Normalized to: Olivieri, E.
[1]
oai:arXiv.org:2003.01046 [pdf] - 2057126
First germanium-based constraints on sub-MeV Dark Matter with the
EDELWEISS experiment
EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Elkhoury, E.;
Fillipini, J. -B.;
Filosofov, D.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Lattaud, H.;
Marnieros, S.;
Misiak, D.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Oriol, C.;
Pari, P.;
Paul, B.;
Poda, D.;
Rozov, S.;
Salagnac, T.;
Sanglard, V.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zolotarova, A.
Submitted: 2020-03-02
The EDELWEISS collaboration has performed a search for Dark Matter (DM)
particles interacting with electrons using a 33.4 g Ge cryogenic detector
operated underground at the LSM. A charge resolution of 0.53 electron-hole
pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification
with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$
DM particles interacting with electrons, as well as on dark photons down to 1
eV/c$^2$. These are competitive with other searches. In particular, new limits
are set on the kinetic mixing of dark photon DM in a so far unconstrained
parameter space region in the 6 to 9 eV/c$^2$ mass range. These results
demonstrate the high relevance of cryogenic Ge detectors for the search of DM
interactions producing eV-scale electron signals.
[2]
oai:arXiv.org:2001.10272 [pdf] - 2065386
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Battistelli, E. S.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Baù, A.;
Bèlier, B.;
Bennett, D.;
Bergè, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Dheilly, S.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
Garcìa, B.;
Redondo, M. E. Garcìa;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gòmez;
Gonzàlez, M.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillè, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Marty, W.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
Olivieri, E.;
Oriol, C.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Prèle, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Salum, J. M.;
Schillaci, A.;
Scòccola, C.;
Scully, S.;
Spinelli, S.;
Stankowiak, G.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Thermeau, J. -P.;
Timbie, P.;
Tomasi, M.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2020-01-28
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative
experiment designed to measure the polarization of the Cosmic Microwave
Background and in particular the signature left therein by the inflationary
expansion of the Universe. The expected signal is extremely faint, thus extreme
sensitivity and systematic control are necessary in order to attempt this
measurement. QUBIC addresses these requirements using an innovative approach
combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with
the deep control of systematics characteristic of interferometers. This makes
QUBIC unique with respect to others classical imagers experiments devoted to
the CMB polarization. In this contribution we report a description of the QUBIC
instrument including recent achievements and the demonstration of the
bolometric interferometry performed in lab. QUBIC will be deployed at the
observation site in Alto Chorrillos, in Argentina at the end of 2019.
[3]
oai:arXiv.org:1911.12418 [pdf] - 2011325
QUBIC: using NbSi TESs with a bolometric interferometer to characterize
the polarisation of the CMB
Piat, M.;
Bélier, B.;
Bergé, L.;
Bleurvacq, N.;
Chapron, C.;
Dheilly, S.;
Dumoulin, L.;
González, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Henrot-Versillé, S.;
Hoang, D. T.;
Marnieros, S.;
Marty, W.;
Montier, L.;
Olivieri, E.;
Oriol, C.;
Perbost, C.;
Prêle, D.;
Rambaud, D.;
Salatino, M.;
Stankowiak, G.;
Thermeau, J. -P.;
Torchinsky, S.;
Voisin, F.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bennett, D.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
García, B.;
Redondo, M. E. García;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gómez;
Gradziel, M.;
Harari, D.;
Haynes, V.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Puddu, R.;
Ringegni, P.;
Romero, G. E.;
Salum, J. M.;
Schillaci, A.;
Scóccola, C.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tomasi, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2019-11-27, last modified: 2019-12-09
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international
ground-based experiment dedicated in the measurement of the polarized
fluctuations of the Cosmic Microwave Background (CMB). It is based on
bolometric interferometry, an original detection technique which combine the
immunity to systematic effects of an interferometer with the sensitivity of low
temperature incoherent detectors. QUBIC will be deployed in Argentina, at the
Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta
province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors
(TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain
Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at
1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K
allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a
reduced number of detectors before upgrading to the full instrument. I will
present the last results of this characterization phase with a focus on the
detectors and readout system.
[4]
oai:arXiv.org:1901.03588 [pdf] - 1871473
Searching for low-mass dark matter particles with a massive Ge bolometer
operated above-ground
Armengaud, E.;
Augier, C.;
Benoît, A.;
Benoit, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapelier, M.;
Charlieux, F.;
Ducimetière, D.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
De Jésus, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Maisonobe, R.;
Marnieros, S.;
Misiak, D.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Oriol, C.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zolotarova, A.;
Kavanagh, B. J.
Submitted: 2019-01-11, last modified: 2019-04-02
The EDELWEISS collaboration has performed a search for dark matter particles
with masses below the GeV-scale with a 33.4-g germanium cryogenic detector
operated in a surface lab. The energy deposits were measured using a
neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline
heat energy resolution leading to a 60~eV analysis energy threshold. Despite a
moderate lead shielding and the high-background environment, the first sub-GeV
spin-independent dark matter limit based on a germanium target has been
achieved. The experiment provides the most stringent, nuclear recoil based,
above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The
experiment also provides the most stringent limits on spin-dependent
interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the
dark matter search results were studied in the context of Strongly Interacting
Massive Particles, taking into account Earth-shielding effects, for which new
regions of the available parameter space have been excluded. Finally, the dark
matter search has also been extended to interactions via the Migdal effect,
resulting for the first time in the exclusion of particles with masses between
45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from
$10^{-29}$ to $10^{-26}$~cm$^2$.
[5]
oai:arXiv.org:1812.00785 [pdf] - 1820173
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric
Interferometer
Mennella, Aniello;
Ade, Peter;
Amico, Giorgio;
Auguste, Didier;
Aumont, Jonathan;
Banfi, Stefano;
Barbaràn, Gustavo;
Battaglia, Paola;
Battistelli, Elia;
Baù, Alessandro;
Bélier, Benoit;
Bennett, David G.;
Bergé, Laurent;
Bernard, Jean Philippe;
Bersanelli, Marco;
Sazy, Marie Anne Bigot;
Bleurvacq, Nathat;
Bonaparte, Juan;
Bonis, Julien;
Bunn, Emory F.;
Burke, David;
Buzi, Daniele;
Buzzelli, Alessandro;
Cavaliere, Francesco;
Chanial, Pierre;
Chapron, Claude;
Charlassier, Romain;
Columbro, Fabio;
Coppi, Gabriele;
Coppolecchia, Alessandro;
D'Agostino, Rocco;
D'Alessandro, Giuseppe;
De Bernardis, Paolo;
De Gasperis, Giancarlo;
De Leo, Michele;
De Petris, Marco;
Di Donato, Andres;
Dumoulin, Louis;
Etchegoyen, Alberto;
Fasciszewski, Adrián;
Franceschet, Cristian;
Lerena, Martin Miguel Gamboa;
Garcia, Beatriz;
Garrido, Xavier;
Gaspard, Michel;
Gault, Amanda;
Gayer, Donnacha;
Gervasi, Massimo;
Giard, Martin;
Héraud, Yannick Giraud;
Berisso, Mariano Gómez;
González, Manuel;
Gradziel, Marcin;
Grandsire, Laurent;
Guerard, Eric;
Hamilton, Jean Christophe;
Harari, Diego;
Haynes, Vic;
Versillé, Sophie Henrot;
Hoang, Duc Thuong;
Holtzer, Nicolas;
Incardona, Federico;
Jules, Eric;
Kaplan, Jean;
Korotkov, Andrei;
Kristukat, Christian;
Lamagna, Luca;
Loucatos, Soutiris;
Lowitz, Amy;
Lukovic, Vladimir;
Thibault, Louis;
Luterstein, Raùl Horacio;
Maffei, Bruno;
Marnieros, Stefanos;
Masi, Silvia;
Mattei, Angelo;
May, Andrew;
McCulloch, Mark;
Medina, Maria C.;
Mele, Lorenzo;
Melhuish, Simon J.;
Montier, Ludovic;
Mousset, Louise;
Mundo, Luis Mariano;
Murphy, John Anthony;
Murphy, James;
O'Sullivan, Creidhe;
Olivieri, Emiliano;
Paiella, Alessandro;
Pajot, Francois;
Passerini, Andrea;
Pastoriza, Hernan;
Pelosi, Alessandro;
Perbost, Camille;
Perciballi, Maurizio;
Pezzotta, Federico;
Piacentini, Francesco;
Piat, Michel;
Piccirillo, Lucio;
Pisano, Giampaolo;
Polenta, Gianluca;
Prêle, Damien;
Puddu, Roberto;
Rambaud, Damien;
Ringegni, Pablo;
Romero, Gustavo E.;
Salatino, Maria;
Schillaci, Alessandro;
Scóccola, Claudia G.;
Scully, Stephen P.;
Spinelli, Sebastiano;
Stolpovskiy, Michail;
Suarez, Federico;
Stankowiak, Guillaume;
Tartari, Andrea;
Thermeau, Jean Pierre;
Timbie, Peter;
Tomasi, Maurizio;
Torchinsky, Steve A.;
Tristram, Mathieu;
Tucker, Gregory S.;
Tucker, Carole E.;
Vanneste, Sylvain;
Viganò, Daniele;
Vittorio, Nicola;
Voisin, Fabrice;
Watson, Robert;
Wicek, Francois;
Zannoni, Mario;
Zullo, Antonio
Submitted: 2018-11-30, last modified: 2019-01-23
In this paper we describe QUBIC, an experiment that will observe the
polarized microwave sky with a novel approach, which combines the sensitivity
of state-of-the art bolometric detectors with the systematic effects control
typical of interferometers. QUBIC unique features are the so-called
"self-calibration", a technique that allows us to clean the measured data from
instrumental effects, and its spectral imaging power, i.e. the ability to
separate the signal in various sub-bands within each frequency band. QUBIC will
observe the sky in two main frequency bands: 150 GHz and 220 GHz. A
technological demonstrator is currently under testing and will be deployed in
Argentina during 2019, while the final instrument is expected to be installed
during 2020.
[6]
oai:arXiv.org:1811.02296 [pdf] - 1779826
Thermal architecture for the QUBIC cryogenic receiver
May, A. J.;
Chapron, C.;
Coppi, G.;
D'Alessandro, G.;
de Bernardis, P.;
Masi, S.;
Melhuish, S.;
Piat, M.;
Piccirillo, L.;
Schillaci, A.;
Thermeau, J. -P.;
Ade, P.;
Amico, G.;
Auguste, D.;
Aumont, J.;
Banfi, S.;
Barbara, G.;
Battaglia, P.;
Battistelli, E.;
Bau, A.;
Belier, B.;
Bennett, D.;
Berge, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bordier, G.;
Breelle, E.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Garcia, B.;
Garrido, X.;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Giraud-Heraud, Y.;
Berisso, M. Gomez;
Gonzalez, M.;
Gradziel, M.;
Grandsire, L.;
Guerrard, E.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versille, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Lowitz, A.;
Lukovic, V.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Mattei, A.;
McCulloch, M. A.;
Medina, M. C.;
Mele, L.;
Mennella, A.;
Montier, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
O'Sullivan, C.;
Olivieri, E.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Pezzotta, F.;
Piacentini, F.;
Pisano, G.;
Polenta, G.;
Prele, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Scoccola, C. G.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S. A.;
Tristram, M.;
Truongcanh, V.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Vigano, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-11-06
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming
instrument to measure the B-mode polarization anisotropy of the Cosmic
Microwave Background. The detection of the B-mode signal will be extremely
challenging; QUBIC has been designed to address this with a novel approach,
namely bolometric interferometry. The receiver cryostat is exceptionally large
and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK
using two pulse tube coolers, a novel 4He sorption cooler and a double-stage
3He/4He sorption cooler. We discuss the thermal and mechanical design of the
cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
[7]
oai:arXiv.org:1707.04308 [pdf] - 1622237
Optimizing EDELWEISS detectors for low-mass WIMP searches
EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Maisonobe, R.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2017-07-11
The physics potential of EDELWEISS detectors for the search of low-mass
Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven
background model, projected exclusion limits are computed using frequentist and
multivariate analysis approaches, namely profile likelihood and boosted
decision tree. Both current and achievable experimental performance are
considered. The optimal strategy for detector optimization depends critically
on whether the emphasis is put on WIMP masses below or above $\sim$ 5
GeV/c$^2$. The projected sensitivity for the next phase of the EDELWEISS-III
experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search
is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon
cross-section of $\sigma_{SI} = 7 \times 10^{-42}$ cm$^2$ is expected for a
WIMP mass in the range 2$-$5 GeV/c$^2$. The requirements for a future
hundred-kilogram scale experiment designed to reach the bounds imposed by the
coherent scattering of solar neutrinos are also described. By improving the
ionization resolution down to 50 eV$_{ee}$, we show that such an experiment
installed in an even lower background environment (e.g. at SNOLAB) should allow
to observe about 80 $^8$B neutrino events after discrimination.
[8]
oai:arXiv.org:1706.01070 [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter
searches
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Maisonobe, R.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.;
Zolotarova, A.
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the
EDELWEISS-III array of cryogenic germanium detectors for direct dark matter
searches. The experimental setup and the FID (Fully Inter-Digitized) detector
array is described, as well as the efficiency of the double measurement of heat
and ionization signals in background rejection. For the whole set of 24 FID
detectors used for coincidence studies, the baseline resolutions for the
fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the
baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM).
The response to nuclear recoils as well as the very good discrimination
capability of the FID design has been measured with an AmBe source. The surface
$\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times
10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source,
the rejection of bulk $\gamma$-ray events has been demonstrated using
$\gamma$-calibrations with $^{133}$Ba sources leading to a value of
$R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels
of natural radioactivity measured in the detector array are shown as the rate
of single $\gamma$ background. The fiducial volume fraction of the FID
detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$
using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The
stability and uniformity of the detector response is also discussed. The
achieved resolutions, thresholds and background levels of the upgraded
EDELWEISS-III detectors in their setup are thus well suited to the direct
search of WIMP dark matter over a large mass range.
[9]
oai:arXiv.org:1607.03367 [pdf] - 1497465
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile
likelihood approach
EDELWEISS Collaboration;
Hehn, L.;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-12, last modified: 2016-09-20
We report on a dark matter search for a Weakly Interacting Massive Particle
(WIMP) in the mass range $m_\chi \in [4, 30]\,\mathrm{GeV}/c^2$ with the
EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data
from eight selected detectors with the lowest energy thresholds leading to a
combined fiducial exposure of 496 kg-days. External backgrounds from $\gamma$-
and $\beta$-radiation, recoils from $^{206}$Pb and neutrons as well as detector
intrinsic backgrounds were modelled from data outside the region of interest
and constrained in the analysis. The basic data selection and most of the
background models are the same as those used in a previously published analysis
based on Boosted Decision Trees (BDT). For the likelihood approach applied in
the analysis presented here, a larger signal efficiency and a subtraction of
the expected background lead to a higher sensitivity, especially for the lowest
WIMP masses probed. No statistically significant signal was found and upper
limits on the spin-independent WIMP-nucleon scattering cross section can be set
with a hypothesis test based on the profile likelihood test statistics. The 90%
C.L. exclusion limit set for WIMPs with $m_\chi = 4\,\mathrm{GeV/}c^2$ is $1.6
\times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven
with respect to the BDT-based analysis. For WIMP masses above
$15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in
good agreement.
[10]
oai:arXiv.org:1607.04560 [pdf] - 1438577
Measurement of the cosmogenic activation of germanium detectors in
EDELWEISS-III
The EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-15
We present a measurement of the cosmogenic activation in the germanium
cryogenic detectors of the EDELWEISS III direct dark matter search experiment.
The decay rates measured in detectors with different exposures to cosmic rays
above ground are converted into production rates of different isotopes. The
measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H,
2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for
$^{65}$Zn. These results are the most accurate for these isotopes. A lower
limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also
presented. They are compared to model predictions present in literature and to
estimates calculated with the ACTIVIA code.
[11]
oai:arXiv.org:1606.08097 [pdf] - 1507589
Signals induced by charge-trapping in EDELWEISS FID detectors:
analytical modeling and applications
The EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Fourches, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
De Jésus, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kéfélian, C.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-06-26, last modified: 2016-06-29
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge
detectors Fully covered with Inter-Digitized electrodes (FID). They are
operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence
charge-carrier trapping significantly affects both the ionization and heat
energy measurements. This paper describes an analytical model of the signals
induced by trapped charges in FID detectors based on the Shockley-Ramo theorem.
It is used to demonstrate that veto electrodes, initially designed for the sole
purpose of surface event rejection, can be used to provide a sensitivity to the
depth of the energy deposits, characterize the trapping in the crystals,
perform heat and ionization energy corrections and improve the ionization
baseline resolutions. These procedures are applied successfully to actual data.
[12]
oai:arXiv.org:1603.05120 [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
De Jésus, M.;
Jin, Y.;
Jokisch, S.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D. V.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
[13]
oai:arXiv.org:1307.5701 [pdf] - 1172881
Latest Progress on the QUBIC Instrument
Ghribi, A.;
Aumont, J.;
Battistelli, E. S.;
Bau, A.;
Bergé, L.;
Bernard, J-Ph.;
Bersanelli, M.;
Bigot-Sazy, M-A.;
Bordier, G.;
Bunn, E. T.;
Cavaliere, F.;
Chanial, P.;
Coppolecchia, A.;
Decourcelle, T.;
De Bernardis, P.;
De Petris, M.;
Drilien, A-A.;
Dumoulin, L.;
Falvella, M. C.;
Gault, A.;
Gervasi, M.;
Giard, M.;
Gradziel, M.;
Grandsire, L.;
Gayer, D.;
Hamilton, J-Ch.;
Haynes, V.;
Giraud-Héraud, Y.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lande, J.;
Lowitz, A.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Ng, M. W.;
Olivieri, E.;
Pajot, F.;
Passerini, A.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Rambaud, D.;
Rigaut, O.;
Rosset, C.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
O'Sullivan, C.;
Tartari, A.;
Timbie, P.;
Tucker, G.;
Vibert, L.;
Voisin, F.;
Watson, B.;
Zannoni, M.
Submitted: 2013-07-22, last modified: 2013-11-12
QUBIC is a unique instrument that crosses the barriers between classical
imaging architectures and interferometry taking advantage from both for high
sensitivity and systematics mitigation. The scientific target is the detection
of the primordial gravitational waves imprint on the Cosmic Microwave
Background which are the proof of inflation, holy grail of modern cosmology. In
this paper, we show the latest advances in the development of the architecture
and the sub-systems of the first module of this instrument to be deployed in
Dome Charlie Concordia base - Antarctica in 2015.
[14]
oai:arXiv.org:1307.1488 [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoit, A.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
de Boissière, T.;
De Jesus, M.;
Dolgorouky, Y.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Holtzer, N.;
Humbert, V.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Mancuso, M.;
Marrache-Kikuchi, C.;
Marnieros, S.;
Menshikov, A.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. C.;
Rigaut, O.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Tenconi, M.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more
indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times
g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the
effective axion-nucleon coupling for $^{57}$Fe. Combining these results we
fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and
$5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.
[15]
oai:arXiv.org:1304.4611 [pdf] - 653466
Astrophysical and cosmological problems of invisible mass and dark
energy in the Universe
Belli, P.;
Berdina, L. A.;
Bernabei, R.;
Bogdan, A.;
Boiko, R. S.;
Burgazli, A. Yu.;
Cappella, F.;
Cerulli, R.;
Chernyak, D. M.;
Danevich, F. A.;
d'Angelo, A.;
Eingorn, M. V.;
Fakhr, S. H.;
Fedorova, E.;
Galashov, E. N.;
Giuliani, A.;
Hnatyk, B. I.;
Incicchitti, A.;
Ivashchenko, G.;
Kobychev, V. V.;
Kobzar, O. O.;
Kraus, H.;
Kropivyansky, B. N.;
Kudinova, A. V.;
Kulinich, Yu. A.;
Laubenstein, M.;
Marchenko, V. V.;
Marnieros, S.;
Mikhailik, V. B.;
Minakov, A. A.;
Mokina, V. M.;
Nagornaya, L. L.;
Nikolaiko, A. S.;
Nones, C.;
Novosyadlyj, B. S.;
Olivieri, E.;
Pelykh, V. O.;
Poda, D. V.;
Podviyanuk, R. B.;
Polischuk, O. G.;
Sergijenko, O. N.;
Shlegel, V. N.;
Shulga, V. M.;
Sliusar, V. M.;
Sushchov, O. B.;
Taistra, Y. V.;
Tenconi, M.;
Torbaniuk, O.;
Tretyak, V. I.;
Tsvetkova, V. S.;
Vakulik, V. G.;
Vasiliev, Ya. V.;
Vasylenko, A.;
Vasylenko, O.;
Zhdanov, V. I.;
Zhuk, A. I.
Submitted: 2013-04-16
The Workshop on results of the Project Kosmomikrofizyka-2 (Astroparticle
Physics) of the National Academy of Sciences (NAS) of Ukraine "Astrophysical
and cosmological problems of invisible mass and dark energy in the Universe"
was held on November 21-22, 2012 in the Institute for Nuclear Research, Kyiv,
Ukraine (http://lpd.kinr.kiev.ua/kmf12). This Project was carried out during
three years (2010-2012) by scientists from various universities and institutes
of the National Academy of Sciences of Ukraine; it was a logical continuation
of the previous scientific program of the NAS of Ukraine "Researches of
structure and composition of the Universe, hidden mass and dark energy
(Kosmomikrofizyka)" in 2007-2009. These programs were devoted to theoretical
and experimental investigations in astronomy, astrophysics, cosmology, physics
of atomic nuclei and particle physics, which are related with the problems of
dark matter and dark energy in the Universe.
[16]
oai:arXiv.org:1302.7112 [pdf] - 633724
Muon-induced background in the EDELWEISS dark matter search
The EDELWEISS collaboration;
Schmidt, B.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Collin, S.;
Coulter, P.;
Cox, G. A.;
Crauste, O.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Juillard, A.;
Kluck, H.;
Kozlov, V. Y.;
Kleifges, M.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nieder, H.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrentó-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-02-28
A dedicated analysis of the muon-induced background in the EDELWEISS dark
matter search has been performed on a data set acquired in 2009 and 2010. The
total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was
measured to be $\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The
modular design of the muon-veto system allows the reconstruction of the muon
trajectory and hence the determination of the angular dependent muon flux in
LSM. The results are in good agreement with both MC simulations and earlier
measurements. Synchronization of the muon-veto system with the phonon and
ionization signals of the Ge detector array allowed identification of
muon-induced events. Rates for all muon-induced events $\Gamma^{\mu}=(0.172 \pm
0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $\Gamma^{\mu-n} =
0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After
vetoing, the remaining rate of accepted muon-induced neutrons in the
EDELWEISS-II dark matter search was determined to be $\Gamma^{\mu-n}_{\rm
irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on
these results, the muon-induced background expectation for an anticipated
exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{\mu-n}_{3000 kg\cdot d} < 0.6$
events.
[17]
oai:arXiv.org:1207.1815 [pdf] - 568705
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization
detectors
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
Domange, J.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Heuermann, G.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrento-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2012-07-07, last modified: 2012-09-05
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear
recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium
detectors equipped with thermal sensors and an electrode design (ID) which
allows to efficiently reject several sources of background. The data indicate
no evidence for an exponential distribution of low-energy nuclear recoils that
could be attributed to WIMP elastic scattering after an exposure of 113 kg.d.
For WIMPs of mass 10 GeV, the observation of one event in the WIMP search
region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent
WIMP-nucleon scattering cross-section, which constrains the parameter space
associated with the findings reported by the CoGeNT, DAMA and CRESST
experiments.
[18]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[19]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[20]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[21]
oai:arXiv.org:1001.4383 [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Rozov, S.;
Armengaud, E.;
Augier, C.;
Bergé, L.;
Benoit, A.;
Besida, O.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Defay, X.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrach, C.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M-A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the
LSM underground laboratory in proximity of the EDELWEISS-II dark matter search
experiment together with short measurements at various other locations.
Monitoring of the flux of thermal neutrons is accomplished using a mobile
detection system with low background proportional counter filled with $^3$He.
On average 75 neutrons per day are detected with a background level below 1
count per day (cpd). This provides a unique possibility of a day by day study
of variations of the neutron field in a deep underground site. The measured
average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is
$\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We
report the first experimental observation that the point-to-point thermal
neutron flux at LSM varies by more than a factor two.
[22]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[23]
oai:arXiv.org:0905.0753 [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Broniatowski, A.;
Defay, X.;
Armengaud, E.;
Berge, L.;
Benoit, A.;
Besida, O.;
Blumer, J.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrache, C.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M. -A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is
presented, taking advantage of the coplanar grid technique of event
localisation for improved background discrimination. Experiments performed with
prototype devices in the EDELWEISS II setup at the Modane underground facility
demonstrate the remarkably high efficiency of these devices for the rejection
of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate
the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as
proposed in the EURECA project of a one-ton cryogenic detector mass.
[24]
oai:arXiv.org:astro-ph/0607502 [pdf] - 83705
Measurement of the response of heat-and-ionization germanium detectors
to nuclear recoils
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chantelauze, A.;
/Chapellier, M.;
Chardin, G.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Gros, M.;
Horn, M.;
Juillard, A.;
Lemrani, R.;
de Lesquen, A.;
Luca, M.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Olivieri, E.;
Pari, P.;
Sanglard, V.;
Schoeffel, L.;
Schwamm, F.;
Stern, M.
Submitted: 2006-07-21
The heat quenching factor Q' (the ratio of the heat signals produced by
nuclear and electron recoils of equal energy) of the heat-and-ionization
germanium bolometers used by the EDELWEISS collaboration has been measured. It
is explained how this factor affects the energy scale and the effective
quenching factor observed in calibrations with neutron sources. This effective
quenching effect is found to be equal to Q/Q', where Q is the quenching factor
of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q'
is combined with values of Q obtained from a review of all available
measurements of this quantity in tagged neutron beam experiments. The
systematic uncertainties associated with this method to evaluate Q' are
discussed in detail. For recoil energies between 20 and 100 keV, the resulting
heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the
contributions from the Q and Q/Q' measurements, respectively. The present
compilation of Q values and evaluation of Q' represent one of the most precise
determinations of the absolute energy scale for any detector used in direct
searches for dark matter.