. L.;
Tarka, M.;
Todd, J.;
Tolba, T.;
Totev, T. I.;
Tsang, R.;
Vachon, F.;
Veeraraghavan, V.;
Visser, G.;
Vuilleumier, J. -L.;
Wagenpfeil, M.;
Walent, M.;
Wang, Q.;
Watkins, J.;
Weber, M.;
Wei, W.;
Wen, L. J.;
Wichoski, U.;
Wu, S. X.;
Wu, W. H.;
Wu, X.;
Xia, Q.;
Yang, H.;
Yang, L.;
Yen, Y. -R.;
Zeldovich, O.;
Zhao, J.;
Zhou, Y.;
Ziegler, T.
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N:
S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers
(SiPMs) as part of the development of a solution for the detection of liquid
xenon scintillation light for the nEXO experiment. Various SiPM features, such
as: dark noise, gain, correlated avalanches, direct crosstalk and Photon
Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs
were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233
\text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163
\text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse
in the $1 \upmu\text{s}$ interval following the trigger pulse of
$0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is
$0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are
within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two
different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of
$189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we
report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a
saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both
values are well below the $24\text{ }\%$ saturation PDE advertised by
Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over
voltage is below the nEXO PDE requirement. The first one instead yields a PDE
that is marginally close to meeting the nEXO specifications. This suggests that
with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an
alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[4]
oai:arXiv.org:1804.10697 [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive
Detector
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Di Stefano, P. C. F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Leyva, J. V.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Romani, R. K.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
So, J.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
[5]
oai:arXiv.org:1808.09098 [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood
Fit
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
De Brienne, F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Neog, H.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment
(CDMSlite) searches for interactions between dark matter particles and
germanium nuclei in cryogenic detectors. The experiment has achieved a low
energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark
matter particles. We present an analysis of the final CDMSlite data set, taken
with a different detector than was used for the two previous CDMSlite data
sets. This analysis includes a data "salting" method to protect against bias,
improved noise discrimination, background modeling, and the use of profile
likelihood methods to search for a dark matter signal in the presence of
backgrounds. We achieve an energy threshold of 70 eV and significantly improve
the sensitivity for dark matter particles with masses between 2.5 and 10
GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark
matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$
cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous
CDMSlite result.
[6]
oai:arXiv.org:1805.09942 [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS
Germanium Detectors
Agnese, Robert;
Aralis, Taylor;
Aramaki, Tsuguo;
Arnquist, Isaac;
Azadbakht, Elham;
Baker, William;
Banik, Samir;
Barker, D'Ann;
Bauer, Dan;
Binder, Thomas;
Bowles, Michael;
Brink, Paul;
Bunker, Ray;
Cabrera, Blas;
Calkins, Robert;
Cartaro, Concetta;
Cerdeno, David;
Chang, Yen-Yung;
Cooley, Jodi;
Cornell, Brett;
Cushman, Priscilla;
Di Stefano, Philippe;
Doughty, Todd;
Fascione, Eleanor;
Figueroa, Tali;
Fink, Caleb;
Fritts, Matt;
Gerbier, Gilles;
Germond, Richard;
Ghaith, Muad;
Golwala, Sunil;
Harris, Rusty;
Hong, Ziqing;
Hoppe, Eric;
Hsu, Lauren;
Huber, Martin;
Iyer, Vijay;
Jardin, Dan;
Jena, Chitrasen;
Kelsey, Michael;
Kennedy, Allison;
Kubik, Andrew;
Kurinsky, Noah;
Lawrence, Richard;
Loer, Ben;
Lopez-Asamar, Elias;
Lukens, Pat;
MacDonell, Danika;
Mahapatra, Rupak;
Mandic, Vuk;
Mast, Nicholas;
Miller, Eric;
Mirabolfathi, Nader;
Mohanty, Bedangadas;
Morales, Jorge;
Nelson, Jack;
Orrell, John;
Oser, Scott;
Page, William;
Partridge, Richard;
Pepin, Mark;
Ponce, Francisco;
Poudel, Sudip;
Pyle, Matt;
Qiu, Hang;
Rau, Wolfgang;
Reisetter, Angela;
Ren, Tom;
Reynolds, Tyler;
Roberts, Amy;
Robinson, Alan;
Rogers, Hannah;
Saab, Tarek;
Sadoulet, Bernard;
Sander, Joel;
Scarff, Andrew;
Schnee, Richard;
Scorza, Silvia;
Senapati, Kartik;
Serfass, Bruno;
Speller, Danielle;
Stein, Matthew;
Street, Joseph;
Tanaka, Hirohisa;
Toback, David;
Underwood, Ryan;
Villano, Anthony;
von Krosigk, Belina;
Watkins, Samuel;
Wilson, Jon;
Wilson, Matthew;
Winchell, Joshua;
Wright, Dennis;
Yellin, Steve;
Young, Betty;
Zhang, Xiaohe;
Zhao, Xuji
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan
Underground Laboratory studied energy loss associated with Frenkel defect
formation in germanium crystals at mK temperatures using in situ $^{210}$Pb
sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its
expected 103 keV endpoint energy and determine an energy loss of
$\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this
result and using TRIM simulations, we extract the first experimentally
determined average displacement threshold energy of
$\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for
the analysis thresholds of future germanium-based dark matter searches.
[7]
oai:arXiv.org:1707.01632 [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Martinez, M. Penalver;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
[9]
oai:arXiv.org:1610.00006 [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Arnquist, I.;
Baker, W.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hong, Z.;
Hoppe, E.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly
detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter
by using cryogenic detectors of two types (HV and iZIP) and two target
materials (germanium and silicon). The experiment is being designed with an
initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$
for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue
exploration to both smaller masses and better sensitivities. The phonon
sensitivity of the HV detectors will be sufficient to detect nuclear recoils
from sub-GeV dark matter. A detailed calibration of the detector response to
low energy recoils will be needed to optimize running conditions of the HV
detectors and to interpret their data for dark matter searches. Low-activity
shielding, and the depth of SNOLAB, will reduce most backgrounds, but
cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be
present in the detectors at some level. Even if these backgrounds are x10
higher than expected, the science reach of the HV detectors would be over three
orders of magnitude beyond current results for a dark matter mass of 1
GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in
detector response and backgrounds, and will provide better sensitivity for dark
matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and
iZIP), and targets (germanium and silicon), planned for the experiment, as well
as flexibility in how the detectors are operated, will allow us to maximize the
low-mass reach, and understand the backgrounds that the experiment will
encounter. Upgrades to the experiment, perhaps with a variety of
ultra-low-background cryogenic detectors, will extend dark matter sensitivity
down to the "neutrino floor", where coherent scatters of solar neutrinos become
a limiting background.
[10]
oai:arXiv.org:1401.6234 [pdf] - 931856
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of
CoGeNT Data
Aalseth, C. E.;
Barbeau, P. S.;
Leon, J. Diaz;
Fast, J. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.
Submitted: 2014-01-23, last modified: 2015-02-05
CoGeNT has taken data for over 3 years, with 1136 live days of data
accumulated as of April 23, 2013. We report on the results of a maximum
likelihood analysis to extract any possible dark matter signal present in the
collected data. The maximum likelihood signal extraction uses 2-dimensional
probability density functions (PDFs) to characterize the anticipated variations
in dark matter interaction rates for given observable nuclear recoil energies
during differing periods of the Earth's annual orbit around the Sun. Cosmogenic
and primordial radioactivity backgrounds are characterized by their energy
signatures and in some cases decay half-lives. A third parameterizing variable
-- pulse rise-time -- is added to the likelihood analysis to characterize slow
rising pulses described in prior analyses. The contribution to each event
category is analyzed for various dark matter signal hypotheses including a dark
matter standard halo model and a case with free oscillation parameters (i.e.,
amplitude, period, and phase). The best-fit dark matter signal is in close
proximity to previously reported results. We find that the significance of the
extracted dark matter signal remains well below evidentiary at 1.7 $\sigma$.
[11]
oai:arXiv.org:1407.7524 [pdf] - 903589
Coherent neutrino-nucleus scattering detection with a CsI[Na]
scintillator at the SNS spallation source
Submitted: 2014-07-28, last modified: 2014-08-20
We study the possibility of using CsI[Na] scintillators as an advantageous
target for the detection of coherent elastic neutrino-nucleus scattering
(CENNS), using the neutrino emissions from the SNS spallation source at Oak
Ridge National Laboratory. The response of this material to low-energy nuclear
recoils like those expected from this process is characterized. Backgrounds are
studied using a 2 kg low-background prototype crystal in a dedicated radiation
shield. The conclusion is that a planned 14 kg detector should measure
approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr
low-energy threshold, with a signal-to-background ratio sufficient for a first
measurement of the CENNS cross-section. The cross-section for the
$^{208}$Pb($\nu_{e},e^{-}$)$^{208}$Bi reaction, of interest for future
supernova neutrino detection, can be simultaneously obtained.
[12]
oai:arXiv.org:1403.0475 [pdf] - 797476
A search for bremsstrahlung solar axions using the Majorana
low-background BEGe detector at Kimballton (MALBEK)
Abgrall, N.;
Aguayo, E.;
Avignone, F. T.;
Barabash, A. S.;
Bertrand, F. E.;
Boswell, M.;
Brudanin, V.;
Busch, M.;
Caldwell, A. S.;
Chan, Y-D.;
Christofferson, C. D.;
Combs, D. C.;
Cooper, R. J.;
Creswick, R. J.;
Detwiler, J. A.;
Doe, P. J.;
Efremenko, Yu.;
Egorov, V.;
Elliott, S. R.;
Fast, J. E.;
Finnerty, P.;
Fraenkle, F. M.;
Galindo-Uribarri, A.;
Giovanetti, G. K.;
Goett, J.;
Green, M. P.;
Gruszko, J.;
Guiseppe, V. E.;
Gusev, K.;
Hegai, A.;
Henning, R.;
Hoppe, E. W.;
Howard, S.;
Howe, M. A.;
Keeter, K. J.;
Kidd, M. F.;
Knecht, A.;
Kochetov, O.;
Konovalov, S. I.;
Kouzes, R. T.;
LaFerriere, B. D.;
Leon, J.;
Leviner, L. E.;
Loach, J. C.;
MacMullin, J.;
MacMullin, S.;
Marino, M. G.;
Martin, R. D.;
Mertens, S.;
Orrell, J. L.;
O'Shaughnessy, C.;
Overman, N. R.;
Phillips, D. G.;
Poon, A. W. P.;
Pushkin, K.;
Radford, D. C.;
Rielage, K.;
Robertson, R. G. H.;
Ronquest, M. C.;
Schubert, A. G.;
Shanks, B.;
Shirchenko, M.;
Snavely, K. J.;
Snyder, N.;
Steele, D.;
Suriano, A. M.;
Thompson, J.;
Timkin, V.;
Varner, R. L.;
Vasilyev, S.;
Vetter, K.;
Vorren, K.;
White, B. R.;
Wilkerson, J. F.;
Xu, W.;
Yakushev, E.;
Young, A. R.;
Yu, C. H.;
Yumatov, V.
Submitted: 2014-03-03, last modified: 2014-03-17
A low-background, high-purity germanium detector has been used to search for
evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound
of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ
model axions to electrons. The prospects for the sensitivity of the Majorana
Demonstrator array of point-contact germanium detectors to solar axions are
discussed in the context of the model-independent annual modulation due to the
seasonal variation of the earth-sun distance.
[13]
oai:arXiv.org:1401.3295 [pdf] - 770398
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter
Detector Data
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2014-01-14
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter
candidates. WIMP interactions with sensitive detectors are expected to display
a characteristic annual modulation in rate. We release a dataset spanning 3.4
years of operation from a low-background germanium detector, designed to search
for this signature. A previously reported modulation persists, concentrated in
a region of the energy spectrum populated by an exponential excess of unknown
origin. Its phase and period agree with phenomenological expectations, but its
amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP
galactic halo. We consider the possibility of a non-Maxwellian local halo
velocity distribution as a plausible explanation, able to help reconcile
recently reported WIMP search anomalies.
[14]
oai:arXiv.org:1310.8327 [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Cushman, P.;
Galbiati, C.;
McKinsey, D. N.;
Robertson, H.;
Tait, T. M. P.;
Bauer, D.;
Borgland, A.;
Cabrera, B.;
Calaprice, F.;
Cooley, J.;
Empl, T.;
Essig, R.;
Figueroa-Feliciano, E.;
Gaitskell, R.;
Golwala, S.;
Hall, J.;
Hill, R.;
Hime, A.;
Hoppe, E.;
Hsu, L.;
Hungerford, E.;
Jacobsen, R.;
Kelsey, M.;
Lang, R. F.;
Lippincott, W. H.;
Loer, B.;
Luitz, S.;
Mandic, V.;
Mardon, J.;
Maricic, J.;
Maruyama, R.;
Mahapatra, R.;
Nelson, H.;
Orrell, J.;
Palladino, K.;
Pantic, E.;
Partridge, R.;
Ryd, A.;
Saab, T.;
Sadoulet, B.;
Schnee, R.;
Shepherd, W.;
Sonnenschein, A.;
Sorensen, P.;
Szydagis, M.;
Volansky, T.;
Witherell, M.;
Wright, D.;
Zurek, K.
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection
subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader
Particle Physics community to produce this document. The charge to CF1 was (a)
to summarize the current status and projected sensitivity of WIMP direct
detection experiments worldwide, (b) motivate WIMP dark matter searches over a
broad parameter space by examining a spectrum of WIMP models, (c) establish a
community consensus on the type of experimental program required to explore
that parameter space, and (d) identify the common infrastructure required to
practically meet those goals.
[15]
oai:arXiv.org:1208.5737 [pdf] - 690015
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact
Germanium Detectors
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2012-08-28, last modified: 2013-04-29
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for
Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy
threshold and ability to reject surface backgrounds, this type of device allows
an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2).
We report on the characteristics of the PPC detector presently taking data at
the Soudan Underground Laboratory, elaborating on aspects of shielding, data
acquisition, instrumental stability, data analysis, and background estimation.
A detailed background model is used to investigate the low energy excess of
events previously reported, and to assess the possibility of temporal
modulations in the low-energy event rate. Extensive simulations of all
presently known backgrounds do not provide a viable background explanation for
the excess of low-energy events in the CoGeNT data, or the previously observed
temporal variation in the event rate. Also reported on for the first time is a
determination of the surface (slow pulse rise time) event contamination in the
data as a function of energy. We conclude that the CoGeNT detector technology
is well suited to search for the annual modulation signature expected from dark
matter particle interactions in the region of WIMP mass and coupling favored by
the DAMA/LIBRA results
[16]
oai:arXiv.org:1210.6282 [pdf] - 1152380
The C-4 Dark Matter Experiment
Bonicalzi, R. M.;
Collar, J. I.;
Colaresi, J.;
Fast, J. E.;
Fields, N. E.;
Fuller, E. S.;
Hai, M.;
Hossbach, T. W.;
Kos, M. S.;
Orrell, J. L.;
Overman, C. T.;
Reid, D. J.;
VanDevender, B. A.;
Wiseman, C.;
Yocum, K. M.
Submitted: 2012-10-23, last modified: 2013-02-07
We describe the experimental design of C-4, an expansion of the CoGeNT dark
matter search to four identical detectors each approximately three times the
mass of the p-type point contact germanium diode presently taking data at the
Soudan Underground Laboratory. Expected reductions of radioactive backgrounds
and energy threshold are discussed, including an estimate of the additional
sensitivity to low-mass dark matter candidates to be obtained with this search.
[17]
oai:arXiv.org:1106.0650 [pdf] - 669552
Search for an Annual Modulation in a P-type Point Contact Germanium Dark
Matter Detector
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Knecht, A.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2011-06-03, last modified: 2011-10-04
Fifteen months of cumulative CoGeNT data are examined for indications of an
annual modulation, a predicted signature of Weakly Interacting Massive Particle
(WIMP) interactions. Presently available data support the presence of a
modulated component of unknown origin, with parameters prima facie compatible
with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield
a statistical significance for a modulation of ~2.8 sigma, limited by the short
exposure.
[18]
oai:arXiv.org:1002.4703 [pdf] - 339357
Results from a Search for Light-Mass Dark Matter with a P-type Point
Contact Germanium Detector
Aalseth, C. E.;
Barbeau, P. S.;
Bowden, N. S.;
Cabrera-Palmer, B.;
Colaresi, J.;
Collar, J. I.;
Dazeley, S.;
de Lurgio, P.;
Drake, G.;
Fast, J. E.;
Fields, N.;
Greenberg, C. H.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Reyna, D.;
Robertson, R. G. H.;
Talaga, R. L.;
Tench, O.;
Van Wechel, T. D.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2010-02-25, last modified: 2010-03-15
We report on several features present in the energy spectrum from an ultra
low-noise germanium detector operated at 2,100 m.w.e. By implementing a new
technique able to reject surface events, a number of cosmogenic peaks can be
observed for the first time. We discuss several possible causes for an
irreducible excess of bulk-like events below 3 keVee, including a dark matter
candidate common to the DAMA/LIBRA annual modulation effect, the hint of a
signal in CDMS, and phenomenological predictions. Improved constraints are
placed on a cosmological origin for the DAMA/LIBRA effect.
[19]
oai:arXiv.org:0807.0879 [pdf] - 14236
Experimental constraints on a dark matter origin for the DAMA annual
modulation effect
Aalseth, C. E.;
Barbeau, P. S.;
Cerdeno, D. G.;
Colaresi, J.;
Collar, J. I.;
de Lurgio, P.;
Drake, G.;
Fast, J. E.;
Greenberg, C. H.;
Hossbach, T. W.;
Kephart, J. D.;
Marino, M. G.;
Miley, H. S.;
Orrell, J. L.;
Reyna, D.;
Robertson, R. G. H.;
Talaga, R.;
Tench, O.;
Van Wechel, T. D.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2008-07-05, last modified: 2008-07-31
A claim for evidence of dark matter interactions in the DAMA experiment has
been recently reinforced. We employ a new type of germanium detector to
conclusively rule out a standard isothermal galactic halo of Weakly Interacting
Massive Particles (WIMPs) as the explanation for the annual modulation effect
leading to the claim. Bounds are similarly imposed on a suggestion that dark
pseudoscalars mightlead to the effect. We describe the sensitivity to light
dark matter particles achievable with our device, in particular to
Next-to-Minimal Supersymmetric Model candidates.