Normalized to: Onishi, M.
[1]
oai:arXiv.org:1509.00588 [pdf] - 1270723
The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray
Detector (SGD)
Watanabe, Shin;
Tajima, Hiroyasu;
Fukazawa, Yasushi;
Ichinohe, Yuto;
Takeda, Shin'ichiro;
Enoto, Teruaki;
Fukuyama, Taro;
Furui, Shunya;
Genba, Kei;
Hagino, Kouichi;
Harayama, Astushi;
Kuroda, Yoshikatsu;
Matsuura, Daisuke;
Nakamura, Ryo;
Nakazawa, Kazuhiro;
Noda, Hirofumi;
Odaka, Hirokazu;
Ohta, Masayuki;
Onishi, Mitsunobu;
Saito, Shinya;
Sato, Goro;
Sato, Tamotsu;
Takahashi, Tadayuki;
Tanaka, Takaaki;
Togo, Atsushi;
Tomizuka, Shinji
Submitted: 2015-09-02
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard
ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level
10 times better than instruments currently in orbit. The SGD achieves low
background by combining a Compton camera scheme with a narrow field-of-view
active shield. The Compton camera in the SGD is realized as a hybrid
semiconductor detector system which consists of silicon and cadmium telluride
(CdTe) sensors. The design of the SGD Compton camera has been finalized and the
final prototype, which has the same configuration as the flight model, has been
fabricated for performance evaluation. The Compton camera has overall
dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel
sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel
sensors. The detection efficiency of the Compton camera reaches about 15% and
3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si
and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed
by 208 ASICs developed for the SGD. Good energy resolution is afforded by
semiconductor sensors and low noise ASICs, and the obtained energy resolutions
with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV
and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good
background rejection capability due to better constraints on Compton
kinematics. Compton camera energy resolutions achieved with the final prototype
are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively,
which satisfy the instrument requirements for the SGD Compton camera (better
than 2%). Moreover, a low intrinsic background has been confirmed by the
background measurement with the final prototype.
[2]
oai:arXiv.org:1505.03552 [pdf] - 1021979
Lifetime and Spectral Evolution of a Magma Ocean with a Steam
Atmosphere: Its Detectability by Future Direct Imaging
Submitted: 2015-05-13
We present the thermal evolution and emergent spectra of solidifying
terrestrial planets along with the formation of steam atmospheres. The lifetime
of a magma ocean and its spectra through a steam atmosphere depends on the
orbital distance of the planet from the host star. For a type-I planet, which
is formed beyond a certain critical distance from the host star, the thermal
emission declines on a timescale shorter than approximately $10^6$ years.
Therefore, young stars should be targets when searching for molten planets in
this orbital region. In contrast, a type-II planet, which is formed inside the
critical distance, will emit significant thermal radiation from near-infrared
atmospheric windows during the entire lifetime of the magma ocean. The Ks and L
bands will be favorable for future direct imaging because the planet-to-star
contrasts of these bands are higher than approximately 10$^{-7}$-10$^{-8}$. Our
model predicts that, in the type-II orbital region, molten planets would be
present over the main sequence of the G-type host star if the initial bulk
content of water exceeds approximately 1 wt%. In visible atmospheric windows,
the contrasts of the thermal emission drop below $10^{-10}$ in less than $10^5$
years, whereas those of the reflected light remain $10^{-10}$ for both types of
planets. Since the contrast level is comparable to those of reflected light
from Earth-sized planets in the habitable zone, the visible reflected light
from molten planets also provides a promising target for direct imaging with
future ground- and space-based telescopes.
[3]
oai:arXiv.org:0811.0415 [pdf] - 18145
High energy resolution hard X-ray and gamma-ray imagers using CdTe diode
devices
Watanabe, Shin;
Ishikawa, Shin-nosuke;
Aono, Hiroyuki;
Takeda, Shin'ichiro;
Odaka, Hirokazu;
Kokubun, Motohide;
Takahashi, Tadayuki;
Nakazawa, Kazuhiro;
Tajima, Hiroyasu;
Onishi, Mitsunobu;
Kuroda, Yoshikatsu
Submitted: 2008-11-03
We developed CdTe double-sided strip detectors (DSDs or cross strip
detectors) and evaluated their spectral and imaging performance for hard X-rays
and gamma-rays. Though the double-sided strip configuration is suitable for
imagers with a fine position resolution and a large detection area, CdTe diode
DSDs with indium (In) anodes have yet to be realized due to the difficulty
posed by the segmented In anodes. CdTe diode devices with aluminum (Al) anodes
were recently established, followed by a CdTe device in which the Al anodes
could be segmented into strips. We developed CdTe double-sided strip devices
having Pt cathode strips and Al anode strips, and assembled prototype CdTe
DSDs. These prototypes have a strip pitch of 400 micrometer. Signals from the
strips are processed with analog ASICs (application specific integrated
circuits). We have successfully performed gamma-ray imaging spectroscopy with a
position resolution of 400 micrometer. Energy resolution of 1.8 keV (FWHM: full
width at half maximum) was obtained at 59.54 keV. Moreover, the possibility of
improved spectral performance by utilizing the energy information of both side
strips was demonstrated. We designed and fabricated a new analog ASIC, VA32TA6,
for the readout of semiconductor detectors, which is also suitable for DSDs. A
new feature of the ASIC is its internal ADC function. We confirmed this
function and good noise performance that reaches an equivalent noise charge of
110 e- under the condition of 3-4 pF input capacitance.