sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Orlandi, A.

Normalized to: Orlandi, A.

4 article(s) in total. 34 co-authors, from 1 to 2 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:1509.03478  [pdf] - 1275564
Angular resolution measurements at SPring-8 of a hard X-ray optic for the New Hard X-ray Mission
Comments:
Submitted: 2015-09-11
The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg) grazing angles to enhance the reflectivity of reflective coatings. On the other hand, to obtain large collecting area, large mirror diameters (< 350 mm) are necessary. This implies that mirrors with focal lengths >10 m shall be produced and tested. Full-illumination tests of such mirrors are usually performed with on- ground X-ray facilities, aimed at measuring their effective area and the angular resolution; however, they in general suffer from effects of the finite distance of the X-ray source, e.g. a loss of effective area for double reflection. These effects increase with the focal length of the mirror under test; hence a "partial" full-illumination measurement might not be fully representative of the in-flight performances. Indeed, a pencil beam test can be adopted to overcome this shortcoming, because a sector at a time is exposed to the X-ray flux, and the compensation of the beam divergence is achieved by tilting the optic. In this work we present the result of a hard X-ray test campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation facility, aimed at characterizing the Point Spread Function (PSF) of a multilayer-coated Wolter-I mirror shell manufactured by Nickel electroforming. The mirror shell is a demonstrator for the NHXM hard X-ray imaging telescope (0.3 - 80 keV), with a predicted HEW (Half Energy Width) close to 20 arcsec. We show some reconstructed PSFs at monochromatic X-ray energies of 15 to 63 keV, and compare them with the PSFs computed from post-campaign metrology data, self-consistently treating profile and roughness data by means of a method based on the Fresnel diffraction theory. The modeling matches the measured PSFs accurately.
[2]  oai:arXiv.org:1502.04703  [pdf] - 1276979
Consistent Cosmic Microwave Background Spectra from Quantum Depletion
Comments: 23 pages, 9 figures; revised version to match published version
Submitted: 2015-02-16, last modified: 2015-08-21
Following a new quantum cosmological model proposed by Dvali and Gomez, we quantitatively investigate possible modifications to the Hubble parameter and following corrections to the cosmic microwave background spectrum. In this model, scalar and tensor perturbations are generated by the quantum depletion of the background inflaton and graviton condensate respectively. We show how the inflaton mass affects the power spectra and the tensor-to-scalar ratio. Masses approaching the Planck scale would lead to strong deviations, while standard spectra are recovered for an inflaton mass much smaller than the Planck mass.
[3]  oai:arXiv.org:1104.3043  [pdf] - 1053408
Brane-world black holes and the scale of gravity
Comments: 4 pages, no figure
Submitted: 2011-04-15
A particle in four dimensions should behave like a classical black hole if the horizon radius is larger than the Compton wavelength or, equivalently, if its degeneracy (measured by entropy in units of the Planck scale) is large. For spherically symmetric black holes in 4 + d dimensions, both arguments again lead to a mass threshold MC and degeneracy scale Mdeg of the order of the fundamental scale of gravity MG. In the brane-world, deviations from the Schwarzschild metric induced by bulk effects alter the horizon radius and effective four-dimensional Euclidean action in such a way that MC \simeq Mdeg might be either larger or smaller than MG. This opens up the possibility that black holes exist with a mass smaller than MG and might be produced at the LHC even if M>10 TeV, whereas effects due to bulk graviton exchanges remain undetectable because suppressed by inverse powers of MG. Conversely, even if black holes are not found at the LHC, it is still possible that MC>MG and MG \simeq 1TeV.
[4]  oai:arXiv.org:0903.2483  [pdf] - 22372
Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study
Comments: 6 pages, 3 figures, invited talk at the conference "2nd International Simbol-X Symposium", Paris, 2-5 december, 2008
Submitted: 2009-03-13
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission; ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV; iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.