Normalized to: Orosz, N.
[1]
oai:arXiv.org:2003.08399 [pdf] - 2067038
Redundant-Baseline Calibration of the Hydrogen Epoch of Reionization
Array
Dillon, Joshua S.;
Lee, Max;
Ali, Zaki S.;
Parsons, Aaron R.;
Orosz, Naomi;
Nunhokee, Chuneeta Devi;
La Plante, Paul;
Beardsley, Adam P.;
Kern, Nicholas S.;
Abdurashidova, Zara;
Aguirre, James E.;
Alexander, Paul;
Balfour, Yanga;
Bernardi, Gianni;
Billings, Tashalee S.;
Bowman, Judd D.;
Bradley, Richard F.;
Bull, Phil;
Burba, Jacob;
Carey, Steve;
Carilli, Chris L.;
Cheng, Carina;
DeBoer, David R.;
Dexter, Matt;
Acedo, Eloy de Lera;
Ely, John;
Ewall-Wice, Aaron;
Fagnoni, Nicolas;
Fritz, Randall;
Furlanetto, Steven R.;
Gale-Sides, Kingsley;
Glendenning, Brian;
Gorthi, Deepthi;
Greig, Bradley;
Grobbelaar, Jasper;
Halday, Ziyaad;
Hazelton, Bryna J.;
Hewitt, Jacqueline N.;
Hickish, Jack;
Jacobs, Daniel C.;
Julius, Austin;
Kerrigan, Joshua;
Kittiwisit, Piyanat;
Kohn, Saul A.;
Kolopanis, Matthew;
Lanman, Adam;
Lekalake, Telalo;
Lewis, David;
Liu, Adrian;
Ma, Yin-Zhe;
MacMahon, David;
Malan, Lourence;
Malgas, Cresshim;
Maree, Matthys;
Martinot, Zachary E.;
Matsetela, Eunice;
Mesinger, Andrei;
Molewa, Mathakane;
Morales, Miguel F.;
Mosiane, Tshegofalang;
Murray, Steven;
Neben, Abraham R.;
Nikolic, Bojan;
Pascua, Robert;
Patra, Nipanjana;
Pieterse, Samantha;
Pober, Jonathan C.;
Razavi-Ghods, Nima;
Ringuette, Jon;
Robnett, James;
Rosie, Kathryn;
Santos, Mario G.;
Sims, Peter;
Smith, Craig;
Syce, Angelo;
Tegmark, Max;
Thyagarajan, Nithyanandan;
Williams, Peter K. G.;
Zheng, Haoxuan
Submitted: 2020-03-18
In 21 cm cosmology, precision calibration is key to the separation of the
neutral hydrogen signal from bright astrophysical foregrounds. If not properly
calibrated, each antenna element's complex gain can impart spectral structure
on otherwise spectrally-smooth foregrounds, complicating that statistical
separation. The Hydrogen Epoch of Reionization Array (HERA), an interferometer
specialized for 21 cm cosmology and now under construction in South Africa, was
designed to be largely calibrated using the self-consistency of repeated
measurements of the same interferometric modes. This technique, known as
redundant-baseline calibration resolves most of the internal degrees of freedom
in the calibration problem. It assumes, however, on antenna elements with
identical primary beams placed precisely on a redundant grid. In this work, we
review the detailed implementation of the algorithms enabling
redundant-baseline calibration and report results with HERA data. We quantify
the effects of real-world non-redundancy and how they compare to the idealized
scenario in which redundant measurements differ only in their noise
realizations. Finally, we study how non-redundancy can produce spurious
temporal structure in our calibration solutions---both in data and in
simulations---and present strategies for mitigating that structure.
[2]
oai:arXiv.org:1809.09728 [pdf] - 1892182
Mitigating the Effects of Antenna-to-Antenna Variation on
Redundant-Baseline Calibration for 21 cm Cosmology
Submitted: 2018-09-25, last modified: 2019-05-29
The separation of cosmological signal from astrophysical foregrounds is a
fundamental challenge for any effort to probe the evolution of neutral hydrogen
during the Cosmic Dawn and epoch of reionization (EoR) using the 21 cm
hyperfine transition. Foreground separation is made possible by their intrinsic
spectral smoothness, making them distinguishable from spectrally complex
cosmological signal even though they are ~5 orders of magnitude brighter.
Precisely calibrated radio interferometers are essential to maintaining the
smoothness and thus separability of the foregrounds. One powerful calibration
strategy is to use redundant measurements between pairs of antennas with the
same physical separation in order to solve for each antenna's spectral response
without reference to a sky model. This strategy is being employed by the
Hydrogen Epoch of Reionization Array (HERA), a large radio telescope in South
Africa that is now observing while being built out to 350 14-m dishes. However,
the deviations from perfect redundancy inherent in any real radio telescope
complicate the calibration problem. Using simulations of HERA, we show how
calibration with antenna-to-antenna variations in dish construction and
placement generally lead to spectral structure in otherwise smooth foregrounds
that significantly reduces the number of cosmological modes available to a 21
cm measurement. However, we also show that this effect can be largely
eliminated by a modified redundant-baseline calibration strategy that relies
predominantly on short baselines.