sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Orndorff, Joe

Normalized to: Orndorff, J.

7 article(s) in total. 165 co-authors, from 1 to 7 common article(s). Median position in authors list is 41,0.

[1]  oai:arXiv.org:1608.01075  [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives
Tamura, Naoyuki; Takato, Naruhisa; Shimono, Atsushi; Moritani, Yuki; Yabe, Kiyoto; Ishizuka, Yuki; Ueda, Akitoshi; Kamata, Yukiko; Aghazarian, Hrand; Arnouts, Stephane; Barban, Gabriel; Barkhouser, Robert H.; Borges, Renato C.; Braun, David F.; Carr, Michael A.; Chabaud, Pierre-Yves; Chang, Yin-Chang; Chen, Hsin-Yo; Chiba, Masashi; Chou, Richard C. Y.; Chu, You-Hua; Cohen, Judith G.; de Almeida, Rodrigo P.; de Oliveira, Antonio C.; de Oliveira, Ligia S.; Dekany, Richard G.; Dohlen, Kjetil; Santos, Jesulino B. dos; Santos, Leandro H. dos; Ellis, Richard S.; Fabricius, Maximilian; Ferrand, Didier; Ferreira, Decio; Golebiowski, Mirek; Greene, Jenny E.; Gross, Johannes; Gunn, James E.; Hammond, Randolph; Harding, Albert; Hart, Murdock; Heckman, Timothy M.; Hirata, Christopher M.; Ho, Paul; Hope, Stephen C.; Hovland, Larry; Hsu, Shu-Fu; Hu, Yen-Shan; Huang, Ping-Jie; Jaquet, Marc; Jing, Yipeng; Karr, Jennifer; Kimura, Masahiko; King, Matthew E.; Komatsu, Eiichiro; Brun, Vincent Le; Fevre, Olivier Le; Fur, Arnaud Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig P.; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas S.; de Oliveira, Claudia Mendes; Minowa, Yosuke; Morantz, Chaz N.; Murayama, Hitoshi; Murray, Graham J.; Ohyama, Youichi; Orndorff, Joseph; Pascal, Sandrine; Pereira, Jefferson M.; Reiley, Daniel J.; Reinecke, Martin; Ritter, Andreas; Roberts, Mitsuko; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Sodre, Laerte; Spergel, David N.; Steinkraus, Aaron J.; Strauss, Michael A.; Surace, Christian; Suto, Yasushi; Suzuki, Nao; Swinbank, John; Tait, Philip J.; Takada, Masahiro; Tamura, Tomonori; Tanaka, Yoko; Tresse, Laurence; Verducci, Orlando; Vibert, Didier; Vidal, Clement; Wang, Shiang-Yu; Wen, Chih-Yi; Yan, Chi-Hung; Yasuda, Naoki
Comments: 17 pages, 10 figures. Proceeding of SPIE Astronomical Telescopes and Instrumentation 2016
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.
[2]  oai:arXiv.org:1507.00725  [pdf] - 1241387
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime; Tamura, Naoyuki; Karoji, Hiroshi; Shimono, Atsushi; Takato, Naruhisa; Kimura, Masahiko; Ohyama, Youichi; Ueda, Akitoshi; Aghazarian, Hrand; de Arruda, Marcio Vital; Barkhouser, Robert H.; Bennett, Charles L.; Bickerton, Steve; Bozier, Alexandre; Braun, David F.; Bui, Khanh; Capocasale, Christopher M.; Carr, Michael A.; Castilho, Bruno; Chang, Yin-Chang; Chen, Hsin-Yo; Chou, Richard C. Y.; Dawson, Olivia R.; Dekany, Richard G.; Ek, Eric M.; Ellis, Richard S.; English, Robin J.; Ferrand, Didier; Ferreira, Décio; Fisher, Charles D.; Golebiowski, Mirek; Gunn, James E.; Hart, Murdock; Heckman, Timothy M.; Ho, Paul T. P.; Hope, Stephen; Hovland, Larry E.; Hsu, Shu-Fu; Hu, Yen-Shan; Huang, Pin Jie; Jaquet, Marc; Karr, Jennifer E.; Kempenaar, Jason G.; King, Matthew E.; Fèvre, Olivier Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas Souza; Ménard, Brice; Morantz, Chaz; Murayama, Hitoshi; Murray, Graham J.; de Oliveira, Antonio Cesar; de Oliveira, Claudia Mendes; de Oliveira, Ligia Souza; Orndorff, Joe D.; Vilaça, Rodrigo de Paiva; Partos, Eamon J.; Pascal, Sandrine; Pegot-Ogier, Thomas; Reiley, Daniel J.; Riddle, Reed; Santos, Leandro; Santos, Jesulino Bispo dos; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Smith, Roger M.; Steinkraus, Ronald E.; Sodré, Laerte; Spergel, David N.; Surace, Christian; Tresse, Laurence; Vidal, Clément; Vives, Sebastien; Wang, Shiang-Yu; Wen, Chih-Yi; Wu, Amy C.; Wyse, Rosie; Yan, Chi-Hung
Comments: 19 pages, 11 figures
Submitted: 2015-07-02
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.
[3]  oai:arXiv.org:1408.2825  [pdf] - 1216260
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime; Tamura, Naoyuki; Karoji, Hiroshi; Shimono, Atsushi; Takato, Naruhisa; Kimura, Masahiko; Ohyama, Youichi; Ueda, Akitoshi; Aghazarian, Hrand; de Arruda, Marcio Vital; Barkhouser, Robert H.; Bennett, Charles L.; Bickerton, Steve; Bozier, Alexandre; Braun, David F.; Bui, Khanh; Capocasale, Christopher M.; Carr, Michael A.; Castilho, Bruno; Chang, Yin-Chang; Chen, Hsin-Yo; Chou, Richard C. Y.; Dawson, Olivia R.; Dekany, Richard G.; Ek, Eric M.; Ellis, Richard S.; English, Robin J.; Ferrand, Didier; Ferreira, Décio; Fisher, Charles D.; Golebiowski, Mirek; Gunn, James E.; Hart, Murdock; Heckman, Timothy M.; Ho, Paul T. P.; Hope, Stephen; Hovland, Larry E.; Hsuc, Shu-Fu; Hu, Yen-Shan; Huang, Pin Jie; Jaquet, Marc; Karr, Jennifer E.; Kempenaar, Jason G.; King, Matthew E.; Fèvre, Olivier Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas Souza; Ménard, Brice; Morantz, Chaz; Murayama, Hitoshi; Murray, Graham J.; de Oliveira, Antonio Cesar; de Oliveira, Claudia Mendes; de Oliveira, Ligia Souza; Orndorff, Joe D.; Vilaça, Rodrigo de Paiva; Partos, Eamon J.; Pascal, Sandrine; Pegot-Ogier, Thomas; Reiley, Daniel J.; Riddle, Reed; Santos, Leandro; Santos, Jesulino Bispo dos; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Smith, Roger M.; Steinkraus, Ronald E.; Sodré, Laerte; Spergel, David N.; Surace, Christian; Tresse, Laurence; Vidal, Clément; Vives, Sebastien; Wang, Shiang-Yu; Wen, Chih-Yi; Wu, Amy C.; Wyse, Rosie; Yan, Chi-Hung
Comments: 14 pages, 12 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy V, Suzanne K. Ramsay, Ian S. McLean, Hideki Takami, Editors, Proc. SPIE 9147 (2014)"
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.
[4]  oai:arXiv.org:1210.2719  [pdf] - 574579
Prime Focus Spectrograph - Subaru's future -
Comments: 13 pages, 11 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy IV, Ian S. McLean, Suzanne K. Ramsay, Hideki Takami, Editors, Proc. SPIE 8446 (2012)"
Submitted: 2012-10-09
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 {\mu}m to 1.3 {\mu}m will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.
[5]  oai:arXiv.org:1210.2740  [pdf] - 1151992
Detectors and cryostat design for the SuMIRe Prime Focus Spectrograph (PFS)
Comments:
Submitted: 2012-10-09
We describe the conceptual design of the camera cryostats, detectors, and detector readout electronics for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the Subaru telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering wavelength ranges 3800 {\AA} - 6700 {\AA}, 6500 {\AA} - 10000 {\AA}, and 9700 {\AA} - 13000 {\AA}, with the dispersed light being imaged in each channel by a f/1.10 vacuum Schmidt camera. In the blue and red channels a pair of Hamamatsu 2K x 4K edge-buttable CCDs with 15 um pixels are used to form a 4K x 4K array. For the IR channel, the new Teledyne 4K x 4K, 15 um pixel, mercury-cadmium-telluride sensor with substrate removed for short-wavelength response and a 1.7 um cutoff will be used. Identical detector geometry and a nearly identical optical design allow for a common cryostat design with the only notable difference being the need for a cold radiation shield in the IR camera to mitigate thermal background. This paper describes the details of the cryostat design and cooling scheme, relevant thermal considerations and analysis, and discusses the detectors and detector readout electronics.
[6]  oai:arXiv.org:1001.3925  [pdf] - 33032
ACCESS: Enabling an Improved Flux Scale for Astrophysics
Comments: 14 pages, 13 figures
Submitted: 2010-01-22
Improvements in the precision of the astrophysical flux scale are needed to answer fundamental scientific questions ranging from cosmology to stellar physics. The unexpected discovery that the expansion of the universe is accelerating was based upon the measurement of astrophysical standard candles that appeared fainter than expected. To characterize the underlying physical mechanism of the "Dark Energy" responsible for this phenomenon requires an improvement in the visible-NIR flux calibration of astrophysical sources to 1% precision. These improvements will also enable large surveys of white dwarf stars, e.g. GAIA, to advance stellar astrophysics by testing and providing constraints for the mass-radius relationship of these stars. ACCESS (Absolute Color Calibration Experiment for Standard Stars) is a rocket-borne payload that will enable the transfer of absolute laboratory detector standards from NIST to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of R = 500 across the 0.35-1.7 micron bandpass. Among the strategies being employed to minimize calibration uncertainties are: (1) judicious selection of standard stars (previous calibration heritage, minimal spectral features, robust stellar atmosphere models), (2) execution of observations above the Earth's atmosphere (eliminates atmospheric contamination of the stellar spectrum), (3) a single optical path and detector (to minimize visible to NIR cross-calibration uncertainties), (4) establishment of an a priori error budget, (5) on-board monitoring of instrument performance, and (6) fitting stellar atmosphere models to the data to search for discrepancies and confirm performance.
[7]  oai:arXiv.org:0807.3777  [pdf] - 14805
The FourStar Infrared Camera
Comments: 10 pages, 10 figures. To appear in to appear in "Ground-based and Airborne Instrumentation for Astronomy II" SPIE conference Proc. 7014, Marseille, 23-28 June 2008
Submitted: 2008-07-23
The FourStar infrared camera is a 1.0-2.5 micron (JHKs) near infrared camera for the Magellan Baade 6.5m telescope at Las Campanas Observatory (Chile). It is being built by Carnegie Observatories and the Instrument Development Group at Johns Hopkins and is scheduled for completion in 2009. The instrument uses four Teledyne HAWAII-2RG arrays that produce a 10.9 x 10.9 arcmin field of view. The outstanding seeing at the Las Campanas site coupled with FourStar's high sensitivity and large field of view will enable many new survey and targeted science programs.