sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Olivieri, E.

Normalized to: Olivieri, E.

24 article(s) in total. 423 co-authors, from 1 to 24 common article(s). Median position in authors list is 36,5.

[1]  oai:arXiv.org:2003.01046  [pdf] - 2057126
First germanium-based constraints on sub-MeV Dark Matter with the EDELWEISS experiment
Comments: 6 pages, 4 figures
Submitted: 2020-03-02
The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting with electrons, as well as on dark photons down to 1 eV/c$^2$. These are competitive with other searches. In particular, new limits are set on the kinetic mixing of dark photon DM in a so far unconstrained parameter space region in the 6 to 9 eV/c$^2$ mass range. These results demonstrate the high relevance of cryogenic Ge detectors for the search of DM interactions producing eV-scale electron signals.
[2]  oai:arXiv.org:2001.10272  [pdf] - 2065386
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Battistelli, E. S.; Ade, P.; Alberro, J. G.; Almela, A.; Amico, G.; Arnaldi, L. H.; Auguste, D.; Aumont, J.; Azzoni, S.; Banfi, S.; Battaglia, P.; Baù, A.; Bèlier, B.; Bennett, D.; Bergè, L.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bleurvacq, N.; Bonaparte, J.; Bonis, J.; Bottani, A.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Chapron, C.; Charlassier, R.; Columbro, F.; Coppi, G.; Coppolecchia, A.; D'Alessandro, G.; de Bernardis, P.; De Gasperis, G.; De Leo, M.; De Petris, M.; Dheilly, S.; Di Donato, A.; Dumoulin, L.; Etchegoyen, A.; Fasciszewski, A.; Ferreyro, L. P.; Fracchia, D.; Franceschet, C.; Lerena, M. M. Gamboa; Ganga, K.; Garcìa, B.; Redondo, M. E. Garcìa; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Gilles, V.; Giraud-Heraud, Y.; Berisso, M. Gòmez; Gonzàlez, M.; Gradziel, M.; Grandsire, L.; Hamilton, J. -Ch.; Harari, D.; Haynes, V.; Henrot-Versillè, S.; Hoang, D. T.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Luterstein, R.; Maffei, B.; Marnieros, S.; Marty, W.; Masi, S.; Mattei, A.; May, A.; McCulloch, M.; Medina, M. C.; Mele, L.; Melhuish, S.; Mennella, A.; Montier, L.; Mousset, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; Nati, F.; Olivieri, E.; Oriol, C.; O'Sullivan, C.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perbost, C.; Perciballi, M.; Pezzotta, F.; Piacentini, F.; Piat, M.; Piccirillo, L.; Pisano, G.; Platino, M.; Polenta, G.; Prèle, D.; Puddu, R.; Rambaud, D.; Ringegni, P.; Romero, G. E.; Salatino, M.; Salum, J. M.; Schillaci, A.; Scòccola, C.; Scully, S.; Spinelli, S.; Stankowiak, G.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Thermeau, J. -P.; Timbie, P.; Tomasi, M.; Torchinsky, S.; Tristram, M.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganò, D.; Vittorio, N.; Voisin, F.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments: Accepted for publication in the Journal of Low Temperature Physics
Submitted: 2020-01-28
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.
[3]  oai:arXiv.org:1911.12418  [pdf] - 2011325
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
Piat, M.; Bélier, B.; Bergé, L.; Bleurvacq, N.; Chapron, C.; Dheilly, S.; Dumoulin, L.; González, M.; Grandsire, L.; Hamilton, J. -Ch.; Henrot-Versillé, S.; Hoang, D. T.; Marnieros, S.; Marty, W.; Montier, L.; Olivieri, E.; Oriol, C.; Perbost, C.; Prêle, D.; Rambaud, D.; Salatino, M.; Stankowiak, G.; Thermeau, J. -P.; Torchinsky, S.; Voisin, F.; Ade, P.; Alberro, J. G.; Almela, A.; Amico, G.; Arnaldi, L. H.; Auguste, D.; Aumont, J.; Azzoni, S.; Banfi, S.; Battaglia, P.; Battistelli, E. S.; Baù, A.; Bennett, D.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bonaparte, J.; Bonis, J.; Bottani, A.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Charlassier, R.; Columbro, F.; Coppi, G.; Coppolecchia, A.; D'Alessandro, G.; de Bernardis, P.; De Gasperis, G.; De Leo, M.; De Petris, M.; Di Donato, A.; Etchegoyen, A.; Fasciszewski, A.; Ferreyro, L. P.; Fracchia, D.; Franceschet, C.; Lerena, M. M. Gamboa; Ganga, K.; García, B.; Redondo, M. E. García; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Gilles, V.; Giraud-Heraud, Y.; Berisso, M. Gómez; Gradziel, M.; Harari, D.; Haynes, V.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Luterstein, R.; Maffei, B.; Masi, S.; Mattei, A.; May, A.; McCulloch, M.; Medina, M. C.; Mele, L.; Melhuish, S.; Mennella, A.; Mousset, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; Nati, F.; O'Sullivan, C.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perciballi, M.; Pezzotta, F.; Piacentini, F.; Piccirillo, L.; Pisano, G.; Platino, M.; Polenta, G.; Puddu, R.; Ringegni, P.; Romero, G. E.; Salum, J. M.; Schillaci, A.; Scóccola, C.; Scully, S.; Spinelli, S.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Timbie, P.; Tomasi, M.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganò, D.; Vittorio, N.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments: Conference proceedings submitted to the Journal of Low Temperature Physics for LTD18
Submitted: 2019-11-27, last modified: 2019-12-09
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128. The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.
[4]  oai:arXiv.org:1901.03588  [pdf] - 1871473
Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground
Comments: 16 pages, 8 figures. New figure added for Spin-Dependent interactions. Accepted in Phys. Rev. D
Submitted: 2019-01-11, last modified: 2019-04-02
The EDELWEISS collaboration has performed a search for dark matter particles with masses below the GeV-scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline heat energy resolution leading to a 60~eV analysis energy threshold. Despite a moderate lead shielding and the high-background environment, the first sub-GeV spin-independent dark matter limit based on a germanium target has been achieved. The experiment provides the most stringent, nuclear recoil based, above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The experiment also provides the most stringent limits on spin-dependent interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the dark matter search results were studied in the context of Strongly Interacting Massive Particles, taking into account Earth-shielding effects, for which new regions of the available parameter space have been excluded. Finally, the dark matter search has also been extended to interactions via the Migdal effect, resulting for the first time in the exclusion of particles with masses between 45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from $10^{-29}$ to $10^{-26}$~cm$^2$.
[5]  oai:arXiv.org:1812.00785  [pdf] - 1820173
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric Interferometer
Mennella, Aniello; Ade, Peter; Amico, Giorgio; Auguste, Didier; Aumont, Jonathan; Banfi, Stefano; Barbaràn, Gustavo; Battaglia, Paola; Battistelli, Elia; Baù, Alessandro; Bélier, Benoit; Bennett, David G.; Bergé, Laurent; Bernard, Jean Philippe; Bersanelli, Marco; Sazy, Marie Anne Bigot; Bleurvacq, Nathat; Bonaparte, Juan; Bonis, Julien; Bunn, Emory F.; Burke, David; Buzi, Daniele; Buzzelli, Alessandro; Cavaliere, Francesco; Chanial, Pierre; Chapron, Claude; Charlassier, Romain; Columbro, Fabio; Coppi, Gabriele; Coppolecchia, Alessandro; D'Agostino, Rocco; D'Alessandro, Giuseppe; De Bernardis, Paolo; De Gasperis, Giancarlo; De Leo, Michele; De Petris, Marco; Di Donato, Andres; Dumoulin, Louis; Etchegoyen, Alberto; Fasciszewski, Adrián; Franceschet, Cristian; Lerena, Martin Miguel Gamboa; Garcia, Beatriz; Garrido, Xavier; Gaspard, Michel; Gault, Amanda; Gayer, Donnacha; Gervasi, Massimo; Giard, Martin; Héraud, Yannick Giraud; Berisso, Mariano Gómez; González, Manuel; Gradziel, Marcin; Grandsire, Laurent; Guerard, Eric; Hamilton, Jean Christophe; Harari, Diego; Haynes, Vic; Versillé, Sophie Henrot; Hoang, Duc Thuong; Holtzer, Nicolas; Incardona, Federico; Jules, Eric; Kaplan, Jean; Korotkov, Andrei; Kristukat, Christian; Lamagna, Luca; Loucatos, Soutiris; Lowitz, Amy; Lukovic, Vladimir; Thibault, Louis; Luterstein, Raùl Horacio; Maffei, Bruno; Marnieros, Stefanos; Masi, Silvia; Mattei, Angelo; May, Andrew; McCulloch, Mark; Medina, Maria C.; Mele, Lorenzo; Melhuish, Simon J.; Montier, Ludovic; Mousset, Louise; Mundo, Luis Mariano; Murphy, John Anthony; Murphy, James; O'Sullivan, Creidhe; Olivieri, Emiliano; Paiella, Alessandro; Pajot, Francois; Passerini, Andrea; Pastoriza, Hernan; Pelosi, Alessandro; Perbost, Camille; Perciballi, Maurizio; Pezzotta, Federico; Piacentini, Francesco; Piat, Michel; Piccirillo, Lucio; Pisano, Giampaolo; Polenta, Gianluca; Prêle, Damien; Puddu, Roberto; Rambaud, Damien; Ringegni, Pablo; Romero, Gustavo E.; Salatino, Maria; Schillaci, Alessandro; Scóccola, Claudia G.; Scully, Stephen P.; Spinelli, Sebastiano; Stolpovskiy, Michail; Suarez, Federico; Stankowiak, Guillaume; Tartari, Andrea; Thermeau, Jean Pierre; Timbie, Peter; Tomasi, Maurizio; Torchinsky, Steve A.; Tristram, Mathieu; Tucker, Gregory S.; Tucker, Carole E.; Vanneste, Sylvain; Viganò, Daniele; Vittorio, Nicola; Voisin, Fabrice; Watson, Robert; Wicek, Francois; Zannoni, Mario; Zullo, Antonio
Comments: Proceedings of the 2018 ICNFP conference, Crete. Published by Universe arXiv admin note: text overlap with arXiv:1801.03730
Submitted: 2018-11-30, last modified: 2019-01-23
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e. the ability to separate the signal in various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.
[6]  oai:arXiv.org:1811.02296  [pdf] - 1779826
Thermal architecture for the QUBIC cryogenic receiver
May, A. J.; Chapron, C.; Coppi, G.; D'Alessandro, G.; de Bernardis, P.; Masi, S.; Melhuish, S.; Piat, M.; Piccirillo, L.; Schillaci, A.; Thermeau, J. -P.; Ade, P.; Amico, G.; Auguste, D.; Aumont, J.; Banfi, S.; Barbara, G.; Battaglia, P.; Battistelli, E.; Bau, A.; Belier, B.; Bennett, D.; Berge, L.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bleurvacq, N.; Bonaparte, J.; Bonis, J.; Bordier, G.; Breelle, E.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Charlassier, R.; Columbro, F.; Coppolecchia, A.; Couchot, F.; D'Agostino, R.; De Gasperis, G.; De Leo, M.; De Petris, M.; Di Donato, A.; Dumoulin, L.; Etchegoyen, A.; Fasciszewski, A.; Franceschet, C.; Lerena, M. M. Gamboa; Garcia, B.; Garrido, X.; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Giraud-Heraud, Y.; Berisso, M. Gomez; Gonzalez, M.; Gradziel, M.; Grandsire, L.; Guerrard, E.; Hamilton, J. -Ch.; Harari, D.; Haynes, V.; Henrot-Versille, S.; Hoang, D. T.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Lowitz, A.; Lukovic, V.; Luterstein, R.; Maffei, B.; Marnieros, S.; Mattei, A.; McCulloch, M. A.; Medina, M. C.; Mele, L.; Mennella, A.; Montier, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; O'Sullivan, C.; Olivieri, E.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perbost, C.; Perdereau, O.; Pezzotta, F.; Piacentini, F.; Pisano, G.; Polenta, G.; Prele, D.; Puddu, R.; Rambaud, D.; Ringegni, P.; Romero, G. E.; Salatino, M.; Scoccola, C. G.; Scully, S.; Spinelli, S.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Timbie, P.; Torchinsky, S. A.; Tristram, M.; Truongcanh, V.; Tucker, C.; Tucker, G.; Vanneste, S.; Vigano, D.; Vittorio, N.; Voisin, F.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments:
Submitted: 2018-11-06
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
[7]  oai:arXiv.org:1707.04308  [pdf] - 1622237
Optimizing EDELWEISS detectors for low-mass WIMP searches
Comments: 21 pages, 12 figures, submitted to Phys. Rev. D
Submitted: 2017-07-11
The physics potential of EDELWEISS detectors for the search of low-mass Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely profile likelihood and boosted decision tree. Both current and achievable experimental performance are considered. The optimal strategy for detector optimization depends critically on whether the emphasis is put on WIMP masses below or above $\sim$ 5 GeV/c$^2$. The projected sensitivity for the next phase of the EDELWEISS-III experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon cross-section of $\sigma_{SI} = 7 \times 10^{-42}$ cm$^2$ is expected for a WIMP mass in the range 2$-$5 GeV/c$^2$. The requirements for a future hundred-kilogram scale experiment designed to reach the bounds imposed by the coherent scattering of solar neutrinos are also described. By improving the ionization resolution down to 50 eV$_{ee}$, we show that such an experiment installed in an even lower background environment (e.g. at SNOLAB) should allow to observe about 80 $^8$B neutrino events after discrimination.
[8]  oai:arXiv.org:1706.01070  [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter searches
Comments:
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface $\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times 10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source, the rejection of bulk $\gamma$-ray events has been demonstrated using $\gamma$-calibrations with $^{133}$Ba sources leading to a value of $R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single $\gamma$ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$ using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.
[9]  oai:arXiv.org:1607.03367  [pdf] - 1497465
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach
Comments: 11 pages, 6 figures, 2 tables (updated to accepted version)
Submitted: 2016-07-12, last modified: 2016-09-20
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range $m_\chi \in [4, 30]\,\mathrm{GeV}/c^2$ with the EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from $\gamma$- and $\beta$-radiation, recoils from $^{206}$Pb and neutrons as well as detector intrinsic backgrounds were modelled from data outside the region of interest and constrained in the analysis. The basic data selection and most of the background models are the same as those used in a previously published analysis based on Boosted Decision Trees (BDT). For the likelihood approach applied in the analysis presented here, a larger signal efficiency and a subtraction of the expected background lead to a higher sensitivity, especially for the lowest WIMP masses probed. No statistically significant signal was found and upper limits on the spin-independent WIMP-nucleon scattering cross section can be set with a hypothesis test based on the profile likelihood test statistics. The 90% C.L. exclusion limit set for WIMPs with $m_\chi = 4\,\mathrm{GeV/}c^2$ is $1.6 \times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven with respect to the BDT-based analysis. For WIMP masses above $15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in good agreement.
[10]  oai:arXiv.org:1607.04560  [pdf] - 1438577
Measurement of the cosmogenic activation of germanium detectors in EDELWEISS-III
Comments:
Submitted: 2016-07-15
We present a measurement of the cosmogenic activation in the germanium cryogenic detectors of the EDELWEISS III direct dark matter search experiment. The decay rates measured in detectors with different exposures to cosmic rays above ground are converted into production rates of different isotopes. The measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H, 2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for $^{65}$Zn. These results are the most accurate for these isotopes. A lower limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also presented. They are compared to model predictions present in literature and to estimates calculated with the ACTIVIA code.
[11]  oai:arXiv.org:1606.08097  [pdf] - 1507589
Signals induced by charge-trapping in EDELWEISS FID detectors: analytical modeling and applications
Comments: 17 pages 12 figures, submitted to JINST, author list updated
Submitted: 2016-06-26, last modified: 2016-06-29
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trapping significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID detectors based on the Shockley-Ramo theorem. It is used to demonstrate that veto electrodes, initially designed for the sole purpose of surface event rejection, can be used to provide a sensitivity to the depth of the energy deposits, characterize the trapping in the crystals, perform heat and ionization energy corrections and improve the ionization baseline resolutions. These procedures are applied successfully to actual data.
[12]  oai:arXiv.org:1603.05120  [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
Comments: Matches published version
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of 800 g Germanium bolometers equipped with a set of interleaved electrodes with full surface coverage. We searched specifically for $\sim 2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an illustration the number of observed events in the search for 5 (resp. 20) GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1 (resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times 10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a 41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints of WIMP signals from some recent experiments, thus confirming results obtained with different detection techniques.
[13]  oai:arXiv.org:1307.5701  [pdf] - 1172881
Latest Progress on the QUBIC Instrument
Comments: 6 pages, 2 figures, conference LTD15
Submitted: 2013-07-22, last modified: 2013-11-12
QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show the latest advances in the development of the architecture and the sub-systems of the first module of this instrument to be deployed in Dome Charlie Concordia base - Antarctica in 2015.
[14]  oai:arXiv.org:1307.1488  [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Comments:
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS experiment, located at the Underground Laboratory of Modane, primarily aims at the direct detection of WIMPs using germanium bolometers. It is also sensitive to the low-energy electron recoils that would be induced by solar or dark matter axions. Using a total exposure of up to 448 kg.d, we searched for axion-induced electron recoils down to 2.5 keV within four scenarios involving different hypotheses on the origin and couplings of axions. We set a 95% CL limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in a mass range not fully covered by axion helioscopes. We also constrain the coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the effective axion-nucleon coupling for $^{57}$Fe. Combining these results we fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and $5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.
[15]  oai:arXiv.org:1304.4611  [pdf] - 653466
Astrophysical and cosmological problems of invisible mass and dark energy in the Universe
Comments: Proceedings of the Workshop on results of the Project Kosmomikrofizyka-2 (Astroparticle Physics) of the National Academy of Sciences of Ukraine, November 21-22, 2012, Institute for Nuclear Research, Kyiv, Ukraine. 94 pages, 29 figures, 5 tables (in English, Ukrainian, Russian)
Submitted: 2013-04-16
The Workshop on results of the Project Kosmomikrofizyka-2 (Astroparticle Physics) of the National Academy of Sciences (NAS) of Ukraine "Astrophysical and cosmological problems of invisible mass and dark energy in the Universe" was held on November 21-22, 2012 in the Institute for Nuclear Research, Kyiv, Ukraine (http://lpd.kinr.kiev.ua/kmf12). This Project was carried out during three years (2010-2012) by scientists from various universities and institutes of the National Academy of Sciences of Ukraine; it was a logical continuation of the previous scientific program of the NAS of Ukraine "Researches of structure and composition of the Universe, hidden mass and dark energy (Kosmomikrofizyka)" in 2007-2009. These programs were devoted to theoretical and experimental investigations in astronomy, astrophysics, cosmology, physics of atomic nuclei and particle physics, which are related with the problems of dark matter and dark energy in the Universe.
[16]  oai:arXiv.org:1302.7112  [pdf] - 633724
Muon-induced background in the EDELWEISS dark matter search
Comments: 21 pages, 16 figures, Accepted for publication in Astropart. Phys
Submitted: 2013-02-28
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the determination of the angular dependent muon flux in LSM. The results are in good agreement with both MC simulations and earlier measurements. Synchronization of the muon-veto system with the phonon and ionization signals of the Ge detector array allowed identification of muon-induced events. Rates for all muon-induced events $\Gamma^{\mu}=(0.172 \pm 0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $\Gamma^{\mu-n} = 0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After vetoing, the remaining rate of accepted muon-induced neutrons in the EDELWEISS-II dark matter search was determined to be $\Gamma^{\mu-n}_{\rm irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on these results, the muon-induced background expectation for an anticipated exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{\mu-n}_{3000 kg\cdot d} < 0.6$ events.
[17]  oai:arXiv.org:1207.1815  [pdf] - 568705
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
Comments: PRD rapid communication accepted
Submitted: 2012-07-07, last modified: 2012-09-05
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed to WIMP elastic scattering after an exposure of 113 kg.d. For WIMPs of mass 10 GeV, the observation of one event in the WIMP search region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent WIMP-nucleon scattering cross-section, which constrains the parameter space associated with the findings reported by the CoGeNT, DAMA and CRESST experiments.
[18]  oai:arXiv.org:1103.4070  [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
Comments: 23 pages, 5 figures; matches published version
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.
[19]  oai:arXiv.org:1105.3377  [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS; Collaborations, EDELWEISS; :; Ahmed, Z.; Akerib, D. S.; Armengaud, E.; Arrenberg, S.; Augier, C.; Bailey, C. N.; Balakishiyeva, D.; Baudis, L.; Bauer, D. A.; Benoît, A.; Bergé, L.; Blümer, J.; Brink, P. L.; Broniatowski, A.; Bruch, T.; Brudanin, V.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Censier, B.; Chapellier, M.; Chardin, G.; Charlieux, F.; Cooley, J.; Coulter, P.; Cox, G. A.; Cushman, P.; Daal, M.; Defay, X.; De Jesus, M.; DeJongh, F.; Di Stefano, P. C. F.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.; Dragowsky, M. R.; Eitel, K.; Fallows, S.; Figueroa-Feliciano, E.; Filippini, J.; Filosofov, D.; Fourches, N.; Fox, J.; Fritts, M.; Gascon, J.; Gerbier, G.; Gironnet, J.; Golwala, S. R.; Gros, M.; Hall, J.; Hennings-Yeomans, R.; Henry, S.; Hertel, S. A.; Hervé, S.; Holmgren, D.; Hsu, L.; Huber, M. E.; Juillard, A.; Kamaev, O.; Kiveni, M.; Kluck, H.; Kos, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Leman, S. W.; Liu, S.; Loaiza, P.; Mahapatra, R.; Mandic, V.; Marnieros, S.; Martinez, C.; McCarthy, K. A.; Mirabolfathi, N.; Moore, D.; Nadeau, P.; Navick, X-F.; Nelson, H.; Nones, C.; Ogburn, R. W.; Olivieri, E.; Pari, P.; Pattavina, L.; Paul, B.; Phipps, A.; Pyle, M.; Qiu, X.; Rau, W.; Reisetter, A.; Ricci, Y.; Robinson, M.; Rozov, S.; Saab, T.; Sadoulet, B.; Sander, J.; Sanglard, V.; Schmidt, B.; Schnee, R. W.; Scorza, S.; Seitz, D. N.; Semikh, S.; Serfass, B.; Sundqvist, K. M.; Tarka, M.; Torrento-Coello, A. S.; Vagneron, L.; Verdier, M. -A.; Walker, R. J.; Wikus, P.; Yakushev, E.; Yellin, S.; Yoo, J.; Young, B. A.; Zhang, J.
Comments: Events, efficiencies, and main limit are available in text format (see README.txt)
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
[20]  oai:arXiv.org:1006.3098  [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark Matter searches
Comments: Accepted for publication in Astroparticle Physics; 14 pages, 10 figures
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.
[21]  oai:arXiv.org:1001.4383  [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Comments: submitted to Journal of Physics G: Nuclear and Particle Physics, 8 pages, 4 figures
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.
[22]  oai:arXiv.org:0912.0805  [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes
Comments: 14 pages, 3 figures. Submitted to Phys Lett. B
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.
[23]  oai:arXiv.org:0905.0753  [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Comments: submitted to Physical Review Letters
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.
[24]  oai:arXiv.org:astro-ph/0607502  [pdf] - 83705
Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils
Comments: 28 pages, 7 figures. Submitted to Phys. Rev. D
Submitted: 2006-07-21
The heat quenching factor Q' (the ratio of the heat signals produced by nuclear and electron recoils of equal energy) of the heat-and-ionization germanium bolometers used by the EDELWEISS collaboration has been measured. It is explained how this factor affects the energy scale and the effective quenching factor observed in calibrations with neutron sources. This effective quenching effect is found to be equal to Q/Q', where Q is the quenching factor of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q' is combined with values of Q obtained from a review of all available measurements of this quantity in tagged neutron beam experiments. The systematic uncertainties associated with this method to evaluate Q' are discussed in detail. For recoil energies between 20 and 100 keV, the resulting heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the contributions from the Q and Q/Q' measurements, respectively. The present compilation of Q values and evaluation of Q' represent one of the most precise determinations of the absolute energy scale for any detector used in direct searches for dark matter.