Normalized to: Orio, F.
[1]
oai:arXiv.org:1209.2519 [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter
perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.;
Ardito, R.;
Artusa, D. R.;
Avignone, F. T.;
Azzolini, O.;
Balata, M.;
Banks, T. I.;
Bari, G.;
Beeman, J.;
Bellini, F.;
Bersani, A.;
Biassoni, M.;
Bloxham, T.;
Brofferio, C.;
Bucci, C.;
Cai, X. Z.;
Canonica, L.;
Capelli, S.;
Carbone, L.;
Cardani, L.;
Carrettoni, M.;
Casali, N.;
Chott, N.;
Clemenza, M.;
Cosmelli, C.;
Cremonesi, O.;
Creswick, R. J.;
Dafinei, I.;
Dally, A.;
Datskov, V.;
De Biasi, A.;
Decowski, M. P.;
Deninno, M. M.;
Di Domizio, S.;
di Vacri, M. L.;
Ejzak, L.;
Faccini, R.;
Fang, D. Q.;
Farach, H. A.;
Ferri, E.;
Ferroni, F.;
Fiorini, E.;
Franceschi, M. A.;
Freedman, S. J.;
Frossati, G.;
Fujikawa, B. K.;
Giachero, A.;
Gironi, L.;
Giuliani, A.;
Goett, J. J.;
Gorla, P.;
Gotti, C.;
Guardincerri, E.;
Gutierrez, T. D.;
Haller, E. E.;
Han, K.;
Heeger, K. M.;
Huang, H. Z.;
Kadel, R.;
Kazkaz, K.;
Keppel, G.;
Kogler, L.;
Kolomensky, Yu. G.;
Lenz, D.;
Li, Y. L.;
Ligi, C.;
Liu, X.;
Ma, Y. G.;
Maiano, C.;
Maino, M.;
Martinez, M.;
Maruyama, R. H.;
Moggi, N.;
Morganti, S.;
Napolitano, T.;
Newman, S.;
Nisi, S.;
Nones, C.;
Norman, E. B.;
Nucciotti, A.;
Orio, F.;
Orlandi, D.;
Ouellet, J. L.;
Pallavicini, M.;
Palmieri, V.;
Pattavina, L.;
Pavan, M.;
Pedretti, M.;
Pessina, G.;
Pirro, S.;
Previtali, E.;
Rampazzo, V.;
Rimondi, F.;
Rosenfeld, C.;
Rusconi, C.;
Sangiorgio, S.;
Scielzo, N. D.;
Sisti, M.;
Smith, A. R.;
Stivanello, F.;
Taffarello, L.;
Tenconi, M.;
Tian, W. D.;
Tomei, C.;
Trentalange, S.;
Ventura, G.;
Vignati, M.;
Wang, B. S.;
Wang, H. W.;
Whitten, C. A.;
Wise, y T.;
Woodcraft, A.;
Zanotti, L.;
Zarra, C.;
Zhu, B. X.;
Zucchelli, S.
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.
[2]
oai:arXiv.org:1012.1263 [pdf] - 955710
Lowering the energy threshold of large-mass bolometric detectors
Submitted: 2010-12-06
Large-mass bolometers are used in particle physics experiments to search for
rare processes. The energy threshold of such detectors plays a critical role in
their capability to search for dark matter interactions and rare nuclear
decays. We have developed a trigger and a pulse shape algorithm based on the
matched filter technique which, when applied to data from test bolometers of
the CUORE experiment, lowered the energy threshold from tens of keV to the few
keV region. The detection efficiency is in excess of 80%, and nearly all
nonphysical pulses are rejected.