oai:arXiv.org:1509.00129 [pdf] - 1530302
First Light Results from the Hermes Spectrograph at the AAT
Sheinis, Andrew;
Anguiano, Borja;
Asplund, Martin;
Bacigalupo, Carlos;
Barden, Sam;
Birchall, Michael;
Bland-Hawthorn, Joss;
Brzeski, Jurek;
Cannon, Russell;
Carollo, Daniela;
Case, Scott;
Casey, Andrew;
Churilov, Vladimir;
Warrick, Couch;
Dean, Robert;
De Silva, Gayandhi;
D'Orazi, Valentina;
Duong, Ly;
Farrell, Tony;
Fiegert, Kristin;
Freeman, Kenneth;
Gabriella, Frost;
Gers, Luke;
Goodwin, Michael;
Gray, Doug;
Green, Andrew;
Heald, Ron;
Heijmans, Jeroen;
Ireland, Michael;
Jones, Damien;
Kafle, Prajwal;
Keller, Stefan;
Klauser, Urs;
Kondrat, Yuriy;
Kos, Janez;
Lawrence, Jon;
Lee, Steve;
Mali, Slavko;
Martell, Sarah;
Mathews, Darren;
Mayfield, Don;
Miziarski, Stan;
Muller, Rolf;
Pai, Naveen;
Patterson, Robert;
Penny, Ed;
Orr, David;
Schlesinger, Katharine;
Sharma, Sanjib;
Shortridge, Keith;
Simpson, Jeffrey;
Smedley, Scott;
Smith, Greg;
Stafford, Darren;
Staszak, Nicholas;
Vuong, Minh;
Waller, Lewis;
de Boer, Elizabeth Wylie;
Xavier, Pascal;
Zheng, Jessica;
Zhelem, Ross;
Zucker, Daniel;
Zwitter, Tomaz
Submitted: 2015-08-31
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a
facility-class optical spectrograph for the Anglo-Australian Telescope (AAT).
It is designed primarily for Galactic Archaeology, the first major attempt to
create a detailed understanding of galaxy formation and evolution by studying
the history of our own galaxy, the Milky Way. The goal of the GALAH survey is
to reconstruct the mass assembly history of the Milky Way through a detailed
chemical abundance study of one million stars. The spectrograph is based at the
AAT and is fed by the existing 2dF robotic fiber positioning system. The
spectrograph uses volume phase holographic gratings to achieve a spectral
resolving power of 28,000 in standard mode and also provides a high-resolution
mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey
requires an SNR greater than 100 for a star brightness of V ?= 14 in an
exposure time of one hour. The total spectral coverage of the four channels is
about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within
the 2-degree field of view. HERMES has been commissioned over three runs,
during bright time in October, November, and December 2013, in parallel with
the beginning of the GALAH pilot survey, which started in November 2013. We
present the first-light results from the commissioning run and the beginning of
the GALAH survey, including performance results such as throughput and
resolution, as well as instrument reliability.
[2]
oai:arXiv.org:1301.0670 [pdf] - 610414
CYCLOPS2: the fibre image slicer upgrade for the UCLES high resolution
spectrograph
Horton, Anthony;
Tinney, C. G.;
Case, Scott;
Farrell, Tony;
Gers, Luke;
Jones, Damien;
Lawrence, Jon;
Miziarski, Stan;
Staszak, Nick;
Orr, David;
Vuong, Minh;
Waller, Lew;
Zhelem, Ross
Submitted: 2013-01-03
CYCLOPS2 is an upgrade for the UCLES high resolution spectrograph on the
Anglo-Australian Telescope, scheduled for commissioning in semester 2012A. By
replacing the 5 mirror Coud\'e train with a Cassegrain mounted fibre-based
image slicer CYCLOPS2 simultaneously provides improved throughput, reduced
aperture losses and increased spectral resolution. Sixteen optical fibres
collect light from a 5.0 arcsecond^2 area of sky and reformat it into the
equivalent of a 0.6 arcsecond wide slit, delivering a spectral resolution of R
= 70000 and up to twice as much flux as the standard 1 arcsecond slit of the
Coud\'e train. CYCLOPS2 also adds support for simultaneous ThAr wavelength
calibration via a dedicated fibre. CYCLOPS2 consists of three main components,
the fore-optics unit, fibre bundle and slit unit. The fore optics unit
incorporates magnification optics and a lenslet array and is designed to mount
to the CURE Cassegrain instrument interface, which provides acquisition,
guiding and calibration facilities. The fibre bundle transports the light from
the Cassegrain focus to the UCLES spectrograph at Coud\'e and also includes a
fibre mode scrambler. The slit unit consists of the fibre slit and relay optics
to project an image of the slit onto the entrance aperture of the UCLES
spectrograph. CYCLOPS2 builds on experience with the first generation CYCLOPS
fibre system, which we also describe in this paper. We present the science case
for an image slicing fibre feed for echelle spectroscopy and describe the
design of CYCLOPS and CYCLOPS2.